1
|
Boboila S, Okochi S, Banerjee D, Barton S, Street C, Zenilman AL, Wang Q, Gartrell RD, Saenger YM, Welch D, Wu CC, Kadenhe-Chiweshe A, Yamashiro DJ, Connolly EP. Combining immunotherapy with high-dose radiation therapy (HDRT) significantly inhibits tumor growth in a syngeneic mouse model of high-risk neuroblastoma. Heliyon 2023; 9:e17399. [PMID: 37408891 PMCID: PMC10319189 DOI: 10.1016/j.heliyon.2023.e17399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 06/11/2023] [Accepted: 06/15/2023] [Indexed: 07/07/2023] Open
Abstract
Purpose The mortality in patients with MYCN-amplified high-risk neuroblastoma remains greater than 50% despite advances in multimodal therapy. Novel therapies are urgently needed that requires preclinical evaluation in appropriate mice models. Combinatorial treatment with high-dose radiotherapy (HDRT) and immunotherapy has emerged as an effective treatment option in a variety of cancers. Current models of neuroblastoma do not recapitulate the anatomic and immune environment in which multimodal therapies can be effectively tested, and there is a need for an appropriate syngeneic neuroblastoma mice model to study interaction of immunotherapy with host immune cells. Here, we develop a novel syngeneic mouse model of MYCN-amplified neuroblastoma and report the relevance and opportunities of this model to study radiotherapy and immunotherapy. Materials and methods A syngeneic allograft tumor model was developed using the murine neuroblastoma cell line 9464D derived a tumor from TH-MYCN transgenic mouse. Tumors were generated by transplanting 1 mm3 portions of 9464D flank tumors into the left kidney of C57Bl/6 mice. We investigated the effect of combining HDRT with anti-PD1 antibody on tumor growth and tumor microenvironment. HDRT (8 Gy x 3) was delivered by the small animal radiation research platform (SARRP). Tumor growth was monitored by ultrasound. To assess the effect on immune cells tumors sections were co-imuunostained for six biomarkers using the Vectra multispectral imaging platform. Results Tumor growth was uniform and confined to the kidney in 100% of transplanted tumors. HDRT was largely restricted to the tumor region with minimal scattered out-of-field dose. Combinatorial treatment with HDRT and PD-1 blockade significantly inhibited tumor growth and prolonged mice survival. We observed augmented T-lymphocyte infiltration, especially CD3+CD8+ lymphocytes, in tumors of mice which received combination treatment. Conclusion We have developed a novel syngeneic mouse model of MYCN amplified high-risk neuroblastoma. We have utilized this model to show that combining immunotherapy with HDRT inhibits tumor growth and prolongs mice survival.
Collapse
Affiliation(s)
- Shuobo Boboila
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Shunpei Okochi
- Department of Surgery, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Debarshi Banerjee
- Department of Pediatrics, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Sunjay Barton
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Cherease Street
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Ariela L. Zenilman
- Department of Surgery, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Qi Wang
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Robyn D. Gartrell
- Department of Medicine, Columbia University Irving Medical Center, New York, NY 10032, USA
- Department of Pediatrics, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Yvonne M. Saenger
- Department of Pediatrics, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - David Welch
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Cheng-Chia Wu
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Angela Kadenhe-Chiweshe
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Darrell J. Yamashiro
- Department of Pediatrics, Columbia University Irving Medical Center, New York, NY 10032, USA
- Department of Pathology, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Eileen P. Connolly
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY 10032, USA
| |
Collapse
|
2
|
Biltekin F, Bäumer C, Esser J, Ghanem O, Ozyigit G, Timmermann B. Preclinical Dosimetry for Small Animal Radiation Research in Proton Therapy: A Feasibility Study. Int J Part Ther 2023; 10:13-22. [PMID: 37823014 PMCID: PMC10563666 DOI: 10.14338/ijpt-22-00035.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 02/10/2023] [Indexed: 10/13/2023] Open
Abstract
PURPOSE To evaluate the feasibility of the three-dimensional (3D) printed small animal phantoms in dosimetric verification of proton therapy for small animal radiation research. MATERIALS AND METHODS Two different phantoms were modeled using the computed-tomography dataset of real rat and tumor-bearing mouse, retrospectively. Rat phantoms were designed to accommodate both EBT3 film and ionization chamber. A subcutaneous tumor-bearing mouse phantom was only modified to accommodate film dosimetry. All phantoms were printed using polylactic-acid (PLA) filament. Optimal printing parameters were set to create tissue-equivalent material. Then, proton therapy plans for different anatomical targets, including whole brain and total lung irradiation in the rat phantom and the subcutaneous tumor model in the mouse phantom, were created using the pencil-beam scanning technique. Point dose and film dosimetry measurements were performed using 3D-printed phantoms. In addition, all phantoms were analyzed in terms of printing accuracy and uniformity. RESULTS Three-dimensionally printed phantoms had excellent uniformity over the external body, and printing accuracy was within 0.5 mm. According to our findings, two-dimensional dosimetry with EBT3 showed acceptable levels of γ passing rate for all measurements except for whole brain irradiation (γ passing rate, 89.8%). In terms of point dose analysis, a good agreement (<0.1%) was found between the measured and calculated point doses for all anatomical targets. CONCLUSION Three-dimensionally printed small animal phantoms show great potential for dosimetric verifications of clinical proton therapy for small animal radiation research.
Collapse
Affiliation(s)
- Fatih Biltekin
- Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara, Turkey
- West German Proton Therapy Centre Essen (WPE), Essen, Germany
| | - Christian Bäumer
- West German Proton Therapy Centre Essen (WPE), Essen, Germany
- West German Cancer Centre (WTZ), Essen, Germany
- German Cancer Consortium (DKTK), Heidelberg, Germany
- TU Dortmund University, Department of Physics, Dortmund, Germany
| | - Johannes Esser
- West German Proton Therapy Centre Essen (WPE), Essen, Germany
- West German Cancer Centre (WTZ), Essen, Germany
| | - Osamah Ghanem
- West German Proton Therapy Centre Essen (WPE), Essen, Germany
- West German Cancer Centre (WTZ), Essen, Germany
| | - Gokhan Ozyigit
- Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara, Turkey
| | - Beate Timmermann
- West German Proton Therapy Centre Essen (WPE), Essen, Germany
- West German Cancer Centre (WTZ), Essen, Germany
- German Cancer Consortium (DKTK), Heidelberg, Germany
- TU Dortmund University, Department of Physics, Dortmund, Germany
- Department of Particle Therapy, University Hospital Essen, Essen, Germany
| |
Collapse
|
3
|
Entezam A, Fielding A, Bradley D, Fontanarosa D. Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method. PLoS One 2023; 18:e0280765. [PMID: 36730280 PMCID: PMC9928120 DOI: 10.1371/journal.pone.0280765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 01/07/2023] [Indexed: 02/03/2023] Open
Abstract
Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
Collapse
Affiliation(s)
- Amir Entezam
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
- Translational Research Institute, The University of Queensland, Brisbane, QLD, Australia
- * E-mail:
| | - Andrew Fielding
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, Brisbane, QLD, Australia
| | - David Bradley
- Centre for Applied Physics and Radiation Technologies, Sunway University, PJ, Malaysia
- Department of Physics, University of Surrey, Guildford, United Kingdom
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
4
|
Entezam A, Fielding A, Moi D, Bradley D, Ratnayake G, Sim L, Kralik C, Fontanarosa D. Investigation of scattered dose in a mouse phantom model for pre-clinical dosimetry studies. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
5
|
Ankjærgaard C, Johansen A, von Staffeldt M, Andersen C, Madsen D, Behrens C. Irradiation of subcutaneous mouse tumors with a clinical linear accelerator validated by alanine dosimetry. RADIAT MEAS 2021. [DOI: 10.1016/j.radmeas.2021.106636] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
DiCarlo AL, Perez Horta Z, Rios CI, Satyamitra MM, Taliaferro LP, Cassatt DR. Study logistics that can impact medical countermeasure efficacy testing in mouse models of radiation injury. Int J Radiat Biol 2020; 97:S151-S167. [PMID: 32909878 PMCID: PMC7987915 DOI: 10.1080/09553002.2020.1820599] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 09/05/2019] [Accepted: 10/01/2019] [Indexed: 12/02/2022]
Abstract
PURPOSE To address confounding issues that have been noted in planning and conducting studies to identify biomarkers of radiation injury, develop animal models to simulate these injuries, and test potential medical countermeasures to mitigate/treat damage caused by radiation exposure. METHODS The authors completed an intensive literature search to address several key areas that should be considered before embarking on studies to assess efficacy of medical countermeasure approaches in mouse models of radiation injury. These considerations include: (1) study variables; (2) animal selection criteria; (3) animal husbandry; (4) medical management; and (5) radiation attributes. RESULTS It is important to select mouse strains that are capable of responding to the selected radiation exposure (e.g. genetic predispositions might influence radiation sensitivity and proclivity to certain phenotypes of radiation injury), and that also react in a manner similar to humans. Gender, vendor, age, weight, and even seasonal variations are all important factors to consider. In addition, the housing and husbandry of the animals (i.e. feed, environment, handling, time of day of irradiation and animal restraint), as well as the medical management provided (e.g. use of acidified water, antibiotics, routes of administration of drugs, consideration of animal numbers, and euthanasia criteria) should all be addressed. Finally, the radiation exposure itself should be tightly controlled, by ensuring a full understanding and reporting of the radiation source, dose and dose rate, shielding and geometry of exposure, while also providing accurate dosimetry. It is important to understand how all the above factors contribute to the development of radiation dose response curves for a given animal facility with a well-defined murine model. CONCLUSIONS Many potential confounders that could impact the outcomes of studies to assess efficacy of a medical countermeasure for radiation-induced injuries are addressed, and recommendations are made to assist investigators in carrying out research that is robust, reproducible, and accurate.
Collapse
Affiliation(s)
- Andrea L DiCarlo
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, MD, USA
| | - Zulmarie Perez Horta
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, MD, USA
| | - Carmen I Rios
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, MD, USA
| | - Merriline M Satyamitra
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, MD, USA
| | - Lanyn P Taliaferro
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, MD, USA
| | - David R Cassatt
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, MD, USA
| |
Collapse
|
7
|
Price G, Biglin ER, Collins S, Aitkinhead A, Subiel A, Chadwick AL, Cullen DM, Kirkby KJ, Schettino G, Tipping J, Robinson A. An open source heterogeneous 3D printed mouse phantom utilising a novel bone representative thermoplastic. Phys Med Biol 2020; 65:10NT02. [PMID: 32182592 PMCID: PMC10606941 DOI: 10.1088/1361-6560/ab8078] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 03/17/2020] [Indexed: 11/12/2022]
Abstract
The lack of rigorous quality standards in pre-clinical radiation dosimetry has renewed interest in the development of anthropomorphic phantoms. Using 3D printing customisable phantoms can be created to assess all parts of pre-clinical radiation research: planning, image guidance and treatment delivery. We present the full methodology, including material development and printing designs, for the production of a high spatial resolution, anatomically realistic heterogeneous small animal phantom. A methodology for creating and validating tissue equivalent materials is presented. The technique is demonstrated through the development of a bone-equivalent material. This material is used together with a soft-tissue mimicking ABS plastic filament to reproduce the corresponding structure geometries captured from a CT scan of a nude mouse. Air gaps are used to represent the lungs. Phantom validation was performed through comparison of the geometry and x-ray attenuation of CT images of the phantom and animal images. A 6.6% difference in the attenuation of the bone-equivalent material compared to the reference standard in softer beams (0.5 mm Cu HVL) rapidly decreases as the beam is hardened. CT imaging shows accurate (sub-millimetre) reproduction of the skeleton (Distance-To-Agreement 0.5 mm ± 0.4 mm) and body surface (0.7 mm ± 0.5 mm). Histograms of the voxel intensity profile of the phantom demonstrate suitable similarity to those of both the original mouse image and that of a different animal. We present an approach for the efficient production of an anthropomorphic phantom suitable for the quality assurance of pre-clinical radiotherapy. Our design and full methodology are provided as open source to encourage the pre-clinical radiobiology community to adopt a common QA standard.
Collapse
Affiliation(s)
- Gareth Price
- University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
- Authors contributed equally
- Author to whom any correspondence should be addressed
| | - Emma R Biglin
- University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
- Authors contributed equally
| | - Sean Collins
- National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
- Department of Physics, University of Surrey, Stag Hill, Guildford GU2 7XH, United Kingdom
| | - Adam Aitkinhead
- University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
| | - Anna Subiel
- National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
| | - Amy L Chadwick
- University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
| | - David, M Cullen
- School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Karen J Kirkby
- University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
| | - Giuseppe Schettino
- National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
- Department of Physics, University of Surrey, Stag Hill, Guildford GU2 7XH, United Kingdom
| | - Jill Tipping
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
| | - Andrew Robinson
- University of Manchester, Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Wilmslow Road, Manchester M20 4BX, United Kingdom
- National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
- School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| |
Collapse
|
8
|
Esplen N, Therriault-Proulx F, Beaulieu L, Bazalova-Carter M. Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments. Med Phys 2019; 46:5294-5303. [PMID: 31461781 DOI: 10.1002/mp.13790] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 08/16/2019] [Accepted: 08/16/2019] [Indexed: 01/14/2023] Open
Abstract
PURPOSE Dose verification in preclinical radiotherapy is often challenged by a lack of standardization in the techniques and technologies commonly employed along with the inherent difficulty of dosimetry associated with small-field kilovoltage sources. As a consequence, the accuracy of dosimetry in radiobiological research has been called into question. Fortunately, the development and characterization of realistic small-animal phantoms has emerged as an effective and accessible means of improving dosimetric accuracy and precision in this context. The application of three-dimensional (3D) printing, in particular, has enabled substantial improvements in the conformity of representative phantoms with respect to the small animals they are modeled after. In this study, our goal was to evaluate a fully 3D printed mouse phantom for use in preclinical treatment verification of sophisticated therapies for various anatomical targets of therapeutic interest. METHODS An anatomically realistic mouse phantom was 3D printed based on segmented microCT data of a tumor-bearing mouse. The phantom was modified to accommodate both laser-cut EBT3 radiochromic film within the mouse thorax and a plastic scintillator dosimeter (PSD), which may be placed within the brain, abdomen, or 1-cm flank subcutaneous tumor. Various treatments were delivered on an image-guided small-animal irradiator in order to determine the doses to isocenter using a PSD and validate lateral- and depth-dose distributions using film dosimeters. On-board cone-beam CT imaging was used to localize isocenter to the film plane or PSD active element prior to irradiation. The PSD irradiations comprised a 3 × 3 mm2 brain arc, 5 × 5 mm2 parallel-opposed pair (POP), and 5-beam 10 × 10 mm2 abdominal coplanar arrangement while two-dimensional (2D) film dose distributions were acquired using a 3 × 3 mm2 arc and both 5 × 5 and 10 × 10 mm2 3-beam coplanar plans. A validated Monte Carlo (MC) model of the source was used as to verify the accuracy of the film and PSD dose measurements. computer-aided design (CAD) geometries for the mouse phantom and dosimeters were imported directly into the MC code to allow for highly accurate reproduction of the physical experiment conditions. Experimental and MC-derived film data were co-registered and film dose profiles were compared for points above 90% of the dose maximum. Point dose measurements obtained with the PSD were similarly compared for each of the candidate (brain, abdomen, and tumor) treatment sites. RESULTS For each treatment configuration and anatomical target, the MC-calculated and measured doses met the proposed 5% agreement goal for dose accuracy in radiobiology experiments. The 2D film and MC dose distributions were successfully registered and mean doses for lateral profiles were found to agree to within 2.3% in all cases. Isocentric point-dose measurements taken with the PSD were similarly consistent, with a maximum percentage deviation of 3.2%. CONCLUSIONS Our study confirms the utility of 3D printed phantom design in providing accurate dose estimates for a variety of preclinical treatment paradigms. As a tool for pretreatment dose verification, the phantom may be of particular interest to researchers for its ability to facilitate precise dosimetry while fostering a reduction in cost for radiobiology experiments.
Collapse
Affiliation(s)
- Nolan Esplen
- Department of Physics and Astronomy, University of Victoria, Victoria, BC, V8P 5C2, Canada
| | - François Therriault-Proulx
- Departement de Radio-Oncologie and Centre de recherche du CHU de Quebec, CHU de Quebec, Quebec, QC, G1R 3S1, Canada
| | - Luc Beaulieu
- Departement de Radio-Oncologie and Centre de recherche du CHU de Quebec, CHU de Quebec, Quebec, QC, G1R 3S1, Canada.,Departement de physique and Centre de recherche sur le Cancer, Université Laval, Quebec, QC, G1V 0A6, Canada
| | | |
Collapse
|
9
|
Biglin ER, Price GJ, Chadwick AL, Aitkenhead AH, Williams KJ, Kirkby KJ. Preclinical dosimetry: exploring the use of small animal phantoms. Radiat Oncol 2019; 14:134. [PMID: 31366364 PMCID: PMC6670203 DOI: 10.1186/s13014-019-1343-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 07/22/2019] [Indexed: 11/16/2022] Open
Abstract
Preclinical radiotherapy studies using small animals are an indispensable step in the pathway from in vitro experiments to clinical implementation. As radiotherapy techniques advance in the clinic, it is important that preclinical models evolve to keep in line with these developments. The use of orthotopic tumour sites, the development of tissue-equivalent mice phantoms and the recent introduction of image-guided small animal radiation research platforms has enabled similar precision treatments to be delivered in the laboratory. These technological developments, however, are hindered by a lack of corresponding dosimetry standards and poor reporting of methodologies. Without robust and well documented preclinical radiotherapy quality assurance processes, it is not possible to ensure the accuracy and repeatability of dose measurements between laboratories. As a consequence current RT-based preclinical models are at risk of becoming irrelevant. In this review we explore current standardization initiatives, focusing in particular on recent developments in small animal irradiation equipment, 3D printing technology to create customisable tissue-equivalent dosimetry phantoms and combining these phantoms with commonly used detectors.
Collapse
Affiliation(s)
- Emma R Biglin
- Division of Cancer Sciences, University of Manchester, Manchester Cancer Research Centre, 3rd floor Proton Beam Therapy Centre, Oak Road, Manchester, M20 4BX, UK.
| | - Gareth J Price
- Division of Cancer Sciences, University of Manchester, Manchester Cancer Research Centre, 3rd floor Proton Beam Therapy Centre, Oak Road, Manchester, M20 4BX, UK.,The Christie NHS Foundation Trust, Manchester, UK
| | - Amy L Chadwick
- Division of Cancer Sciences, University of Manchester, Manchester Cancer Research Centre, 3rd floor Proton Beam Therapy Centre, Oak Road, Manchester, M20 4BX, UK.,The Christie NHS Foundation Trust, Manchester, UK
| | - Adam H Aitkenhead
- Division of Cancer Sciences, University of Manchester, Manchester Cancer Research Centre, 3rd floor Proton Beam Therapy Centre, Oak Road, Manchester, M20 4BX, UK.,The Christie NHS Foundation Trust, Manchester, UK
| | - Kaye J Williams
- Division of Pharmacy and Optometry, University of Manchester, Manchester, UK
| | - Karen J Kirkby
- Division of Cancer Sciences, University of Manchester, Manchester Cancer Research Centre, 3rd floor Proton Beam Therapy Centre, Oak Road, Manchester, M20 4BX, UK.,The Christie NHS Foundation Trust, Manchester, UK
| |
Collapse
|
10
|
Soultanidis G, Subiel A, Renard I, Reinhart AM, Green VL, Oelfke U, Archibald SJ, Greenman J, Tulk A, Walker A, Schettino G, Cawthorne CJ. Development of an anatomically correct mouse phantom for dosimetry measurement in small animal radiotherapy research. Phys Med Biol 2019; 64:12NT02. [PMID: 31082807 DOI: 10.1088/1361-6560/ab215b] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Significant improvements in radiotherapy are likely to come from biological rather than technical optimization, for example increasing tumour radiosensitivity via combination with targeted therapies. Such paradigms must first be evaluated in preclinical models for efficacy, and recent advances in small animal radiotherapy research platforms allow advanced irradiation protocols, similar to those used clinically, to be carried out in orthotopic models. Dose assessment in such systems is complex however, and a lack of established tools and methodologies for traceable and accurate dosimetry is currently limiting the capabilities of such platforms and slowing the clinical uptake of new approaches. Here we report the creation of an anatomically correct phantom, fabricated from materials with tissue-equivalent electron density, into which dosimetry detectors can be incorporated for measurement as part of quality control (QC). The phantom also allows training in preclinical radiotherapy planning and cross-institution validation of dose delivery protocols for small animal radiotherapy platforms without the need to sacrifice animals, with high reproducibility. Mouse CT data was acquired and segmented into soft tissue, bone and lung. The skeleton was fabricated using 3D printing, whilst lung was created using computer numerical control (CNC) milling. Skeleton and lung were then set into a surface-rendered mould and soft tissue material added to create a whole-body phantom. Materials for fabrication were characterized for atomic composition and attenuation for x-ray energies typically found in small animal irradiators. Finally cores were CNC milled to allow intracranial incorporation of bespoke detectors (alanine pellets) for dosimetry measurement.
Collapse
Affiliation(s)
- George Soultanidis
- Department of Biomedical Sciences, University of Hull, Hull, United Kingdom. Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States of America
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Esplen N, Alyaqoub E, Bazalova-Carter M. Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments. Med Phys 2018; 46:1030-1036. [PMID: 30488962 DOI: 10.1002/mp.13310] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 11/14/2018] [Accepted: 11/20/2018] [Indexed: 12/15/2022] Open
Abstract
PURPOSE The goal of this work was to design a realistic mouse phantom as a useful tool for accurate dosimetry in radiobiology experiments. METHODS A subcutaneous tumor-bearing mouse was scanned in a microCT scanner, its organs manually segmented and contoured. The resulting geometries were converted into a stereolithographic file format (STL) and sent to a multimaterial 3D printer. The phantom was split into two parts to allow for lung excavation and 3D-printed with an acrylic-like material and consisted of the main body (mass density ρ=1.18 g/cm3 ) and bone (ρ=1.20 g/cm3 ). The excavated lungs were filled with polystyrene (ρ=0.32 g/cm3 ). Three cavities were excavated to allow the placement of a 1-mm diameter plastic scintillator dosimeter (PSD) in the brain, the center of the body and a subcutaneous tumor. Additionally, a laser-cut Gafchromic film can be placed in between the two phantom parts for 2D dosimetric evaluation. The expected differences in dose deposition between mouse tissues and the mouse phantom for a 220-kVp beam delivered by the small animal radiation research platform (SARRP) were calculated by Monte Carlo (MC). RESULTS MicroCT scans of the phantom showed excellent material uniformity and confirmed the material densities given by the manufacturer. MC dose calculations revealed that the dose measured by tissue-equivalent dosimeters inserted into the phantom in the brain, abdomen, and subcutaneous tumor would be underestimated by 3-5%, which is deemed to be an acceptable error assuming the proposed 5% accuracy of radiobiological experiments. CONCLUSIONS The low-cost mouse phantom can be easily manufactured and, after a careful dosimetric characterization, may serve as a useful tool for dose verification in a range of radiobiology experiments.
Collapse
Affiliation(s)
- Nolan Esplen
- Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada
| | - Eisa Alyaqoub
- Department of Electrical Engineering, University of Victoria, Victoria, BC, Canada
| | | |
Collapse
|
12
|
Quality Assessment of Stereotactic Radiosurgery of a Melanoma Brain Metastases Model Using a Mouselike Phantom and the Small Animal Radiation Research Platform. Int J Radiat Oncol Biol Phys 2017; 99:191-201. [PMID: 28816146 DOI: 10.1016/j.ijrobp.2017.05.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 05/03/2017] [Accepted: 05/10/2017] [Indexed: 01/22/2023]
Abstract
PURPOSE To establish a novel preclinical model for stereotactic radiosurgery (SRS) with combined mouselike phantom quality assurance in the setting of brain metastases. METHODS AND MATERIALS C57B6 mice underwent intracranial injection of B16-F10 melanoma cells. T1-weighted postcontrast magnetic resonance imaging (MRI) was performed on day 11 after injection. The MRI images were fused with cone beam computed tomography (CBCT) images using the Small Animal Radiation Research Platform (SARRP). The gross tumor volume (GTV) was contoured using the MRI. A single sagittal arc using the 3 × 3 mm2 collimator was used to deliver 18 Gy prescribed to the isocenter. MRI was performed 7 days after radiation treatment, and the dose delivered to the mice was confirmed using 2 mouselike anthropomorphic phantoms: 1 in the axial orientation and the other in the sagittal orientation. The SARRP output was measured using a PTW Farmer type ionization chamber as per the American Association of Physicists in Medicine Task Group report 61, and the H-D curve was generated up to a maximum dose of 30 Gy. Irradiated films were analyzed based on optical density distribution and H-D curve. RESULTS The tumor volume on day 11, before intervention, was 2.48 ± 1.37 mm3 in the no-SRS arm versus 3.75 ± 1.19 mm3 in the SRS arm (NS). In the SRS arm, GTV maximum dose (Dmax) and mean dose were 2048 ± 207 and 1785 ± 14 cGy. Using the mouselike phantoms, the radiochromic film showed close precision in comparison with projected isodose lines, with a Dmax of 1903.4 and 1972.7 cGy, the axial and sagittal phantoms, respectively. Tumor volume 7 days after treatment was 7.34 ± 8.24 mm3 in the SRS arm and 60.20 ± 40.4 mm3 in the no-SRS arm (P=.009). No mice in the control group survived more than 22 days after implantation, with a median overall survival (mOS) of 19 days; mOS was not reached in the SRS group, with 1 death noted. CONCLUSIONS Single-fraction SRS of 18 Gy delivered in a single arc can be delivered accurately with MRI T1-weighted postcontrast-based treatment planning. The mouse like phantom allows for verification of dose delivery and accuracy.
Collapse
|