1
|
Khalefa BB, Yassin MNA, Gonnah AR, Elkasaby MH, Hasan MT, Altobaishat O, Bani-Salame A, Rashed MA, Mansour MA, Al Hennawi H, Roberts DH. Self-Expandable Versus Balloon-Expandable Transcatheter Aortic Valve Replacement for Treatment of Patients With Small Aortic Annulus: An Updated Meta-Analysis of Reconstructed Individual Patient Data. Cardiol Rev 2024:00045415-990000000-00376. [PMID: 39629988 DOI: 10.1097/crd.0000000000000818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2024]
Abstract
Transcatheter aortic valve replacement has emerged as an effective alternative to surgery in selected patients with aortic stenosis. It needs to be made clear which type of valve has better results in patients with small aortic annulus. We searched PubMed, Scopus, Embase, Cochrane Library, and Web of Science, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. A total of 27 articles were included, including 10,378 patients [5989 in balloon-expanding valve (BEV) and 4389 in the self-expanding valve (SEV) groups] with small aortic annulus. Our meta-analysis demonstrated no significant difference between SEVs and BEVs for 1-year all-cause mortality. There was a statistically significant increased risk of permanent pacemaker implantation (PPI) within 30 days and ischemic stroke at 1 year with SEVs [risk ratio (RR) = 1.69, 95% confidence interval (CI) = 1.18-2.42, P < 0.01, and RR = 1.83, 95% CI = 1.03-3.26, P = 0.04, respectively]. Our meta-analysis showed that SEVs are favored over BEVs in terms of 1-year change from baseline in effective orifice area (mean difference = 0.45, 95% CI = 0.19-0.71, P < 0.01). Moreover, after 1-year follow-up, severe patient-prosthesis mismatch was significantly lower in the SEV group (RR = 0.24, 95% CI = 0.11-0.53, P < 0.01). In conclusion, SEVs were associated with better echocardiographic outcomes from baseline. Patients with SEVs were more likely to develop stroke and require PPI but were less likely to have patient-prosthesis mismatch. The benefit of a larger effective aortic valve area with SEVs has to be balanced against higher PPI and stroke rates.
Collapse
Affiliation(s)
| | | | - Ahmed R Gonnah
- Department of Medicine, Imperial College Healthcare NHS Trust, London, United Kingdom
| | | | | | - Obieda Altobaishat
- Department of Medicine, Jordan University of Science and Technology, Irbid, Jordan
| | - Abdallah Bani-Salame
- Department of Medicine, Jordan University of Science and Technology, Irbid, Jordan
| | | | | | | | - David Hesketh Roberts
- Department of Cardiology, Lancashire Cardiac Centre, Blackpool, United Kingdom
- School of Medicine, University of Liverpool, Liverpool, United Kingdom
| |
Collapse
|
2
|
Suleman M, Masoud M, Khan MI, Ullah I, Ullah A, Jan RU, Zeb S, Ashfaq U, Raza A, Waleed M. Aortic root parameter analysis for transcatheter aortic valve implantation in the Pakistani population: a retrospective study. Egypt Heart J 2024; 76:140. [PMID: 39425827 PMCID: PMC11490468 DOI: 10.1186/s43044-024-00569-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2024] [Accepted: 09/27/2024] [Indexed: 10/21/2024] Open
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) is a growing treatment for aortic stenosis, but anatomical variations exist across populations. Asians tend to have smaller aortic annuli and higher bicuspid valve morphology compared to Westerners, potentially impacting TAVI valve selection and outcomes. This study analyzes aortic root parameters in Pakistani patients undergoing TAVI. RESULTS We conducted a retrospective analysis of 78 patients who underwent TAVI at the Peshawar Institute of Cardiology from January 2021 to March 2024. Pre-procedural CT scans were analyzed for aortic annulus diameters, area, and other relevant parameters. The mean age was 72.41 years (SD ± 11.99), and 61.5% were male. Aortic annulus diameters (minimum, mean, maximum) were 21.18 mm (SD ± 3.99), 24.21 mm (SD ± 3.93), and 27.49 mm (SD ± 4.43), respectively. Bicuspid aortic valves were present in 34.61% of patients. CONCLUSIONS Our findings suggest that Pakistani patients undergoing TAVI may have aortic root dimensions comparable to Western populations, with a substantial prevalence of bicuspid valves. However, coronary heights were similar to those reported in Asian populations with smaller annuli. Further studies are needed to assess TAVI outcomes in Pakistani patients and determine if tailored valve sizing strategies are required.
Collapse
Affiliation(s)
| | - Maryam Masoud
- Peshawar Institute of Cardiology, Peshawar, Pakistan
| | | | - Ihsan Ullah
- Peshawar Institute of Cardiology, Peshawar, Pakistan
| | - Abid Ullah
- Peshawar Institute of Cardiology, Peshawar, Pakistan
| | | | - Shah Zeb
- Peshawar Institute of Cardiology, Peshawar, Pakistan
| | - Umar Ashfaq
- Peshawar Institute of Cardiology, Peshawar, Pakistan
| | - Ali Raza
- Peshawar Institute of Cardiology, Peshawar, Pakistan.
| | | |
Collapse
|
3
|
Di Pietro G, Improta R, Bruno F, De Filippo O, Leone PP, Nebiolo M, Giacobbe F, Caporusso D, Birtolo LI, Ielasi A, Mohamed AW, Ho KW, Meguro K, Ferrara J, Waksman R, Pilgrims T, McKay RG, Seiffert M, Massimo M, De Ferrari GM, D'Ascenzo F. Impact of Small Aortic Annuli on the Performance of Transcatheter Aortic Valve Replacement Bioprostheses: An Updated Meta-Analysis of Recent Studies. Am J Cardiol 2024; 229:1-12. [PMID: 39053723 DOI: 10.1016/j.amjcard.2024.07.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Revised: 07/15/2024] [Accepted: 07/19/2024] [Indexed: 07/27/2024]
Abstract
A metanalysis of available randomized controlled trials and observational studies comparing self-expanding (SE) and balloon-expandable (BE) bioprostheses in patients with small aortic annulus and aortic stenosis for short- and midterm hemodynamic and clinical outcomes was performed. A total of 21 studies with a total 8,647 patients (SE: n = 4,336 patients vs BE: n = 4,311 patients) were included. SE bioprostheses had a lower postoperative mean gradient at 30 days (Mean Difference [MD] -5.16, 95% confidence interval [CI] 4.7 to 5.5, p <0.001) and at 1 year (MD -6.6, 95%CI 6.1 to 7.03, p <0.001), with a larger indexed effective orifice area (0.17, 95% CI 0.13 to 0.22, p <0.001 and 0.17, 95% CI 0.08 to 0.27, p <0.001) at both time intervals. BE bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (risk ratio [RR] 1.07, 95% CI 1.04 to 1.09, p <0.001; RR 1.07, 95% CI 1.04 to 1.11, p <0.001). The 30-day and 1 year paravalvular leaks (RR 0.99, 95% CI 0.98 to 0.99, p <0.001; RR 0.89, 95% CI 0.82 to 0.95, p <0.001) and permanent pacemaker implantation (RR 0.97, 95% CI 0.94 to 0.99, p 0.01, I2 = 40%,) were lower in the BE group. BE bioprostheses were associated with a lower risk of in-hospital stroke (RR 0.99, 95% CI 0.98 to 1, p = 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior hemodynamic performance but higher rates of paravalvular leak, permanent pacemaker implantation, and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe prosthesis-patient mismatch.
Collapse
Affiliation(s)
- Gianluca Di Pietro
- Department of Clinical, Internal, Anesthesiology and Cardiovascular Sciences, Umberto I Hospital, Sapienza University of Rome, Italy; Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| | - Riccardo Improta
- Department of Clinical, Internal, Anesthesiology and Cardiovascular Sciences, Umberto I Hospital, Sapienza University of Rome, Italy; Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| | - Francesco Bruno
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| | - Ovidio De Filippo
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy.
| | - Pier Pasquale Leone
- Department of Biomedical Sciences, Humanitas University, Milan, Italy; Cardio Center, IRCCS Humanitas Research Hospital, Milan, Italy; The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, New York
| | - Marco Nebiolo
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| | - Federico Giacobbe
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| | - David Caporusso
- Gefäßchirurgie, Klinikum Munchen West, Lehrkrankenhaus LMU, Germany
| | - Lucia Ilaria Birtolo
- Department of Clinical, Internal, Anesthesiology and Cardiovascular Sciences, Umberto I Hospital, Sapienza University of Rome, Italy
| | - Alfonso Ielasi
- UO Cardiologia Ospedaliera IRCCS Ospedale Galeazzi Sant'Ambrogio, Milano, Italy
| | | | - Kay Woon Ho
- Department of Cardiology, National Heart Center, Singapore
| | - Kentaro Meguro
- Department of Cardiovascular Medicine, Kitasato University, Sagamihara Japan
| | - Jerome Ferrara
- Department de Cardiologie, CHU Timone, Marseille, France
| | - Ron Waksman
- Section of Interventional Cardiology, Medstar Washington Hospital Center, Washington, District of Columbia
| | - Thomas Pilgrims
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland
| | - Raymond G McKay
- Department of Cardiology, Hartford Healthcare Heart and Vascular Institute, Hartford Hospital, Hartford, Connecticut
| | - Moritz Seiffert
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Mancone Massimo
- Department of Clinical, Internal, Anesthesiology and Cardiovascular Sciences, Umberto I Hospital, Sapienza University of Rome, Italy
| | - Gaetano Maria De Ferrari
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| | - Fabrizio D'Ascenzo
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy
| |
Collapse
|
4
|
Bacco LD, D’Alonzo M, Eusanio MD, Rosati F, Solinas M, Baudo M, Folliguet T, Benussi S, Fischlein T, Muneretto C. Sutureless Aortic Valve Replacement vs. Transcatheter Aortic Valve Implantation in Patients with Small Aortic Annulus: Clinical and Hemodynamic Outcomes from a Multi-Institutional Study. Braz J Cardiovasc Surg 2024; 39:e20230155. [PMID: 39038084 PMCID: PMC11259373 DOI: 10.21470/1678-9741-2023-0155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 08/21/2023] [Indexed: 07/24/2024] Open
Abstract
OBJECTIVE This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.
Collapse
Affiliation(s)
- Lorenzo Di Bacco
- Department of Cardiac Surgery, ASST Spedali Civili di Brescia,
University of Brescia, Brescia, Italy
| | - Michele D’Alonzo
- Department of Cardiac Surgery, ASST Spedali Civili di Brescia,
University of Brescia, Brescia, Italy
| | - Marco Di Eusanio
- Cardiovascular Surgery Department, Ospedali Riuniti, Ancona, Italy
| | - Fabrizio Rosati
- Department of Cardiac Surgery, ASST Spedali Civili di Brescia,
University of Brescia, Brescia, Italy
| | - Marco Solinas
- Department of Adult Cardiac Surgery, G. Pasquinucci Heart Hospital,
Massa, Italy
| | - Massimo Baudo
- Department of Cardiac Surgery, ASST Spedali Civili di Brescia,
University of Brescia, Brescia, Italy
| | - Thierry Folliguet
- Cardiac surgery, Centre Hospitalier Universitaire Mondor,
Créteil, France
| | - Stefano Benussi
- Department of Cardiac Surgery, ASST Spedali Civili di Brescia,
University of Brescia, Brescia, Italy
| | - Theodor Fischlein
- Department of Cardiac Surgery, Klinikum Nürnberg, Nuremberg,
Germany
| | - Claudio Muneretto
- Department of Cardiac Surgery, ASST Spedali Civili di Brescia,
University of Brescia, Brescia, Italy
| |
Collapse
|
5
|
Möllmann H, Linke A, Nombela-Franco L, Sluka M, Francisco Oteo Dominguez J, Montorfano M, Kim WK, Arnold M, Vasa-Nicotera M, Fichtlscherer S, Conradi L, Camuglia A, Bedogni F, Kohli K, Manoharan G. Valve Hemodynamics by Valve Size and 1-Year Survival Following Implantation of the Portico Valve in the Multicenter CONFIDENCE Registry. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100226. [PMID: 38283573 PMCID: PMC10818152 DOI: 10.1016/j.shj.2023.100226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 08/09/2023] [Accepted: 08/31/2023] [Indexed: 01/30/2024]
Abstract
Background The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier NCT03752866.
Collapse
Affiliation(s)
- Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Axel Linke
- Department of Internal Medicine/Cardiology, University Hospital of the Technical University of Dresden, Heart Center Dresden, Dresden, Germany
| | - Luis Nombela-Franco
- Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain
| | - Martin Sluka
- Department of Medicine-Cardiology, University Hospital Olomouc, Olomouc, Czech Republic
| | | | - Matteo Montorfano
- Interventional Cardiology Unit IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Won-Keun Kim
- Kerckhoff Heart and Thorax Centre, Bad Nauheim, Germany
| | - Martin Arnold
- Department of Cardiology, Friedrich-Alexander-Universität Erlangen Nuremberg, Erlangen, Germany
| | - Mariuca Vasa-Nicotera
- Department of Cardiology, University Hospital of the Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Stephan Fichtlscherer
- Department of Cardiology, University Hospital of the Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Lenard Conradi
- Department of Cardiovascular Surgery, University Heart and Vascular Center, Hamburg, Germany
| | - Anthony Camuglia
- University of Queensland, Brisbane, Australia
- The Wesley Hospital, Brisbane, Australia
| | | | - Keshav Kohli
- Abbott Laboratories, Santa Clara, California, USA
| | | |
Collapse
|
6
|
Hosseinpour A, Gupta R, Kamalpour J, Hosseinpour H, Chaturvedi A, Agrawal A, Patel NC, Patel C. Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients With Small Aortic Annulus: A Meta-Analysis. Am J Cardiol 2023; 204:257-267. [PMID: 37562191 DOI: 10.1016/j.amjcard.2023.07.100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 08/12/2023]
Abstract
Although transcatheter aortic valve implantation (TAVI) is considered a superior option to surgery in patients with small aortic annulus (SAA), it is not clear which type of transcatheter heart valve (THV) has better results in terms of echocardiographic hemodynamics and clinical outcomes. A random-effects meta-analysis was performed comparing balloon-expandable valves (BEVs) and self-expanding valves (SEVs) in patients with SAA who underwent TAVI regarding their impact on hemodynamic and clinical outcomes at short- and midterm follow-up. Relative risk (RR) and mean difference (MD) with 95% confidence interval (95% CI) were measured for the outcomes, as appropriate. Subgroup analyses were performed based on the generation type of devices and study designs. A total of 16 articles comprising 1 randomized trial, 3 propensity-matched studies, and 12 observational studies including 4,341 patients (1,967 in BEV and 2,374 in the SEV group) with SAA were included. The implantation of BEVs correlated with a lower indexed effective orifice area (MD -0.19 [-0.25 to -0.13]) and higher transvalvular mean pressure gradient (MD 3.91, 95% CI 2.96 to 4.87). Compared with SEVs, BEVs had increased risk of prosthesis-patient mismatch (PPM; RR 2.09, 95% CI 1.79 to 2.45) and severe PPM (RR 2.16, 95% CI 1.48 to 3.15). However, BEV had lower moderate and severe paravalvular leak (RR 0.45, 95% CI 0.29 to 0.69), risk of stroke (RR 0.57, 95% CI 0.42 to 0.76), and permanent pacemaker implantation (RR 0.63, 95% CI 0.44 to 0.91). The 1-year all-cause mortality (RR 1.13, 95% CI 0.86 to 1.49) and cardiac-related mortality (RR 1.53, 95% CI 0.24 to 9.81) were not different between the 2 groups. In conclusion, SEVs were associated with larger indexed effective orifice area and lower PPM but higher paravalvular leak. In contrast, patients with SEVs were more likely to develop stroke and required permanent pacemaker implantation. Both THVs did not show difference in terms of early and midterm all-cause and cardiac mortality. Because both types of THVs show similar results regarding mortality data, hemodynamics should be among the factors considered in decision making for patients with SAA who underwent TAVI.
Collapse
Affiliation(s)
| | - Rahul Gupta
- Lehigh Valley Heart and Vascular Institute, Lehigh Valley Health Network, Allentown, Pennsylvania.
| | | | | | - Abhishek Chaturvedi
- Pauley Heart Center, Virginia Commonwealth University School of Medicine, Richmond, Virginia
| | - Ankit Agrawal
- Department of Hospital Medicine, Cleveland Clinic, Cleveland, Ohio
| | - Nainesh C Patel
- Lehigh Valley Heart and Vascular Institute, Lehigh Valley Health Network, Allentown, Pennsylvania
| | - Chirdeep Patel
- Lehigh Valley Heart and Vascular Institute, Lehigh Valley Health Network, Allentown, Pennsylvania
| |
Collapse
|
7
|
Abushouk AI, Spilias N, Isogai T, Kansara T, Agrawal A, Hariri E, Abdelfattah O, Krishnaswamy A, Reed GW, Puri R, Yun J, Kapadia S. Three-Year Outcomes of Balloon-Expandable Transcatheter Aortic Valve Implantation According to Annular Size. Am J Cardiol 2023; 194:9-16. [PMID: 36921423 DOI: 10.1016/j.amjcard.2023.01.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/23/2023] [Accepted: 01/31/2023] [Indexed: 03/18/2023]
Abstract
Data on the association between annular size and transcatheter aortic valve implantation (TAVI) outcomes beyond 1 year are limited. The present study assessed the association between the aortic annulus size and TAVI clinical and hemodynamic outcomes at 3 years of follow-up. Patients were classified according to the aortic annulus size as having small, intermediate, and large annuli (size <400, 400 to 574, and ≥575 mm2, respectively). The co-primary endpoints were all-cause mortality and heart failure hospitalization. Further, the changes in hemodynamic outcomes over the follow-up period (median 37, interquartile range: 26 to 45 months) were assessed. The present analysis included 850 patients, with 182 patients (21.4%), 538 patients (63.3%), and 130 patients (15.3%) in the small, intermediate, and large-sized aortic annulus groups, respectively. The groups had comparable age and pre-TAVI pressure gradients; however, patients with small annuli had higher Society of Thoracic Surgeons risk scores. Adjusted Cox regression analysis showed that compared to patients with intermediate-sized annuli, patients with small and large annuli had similar all-cause mortality (hazard ratio [HR] = 1.11, 95% confidence interval [CI] 0.72 to 1.69 and HR = 0.74, 95% CI 0.48 to 1.16, respectively) and heart failure hospitalization rates (HR = 0.96, 95% CI 0.55 to 1.69 and HR = 1.26, 95% CI 0.73 to 2.17, respectively). However, patients with small annuli had consistently higher mean and peak pressure gradients and a higher risk of patient-prosthesis mismatch. The risks of moderate-to-severe regurgitation and structural valve deterioration were similar between the three groups. In conclusion, although patients with small annuli had higher transvalvular gradients, there was no significant association between the aortic annulus size and TAVI clinical outcomes at 3 years of follow-up. Future studies should compare the performance of transcatheter valve types in patients with different aortic annulus sizes.
Collapse
Affiliation(s)
- Abdelrahman I Abushouk
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Nikolaos Spilias
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Toshiaki Isogai
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Tikal Kansara
- Department of Internal Medicine, Cleveland Clinic Union Hospital, Dover, Ohio
| | - Ankit Agrawal
- Department of Internal Medicine, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Essa Hariri
- Department of Internal Medicine, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Omar Abdelfattah
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Amar Krishnaswamy
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Grant W Reed
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Rishi Puri
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - James Yun
- Department of Thoracic and Cardiovascular Surgery, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Samir Kapadia
- Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic Foundation, Cleveland, Ohio.
| |
Collapse
|
8
|
Eaves S, Lees C, Jin D, Rayner C, Paleri S, Rowe S, Lee J, Hayat U, Adams H. Dedicated Next Day Discharge Post Minimalist TAVI: The Tasmanian Experience. Heart Lung Circ 2023; 32:232-239. [PMID: 36272953 DOI: 10.1016/j.hlc.2022.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 08/22/2022] [Accepted: 09/14/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVES To assess the safety, feasibility and independent predictors of next day discharge (NDD) in patients undergoing minimalist transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) in a real-world Australian population. METHODS This single centre study reviewed 135 consecutive patients who underwent minimalist transfemoral TAVI from June 2020 to February 2022. Baseline demographics, procedural characteristic and outcomes were obtained. All patients were assessed by the local protocol for NDD. Patients were then divided into two groups: those who achieved next day discharge (NDD) and those requiring >1 overnight hospital stay. Univariate, bivariate and stepwise multivariate logistic regression modelling was used to identify the predictors of successful next day discharge. RESULTS The mean age of the cohort was 82.9±5.7 years with 62.3% patients male, the average STS score was 4.1±2.4. All 135 patients underwent a successful transfemoral TAVI procedure, with 131 (97%) receiving a balloon-expandable valve. Ninety-seven (97) (71.9%) patients achieved NDD. Thirty (30)-day outcomes were excellent with a 30-day mortality of 0.7%, transient ischaemic attack/cardiovascular accident (TIA/CVA) 1.5%, major vascular complication 1.5% and 11.4% need for permanent pacemaker (PPM). In patients not achieving NDD, the average length of stay (LOS) was 3.0 days. Baseline characteristics demonstrated pre-existing first degree atrioventricular (AV) block and right bundle branch block (RBBB) as statistically significant negative predictors of NDD on univariate analysis. Next day discharge was achievable in only 50% of patients who suffered any minor or major procedural complication (15/30). Stepwise multivariate logistic regression modelling demonstrated female gender (OR 3.094, 95% CI 1.141-8.391, p=0.026), smaller aortic valve area (AVA) (OR 48.265, 95% CI 2.269-102.6, p=0.013), the presence of diabetes mellitus (OR 0.594, 95% CI 0.356-0.991, p=0.046) and a longer procedure time (OR 0.960, 95% CI 0.935-0.986, p=0.002) as statistically significant negative predictors of NDD. In addition, there was no difference in 30-day readmission rates between the NDD and non-NDD cohort (7.2% vs 10.5%, p=0.386). CONCLUSION Next day discharge is safe and feasible in almost three quarters of patients undergoing minimalist TAVI for severe AS in a predominantly balloon expandable valve cohort, with a very low rate of 30-day readmission. NDD provides advantages for hospital efficiency and improved cost-effectiveness. Female gender, smaller AVA, the presence of diabetes mellitus and a longer procedure time were independent negative predictors of successful NDD.
Collapse
Affiliation(s)
- Scott Eaves
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia.
| | - Conor Lees
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - David Jin
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - Clare Rayner
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - Sarang Paleri
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - Stephanie Rowe
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - John Lee
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - Umair Hayat
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia
| | - Heath Adams
- Department of Cardiology, Royal Hobart Hospital, Hobart, Tas, Australia; Menzies Research Institute, University of Tasmania, Hobart, Tas, Australia
| |
Collapse
|
9
|
Hofferberth SC, Saeed MY, Tomholt L, Fernandes MC, Payne CJ, Price K, Marx GR, Esch JJ, Brown DW, Brown J, Hammer PE, Bianco RW, Weaver JC, Edelman ER, Del Nido PJ. A geometrically adaptable heart valve replacement. Sci Transl Med 2021; 12:12/531/eaay4006. [PMID: 32075944 DOI: 10.1126/scitranslmed.aay4006] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Accepted: 01/23/2020] [Indexed: 12/12/2022]
Abstract
Congenital heart valve disease has life-threatening consequences that warrant early valve replacement; however, the development of a growth-accommodating prosthetic valve has remained elusive. Thousands of children continue to face multiple high-risk open-heart operations to replace valves that they have outgrown. Here, we demonstrate a biomimetic prosthetic valve that is geometrically adaptable to accommodate somatic growth and structural asymmetries within the heart. Inspired by the human venous valve, whose geometry is optimized to preserve functionality across a wide range of constantly varying volume loads and diameters, our balloon-expandable synthetic bileaflet valve analog exhibits similar adaptability to dimensional and shape changes. Benchtop and acute in vivo experiments validated design functionality, and in vivo survival studies in growing sheep demonstrated that mechanical valve expansion accommodated growth. As illustrated in this work, dynamic size adaptability with preservation of unidirectional flow in prosthetic valves thus offers a paradigm shift in the treatment of heart valve disease.
Collapse
Affiliation(s)
- Sophie C Hofferberth
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Mossab Y Saeed
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Lara Tomholt
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138, USA.,Harvard Graduate School of Design, Harvard University, Cambridge, MA 02138, USA
| | - Matheus C Fernandes
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138, USA.,John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Christopher J Payne
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Karl Price
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Gerald R Marx
- Department of Cardiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Jesse J Esch
- Department of Cardiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - David W Brown
- Department of Cardiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Jonathan Brown
- Biomedical Engineering Center, Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Peter E Hammer
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Richard W Bianco
- Department of Surgery, University of Minnesota, Minneapolis, MN 55455, USA
| | - James C Weaver
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138, USA
| | - Elazer R Edelman
- Biomedical Engineering Center, Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Pedro J Del Nido
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| |
Collapse
|
10
|
Greco A, Capranzano P, Barbanti M, Tamburino C, Capodanno D. Antithrombotic pharmacotherapy after transcatheter aortic valve implantation: an update. Expert Rev Cardiovasc Ther 2019; 17:479-496. [PMID: 31198065 DOI: 10.1080/14779072.2019.1632189] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Introduction: Transcatheter aortic valve implantation (TAVI) is the treatment of choice for a large proportion of patients with severe aortic stenosis. Despite numerous technological and clinical advances, TAVI remains associated with thrombotic complications requiring antithrombotic pharmacotherapy, which exposes to the risk of bleeding, especially in elderly individuals. The optimal antithrombotic regimen following TAVI is uncertain and several investigations are ongoing. Areas covered: Clinical guidelines are mostly driven by observational trials and experts' opinions, thus resulting into low-grade level of evidence. The aim of the current review is to critically explore the epidemiology, pathophysiology and prognostic value of thrombotic and bleeding events after TAVI, and to review the current literature on antithrombotic strategies following the procedure. Expert opinion: Thrombotic and bleeding events remain major complications occurring in the frail population that is currently offered TAVI. Waiting for upcoming evidence from ongoing randomized clinical trials, tailoring antithrombotic therapies based on patients' characteristics, values and circumstances is a preferable approach.
Collapse
Affiliation(s)
- Antonio Greco
- a Division of Cardiology , A.O.U. "Policlinico-Vittorio Emanuele", University of Catania , Catania , Italy
| | - Piera Capranzano
- a Division of Cardiology , A.O.U. "Policlinico-Vittorio Emanuele", University of Catania , Catania , Italy
| | - Marco Barbanti
- a Division of Cardiology , A.O.U. "Policlinico-Vittorio Emanuele", University of Catania , Catania , Italy
| | - Corrado Tamburino
- a Division of Cardiology , A.O.U. "Policlinico-Vittorio Emanuele", University of Catania , Catania , Italy
| | - Davide Capodanno
- a Division of Cardiology , A.O.U. "Policlinico-Vittorio Emanuele", University of Catania , Catania , Italy
| |
Collapse
|