1
|
Pinelli F, Pittiruti M, Annetta MG, Barbani F, Bertoglio S, Biasucci DG, Bolis D, Brescia F, Capozzoli G, D'Arrigo S, Deganello E, Elli S, Fabiani A, Fabiani F, Gidaro A, Giustivi D, Iacobone E, La Greca A, Longo F, Lucchini A, Marche B, Romagnoli S, Scoppettuolo G, Selmi V, Vailati D, Villa G, Pepe G. A GAVeCeLT consensus on the indication, insertion, and management of central venous access devices in the critically ill. J Vasc Access 2024:11297298241262932. [PMID: 39097780 DOI: 10.1177/11297298241262932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/05/2024] Open
Abstract
Central venous access devices are essential for the management of critically ill patients, but they are potentially associated with many complications, which may occur during or after insertion. Many evidence-based documents-consensus and guidelines-suggest practical recommendations for reducing catheter-related complications, but they have some limitations. Some documents are not focused on critically ill patients; other documents address only some special strategies, such as the use of ultrasound; other documents are biased by obsolete concepts, inappropriate terminology, and lack of considerations for new technologies and new methods. Thus, the Italian Group of Venous Access Devices (GAVeCeLT) has decided to offer an updated compendium of the main strategies-old and new-that should be adopted for minimizing catheter-related complications in the adult critically ill patient. The project has been planned as a consensus, rather than a guideline, since many issues in this field are relatively recent, and few high-quality randomized clinical studies are currently available, particularly in the area of indications and choice of the device. Panelists were chosen between the Italian vascular access experts who had published papers on peer-reviewed journals about this topic in the last few years. The consensus process was carried out according to the RAND/University of California at Los Angeles (UCLA) Appropriateness Methodology, a modification of the Delphi method, that is, a structured process for collecting knowledge from groups of experts through a series of questionnaires. The final document has been structured as statements which answer to four major sets of questions regarding central venous access in the critically ill: (1) before insertion (seven questions), (2) during insertion (eight questions), (3) after insertion (three questions), and (4) at removal (three questions).
Collapse
Affiliation(s)
- Fulvio Pinelli
- Department of Anesthesia and Critical Care, University of Florence, "Careggi" Hospital, Florence, Italy
| | - Mauro Pittiruti
- Department of Surgery, Policlinico Universitario "A.Gemelli," Rome, Italy
| | | | - Francesco Barbani
- Department of Anesthesia and Critical Care, University of Florence, "Careggi" Hospital, Florence, Italy
| | | | - Daniele G Biasucci
- Department of Clinical Science and Translational Medicine, "Tor Vergata" University, Rome, Italy
| | - Denise Bolis
- Intensive Care Unit, Hospital "A.Manzoni," Lecco, Italy
| | - Fabrizio Brescia
- Unit of Anesthesia and Intensive Care Medicine, Vascular Access Team, Centro di Riferimento Oncologico di Aviano, IRCCS, Aviano, Italy
| | - Giuseppe Capozzoli
- Department of Anesthesiology, Hospital of Bolzano, Lehr-Krankenhaus der Paracelsus Medizinischen Privatuniversität, Bolzano, Italy
| | - Sonia D'Arrigo
- Department of Anesthesia and Intensive Care, Policlinico Universitario "A.Gemelli," Rome, Italy
| | - Elisa Deganello
- Anaesthesia and Intensive Care, Ospedali Riuniti Padova Sud, Monselice, Italy
| | - Stefano Elli
- Vascular Access Team, Fondazione "San Gerardo dei Tintori," Monza, Italy
| | - Adam Fabiani
- Cardiac Surgery Intensive Care Unit, Vascular Access Team, Azienda Sanitaria Universitaria Giuliano-Isontina, Trieste, Italy
| | - Fabio Fabiani
- Unit of Anesthesia and Intensive Care Medicine, Vascular Access Team, Centro di Riferimento Oncologico di Aviano, IRCCS, Aviano, Italy
| | - Antonio Gidaro
- Department of Biomedical and Clinical Sciences, University of Milan, "Luigi Sacco" Hospital, Milan, Italy
| | - Davide Giustivi
- Post-Anesthesia Care Unit and Vascular Access Team, Lodi, Italy
| | - Emanuele Iacobone
- Anesthesia and Intensive Care, Hospital of Macerata, Macerata, Italy
| | - Antonio La Greca
- Department of Surgery, Policlinico Universitario "A.Gemelli," Rome, Italy
| | | | - Alberto Lucchini
- Adult and Pediatric Intensive Care Unit, Fondazione "San Gerardo dei Tintori," Monza, Italy
| | - Bruno Marche
- Department of Hematology, Policlinico Universitario "A.Gemelli," Rome, Italy
| | - Stefano Romagnoli
- Department of Anesthesia and Critical Care, University of Florence, "Careggi" Hospital, Florence, Italy
| | | | - Valentina Selmi
- Vascular Access Team, Department of Anesthesia and Critical Care, University of Florence, "Careggi" Hospital, Florence, Italy
| | - Davide Vailati
- Department of Anesthesia and Intensive Care, Melegnano Hospital, Milano, Italy
| | - Gianluca Villa
- Department of Anesthesia and Critical Care, University of Florence, "Careggi" Hospital, Florence, Italy
| | - Gilda Pepe
- Department of Surgery, Policlinico Universitario "A.Gemelli," Rome, Italy
| |
Collapse
|
2
|
Preventive strategies for the reduction of central line-associated bloodstream infections in adult intensive care units: A systematic review. Collegian 2021. [DOI: 10.1016/j.colegn.2020.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
3
|
Analysis of Factors Causing Skin Damage in the Application of Peripherally Inserted Central Catheter in Cancer Patients. JOURNAL OF ONCOLOGY 2021; 2021:6628473. [PMID: 33815501 PMCID: PMC7990541 DOI: 10.1155/2021/6628473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 02/08/2021] [Accepted: 03/02/2021] [Indexed: 11/17/2022]
Abstract
Objective To investigate the related factors of skin damage caused by peripherally inserted central catheter (PICC) in cancer patients. Methods It was a retrospective analysis of 202 cancer patients admitted to our hospital from February 2014 to July 2019. 50 cases of PICC-related skin damage and 152 cases of non-skin damage were studied. In addition, multivariate logistic regression analysis was used to determine independent risk factors for PICC-related skin damage, including cancer patients with catheter-related skin damage and patients without skin damage. Results 50 patients with PICC skin damage (19 males and 31 females) and 152 patients without skin damage (62 males and 90 females) were retrospectively analyzed. The skin damage rate was 24.8%. The analysis of variance results showed that many factors are related to PICC catheter-related skin damage, including hormones (χ2/Z = 4.468, P < 0.05), body mass index (BMI) (χ2/Z = −2.443, P < 0.05), days with tube (χ2 = 26.230, P < 0.05), chemotherapy cycle (χ2/Z = 25.638, P < 0.05), and self-care ability (χ2/Z = −1.968, P < 0.05). Logistic regression analysis showed that hormones (odds ratio (OR) = 3.896, P=0.045), BMI (OR = 1.129, P=0.017), days with tube (OR = 0.419, P=0.013), and chemotherapy cycle (OR = 3.302, P=0.028) are independent factors affecting PICC-related skin damage. Conclusion The independent influencing factors of skin damage during PICC catheterization are hormones, BMI, number of days with tube, and chemotherapy cycle.
Collapse
|
4
|
Effectiveness of chlorhexidine dressings to prevent catheter-related bloodstream infections. Does one size fit all? A systematic literature review and meta-analysis. Infect Control Hosp Epidemiol 2020; 41:1388-1395. [DOI: 10.1017/ice.2020.356] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
AbstractObjective:To evaluate the effectiveness of chlorhexidine (CHG) dressings to prevent catheter-related bloodstream infections (CRBSIs).Design:Systematic review and meta-analysis.Methods:We searched PubMed, CINAHL, EMBASE, and ClinicalTrials.gov for studies (randomized controlled and quasi-experimental trials) with the following criteria: patients with short- or long-term catheters; CHG dressings were used in the intervention group and nonantimicrobial dressings in the control group; CRBSI was an outcome. Random-effects models were used to obtain pooled risk ratios (pRRs). Heterogeneity was evaluated using the I2 test and the Cochran Q statistic.Results:In total, 20 studies (18 randomized controlled trials; 15,590 catheters) without evidence of publication bias and mainly performed in intensive care units (ICUs) were included. CHG dressings significantly reduced CRBSIs (pRR, 0.71; 95% CI, 0.58–0.87), independent of the CHG dressing type used. Benefits were limited to adults with short-term central venous catheters (CVCs), including onco-hematological patients. For long-term CVCs, CHG dressings decreased exit-site/tunnel infections (pRR, 0.37; 95% CI, 0.22–0.64). Contact dermatitis was associated with CHG dressing use (pRR, 5.16; 95% CI, 2.09–12.70); especially in neonates and pediatric populations in whom severe reactions occurred. Also, 2 studies evaluated and did not find CHG-acquired resistance.Conclusions:CHG dressings prevent CRBSIs in adults with short-term CVCs, including patients with an onco-hematological disease. CHG dressings might reduce exit-site and tunnel infections in long-term CVCs. In neonates and pediatric populations, proof of CHG dressing effectiveness is lacking and there is an increased risk of serious adverse events. Future studies should investigate CHG effectiveness in non-ICU settings and monitor for CHG resistance.
Collapse
|
5
|
Abstract
These practice guidelines update the Practice Guidelines for Central Venous Access: A Report by the American Society of Anesthesiologists Task Force on Central Venous Access, adopted by the American Society of Anesthesiologists in 2011 and published in 2012. These updated guidelines are intended for use by anesthesiologists and individuals under the supervision of an anesthesiologist and may also serve as a resource for other physicians, nurses, or healthcare providers who manage patients with central venous catheters.
Supplemental Digital Content is available in the text.
Collapse
|
6
|
Complication and Failures of Central Vascular Access Device in Adult Critical Care Settings. Crit Care Med 2019; 46:1998-2009. [PMID: 30095499 DOI: 10.1097/ccm.0000000000003370] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
OBJECTIVES To examine the proportion and rate of central venous access device failure and complications across central venous access device types in adult intensive care. DATA SOURCES A systematic search was undertaken in the electronic databases Cochrane Central Register of Controlled Trials, Embase, U.S. National Library of Medicine National Institutes of Health, and Cumulative Index to Nursing and Allied Health in September 2017. STUDY SELECTION Included studies were of observational (prospective and retrospective) or interventional design and reported central venous access device failure and complications in adult ICU settings. Studies were excluded if they were published prior to November 2006 or not reported in English. Two reviewers independently screened articles, assessed eligibility, extracted data, and assessed risk of bias. DATA EXTRACTION Data were extracted on the primary outcome, central venous access device failure, and secondary outcomes: central venous access device complications (central line-associated bloodstream infection, catheter-related bloodstream infection, catheter-related thrombosis, occlusion, catheter removal due to suspected infection, dislodgement, breakage, and local infection). Patient and device data and study details to assess the study quality were also extracted. DATA SYNTHESIS A total of 63 studies involving 50,000 central venous access devices (396,951 catheter days) were included. Central venous access device failure was 5% (95% CI, 3-6%), with the highest rates and proportion of failure in hemodialysis catheters. Overall central line-associated bloodstream infection rate was 4.59 per 1,000 catheter days (95% CI, 2.31-6.86), with the highest rate in nontunneled central venous access devices. Removal of central venous access device due to suspected infection was high (17%; 20.4 per 1,000 catheter days; 95% CI, 15.7-25.2). CONCLUSIONS Central venous access device complications and device failure is a prevalent and significant problem in the adult ICU, leading to substantial patient harm and increased healthcare costs. The high proportion of central venous access devices removed due to suspicion of infection, despite low overall central line-associated bloodstream infection and catheter-related bloodstream infection rates, indicates a need for robust practice guidelines to inform decision-making surrounding removal of central venous access devices suspected of infection.
Collapse
|
7
|
Chlorhexidine-impregnated dressing for the prophylaxis of central venous catheter-related complications: a systematic review and meta-analysis. BMC Infect Dis 2019; 19:429. [PMID: 31096918 PMCID: PMC6524337 DOI: 10.1186/s12879-019-4029-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Accepted: 04/26/2019] [Indexed: 02/06/2023] Open
Abstract
Background Several randomized controlled trials (RCTs) evaluated the role of Chlorhexidine-impregnated dressing for prophylaxis of central venous catheter (CVC) related complications, but the results remained inconsistent, updated meta-analyses on this issue are warranted. Methods A meta-analysis on the RCTs comparing Chlorhexidine-impregnated dressing versus other dressing or no dressing for prophylaxis of central venous catheter-related complications was performed. A comprehensive search of major databases was undertaken up to 30 Dec 2018 to identify related studies. Pooled odd ratio (OR) and mean differences (MDs) with 95% confidence intervals (CI) were calculated using either a fixed-effects or random-effects model. Subgroup analysis was performed to identify the source of heterogeneity, and funnel plot and Egger test was used to identify the publication bias. Results A total of 12 RCTs with 6028 patients were included. The Chlorhexidine-impregnated dressings provided significant benefits in reducing the risk of catheter colonization (OR = 0.46, 95% CI: 0.36 to 0.58), decreasing the incidence of catheter-related bloodstream infection (CRBSI) (OR = 0.60, 95% CI: 0.42 to 0.85). Subgroup analysis indicated that the Chlorhexidine-impregnated dressings were conducive to reduce the risk of catheter colonization and CRBSI within the included RCTs with sample size more than 200, but the differences weren’t observed for those with sample less than 200. No publication bias was observed in the Egger test for the risk of CRBSI. Conclusions Chlorhexidine-impregnated dressing is beneficial to prevent CVC-related complications. Future studies are warranted to assess the role and cost-effectiveness of Chlorhexidine-impregnated dressings.
Collapse
|
8
|
Dang FP, Li HJ, Tian JH. Comparative efficacy of 13 antimicrobial dressings and different securement devices in reducing catheter-related bloodstream infections: A Bayesian network meta-analysis. Medicine (Baltimore) 2019; 98:e14940. [PMID: 30946317 PMCID: PMC6455863 DOI: 10.1097/md.0000000000014940] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 02/26/2019] [Accepted: 02/28/2019] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The purpose of our study is to carry out a Bayesian network meta-analysis comparing the efficacy of different antimicrobial dressings for prevention of catheter-related blood infections (CRBSI) and rank these antimicrobial dressings for practical consideration. METHODS We searched the PubMed, Cochrane library, Embase, earlier relevant meta-analysis and reference lists of included studies for randomized controlled trials (RCTs) that compared dressings for prevention of CRBSI. Two authors independently extracted data from each included RCT according to a predesigned Excel spreadsheet and assessed the methodological quality of included RCTs using the Cochrane risk of bias tool. Data was analyzed using the WinBUGS (V.1.4.3) and the Stata (V.15.0). RESULTS Finally, 35 RCTs involving 8494 patients and evaluating 13 dressings were included. Network meta-analysis showed that transparent dressing may be the best way to prevent CRBSI. Suture and bordered polyurethane dressing might have the lowest risk of CRBSI rate per 1000 catheter-days, and sutureless securement device might lead to the lowest incidence of catheter failure. CONCLUSIONS This network meta-analysis indicated that transparent dressings may be selected for the prevention of CRBSI in patients with central venous catheters, which is of importance in future research. Although evidence is scant, more attention should be paid to head-to-head comparisons of the most commonly used dressings in this field.
Collapse
Affiliation(s)
| | - Hui-Ju Li
- School of Nursing of Lanzhou University
| | - Jin-Hui Tian
- School of Nursing of Lanzhou University
- Key Laboratory of Clinical Translational Research and Evidence-based Medicine of Gansu Province, Lanzhou, Gansu, China
| |
Collapse
|
9
|
Margatho AS, Ciol MA, Hoffman JM, Dos Reis PED, Furuya RK, Lima DAFS, Basile-Filho A, Silveira RCCP. Chlorhexidine-impregnated gel dressing compared with transparent polyurethane dressing in the prevention of catheter-related infections in critically ill adult patients: A pilot randomised controlled trial. Aust Crit Care 2018; 32:471-478. [PMID: 30558968 DOI: 10.1016/j.aucc.2018.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 10/24/2018] [Accepted: 11/01/2018] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND In patients with short-term percutaneous central venous catheter (CVC), it is recommended that a dressing be applied to the catheter insertion site to prevent catheter-related infections. OBJECTIVES The objective of this study was to assess the feasibility of a randomised controlled trial to compare the efficacy of chlorhexidine-impregnated dressing with that of polyurethane dressing in the prevention of catheter-related infections in critically ill adult patients with short-term percutaneous CVC. METHODS One hundred fifteen patients with a CVC were randomised to chlorhexidine-impregnated gel dressing (chlorhexidine gel group) or transparent polyurethane dressing (polyurethane group) between April and December 2014. Feasibility outcomes included data on eligibility, recruitment, missing data, and protocol violation. The primary outcome measure of efficacy was the presence of colonisation with the same microorganism in both the skin swab around catheter insertion site and the catheter tip. RESULTS Of 526 patients assessed for eligibility, 411 (78%) did not meet inclusion criteria, and 115 (22%) were randomised. Among participants of both groups, there were 14 missing primary outcomes of which 10 were due to failure to collect the catheter tip (a protocol violation). The final sample had 47 and 54 individuals in the chlorhexidine and polyurethane groups, respectively. Skin and catheter tip were colonised by the same microorganism for 13% of the participants in the chlorhexidine group and 8% in the polyurethane group, although the difference was not statistically significant (p = 0.51). There were no differences between the two groups for catheter tip colonisation, skin site colonisation, catheter insertion site infection, catheter-related bloodstream infection, skin irritation, and the number of unplanned dressing changes. CONCLUSIONS Our preliminary results found that a large randomised controlled trial would be feasible. This study provides valuable information that can be used to design more robust studies to prevent infection among patients with short-term percutaneous CVC when using either chlorhexidine or polyurethane dressing.
Collapse
Affiliation(s)
- Amanda S Margatho
- General and Specialized Nursing Department, Ribeirão Preto College of Nursing, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
| | - Marcia A Ciol
- Department of Rehabilitation Medicine, School of Medicine, University of Washington, Seattle, WA, USA.
| | - Jeanne M Hoffman
- Department of Rehabilitation Medicine, School of Medicine, University of Washington, Seattle, WA, USA.
| | - Paula E D Dos Reis
- Nursing Department, School of Health Sciences, University of Brasília, Brasília, DF, Brazil.
| | - Rejane K Furuya
- Federal Institute of Paraná, Campus Londrina, Londrina, PR, Brazil.
| | - Dennisani A F S Lima
- Department of Internal Medicine, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, SP, Brazil.
| | - Anibal Basile-Filho
- Division of Intensive Care, Department of Surgery and Anatomy, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, SP, Brazil.
| | - Renata C C P Silveira
- General and Specialized Nursing Department, Ribeirão Preto College of Nursing, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
| |
Collapse
|
10
|
Oliveira JKAD, Llapa-Rodriguez EO, Lobo IMF, Silva LDSL, Godoy SD, Silva GGD. Patient safety in nursing care during medication administration. Rev Lat Am Enfermagem 2018; 26:e3017. [PMID: 30110095 PMCID: PMC6091376 DOI: 10.1590/1518-8345.2350.3017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Accepted: 04/13/2018] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE to evaluate the conformity of care practices of the nursing team during the administration of drugs through central vascular catheter. METHOD a descriptive, prospective, observational study conducted in an Intensive Care Unit. The non-probabilistic intentional sample consisted of 3402 observations of drug administrations in patients with central vascular catheters. The previously validated collection instrument was constructed based on the Guideline for Prevention of Intravascular catheter-related infections. Data was collected through direct observations of nursing practices performed by the nursing team. The analysis used analytical, descriptive and inferential statistics (Chi-square test and Fisher's exact test). RESULTS a total of 3402 procedures of drug administrations were observed. Female nursing technicians performed the highest number of actions. In none of the procedures did the professional perform all necessary actions. 0.2% of drug administrations were preceded by hand hygiene and 1.3% by disinfection of the multidose vial, ampoule or injectors. CONCLUSION the practice evaluated was classified as undesirable. Failure to achieve the desired conformity was probably due to the low adherence of professionals to the practice of hand hygiene and disinfection of materials, injectors and connectors.
Collapse
Affiliation(s)
| | - Eliana Ofélia Llapa-Rodriguez
- Post-doctoral fellow, University of British Columbia, Columbia, Vancouver, Canada. Adjunct Professor, Departamento de Enfermagem, Universidade Federal de Sergipe, São Cristóvão, SE, Brazil
| | - Iza Maria Fraga Lobo
- PhD, Physician, Núcleo de Epidemiologia, Segurança do Paciente e Infecção Hospitalar, Hospital de Urgência de Sergipe, Aracaju, SE, Brazil
| | - Luciana de Santana Lôbo Silva
- Master's student, Universidade Federal de Sergipe, São Cristóvão, SE, Brazil. Assistant Professor, Estácio, Aracaju, SE, Brazil
| | - Simone de Godoy
- PhD, Professor, Escola de Enfermagem de Ribeirão Preto, Universidade de São Paulo, PAHO/WHO Collaborating Centre for Nursing Research Development, Ribeirão Preto, SP, Brazil
| | - Gilvan Gomes da Silva
- Undergraduate student in Nursing, Universidade Federal de Sergipe, São Cristóvão, SE, Brazil. Scholarship holder at Programa Institucional de Bolsas de Iniciação Científica, Coordenação de Pesquisa, Universidade Federal de Sergipe (PIBIC-COPES), Brazil
| |
Collapse
|
11
|
Prevalence of medical adhesive-related skin injury at peripherally inserted central catheter insertion site in oncology patients. J Vasc Access 2018; 19:23-27. [PMID: 29148003 DOI: 10.5301/jva.5000805] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Introduction: The aim of our study was to identify the prevalence and risk factors of medical adhesive-related skin injuries (MARSI) at peripherally inserted central catheters (PICC) insertion site in oncology patients. Methods: A cross-sectional observational study lasting two weeks was carried out in four inpatient departments. Skin assessment data and photographs of skin were collected during PICC maintenance. Other related information came from medical records. The skin injuries were classified by dermatologists and PICC specialized nurses. MARSI prevalence was calculated and the associated factors were analyzed statistically. Results: All 419 patients were included. The prevalence of total MARSI at PICC insertion site was 125, (29.83%), including mechanical skin injury (73, 17.42%), contact dermatitis (CD) (39, 9.31%), moisture-associated skin damage (11, 2.63%), folliculitis (2, 0.48%). Multivariate analysis identified two independent risk factors for MARSI including age ≥50 y (p = 0.031, odds ratio [OR] = 4.521, 95% confidence interval [CI] [1.389, 20.620]) and hematologic malignancies (p = 0.000, OR = 2.514, 95% CI [1.590,3.97]. Oxaliplatin and arsenic trioxide infusion through PICC, history of skin allergies was associated with CD, with p = 0.020, OR = 3.492, 95% CI (1.220, 9.990); p = 0.003, OR = 4.565, 95% CI (1.661,12.547); p = 0.000, OR = 12.333, 95% CI (3.669, 41.454), respectively. Conclusions: MARSI at PICC insertion site is a frequent event among oncology patients. Epidemiological data and independent risk factors are presented in our study, which provide a basis for future study in this area.
Collapse
|
12
|
Velasquez Reyes DC, Bloomer M, Morphet J. Prevention of central venous line associated bloodstream infections in adult intensive care units: A systematic review. Intensive Crit Care Nurs 2017; 43:12-22. [PMID: 28663107 DOI: 10.1016/j.iccn.2017.05.006] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 05/03/2017] [Accepted: 05/23/2017] [Indexed: 01/10/2023]
Abstract
BACKGROUND In adult Intensive Care Units, the complexity of patient treatment requirements make the use of central venous lines essential. Despite the potential benefits central venous lines can have for patients, there is a high risk of bloodstream infection associated with these catheters. AIM Identify and critique the best available evidence regarding interventions to prevent central venous line associated bloodstream infections in adult intensive care unit patients other than anti-microbial catheters. METHODS A systematic review of studies published from January 2007 to February 2016 was undertaken. A systematic search of seven databases was carried out: MEDLINE; CINAHL Plus; EMBASE; PubMed; Cochrane Library; Scopus and Google Scholar. Studies were critically appraised by three independent reviewers prior to inclusion. RESULTS Nineteen studies were included. A range of interventions were found to be used for the prevention or reduction of central venous line associated bloodstream infections. These interventions included dressings, closed infusion systems, aseptic skin preparation, central venous line bundles, quality improvement initiatives, education, an extra staff in the Intensive Care Unit and the participation in the 'On the CUSP: Stop Blood Stream Infections' national programme. CONCLUSIONS Central venous line associated bloodstream infections can be reduced by a range of interventions including closed infusion systems, aseptic technique during insertion and management of the central venous line, early removal of central venous lines and appropriate site selection.
Collapse
Affiliation(s)
| | - Melissa Bloomer
- Deakin University, School of Nursing and Midwifery, PO Box 20000, Geelong, VIC, AUS 3217, Australia
| | - Julia Morphet
- Monash University, School of Nursing and Midwifery Peninsula campus, McMahons Road, Frankston VIC, 3199, Australia
| |
Collapse
|
13
|
Takashima M, Ray-Barruel G, Ullman A, Keogh S, Rickard CM. Randomized controlled trials in central vascular access devices: A scoping review. PLoS One 2017; 12:e0174164. [PMID: 28323880 PMCID: PMC5360326 DOI: 10.1371/journal.pone.0174164] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Accepted: 03/03/2017] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Randomized controlled trials evaluate the effectiveness of interventions for central venous access devices, however, high complication rates remain. Scoping reviews map the available evidence and demonstrate evidence deficiencies to focus ongoing research priorities. METHOD A scoping review (January 2006-December 2015) of randomized controlled trials evaluating the effectiveness of interventions to improve central venous access device outcomes; including peripherally inserted central catheters, non-tunneled, tunneled and totally implanted venous access catheters. MeSH terms were used to undertake a systematic search with data extracted by two independent researchers, using a standardized data extraction form. RESULTS In total, 178 trials were included (78 non-tunneled [44%]; 40 peripherally inserted central catheters [22%]; 20 totally implanted [11%]; 12 tunneled [6%]; 6 non-specified [3%]; and 22 combined device trials [12%]). There were 119 trials (68%) involving adult participants only, with 18 (9%) pediatric and 20 (11%) neonatal trials. Insertion-related themes existed in 38% of trials (67 RCTs), 35 RCTs (20%) related to post-insertion patency, with fewer trials on infection prevention (15 RCTs, 8%), education (14RCTs, 8%), and dressing and securement (12 RCTs, 7%). There were 46 different study outcomes reported, with the most common being infection outcomes (161 outcomes; 37%), with divergent definitions used for catheter-related bloodstream and other infections. CONCLUSION More high quality randomized trials across central venous access device management are necessary, especially in dressing and securement and patency. These can be encouraged by having more studies with multidisciplinary team involvement and consumer engagement. Additionally, there were extensive gaps within population sub-groups, particularly in tunneled devices, and in pediatrics and neonates. Finally, outcome definitions need to be unified for results to be meaningful and comparable across studies.
Collapse
Affiliation(s)
- Mari Takashima
- Alliance for Vascular Access Teaching and Research (AVATAR) group, Menzies Health Institute Queensland, Griffith University, Nathan, Queensland, Australia
| | - Gillian Ray-Barruel
- Alliance for Vascular Access Teaching and Research (AVATAR) group, Menzies Health Institute Queensland, Griffith University, Nathan, Queensland, Australia
| | - Amanda Ullman
- Alliance for Vascular Access Teaching and Research (AVATAR) group, Menzies Health Institute Queensland, Griffith University, Nathan, Queensland, Australia
| | - Samantha Keogh
- School of Nursing & Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology, Brisbane, Australia
| | - Claire M. Rickard
- Alliance for Vascular Access Teaching and Research (AVATAR) group, Menzies Health Institute Queensland, Griffith University, Nathan, Queensland, Australia
| |
Collapse
|
14
|
Matey L, Camp-Sorrell D. Venous Access Devices: Clinical Rounds. Asia Pac J Oncol Nurs 2016; 3:357-364. [PMID: 28083553 PMCID: PMC5214869 DOI: 10.4103/2347-5625.196480] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 10/17/2016] [Indexed: 12/29/2022] Open
Abstract
Nursing management of venous access devices (VADs) requires knowledge of current evidence, as well as knowledge of when evidence is limited. Do you know which practices we do based on evidence and those that we do based on institutional history or preference? This article will present complex VAD infection and occlusion complications and some of the controversies associated with them. Important strategies for identifying these complications, troubleshooting, and evaluating the evidence related to lack of blood return, malposition, infection, access and maintenance protocols, and scope of practice issues are presented.
Collapse
Affiliation(s)
- Laurl Matey
- Oncology Nursing Society, Pittsburgh, PA, USA
| | | |
Collapse
|
15
|
Ullman AJ, Cooke ML, Mitchell M, Lin F, New K, Long DA, Mihala G, Rickard CM. Dressing and securement for central venous access devices (CVADs): A Cochrane systematic review. Int J Nurs Stud 2016; 59:177-96. [PMID: 27222463 DOI: 10.1016/j.ijnurstu.2016.04.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 04/06/2016] [Accepted: 04/06/2016] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To compare the available dressing and securement devices for central venous access devices (CVADs). DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Wounds Group Specialised Register, the Cochrane Central Register of Controlled Trials, the Database of Abstracts of Reviews and of Effects, NHS Economic Evaluation Database, Ovid MEDLINE, CINAHL, EMBASE, clinical trial registries and reference lists of identified trials. REVIEW METHODS Studies evaluated the effects of dressing and securement devices for CVADs. All types of CVADs were included. Outcome measures were CVAD-related bloodstream infection, CVAD tip colonisation, entry and exit site infection, skin colonisation, skin irritation, failed CVAD securement, dressing condition and mortality. We used standard methodological approaches as expected by The Cochrane Collaboration. RESULTS We included 22 studies involving 7436 participants comparing nine different types of securement device or dressing. All included studies were at unclear or high risk of performance bias due to the different appearances of the dressings and securement devices. It is unclear whether there is a difference in the rate of CVAD-related bloodstream infection between securement with gauze and tape and standard polyurethane (RR 0.64, 95% CI 0.26 to 1.63, low quality evidence), or between chlorhexidine gluconate-impregnated dressings and standard polyurethane (RR 0.65, 95% CI 0.40 to 1.05, moderate quality evidence). There is high quality evidence that medication-impregnated dressings reduce the incidence of CVAD-related bloodstream infection relative to all other dressing types (RR 0.60, 95% CI 0.39 to 0.93). There is moderate quality evidence that chlorhexidine gluconate-impregnated dressings reduce the frequency of CVAD-related bloodstream infection per 1000 patient days compared with standard polyurethane dressings (RR 0.51, 95% CI 0.33 to 0.78). There is moderate quality evidence that catheter tip colonisation is reduced with chlorhexidine gluconate-impregnated dressings compared with standard polyurethane dressings (RR 0.58, 95% CI 0.47 to 0.73), but the relative effects of gauze and tape and standard polyurethane are unclear (RR 0.95, 95% CI 0.51 to 1.77, very low quality evidence). CONCLUSIONS Medication-impregnated dressing products reduce the incidence of CVAD-related bloodstream infection relative to all other dressing types. There is some evidence that chlorhexidine gluconate-impregnated dressings, relative to standard polyurethane dressings, reduce CVAD-related bloodstream infection for the outcomes of frequency of infection per 1000 patient days, risk of catheter tip colonisation and possibly risk of CVAD-related bloodstream infection. Most studies were conducted in intensive care unit settings. More, high quality research is needed regarding the relative effects of dressing and securement products for CVADs.
Collapse
Affiliation(s)
- Amanda J Ullman
- Alliance for Vascular Access Teaching and Research (AVATAR), NHMRC Centre of Research Excellence in Nursing, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia; Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Brisbane, Australia.
| | - Marie L Cooke
- Alliance for Vascular Access Teaching and Research (AVATAR), NHMRC Centre of Research Excellence in Nursing, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia
| | - Marion Mitchell
- Alliance for Vascular Access Teaching and Research (AVATAR), NHMRC Centre of Research Excellence in Nursing, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia; Intensive Care Unit, Princess Alexandra Hospital, Woolloongabba, Australia
| | - Frances Lin
- Alliance for Vascular Access Teaching and Research (AVATAR), NHMRC Centre of Research Excellence in Nursing, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia
| | - Karen New
- Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Brisbane, Australia; The University of Queensland, School of Nursing, Midwifery and Social Work, Brisbane, Australia
| | - Debbie A Long
- Alliance for Vascular Access Teaching and Research (AVATAR), NHMRC Centre of Research Excellence in Nursing, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia; Paediatric Intensive Care Unit, Lady Cilento Children's Hospital, South Brisbane, Australia
| | - Gabor Mihala
- Centre for Applied Health Economics, Menzies Health Institute Queensland, School of Medicine, Griffith University, Meadowbrook, Australia
| | - Claire M Rickard
- Alliance for Vascular Access Teaching and Research (AVATAR), NHMRC Centre of Research Excellence in Nursing, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia; Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Brisbane, Australia
| |
Collapse
|
16
|
Ullman AJ, Cooke ML, Mitchell M, Lin F, New K, Long DA, Mihala G, Rickard CM. Dressings and securement devices for central venous catheters (CVC). Cochrane Database Syst Rev 2015; 2015:CD010367. [PMID: 26358142 PMCID: PMC6457749 DOI: 10.1002/14651858.cd010367.pub2] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Central venous catheters (CVCs) play a vital role in the management of acute and chronic illness. Dressings and securement devices must ensure CVCs do not dislodge or fall out, provide a barrier protection from microbial colonisation and infection, and be comfortable for the patient. There is a large range of dressing and securement products available for clinicians to use. OBJECTIVES To compare the available dressing and securement devices for CVCs, in terms of catheter-related bloodstream infection (BSI), catheter colonisation, entry- and exit-site infection, skin colonisation, skin irritation, failed catheter securement, dressing condition and mortality. SEARCH METHODS In June 2015 we searched: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL); The Database of Abstracts of Reviews of Effects (DARE); NHS Economic Evaluation Database (NHSEED); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; EBSCO CINAHL; six clinical trial registries and reference lists of identified trials. There were no restrictions based on language or date of publication or study setting. SELECTION CRITERIA We included randomised controlled trials that evaluated the effects of dressing and securement devices for CVCs. All types of CVCs were included, i.e. short- and long-term CVCs, tunnelled and non-tunnelled, port-a-caths, haemodialysis catheters, and peripherally-inserted central catheters (PICCs). DATA COLLECTION AND ANALYSIS We used standard Cochrane Collaboration methods including independent review of titles and abstracts for relevance, data extraction, and risk of bias assessment of the included studies by two review authors. Results are expressed using risk ratio (RR) for categorical data with 95% confidence intervals (CIs). For outcomes best presented as a rate-per-time-period, rate ratios and standard errors have been used. We performed multiple treatment meta-analyses to rank the effectiveness of each intervention for each outcome. MAIN RESULTS We included 22 studies involving 7436 participants comparing nine different types of securement device or dressing. All included studies were at unclear or high risk of performance bias due to the different appearances of the dressings and securement devices. The extent of blinding of outcome assessment was unclear in most studies. The quality of evidence varied between different comparisons and outcomes. We mainly downgraded the quality of evidence for imprecision, indirectness, risk of bias and inconsistency.It is unclear whether there is a difference in the rate of catheter-related BSI between securement with gauze and tape and standard polyurethane (SPU) (RR 0.64, 95% CI 0.26 to 1.63, low quality evidence), or between chlorhexidine gluconate-impregnated (CGI) dressings and SPU (RR 0.65, 95% CI 0.40 to 1.05, moderate quality evidence). There is high quality evidence that medication-impregnated dressings reduce the incidence of catheter-related BSI relative to all other dressing types (RR 0.60, 95% CI 0.39 to 0.93).There is moderate quality evidence that CGI dressings reduce the frequency of catheter-related BSI per 1000 patient days compared with SPU dressings (RR 0.51, 95% CI 0.33 to 0.78).There is moderate quality evidence that catheter tip colonisation is reduced with CGI dressings compared with SPU dressings (RR 0.58, 95% CI 0.47 to 0.73), but the relative effects of gauze and tape and SPU are unclear (RR 0.95, 95% CI 0.51 to 1.77, very low quality evidence). It is unclear if there is a difference in rates of skin irritation or damage when CGI dressings are compared with SPU dressings (moderate quality evidence) (RR 11.17, 95% CI 0.84 to 149.48).A multiple treatment meta-analysis found sutureless securement devices as likely to be the most effective at reducing the incidence of catheter-related BSI (low quality evidence), with CGI dressings ranked second (low quality evidence). AUTHORS' CONCLUSIONS Medication-impregnated dressing products reduce the incidence of catheter-related BSI relative to all other dressing types. There is some evidence that CGI dressings, relative to SPU dressings, reduce catheter-related BSI for the outcomes of frequency of infection per 1000 patient days, risk of catheter tip colonisation and possibly risk of catheter-related BSI. A multiple treatment meta-analysis found that sutureless securement devices are likely to be the most effective at reducing catheter-related BSI though this is low quality evidence. Most studies were conducted in intensive care unit (ICU) settings. More, high quality research is needed regarding the relative effects of dressing and securement products for CVCs. Future research may adjust the estimates of effect for the products included in this review and is needed to assess the effectiveness of new products.
Collapse
Affiliation(s)
- Amanda J Ullman
- Griffith UniversityAlliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland170 Kessels RoadBrisbaneQueenslandAustralia4111
| | - Marie L Cooke
- Griffith UniversityAlliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland170 Kessels RoadBrisbaneQueenslandAustralia4111
| | - Marion Mitchell
- Griffith UniversityNHMRC Centre of Research Excellence in Nursing, Centre for Health Practice Innovation, Menzies Health Institute QueenslandBrisbaneQueenslandAustralia4102
| | - Frances Lin
- Griffith UniversityNHMRC Centre of Research Excellence in Nursing, Centre for Health Practice Innovation, Menzies Health Institute QueenslandBrisbaneQueenslandAustralia4102
| | - Karen New
- The University of Queensland, School of Nursing, Midwifery and Social WorkRBWH Campus, Butterfield StreetBrisbaneQueenslandAustralia4029
| | - Debbie A Long
- Children's Health Queensland, Lady Cilento Children's HospitalPaediatric Intensive Care Unit501 Stanley StreetSouth BrisbaneQueenslandAustralia4101
| | - Gabor Mihala
- School of Medicine, Griffith UniversityCentre for Applied Health Economics, Menzies Health Institute QueenslandUniversity DriveMeadowbrookQueenslandAustralia4131
| | - Claire M Rickard
- Griffith UniversityNational Centre of Research Excellence in Nursing, Menzies Health Institute QueenslandBrisbaneQueenslandAustralia4111
| | | |
Collapse
|