Höhler C, Trigili E, Astarita D, Hermsdörfer J, Jahn K, Krewer C. The efficacy of hybrid neuroprostheses in the rehabilitation of upper limb impairment after stroke, a narrative and systematic review with a meta-analysis. Artif Organs 2024; 48:232-253. [PMID: 37548237 DOI: 10.1111/aor.14618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 06/30/2023] [Accepted: 07/17/2023] [Indexed: 08/08/2023]
Abstract
BACKGROUND Paresis of the upper limb (UL) is the most frequent impairment after a stroke. Hybrid neuroprostheses, i.e., the combination of robots and electrical stimulation, have emerged as an option to treat these impairments. METHODS To give an overview of existing devices, their features, and how they are linked to clinical metrics, four different databases were systematically searched for studies on hybrid neuroprostheses for UL rehabilitation after stroke. The evidence on the efficacy of hybrid therapies was synthesized. RESULTS Seventy-three studies were identified, introducing 32 hybrid systems. Among the most recent devices (n = 20), most actively reinforce movement (3 passively) and are typical exoskeletons (3 end-effectors). If classified according to the International Classification of Functioning, Disability and Health, systems for proximal support are expected to affect body structures and functions, while the activity and participation level are targeted when applying Functional Electrical Stimulation distally plus the robotic component proximally. The meta-analysis reveals a significant positive effect on UL functions (p < 0.001), evident in a 7.8-point Mdiff between groups in the Fugl-Meyer assessment. This positive effect remains at the 3-month follow-up (Mdiff = 8.4, p < 0.001). CONCLUSIONS Hybrid neuroprostheses have a positive effect on UL recovery after stroke, with effects persisting at least three months after the intervention. Non-significant studies were those with the shortest intervention periods and the oldest patients. Improvements in UL functions are not only present in the subacute phase after stroke but also in long-term chronic stages. In addition to further technical development, more RCTs are needed to make assumptions about the determinants of successful therapy.
Collapse
Affiliation(s)
- Chiara Höhler
- Research Department, Schoen Clinic Bad Aibling, Bad Aibling, Germany
- Chair of Human Movement Science, Faculty of Sport and Health Science, Technical University Munich, Munich, Germany
| | - Emilio Trigili
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Davide Astarita
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Joachim Hermsdörfer
- Chair of Human Movement Science, Faculty of Sport and Health Science, Technical University Munich, Munich, Germany
| | - Klaus Jahn
- Research Department, Schoen Clinic Bad Aibling, Bad Aibling, Germany
- German Center for Vertigo and Balance Disorders (DSGZ), Ludwig-Maximilians University of Munich (LMU), Munich, Germany
| | - Carmen Krewer
- Research Department, Schoen Clinic Bad Aibling, Bad Aibling, Germany
- Chair of Human Movement Science, Faculty of Sport and Health Science, Technical University Munich, Munich, Germany
| |
Collapse
|
2
|
Herrera-Valenzuela D, Díaz-Peña L, Redondo-Galán C, Arroyo MJ, Cascante-Gutiérrez L, Gil-Agudo Á, Moreno JC, Del-Ama AJ. A qualitative study to elicit user requirements for lower limb wearable exoskeletons for gait rehabilitation in spinal cord injury. J Neuroeng Rehabil 2023; 20:138. [PMID: 37848992 PMCID: PMC10583355 DOI: 10.1186/s12984-023-01264-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 10/10/2023] [Indexed: 10/19/2023] Open
Abstract
OBJECTIVE We aim to determine a comprehensive set of requirements, perceptions, and expectations that people with spinal cord injury (SCI) and the clinicians in charge of their rehabilitation have regarding the use of wearable robots (WR) for gait rehabilitation. BACKGROUND There are concerns due to the limited user acceptance of WR for gait rehabilitation. Developers need to emphasize understanding the needs and constraints of all stakeholders involved, including the real-life dynamics of rehabilitation centers. METHODS 15 people with SCI, 9 without experience with WR and 6 with experience with these technologies, and 10 clinicians from 3 rehabilitation centers in Spain were interviewed. A directed content analysis approach was used. RESULTS 78 codes grouped into 9 categories (physical results, usability, psychology-related codes, technical characteristics, activities, acquisition issues, context of use, development of the technologies and clinical rehabilitation context) were expressed by at least 20% of the users interviewed, of whom 16 were not found in the literature. The agreement percentage between each group and subgroup included in the study, calculated as the number of codes that more than 20% of both groups expressed, divided over the total amount of codes any of those two groups agreed on (≥ 20%), showed limited agreement between patients and clinicians (50.00%) and between both types of patients (55.77%). The limited accessibility and availability of lower limb exoskeletons for gait rehabilitation arose in most of the interviews. CONCLUSIONS The limited agreement percentage between patients and clinicians indicates that including both types of users in the design process of these technologies is important, given that their requirements are complementary. Engaging users with prior technology experience is recommended, as they often exhibit strong internal consensus and articulate well-defined requirements. This study adds up the knowledge available in the literature and the new codes found in our data, which enlighten important aspects that ought to be addressed in the field to develop technologies that respond to users' needs, are usable and feasible to implement in their intended contexts. APPLICATION The set of criteria summarized in our study will be useful to guide the design, development, and evaluation of WR for gait rehabilitation to meet user's needs and allow them to be implemented in their intended context of use.
Collapse
Affiliation(s)
- Diana Herrera-Valenzuela
- International Doctoral School, Rey Juan Carlos University, Madrid, Spain.
- Biomechanics and Technical Aids Unit, National Hospital for Paraplegics, Toledo, Spain.
| | - Laura Díaz-Peña
- Biomedical Engineering Department, Superior Technical School of Telecommunications Engineering, Rey Juan Carlos University, Fuenlabrada, Madrid, Spain
| | - Carolina Redondo-Galán
- Physical Medicine and Rehabilitation Department, National Hospital for Paraplegics, Toledo, Spain
| | - María José Arroyo
- Fundación del Lesionado Medular (Spinal Cord Injured Foundation), Madrid, Spain
| | | | - Ángel Gil-Agudo
- Biomechanics and Technical Aids Unit, National Hospital for Paraplegics, Toledo, Spain
- Physical Medicine and Rehabilitation Department, National Hospital for Paraplegics, Toledo, Spain
- Unit of Neurorehabilitation, Biomechanics and Sensorimotor Function (HNP-SESCAM), Associated Unit of R&D&I to the CSIC, Toledo, Spain
| | - Juan C Moreno
- Unit of Neurorehabilitation, Biomechanics and Sensorimotor Function (HNP-SESCAM), Associated Unit of R&D&I to the CSIC, Toledo, Spain
- Neural Rehabilitation Group, Cajal Institute, CSIC-Spanish National Research Council, Madrid, Spain
| | - Antonio J Del-Ama
- School of Science and Technology, Department of Applied Mathematics, Materials Science and Engineering and Electronic Technology, Rey Juan Carlos University, Móstoles, Madrid, Spain
| |
Collapse
|
3
|
Basla C, Chee L, Valle G, Crema A, Micera S, Riener R, Raspopovic S. Sensory-Motor Neurostimulation to Enhance Exosuit Performance. IEEE Int Conf Rehabil Robot 2023; 2023:1-6. [PMID: 37941243 DOI: 10.1109/icorr58425.2023.10304701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
Exosuits typically provide limited mechanical support and rely on a user's residual functional ability. However, people with neurological impairments often suffer from both motor and sensory deficits that limit the assistance an exosuit can provide. To overcome these limitations, we developed the REINFORCE system, that complements the mechanical assistance provided by an exosuit, the Myosuit, with (1) functional electrical stimulation to enhance the activities of leg muscles, and (2) transcutaneous electrical nerve stimulation to restore somatosensory information. It consists of a fully portable and highly modular system that can be easily adapted to the level of impairment and specific need of each participant. Technical verification with three healthy participants showed reliable synchronization between all modules of the systems in all phases of walking. Additionally, we tested the system's effectiveness in one participant with multiple sclerosis who walked overground with and without functional electrical stimulation. Results showed a slight increase in self-selected walking speed (approx. 18%) and in the peak hip flexion at late swing (approx. 12%) as well as reduced step-to-step variability of step length and step time when electrical stimulation was provided. Our findings push towards a clinical trial involving more patients to validate the effectiveness of the REINFORCE system on participants' mobility.
Collapse
|
4
|
Ivanenko Y, Shapkova EY, Petrova DA, Kleeva DF, Lebedev MA. Exoskeleton gait training with spinal cord neuromodulation. Front Hum Neurosci 2023; 17:1194702. [PMID: 37250689 PMCID: PMC10213721 DOI: 10.3389/fnhum.2023.1194702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 04/27/2023] [Indexed: 05/31/2023] Open
Abstract
Neuromodulating the locomotor network through spinal cord electrical stimulation (SCES) is effective for restoring function in individuals with gait deficits. However, SCES alone has limited effectiveness without concurrent locomotor function training that enhances activity-dependent plasticity of spinal neuronal networks by sensory feedback. This mini review discusses recent developments in using combined interventions, such as SCES added to exoskeleton gait training (EGT). To develop personalized therapies, it is crucial to assess the state of spinal circuitry through a physiologically relevant approach that identifies individual characteristics of spinal cord function to develop person-specific SCES and EGT. The existing literature suggests that combining SCES and EGT to activate the locomotor network can have a synergistic rehabilitative effect on restoring walking abilities, somatic sensation, and cardiovascular and bladder function in paralyzed individuals.
Collapse
Affiliation(s)
| | - Elena Y. Shapkova
- Saint-Petersburg State Research Institute of Phthisiopulmonology, Saint Petersburg, Russia
- Institute of Translational Biomedicine, St. Petersburg State University, Saint Petersburg, Russia
| | - Daria A. Petrova
- Vladimir Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
| | - Daria F. Kleeva
- Vladimir Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
| | - Mikhail A. Lebedev
- Faculty of Mechanics and Mathematics, Lomonosov Moscow State University, Moscow, Russia
- Sechenov Institute of Evolutionary Physiology and Biochemistry of the Russian Academy of Sciences, Saint Petersburg, Russia
| |
Collapse
|
5
|
Radeleczki B, Mravcsik M, Bozheim L, Laczko J. Prediction of leg muscle activities from arm muscle activities in arm and leg cycling. Anat Rec (Hoboken) 2023; 306:710-719. [PMID: 35712823 DOI: 10.1002/ar.25004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/31/2022] [Accepted: 05/05/2022] [Indexed: 11/06/2022]
Abstract
Functional electrical stimulation (FES) driven leg cycling is usually controlled by previously established stimulation patterns. We investigated the potential utilization of a particular computational method for controlling electrical stimulation of lower limb muscles by real-time electromyography (EMG) signals of arm muscles during hybrid arm and leg cycling. In hybrid arm and leg cycling, arm cranking is performed voluntarily, while leg cycling is driven by FES. In this study, we investigate arm and leg cycling movements of able-bodied persons when both arm and leg cycling is performed voluntarily without FES. We present a neural network-based model in which the input of the neural network is given by a time series of upper limb muscle activities (EMG), and the output provides potential lower limb muscle activities. The particular neural network was a nonlinear autoregressive exogen (NARX) neural network. The measured EMG signals of the lower limb muscles were compared to the signals that were predicted by the neural network. The neural network was trained with data recorded from four participants. Our preliminary results show notable differences between the predicted and the experimentally measured lower limb muscle activities. The prediction was good only for 60% of the movement time. We conclude that-while including arm cycling in the movement-simpler control modalities or further consideration of applying machine-learning techniques has to be taken into account to improve voluntary upper limb-controlled FES assisted leg cycling.
Collapse
Affiliation(s)
- Balazs Radeleczki
- Pázmány Péter Catholic University, Faculty of Information Technology and Bionics, Budapest, Hungary
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, Hungary
| | - Mariann Mravcsik
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, Hungary
- Department of Information Technology and Biorobotics, Faculty of Sciences, University of Pécs, Pécs, Hungary
| | - Lilla Bozheim
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, Hungary
- Department of Information Technology and Biorobotics, Faculty of Sciences, University of Pécs, Pécs, Hungary
| | - Jozsef Laczko
- Pázmány Péter Catholic University, Faculty of Information Technology and Bionics, Budapest, Hungary
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, Hungary
- Department of Information Technology and Biorobotics, Faculty of Sciences, University of Pécs, Pécs, Hungary
- Department of Neuroscience, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
6
|
Siviy C, Baker LM, Quinlivan BT, Porciuncula F, Swaminathan K, Awad LN, Walsh CJ. Opportunities and challenges in the development of exoskeletons for locomotor assistance. Nat Biomed Eng 2022; 7:456-472. [PMID: 36550303 DOI: 10.1038/s41551-022-00984-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 11/08/2022] [Indexed: 12/24/2022]
Abstract
Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology.
Collapse
Affiliation(s)
- Christopher Siviy
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Lauren M Baker
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Brendan T Quinlivan
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Franchino Porciuncula
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.,Department of Physical Therapy, College of Health and Rehabilitation Sciences: Sargent, Boston University, Boston, MA, USA
| | - Krithika Swaminathan
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Louis N Awad
- Department of Physical Therapy, College of Health and Rehabilitation Sciences: Sargent, Boston University, Boston, MA, USA
| | - Conor J Walsh
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.
| |
Collapse
|
7
|
Molazadeh V, Zhang Q, Bao X, Sharma N. An Iterative Learning Controller for a Switched Cooperative Allocation Strategy during Sit-to-Stand Tasks with a Hybrid Exoskeleton. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY : A PUBLICATION OF THE IEEE CONTROL SYSTEMS SOCIETY 2022; 30:1021-1036. [PMID: 36249864 PMCID: PMC9560042 DOI: 10.1109/tcst.2021.3089885] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A hybrid exoskeleton that combines functional electrical stimulation (FES) and a powered exoskeleton is an emerging technology for assisting people with mobility disorders. The cooperative use of FES and the exoskeleton allows active muscle contractions via FES while robustifying torque generation to reduce FES-induced muscle fatigue. In this paper, a switched distribution of allocation ratios between FES and electric motors in a closed-loop adaptive control design is explored for the first time. The new controller uses an iterative learning neural network (NN)-based control law to compensate for structured and unstructured parametric uncertainties in the hybrid exoskeleton model. A discrete Lyapunov-like stability analysis that uses a common energy function proves asymptotic stability for the switched system with iterative learning update laws. Five human participants, including a person with complete spinal cord injury, performed sit-to-stand tasks with the new controller. The experimental results showed that the synthesized controller, in a few iterations, reduced the root mean square error between desired positions and actual positions of the knee and hip joints by 46.20% and 53.34%, respectively. The sit-to-stand experimental results also show that the proposed NN-based iterative learning control (NNILC) approach can recover the asymptotically trajectory tracking performance despite the switching of allocation levels between FES and electric motor. Compared to a proportional-derivative controller and traditional iterative learning control, the findings showed that the new controller can potentially simplify the clinical implementation of the hybrid exoskeleton with minimal parameters tuning.
Collapse
Affiliation(s)
- Vahidreza Molazadeh
- Department of Mechanical Engineering and Materials Science at University of Pittsburgh, Pittsburgh, PA, USA
| | - Qiang Zhang
- Joint Department of Biomedical Engineering at North Carolina State University and the University of North Carolina Chapel-Hill, Raleigh, NC, USA
| | - Xuefeng Bao
- Department of Biomedical Engineering at Case Western Reserve University, Cleveland, OH, USA
| | - Nitin Sharma
- Joint Department of Biomedical Engineering at North Carolina State University and the University of North Carolina Chapel-Hill, Raleigh, NC, USA
| |
Collapse
|
8
|
Active Assistive Design and Multiaxis Self-Tuning Control of a Novel Lower Limb Rehabilitation Exoskeleton. MACHINES 2022. [DOI: 10.3390/machines10050318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
This paper presented the mechanical design and control of a lower limb rehabilitation exoskeleton named “the second lower limb rehabilitation exoskeleton (LLRE-II)”. The exoskeleton with a lightweight mechanism comprises a 16-cm stepless adjustable thigh and calf rod. The LLRE-II weighs less than 16 kg and has four degrees of freedom on each leg, including the waist, hip, knee, and ankle, which ensures fitted wear and comfort. Motors and harmonic drives were installed on the joints of the hip and knee to operate the exoskeleton. Meanwhile, master and slave motor controllers were programmed using a Texas Instruments microcontroller (TMS320F28069) for the walking gait commands and evaluation boards (TMS320F28069/DRV8301) of the joints. A self-tuning multiaxis control system was developed, and the performance of the controller was investigated through experiments. The experimental results showed that the mechanical design and control system exhibit adequate performance. Trajectory tracking errors were eliminated, and the root mean square errors reduced from 6.45 to 1.22 and from 4.15 to 3.09 for the hip and knee, respectively.
Collapse
|
9
|
Biologically Inspired Optimal Terminal Iterative Learning Control for the Swing Phase of Gait in a Hybrid Neuroprosthesis: A Modeling Study. Bioengineering (Basel) 2022; 9:bioengineering9020071. [PMID: 35200424 PMCID: PMC8869465 DOI: 10.3390/bioengineering9020071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 01/21/2022] [Accepted: 02/08/2022] [Indexed: 11/17/2022] Open
Abstract
(1) Background: An iterative learning control (ILC) strategy was developed for a “Muscle First” Motor-Assisted Hybrid Neuroprosthesis (MAHNP). The MAHNP combines a backdrivable exoskeletal brace with neural stimulation technology to enable persons with paraplegia due to spinal cord injury (SCI) to execute ambulatory motions and walk upright. (2) Methods: The ILC strategy was developed to swing the legs in a biologically inspired ballistic fashion. It maximizes muscular recruitment and activates the motorized exoskeletal bracing to assist the motion as needed. The control algorithm was tested using an anatomically realistic three-dimensional musculoskeletal model of the lower leg and pelvis suitably modified to account for exoskeletal inertia. The model was developed and tested with the OpenSim biomechanical modeling suite. (3) Results: Preliminary data demonstrate the efficacy of the controller in swing-leg simulations and its ability to learn to balance muscular and motor contributions to improve performance and accomplish consistent stepping. In particular, the controller took 15 iterations to achieve the desired outcome with 0.3% error.
Collapse
|
10
|
de Sousa ACC, Bó AP. Simulation studies on hybrid neuroprosthesis control strategies for gait at low speeds. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102970] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
11
|
Shon A, Brakel K, Hook M, Park H. Fully Implantable Plantar Cutaneous Augmentation System for Rats Using Closed-loop Electrical Nerve Stimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:326-338. [PMID: 33861705 DOI: 10.1109/tbcas.2021.3072894] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Plantar cutaneous feedback plays an important role in stable and efficient gait, by modulating the activity of ankle dorsi- and plantar-flexor muscles. However, central and peripheral nervous system trauma often decrease plantar cutaneous feedback and/or interneuronal excitability in processing the plantar cutaneous feedback. In this study, we tested a fully implantable neural recording and stimulation system augmenting plantar cutaneous feedback. Electromyograms were recorded from the medial gastrocnemius muscle for stance phase detection, while biphasic stimulation pulses were applied to the distal-tibial nerve during the stance phase to augment plantar cutaneous feedback. A Bluetooth low energy and a Qi-standard inductive link were adopted for wireless communication and wireless charging, respectively. To test the operation of the system, one intact rat walked on a treadmill with the electrical system implanted into its back. Leg kinematics were recorded to identify the stance phase. Stimulation was applied, with a 250-ms onset delay from stance onset and 200-ms duration, resulting in the onset at 47.58 ± 2.82% of stance phase and the offset at 83.49 ± 4.26% of stance phase (Mean ± SEM). The conduction velocity of the compound action potential (31.2 m/s and 41.6 m/s at 1·T and 2·T, respectively) suggests that the evoked action potential was characteristic of an afferent volley for cutaneous feedback. We also demonstrated successful wireless charging and system reset functions. The experimental results suggest that the presented implantable system can be a valuable neural interface tool to investigate the effect of plantar cutaneous augmentation on gait in a rat model.
Collapse
|
12
|
Reyes RD, Kobetic R, Nandor M, Makowski N, Audu M, Quinn R, Triolo R. Effect of Joint Friction Compensation on a "Muscle-First" Motor-Assisted Hybrid Neuroprosthesis. Front Neurorobot 2020; 14:588950. [PMID: 33362502 PMCID: PMC7759638 DOI: 10.3389/fnbot.2020.588950] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Accepted: 11/12/2020] [Indexed: 11/21/2022] Open
Abstract
This study assessed the metabolic energy consumption of walking with the external components of a “Muscle-First” Motor Assisted Hybrid Neuroprosthesis (MAHNP), which combines implanted neuromuscular stimulation with a motorized exoskeleton. The “Muscle-First” approach prioritizes generating motion with the wearer's own muscles via electrical stimulation with the actuators assisting on an as-needed basis. The motorized exoskeleton contributes passive resistance torques at both the hip and knee joints of 6Nm and constrains motions to the sagittal plane. For the muscle contractions elicited by neural stimulation to be most effective, the motorized joints need to move freely when not actively assisting the desired motion. This study isolated the effect of the passive resistance or “friction” added at the joints by the assistive motors and transmissions on the metabolic energy consumption of walking in the device. Oxygen consumption was measured on six able-bodied subjects performing 6 min walk tests at three different speeds (0.4, 0.8, and 1.2 m/s) under two different conditions: one with the motors producing no torque to compensate for friction, and the other having the motors injecting power to overcome passive friction based on a feedforward friction model. Average oxygen consumption in the uncompensated condition across all speeds, measured in Metabolic Equivalent of Task (METs), was statistically different than the friction compensated condition. There was an average decrease of 8.8% for METs and 1.9% for heart rate across all speeds. While oxygen consumption was reduced when the brace performed friction compensation, other factors may have a greater contribution to the metabolic energy consumption when using the device. Future studies will assess the effects of gravity compensation on the muscular effort required to lift the weight of the distal segments of the exoskeleton as well as the sagittal plane constraint on walking motions in individuals with spinal cord injuries (SCI).
Collapse
Affiliation(s)
- Ryan-David Reyes
- Advanced Platform Technology Center, Department of Veterans Affairs, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States.,Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Rudolf Kobetic
- Advanced Platform Technology Center, Department of Veterans Affairs, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Mark Nandor
- Advanced Platform Technology Center, Department of Veterans Affairs, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States.,Department of Mechanical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Nathaniel Makowski
- Advanced Platform Technology Center, Department of Veterans Affairs, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States.,Department of Physical Medicine & Rehabilitation, MetroHealth Medical Center, Cleveland, OH, United States
| | - Musa Audu
- Advanced Platform Technology Center, Department of Veterans Affairs, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States.,Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Roger Quinn
- Department of Mechanical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Ronald Triolo
- Advanced Platform Technology Center, Department of Veterans Affairs, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States.,Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| |
Collapse
|
13
|
Abu-Dakka FJ, Valera A, Escalera JA, Abderrahim M, Page A, Mata V. Passive Exercise Adaptation for Ankle Rehabilitation Based on Learning Control Framework. SENSORS 2020; 20:s20216215. [PMID: 33142669 PMCID: PMC7662251 DOI: 10.3390/s20216215] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 10/14/2020] [Accepted: 10/26/2020] [Indexed: 11/16/2022]
Abstract
Ankle injuries are among the most common injuries in sport and daily life. However, for their recovery, it is important for patients to perform rehabilitation exercises. These exercises are usually done with a therapist's guidance to help strengthen the patient's ankle joint and restore its range of motion. However, in order to share the load with therapists so that they can offer assistance to more patients, and to provide an efficient and safe way for patients to perform ankle rehabilitation exercises, we propose a framework that integrates learning techniques with a 3-PRS parallel robot, acting together as an ankle rehabilitation device. In this paper, we propose to use passive rehabilitation exercises for dorsiflexion/plantar flexion and inversion/eversion ankle movements. The therapist is needed in the first stage to design the exercise with the patient by teaching the robot intuitively through learning from demonstration. We then propose a learning control scheme based on dynamic movement primitives and iterative learning control, which takes the designed exercise trajectory as a demonstration (an input) together with the recorded forces in order to reproduce the exercise with the patient for a number of repetitions defined by the therapist. During the execution, our approach monitors the sensed forces and adapts the trajectory by adding the necessary offsets to the original trajectory to reduce its range without modifying the original trajectory and subsequently reducing the measured forces. After a predefined number of repetitions, the algorithm restores the range gradually, until the patient is able to perform the originally designed exercise. We validate the proposed framework with both real experiments and simulation using a Simulink model of the rehabilitation parallel robot that has been developed in our lab.
Collapse
Affiliation(s)
- Fares J. Abu-Dakka
- Intelligent Robotics Group, Department of Electrical Engineering and Automation (EEA), Aalto University, 02150 Espoo, Finland
- Correspondence:
| | - Angel Valera
- Instituto Universitario de Automática e Informática Industrial (ai2), Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Juan A. Escalera
- Instituto Nacional de Técnica Aeroespacial (INTA), 28330 San Martín de la Vega, Spain;
| | - Mohamed Abderrahim
- Department of Systems Engineering and Automation, Carlos III University of Madrid, 28911 Leganés, Spain;
| | - Alvaro Page
- Instituto Universitario de Ingeniería Mecánica y Biomecánica, Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Vicente Mata
- Departamento de Ingeniería Mecánica y de Materiales, Universitat Politècnica de València, 46022 Valencia, Spain;
| |
Collapse
|
14
|
Thorp JE, Adamczyk PG. Mechanisms of gait phase entrainment in healthy subjects during rhythmic electrical stimulation of the medial gastrocnemius. PLoS One 2020; 15:e0241339. [PMID: 33095823 PMCID: PMC7584166 DOI: 10.1371/journal.pone.0241339] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 10/13/2020] [Indexed: 01/14/2023] Open
Abstract
Studies have shown that human gait entrains to rhythmic bursts of ankle torque for perturbation intervals both slightly shorter and slightly longer than the natural stride period while walking on a treadmill and during overground walking, with phase alignment such that the torque adds to ankle push-off. This study investigated whether human gait also entrains to align the phase of rhythmic electrical stimulation of the gastrocnemius muscle with the timing of ankle push-off. In addition, this study investigated the muscle response to electrical stimulation at different phases of the gait cycle. We found that for both treadmill and overground walking entrainment was observed with phasing that aligned the stimuli with ankle push-off or just before foot contact. Achilles tendon wave speed measurements showed a significant difference (increase) in tendon load when electrical stimulation was applied just after foot contact and during swing phase, with a greater increase for higher amplitudes of electrical stimulation. However, stimulation did not increase tendon load when the timing coincided with push-off. Stride period measurements also suggest the effect of electrical stimulation is sensitive to the gait phase it is applied. These results confirmed that timing aligned with push-off is an attractor for electrical stimulation-induced perturbations of the medial gastrocnemius, and that the muscle response to stimulation is sensitive to timing and amplitude. Future research should investigate other muscles and timings and separate sensory vs. motor contributions to these phenomena.
Collapse
Affiliation(s)
- Jenna E. Thorp
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
| | - Peter Gabriel Adamczyk
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
| |
Collapse
|
15
|
Shideler BL, Bulea TC, Chen J, Stanley CJ, Gravunder AJ, Damiano DL. Toward a hybrid exoskeleton for crouch gait in children with cerebral palsy: neuromuscular electrical stimulation for improved knee extension. J Neuroeng Rehabil 2020; 17:121. [PMID: 32883297 PMCID: PMC7469320 DOI: 10.1186/s12984-020-00738-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 07/29/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Neuromuscular Electrical Stimulation (NMES) has been utilized for many years in cerebral palsy (CP) with limited success despite its inherent potential for improving muscle size and/or strength, inhibiting or reducing spasticity, and enhancing motor performance during functional activities such as gait. While surface NMES has been shown to successfully improve foot drop in CP and stroke, correction of more complex gait abnormalities in CP such as flexed knee (crouch) gait remains challenging due to the level of stimulation needed for the quadriceps muscles that must be balanced with patient tolerability and the ability to deliver NMES assistance at precise times within a gait cycle. METHODS This paper outlines the design and evaluation of a custom, noninvasive NMES system that can trigger and adjust electrical stimulation in real-time. Further, this study demonstrates feasibility of one possible application for this digitally-controlled NMES system as a component of a pediatric robotic exoskeleton to provide on-demand stimulation to leg muscles within specific phases of the gait cycle for those with CP and other neurological disorders who still have lower limb sensation and volitional control. A graphical user interface was developed to digitally set stimulation parameters (amplitude, pulse width, and frequency), timing, and intensity during walking. Benchtop testing characterized system delay and power output. System performance was investigated during a single session that consisted of four overground walking conditions in a 15-year-old male with bilateral spastic CP, GMFCS Level III: (1) his current Ankle-Foot Orthosis (AFO); (2) unassisted Exoskeleton; (3) NMES of the vastus lateralis; and (4) NMES of the vastus lateralis and rectus femoris. We hypothesized in this participant with crouch gait that NMES triggered with low latency to knee extensor muscles during stance would have a modest but positive effect on knee extension during stance. RESULTS The system delivers four channels of NMES with average delays of 16.5 ± 13.5 ms. Walking results show NMES to the vastus lateralis and rectus femoris during stance immediately improved mean peak knee extension during mid-stance (p = 0.003*) and total knee excursion (p = 0.009*) in the more affected leg. The electrical design, microcontroller software and graphical user interface developed here are included as open source material to facilitate additional research into digitally-controlled surface stimulation ( github.com/NIHFAB/NMES ). CONCLUSIONS The custom, digitally-controlled NMES system can reliably trigger electrical stimulation with low latency. Precisely timed delivery of electrical stimulation to the quadriceps is a promising treatment for crouch. Our ultimate goal is to synchronize NMES with robotic knee extension assistance to create a hybrid NMES-exoskeleton device for gait rehabilitation in children with flexed knee gait from CP as well as from other pediatric disorders. TRIAL REGISTRATION clinicaltrials.gov, ID: NCT01961557 . Registered 11 October 2013; Last Updated 27 January 2020.
Collapse
Affiliation(s)
- Blynn L Shideler
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Thomas C Bulea
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Ji Chen
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Christopher J Stanley
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Andrew J Gravunder
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Diane L Damiano
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA.
| |
Collapse
|
16
|
A review of methods for achieving upper limb movement following spinal cord injury through hybrid muscle stimulation and robotic assistance. Exp Neurol 2020; 328:113274. [DOI: 10.1016/j.expneurol.2020.113274] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 02/26/2020] [Accepted: 03/02/2020] [Indexed: 11/20/2022]
|
17
|
Shapkova EY, Pismennaya EV, Emelyannikov DV, Ivanenko Y. Exoskeleton Walk Training in Paralyzed Individuals Benefits From Transcutaneous Lumbar Cord Tonic Electrical Stimulation. Front Neurosci 2020; 14:416. [PMID: 32528238 PMCID: PMC7263322 DOI: 10.3389/fnins.2020.00416] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Accepted: 04/06/2020] [Indexed: 12/12/2022] Open
Abstract
In recent years, advanced technologies featuring wearable powered exoskeletons and neuromodulation of lumbosacral spinal networks have been developed to facilitate stepping and promote motor recovery in humans with paralysis. Here we studied a combined effect of spinal cord electrical stimulation (SCES) and exoskeleton walk training (EWT) during an intensive 2-week rehabilitative protocol in spinal cord injury individuals (n = 19, American Spinal Injury Association Impairment Scale (AIS) A-11, B-5, C-3). The purpose of this study was to evaluate the compatibility of methods and to explore the main effects of combined SCES and EWT. All participants had a chronic state of paralysis (1–11 years after trauma). In addition, in the control group (n = 16, AIS A-7, B-5, C-4), we performed EWT without SCES. For EWT, we used a powered exoskeleton (ExoAtlet), while stability was assisted by crutches, with automatic arrest of stepping if excessive torques were detected. SCES was applied to the level of the mid-lumbar cord over the Th12 vertebra at 1 or 3 pulses/s (4 individuals with severe spasticity were also stimulated in an anti-spastic mode 67 pulses/s). The vertical component of the ground reaction force was recorded using the F-Scan system at the onset and after training with SCES. EWT with SCES significantly increased the foot loading forces, could decrease their asymmetry and 8 out of 19 subjects improved their Hauser Ambulation Index. The anti-spastic mode of stimulation also allowed individuals with severe spasticity to walk with the aid of the exoskeleton. Participants reported facilitation when walking with SCES, paresthesia in leg muscles and new non-differential sensation of passive motion in leg joints. Neurological examination showed an increase of tactile (7) and/or pain (7) sensation and an increase of the AIS motor scale in 9 individuals, including both incomplete and complete paralysis. Improvements in the neurological scores were, however, limited in the control group (EWT without SCES). The results suggest that SCES may facilitate training and walking in the exoskeleton by activating the locomotor networks and augmenting compensative sensitivity.
Collapse
Affiliation(s)
- Elena Y Shapkova
- The Spinal Center of Saint-Petersburg State Research Institute of Phthisiopulmonology, Saint Petersburg, Russia.,Institute of Translational Biomedicine, Saint Petersburg State University, Saint Petersburg, Russia
| | - Elena V Pismennaya
- Institute of Mechanics, Lomonosov Moscow State University, Moscow, Russia
| | - Dmitriy V Emelyannikov
- The Spinal Center of Saint-Petersburg State Research Institute of Phthisiopulmonology, Saint Petersburg, Russia
| | | |
Collapse
|
18
|
Gil-Agudo A, Del Ama-Espinosa AJ, Lozano-Berrio V, Fernández-López A, Megía García-Carpintero A, Benito-Penalva J, Pons JL. [Robot therapy with the H2 exoskeleton for gait rehabilitation in patients with incomplete spinal cord injry. A clinical experience]. Rehabilitacion (Madr) 2020; 54:87-95. [PMID: 32370833 DOI: 10.1016/j.rh.2019.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 10/22/2019] [Indexed: 11/17/2022]
Abstract
BACKGROUND AND OBJECTIVE Robotic exoskeletons have emerged as a promising tool in gait rehabilitation in patients with a spinal cord injury. The aim of this study was to assess the clinical applicability of a new robotic exoskeleton model (Exo H2) in the rehabilitation of people with incomplete spinal cord injury. MATERIAL AND METHODS Exo H2 exoskeleton training was performed for 15 sessions in patients with incomplete subacute spinal cord injury. We analysed the appearance of undesirable events and the patient's perception of pain, fatigue and comfort. In addition, a pilot test was carried out on the possible effectiveness of the device by analysing gait characteristics before and after treatment measured by the 10mWT, the 6mWT, the TUG, the WISCI-II, and the impact on the SCIM III scale. RESULTS Of a group of 8 patients recruited, we were able to analyse data from 4. No undesirable effects were reported. The VAS value was 2.28±1.55 for pain, 3.75±1.55 for fatigue and 4.17±1.68 for comfort. All values improved on the WISCI-I and the TUG and almost all in the 10MWT and in the 6MWT. CONCLUSIONS The performance of the Exo H2 exoskeleton was robust during a clinical protocol for gait rehabilitation. The treatment was safe, without undesirable effects and with good patient tolerance. These results might justify the performance of clinical trials with an adequate sample size.
Collapse
Affiliation(s)
- A Gil-Agudo
- Servicio de Rehabilitación, Hospital Nacional de Parapléjicos de Toledo, Toledo, España; Unidad de Neurorrehabilitación, Biomecánica y Función Sensitivo-Motora (HNP-SESCAM, Unidad asociada al CSIC).
| | - A J Del Ama-Espinosa
- Unidad de Biomecánica, Hospital Nacional de Parapléjicos de Toledo, Toledo, España; Área de Tecnología Electrónica, Universidad Rey Juan Carlos, Madrid, España
| | - V Lozano-Berrio
- Unidad de Biomecánica, Hospital Nacional de Parapléjicos de Toledo, Toledo, España
| | - A Fernández-López
- Servicio de Rehabilitación, Hospital Universitario Fundación Jiménez Díaz, Madrid, España
| | | | | | - J L Pons
- Grupo de Neuro-Rehabilitación, Instituto Cajal, CSIC, Madrid, España
| |
Collapse
|
19
|
Nohama P, Nunes Nogueira Neto G, Ranciaro M. Hybrid Neuroprosthesis for Lower Limbs. PROSTHESIS 2020. [DOI: 10.5772/intechopen.83793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
20
|
Bao X, Kirsch N, Dodson A, Sharma N. Model Predictive Control of a Feedback-Linearized Hybrid Neuroprosthetic System With a Barrier Penalty. JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS 2019; 14:101009-1010097. [PMID: 32280315 PMCID: PMC7104748 DOI: 10.1115/1.4042903] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Revised: 02/06/2019] [Indexed: 06/11/2023]
Abstract
Functional electrical stimulation (FES) is prescribed as a treatment to restore motor function in individuals with neurological impairments. However, the rapid onset of FES-induced muscle fatigue significantly limits its duration of use and limb movement quality. In this paper, an electric motor-assist is proposed to alleviate the fatigue effects by sharing work load with FES. A model predictive control (MPC) method is used to allocate control inputs to FES and the electric motor. To reduce the computational load, the dynamics is feedback linearized so that the nominal model inside the MPC method becomes linear. The state variables: the angular position and the muscle fatigue are still preserved in the transformed state space to keep the optimization meaningful. Because after feedback linearization the original linear input constraints may become nonlinear and state-dependent, a barrier cost function is used to overcome this issue. The simulation results show a satisfactory control performance and a reduction in the computation due to the linearization.
Collapse
Affiliation(s)
- Xuefeng Bao
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA 15261
| | | | - Albert Dodson
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA 15261
| | - Nitin Sharma
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA 15261; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261
| |
Collapse
|
21
|
Imatz-Ojanguren E, Sánchez-Márquez G, Asiain-Aristu JR, Cueto-Mendo J, Jaunarena-Goicoechea E, Zabaleta H, Keller T. A foot drop compensation device based on surface multi-field functional electrical stimulation-Usability study in a clinical environment. J Rehabil Assist Technol Eng 2019; 6:2055668319862141. [PMID: 31516730 PMCID: PMC6724492 DOI: 10.1177/2055668319862141] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Accepted: 05/31/2019] [Indexed: 12/02/2022] Open
Abstract
Introduction Functional electrical stimulation applies electrical pulses to the peripheral nerves to artificially achieve a sensory/motor function. When applied for the compensation of foot drop it provides both assistive and therapeutic effects. Multi-field electrodes have shown great potential but may increase the complexity of these systems. Usability aspects should be checked to ensure their success in clinical environments. Methods We developed the Fesia Walk device, based on a surface multi-field electrode and an automatic calibration algorithm, and carried out a usability study to check the feasibility of integrating this device in therapeutic programs in clinical environments. The study included 4 therapists and 10 acquired brain injury subjects (8 stroke and 2 traumatic brain injury). Results Therapists and users were “very satisfied” with the device according to the Quebec User Evaluation of Satisfaction with Assistive Technology scale, with average scores of 4.1 and 4.2 out of 5, respectively. Therapists considered the Fesia Walk device as “excellent” according to the System Usability Scale with an average score of 85.6 out of 100. Conclusions This study showed us that it is feasible to include surface multi-field technology while keeping a device simple and intuitive for successful integration in common neurorehabilitation programs.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Thierry Keller
- TECNALIA, Health Division, Donostia-San Sebastián, Spain
| |
Collapse
|
22
|
Aguirre-Güemez AV, Pérez-Sanpablo AI, Quinzaños-Fresnedo J, Pérez-Zavala R, Barrera-Ortiz A. Walking speed is not the best outcome to evaluate the effect of robotic assisted gait training in people with motor incomplete Spinal Cord Injury: A Systematic Review with meta-analysis. J Spinal Cord Med 2019; 42:142-154. [PMID: 29065788 PMCID: PMC6419626 DOI: 10.1080/10790268.2017.1390644] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
CONTEXT While there are previous systematic reviews on the effectiveness of the use of robotic-assisted gait training (RAGT) in people with spinal cord injuries (SCI), as this is a dynamic field, new studies have been produced that are now incorporated on this systematic review (SR) with meta-analysis, updating the available evidence on this area. OBJECTIVE To synthesise the available evidence on the use of RAGT, to improve gait, strength and functioning. METHODS SR and meta-analysis following the Cochrane Handbook for Systematic Reviews of Interventions were implemented. Cochrane Injuries Group Specialized Register, PubMed, MEDLINE, EMBASE, CINAHL, ISIWeb of Science (SCIEXPANDED) databases were reviewed for the period 1990 to December 2016. Three researchers independently identified and categorized trials; 293 studies were identified, 273 eliminated; remaining 15 randomized clinical trials (RCT) and five SR. Six studies had available data for meta-analysis (222 participants). RESULTS The pooled mean demonstrated a beneficial effect of RAGT for WISCI, FIM-L and LEMS (3.01, 2.74 and 1.95 respectively), and no effect for speed. CONCLUSIONS The results show a positive effect in the use of RAGT. However, this should be taken carefully due to heterogeneity of the studies, small samples and identified limitations of some of the included trials. These results highlight the relevance of implementing a well-designed multicenter RCT powered enough to evaluate different RAGT approaches.
Collapse
Affiliation(s)
| | | | - Jimena Quinzaños-Fresnedo
- División de Rehabilitación Neurológica, Instituto Nacional de Rehabilitación, Ciudad de México, México,Correspondence to: Dr Jimena Quinzaños-Fresnedo, División de Rehabilitación Neurological, Instituto Nacional de Rehabilitación, Mailing adress: Avenida México-Xochimilco No. 289, Col. Arenal de Guadalupe, Delegación Tlalpan, CP, Mexico City 14389, Mexico. E-mail: Telephone: 59 99 10 00. Ext: 13410, 13411
| | - Ramiro Pérez-Zavala
- División de Rehabilitación Neurológica, Instituto Nacional de Rehabilitación, Ciudad de México, México
| | - Aída Barrera-Ortiz
- División de Rehabilitación Neurológica, Instituto Nacional de Rehabilitación, Ciudad de México, México
| |
Collapse
|
23
|
López-Larraz E, Sarasola-Sanz A, Irastorza-Landa N, Birbaumer N, Ramos-Murguialday A. Brain-machine interfaces for rehabilitation in stroke: A review. NeuroRehabilitation 2018; 43:77-97. [PMID: 30056435 DOI: 10.3233/nre-172394] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND Motor paralysis after stroke has devastating consequences for the patients, families and caregivers. Although therapies have improved in the recent years, traditional rehabilitation still fails in patients with severe paralysis. Brain-machine interfaces (BMI) have emerged as a promising tool to guide motor rehabilitation interventions as they can be applied to patients with no residual movement. OBJECTIVE This paper reviews the efficiency of BMI technologies to facilitate neuroplasticity and motor recovery after stroke. METHODS We provide an overview of the existing rehabilitation therapies for stroke, the rationale behind the use of BMIs for motor rehabilitation, the current state of the art and the results achieved so far with BMI-based interventions, as well as the future perspectives of neural-machine interfaces. RESULTS Since the first pilot study by Buch and colleagues in 2008, several controlled clinical studies have been conducted, demonstrating the efficacy of BMIs to facilitate functional recovery in completely paralyzed stroke patients with noninvasive technologies such as the electroencephalogram (EEG). CONCLUSIONS Despite encouraging results, motor rehabilitation based on BMIs is still in a preliminary stage, and further improvements are required to boost its efficacy. Invasive and hybrid approaches are promising and might set the stage for the next generation of stroke rehabilitation therapies.
Collapse
Affiliation(s)
- E López-Larraz
- Institute of Medical Psychology and Behavioral Neurobiology, University of Tübingen, Tübingen, Germany
| | - A Sarasola-Sanz
- Institute of Medical Psychology and Behavioral Neurobiology, University of Tübingen, Tübingen, Germany.,International Max Planck Research School (IMPRS) for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany.,Neurotechnology, Tecnalia Research & Innovation, San Sebastián, Spain
| | - N Irastorza-Landa
- Institute of Medical Psychology and Behavioral Neurobiology, University of Tübingen, Tübingen, Germany.,International Max Planck Research School (IMPRS) for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany.,IKERBASQUE, Basque Foundation for Science, Bilbao, Spain
| | - N Birbaumer
- Institute of Medical Psychology and Behavioral Neurobiology, University of Tübingen, Tübingen, Germany.,Wyss Center for Bio and Neuro Engineering, Geneva, Switzerland
| | - A Ramos-Murguialday
- Institute of Medical Psychology and Behavioral Neurobiology, University of Tübingen, Tübingen, Germany.,Neurotechnology, Tecnalia Research & Innovation, San Sebastián, Spain
| |
Collapse
|
24
|
Nguyen PH, Sparks C, Nuthi SG, Vale NM, Polygerinos P. Soft Poly-Limbs: Toward a New Paradigm of Mobile Manipulation for Daily Living Tasks. Soft Robot 2018; 6:38-53. [PMID: 30307793 DOI: 10.1089/soro.2018.0065] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
We present the design and development of the fluid-driven, wearable, Soft Poly-Limb (SPL), from the Greek word polys, meaning many. The SPL utilizes the numerous traits of soft robotics to enable a novel approach in providing safe and compliant mobile manipulation assistance to healthy and impaired users. This wearable system equips the user with a controllable additional limb that is capable of complex three-dimensional motion in space. Similar to an elephant trunk, the SPL is able to manipulate objects using a variety of end effectors, such as suction adhesion or a soft grasper, as well as its entire soft body to conform around an object, able to lift 2.35 times its own weight. To develop these highly articulated soft robotic limbs, we provide a novel set of systematic design rules, obtained through varying geometrical parameters of the SPL through experimentally verified finite element method models. We investigate performance of the limb by testing the lifetime of the new SPL actuators, evaluating its payload capacity, operational workspace, and capability of interacting close to a user through a spatial mobility test. Furthermore, we are able to demonstrate limb controllability through multiple user-intent detection modalities. Finally, we explore the limb's ability to assist in multitasking and pick and place scenarios with varying mounting locations of the SPL around the user's body. Our results highlight the SPL's ability to safely interact with the user while demonstrating promising performance in assisting with a wide variety of tasks, in both work and general living settings.
Collapse
Affiliation(s)
- Pham Huy Nguyen
- 1 The Polytechnic School, Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, Arizona
| | - Curtis Sparks
- 1 The Polytechnic School, Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, Arizona
| | - Sai G Nuthi
- 2 The School for Engineering of Matter, Transport and Energy, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, Arizona
| | - Nicholas M Vale
- 3 The School of Biological Health Systems Engineering, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, Arizona
| | - Panagiotis Polygerinos
- 1 The Polytechnic School, Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, Arizona
| |
Collapse
|
25
|
Gorgey AS. Robotic exoskeletons: The current pros and cons. World J Orthop 2018; 9:112-119. [PMID: 30254967 PMCID: PMC6153133 DOI: 10.5312/wjo.v9.i9.112] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Revised: 07/02/2018] [Accepted: 07/10/2018] [Indexed: 02/06/2023] Open
Abstract
Robotic exoskeletons have emerged as rehabilitation tool that may ameliorate several of the existing health-related consequences after spinal cord injury (SCI). However, evidence to support its clinical application is still lacking considering their prohibitive cost. The current mini-review is written to highlight the main limitations and potential benefits of using exoskeletons in the rehabilitation of persons with SCI. We have recognized two main areas relevant to the design of exoskeletons and to their applications on major health consequences after SCI. The design prospective refers to safety concerns, fitting time and speed of exoskeletons. The health prospective refers to factors similar to body weight, physical activity, pressure injuries and bone health. Clinical trials are currently underway to address some of these limitations and to maximize the benefits in rehabilitation settings. Future directions highlight the need to use exoskeletons in conjunction with other existing and emerging technologies similar to functional electrical stimulation and brain-computer interface to address major limitations. Exoskeletons have the potential to revolutionize rehabilitation following SCI; however, it is still premature to make solid recommendations about their clinical use after SCI.
Collapse
Affiliation(s)
- Ashraf S Gorgey
- Spinal Cord Injury and Disorders Center, Hunter Holmes McGuire VAMC, Richmond, VA 23249, United States
- Department of Physical Medicine and Rehabilitation, Virginia Commonwealth University, Richmond, VA 23249, United States
| |
Collapse
|
26
|
Sridar S, Qiao Z, Muthukrishnan N, Zhang W, Polygerinos P. A Soft-Inflatable Exosuit for Knee Rehabilitation: Assisting Swing Phase During Walking. Front Robot AI 2018; 5:44. [PMID: 33500930 PMCID: PMC7805964 DOI: 10.3389/frobt.2018.00044] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Accepted: 04/04/2018] [Indexed: 11/13/2022] Open
Abstract
In this paper, we present a soft-inflatable exosuit to assist knee extension during gait training for stroke rehabilitation. The soft exosuit is designed to provide 25% of the knee moment required during the swing phase of the gait cycle and is integrated with inertial measurement units (IMUs) and smart shoe insole sensors to improve gait phase detection and controller design. The stiffness of the knee joint during level walking is computed using inverse dynamics. The soft-inflatable actuators, with an I cross-section, are mechanically characterized at varying angles to enable generation of the required stiffness outputs. A linear relation between the inflatable actuator stiffness and internal pressure as a function of the knee angle is obtained, and a two-layer stiffness controller is implemented to assist the knee joint by providing appropriate stiffness during the swing phase. Finally, to evaluate the ability of the exosuit to assist in swing motion, surface-electromyography (sEMG) sensors are placed on the three muscle groups of the quadriceps and two groups of the hamstrings, on three healthy participants. A reduction in muscle activity of the rectus femoris, vastus lateralis, and vastus medialis is observed, which demonstrates feasibility of operation and potential future usage of the soft inflatable exosuit by impaired users.
Collapse
Affiliation(s)
- Saivimal Sridar
- The Polytechnic School, Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, AZ, United States
| | - Zhi Qiao
- School for Engineering of Matter Transport and Energy, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, AZ, United States
| | - Niveditha Muthukrishnan
- School of Biological and Health Systems Engineering, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, AZ, United States
| | - Wenlong Zhang
- The Polytechnic School, Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, AZ, United States
| | - Panagiotis Polygerinos
- The Polytechnic School, Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, AZ, United States
| |
Collapse
|
27
|
Alibeji NA, Molazadeh V, Dicianno BE, Sharma N. A Control Scheme That Uses Dynamic Postural Synergies to Coordinate a Hybrid Walking Neuroprosthesis: Theory and Experiments. Front Neurosci 2018; 12:159. [PMID: 29692699 PMCID: PMC5902565 DOI: 10.3389/fnins.2018.00159] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Accepted: 02/27/2018] [Indexed: 11/13/2022] Open
Abstract
A hybrid walking neuroprosthesis that combines functional electrical stimulation (FES) with a powered lower limb exoskeleton can be used to restore walking in persons with paraplegia. It provides therapeutic benefits of FES and torque reliability of the powered exoskeleton. Moreover, by harnessing metabolic power of muscles via FES, the hybrid combination has a potential to lower power consumption and reduce actuator size in the powered exoskeleton. Its control design, however, must overcome the challenges of actuator redundancy due to the combined use of FES and electric motor. Further, dynamic disturbances such as electromechanical delay (EMD) and muscle fatigue must be considered during the control design process. This ensures stability and control performance despite disparate dynamics of FES and electric motor. In this paper, a general framework to coordinate FES of multiple gait-governing muscles with electric motors is presented. A muscle synergy-inspired control framework is used to derive the controller and is motivated mainly to address the actuator redundancy issue. Dynamic postural synergies between FES of the muscles and the electric motors were artificially generated through optimizations and result in key dynamic postures when activated. These synergies were used in the feedforward path of the control system. A dynamic surface control technique, modified with a delay compensation term, is used as the feedback controller to address model uncertainty, the cascaded muscle activation dynamics, and EMD. To address muscle fatigue, the stimulation levels in the feedforward path were gradually increased based on a model-based fatigue estimate. A Lyapunov-based stability approach was used to derive the controller and guarantee its stability. The synergy-based controller was demonstrated experimentally on an able-bodied subject and person with an incomplete spinal cord injury.
Collapse
Affiliation(s)
- Naji A. Alibeji
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Vahidreza Molazadeh
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, United States
| | - Brad E. Dicianno
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, United States
| | - Nitin Sharma
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, United States
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| |
Collapse
|
28
|
Functional Electrical Stimulation and Its Use During Cycling for the Rehabilitation of Individuals with Stroke. ACTA ACUST UNITED AC 2018. [DOI: 10.1007/978-3-319-72736-3_21] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
29
|
Úbeda A, Azorín JM, Farina D, Sartori M. Estimation of Neuromuscular Primitives from EEG Slow Cortical Potentials in Incomplete Spinal Cord Injury Individuals for a New Class of Brain-Machine Interfaces. Front Comput Neurosci 2018; 12:3. [PMID: 29422842 PMCID: PMC5788900 DOI: 10.3389/fncom.2018.00003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Accepted: 01/04/2018] [Indexed: 11/13/2022] Open
Abstract
One of the current challenges in human motor rehabilitation is the robust application of Brain-Machine Interfaces to assistive technologies such as powered lower limb exoskeletons. Reliable decoding of motor intentions and accurate timing of the robotic device actuation is fundamental to optimally enhance the patient's functional improvement. Several studies show that it may be possible to extract motor intentions from electroencephalographic (EEG) signals. These findings, although notable, suggests that current techniques are still far from being systematically applied to an accurate real-time control of rehabilitation or assistive devices. Here we propose the estimation of spinal primitives of multi-muscle control from EEG, using electromyography (EMG) dimensionality reduction as a solution to increase the robustness of the method. We successfully apply this methodology, both to healthy and incomplete spinal cord injury (SCI) patients, to identify muscle contraction during periodical knee extension from the EEG. We then introduce a novel performance metric, which accurately evaluates muscle primitive activations.
Collapse
Affiliation(s)
- Andrés Úbeda
- AUROVA Group, Department of Physics, Systems Engineering and Signal Theory, University of Alicante, San Vicente del Raspeig, Spain.,Brain-Machine Interface Systems Lab, Miguel Hernández University, Elche, Spain
| | - José M Azorín
- Brain-Machine Interface Systems Lab, Miguel Hernández University, Elche, Spain
| | - Dario Farina
- Chair in Neurorehabilitation Engineering, Department of Bioengineering, Imperial College, London, United Kingdom
| | - Massimo Sartori
- Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| |
Collapse
|
30
|
Hybrid FES–robotic gait rehabilitation technologies: a review on mechanical design, actuation, and control strategies. INTERNATIONAL JOURNAL OF INTELLIGENT ROBOTICS AND APPLICATIONS 2018. [DOI: 10.1007/s41315-017-0042-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
31
|
Zhang D, Ren Y, Gui K, Jia J, Xu W. Cooperative Control for A Hybrid Rehabilitation System Combining Functional Electrical Stimulation and Robotic Exoskeleton. Front Neurosci 2018; 11:725. [PMID: 29311798 PMCID: PMC5742598 DOI: 10.3389/fnins.2017.00725] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Accepted: 12/12/2017] [Indexed: 11/13/2022] Open
Abstract
Functional electrical stimulation (FES) and robotic exoskeletons are two important technologies widely used for physical rehabilitation of paraplegic patients. We developed a hybrid rehabilitation system (FEXO Knee) that combined FES and an exoskeleton for swinging movement control of human knee joints. This study proposed a novel cooperative control strategy, which could realize arbitrary distribution of torque generated by FES and exoskeleton, and guarantee harmonic movements. The cooperative control adopted feedfoward control for FES and feedback control for exoskeleton. A parameter regulator was designed to update key parameters in real time to coordinate FES controller and exoskeleton controller. Two muscle groups (quadriceps and hamstrings) were stimulated to generate active torque for knee joint in synchronization with torque compensation from exoskeleton. The knee joint angle and the interactive torque between exoskeleton and shank were used as feedback signals for the control system. Central pattern generator (CPG) was adopted that acted as a phase predictor to deal with phase confliction of motor patterns, and realized synchronization between the two different bodies (shank and exoskeleton). Experimental evaluation of the hybrid FES-exoskeleton system was conducted on five healthy subjects and four paraplegic patients. Experimental results and statistical analysis showed good control performance of the cooperative control on torque distribution, trajectory tracking, and phase synchronization.
Collapse
Affiliation(s)
- Dingguo Zhang
- State Key Laboratory of Mechanical Systems and Vibrations, Robotics Institute, Shanghai Jiao Tong University, Shanghai, China
| | - Yong Ren
- State Key Laboratory of Mechanical Systems and Vibrations, Robotics Institute, Shanghai Jiao Tong University, Shanghai, China
| | - Kai Gui
- State Key Laboratory of Mechanical Systems and Vibrations, Robotics Institute, Shanghai Jiao Tong University, Shanghai, China
| | - Jie Jia
- Huashan Hospital, School of Medicine, Fudan University, Shanghai, China
| | - Wendong Xu
- Huashan Hospital, School of Medicine, Fudan University, Shanghai, China
| |
Collapse
|
32
|
|
33
|
Lacquaniti F, Ivanenko YP, Sylos-Labini F, La Scaleia V, La Scaleia B, Willems PA, Zago M. Human Locomotion in Hypogravity: From Basic Research to Clinical Applications. Front Physiol 2017; 8:893. [PMID: 29163225 PMCID: PMC5682019 DOI: 10.3389/fphys.2017.00893] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 10/24/2017] [Indexed: 01/07/2023] Open
Abstract
We have considerable knowledge about the mechanisms underlying compensation of Earth gravity during locomotion, a knowledge obtained from physiological, biomechanical, modeling, developmental, comparative, and paleoanthropological studies. By contrast, we know much less about locomotion and movement in general under sustained hypogravity. This lack of information poses a serious problem for human space exploration. In a near future humans will walk again on the Moon and for the first time on Mars. It would be important to predict how they will move around, since we know that locomotion and mobility in general may be jeopardized in hypogravity, especially when landing after a prolonged weightlessness of the space flight. The combination of muscle weakness, of wearing a cumbersome spacesuit, and of maladaptive patterns of locomotion in hypogravity significantly increase the risk of falls and injuries. Much of what we currently know about locomotion in hypogravity derives from the video archives of the Apollo missions on the Moon, the experiments performed with parabolic flight or with body weight support on Earth, and the theoretical models. These are the topics of our review, along with the issue of the application of simulated hypogravity in rehabilitation to help patients with deambulation problems. We consider several issues that are common to the field of space science and clinical rehabilitation: the general principles governing locomotion in hypogravity, the methods used to reduce gravity effects on locomotion, the extent to which the resulting behavior is comparable across different methods, the important non-linearities of several locomotor parameters as a function of the gravity reduction, the need to use multiple methods to obtain reliable results, and the need to tailor the methods individually based on the physiology and medical history of each person.
Collapse
Affiliation(s)
- Francesco Lacquaniti
- Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
- Center of Space BioMedicine, University of Rome Tor Vergata, Rome, Italy
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, Rome, Italy
| | - Yury P. Ivanenko
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, Rome, Italy
| | - Francesca Sylos-Labini
- Center of Space BioMedicine, University of Rome Tor Vergata, Rome, Italy
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, Rome, Italy
| | - Valentina La Scaleia
- Center of Space BioMedicine, University of Rome Tor Vergata, Rome, Italy
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, Rome, Italy
| | - Barbara La Scaleia
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, Rome, Italy
| | - Patrick A. Willems
- Laboratory of Biomechanics and Physiology of Locomotion, Institute of NeuroScience, Université catholique de Louvain, Louvain-la-Neuve, Belgium
| | - Myrka Zago
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, Rome, Italy
| |
Collapse
|
34
|
Gad P, Gerasimenko Y, Zdunowski S, Turner A, Sayenko D, Lu DC, Edgerton VR. Weight Bearing Over-ground Stepping in an Exoskeleton with Non-invasive Spinal Cord Neuromodulation after Motor Complete Paraplegia. Front Neurosci 2017. [PMID: 28642680 PMCID: PMC5462970 DOI: 10.3389/fnins.2017.00333] [Citation(s) in RCA: 104] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
We asked whether coordinated voluntary movement of the lower limbs could be regained in an individual having been completely paralyzed (>4 year) and completely absent of vision (>15 year) using two novel strategies-transcutaneous electrical spinal cord stimulation at selected sites over the spine as well as pharmacological neuromodulation by buspirone. We also asked whether these neuromodulatory strategies could facilitate stepping assisted by an exoskeleton (EKSO, EKSO Bionics, CA) that is designed so that the subject can voluntarily complement the work being performed by the exoskeleton. We found that spinal cord stimulation and drug enhanced the level of effort that the subject could generate while stepping in the exoskeleton. In addition, stimulation improved the coordination patterns of the lower limb muscles resulting in a more continuous, smooth stepping motion in the exoskeleton along with changes in autonomic functions including cardiovascular and thermoregulation. Based on these data from this case study it appears that there is considerable potential for positive synergistic effects after complete paralysis by combining the over-ground step training in an exoskeleton, combined with transcutaneous electrical spinal cord stimulation either without or with pharmacological modulation.
Collapse
Affiliation(s)
- Parag Gad
- Department of Integrative Biology and Physiology, University of California, Los AngelesLos Angeles, CA, United States
| | - Yury Gerasimenko
- Department of Integrative Biology and Physiology, University of California, Los AngelesLos Angeles, CA, United States.,Pavlov Institute of PhysiologySt. Petersburg, Russia
| | - Sharon Zdunowski
- Department of Integrative Biology and Physiology, University of California, Los AngelesLos Angeles, CA, United States
| | - Amanda Turner
- Department of Integrative Biology and Physiology, University of California, Los AngelesLos Angeles, CA, United States
| | - Dimitry Sayenko
- Department of Integrative Biology and Physiology, University of California, Los AngelesLos Angeles, CA, United States
| | - Daniel C Lu
- Department of Neurosurgery, University of California, Los AngelesLos Angeles, CA, United States.,Brain Research Institute, University of California, Los AngelesLos Angeles, CA, United States
| | - V Reggie Edgerton
- Department of Integrative Biology and Physiology, University of California, Los AngelesLos Angeles, CA, United States.,Department of Neurosurgery, University of California, Los AngelesLos Angeles, CA, United States.,Brain Research Institute, University of California, Los AngelesLos Angeles, CA, United States.,Department of Neurobiology, University of California, Los AngelesLos Angeles, CA, United States.,Institut Guttmann, Hospital de Neurorehabilitació, Institut Universitari adscrit a la Universitat Autònoma de BarcelonaBarcelona, Spain
| |
Collapse
|
35
|
Resquín F, Cuesta Gómez A, Gonzalez-Vargas J, Brunetti F, Torricelli D, Molina Rueda F, Cano de la Cuerda R, Miangolarra JC, Pons JL. Hybrid robotic systems for upper limb rehabilitation after stroke: A review. Med Eng Phys 2016; 38:1279-1288. [PMID: 27692878 DOI: 10.1016/j.medengphy.2016.09.001] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Revised: 06/11/2016] [Accepted: 09/14/2016] [Indexed: 12/27/2022]
Abstract
In recent years the combined use of functional electrical stimulation (FES) and robotic devices, called hybrid robotic rehabilitation systems, has emerged as a promising approach for rehabilitation of lower and upper limb motor functions. This paper presents a review of the state of the art of current hybrid robotic solutions for upper limb rehabilitation after stroke. For this aim, studies have been selected through a search using web databases: IEEE-Xplore, Scopus and PubMed. A total of 10 different hybrid robotic systems were identified, and they are presented in this paper. Selected systems are critically compared considering their technological components and aspects that form part of the hybrid robotic solution, the proposed control strategies that have been implemented, as well as the current technological challenges in this topic. Additionally, we will present and discuss the corresponding evidences on the effectiveness of these hybrid robotic therapies. The review also discusses the future trends in this field.
Collapse
Affiliation(s)
- Francisco Resquín
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain.
| | - Alicia Cuesta Gómez
- Motion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Faculty of Health Sciences, Rey Juan Carlos University, Madrid, Spain
| | - Jose Gonzalez-Vargas
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain
| | - Fernando Brunetti
- Universidad Católica "Nuestra Señora de la Asunción", Department of Electronic and Informatic Engineering, Asunción, Paraguay
| | - Diego Torricelli
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain
| | - Francisco Molina Rueda
- Motion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Faculty of Health Sciences, Rey Juan Carlos University, Madrid, Spain
| | - Roberto Cano de la Cuerda
- Motion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Faculty of Health Sciences, Rey Juan Carlos University, Madrid, Spain
| | - Juan Carlos Miangolarra
- Motion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Faculty of Health Sciences, Rey Juan Carlos University, Madrid, Spain
| | - José Luis Pons
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain
| |
Collapse
|
36
|
Federici S, Meloni F, Bracalenti M, De Filippis ML. The effectiveness of powered, active lower limb exoskeletons in neurorehabilitation: A systematic review. NeuroRehabilitation 2016; 37:321-40. [PMID: 26529583 DOI: 10.3233/nre-151265] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE This review examines the utility of current active, powered, wearable lower limb exoskeletons as aids to rehabilitation in paraplegic patients with gait disorders resulting from central nervous system lesions. METHODS The PRISMA guidelines were used to review literature on the use of powered and active lower limb exoskeletons for neurorehabilitative training in paraplegic subjects retrieved in a search of the electronic databases PubMed, EBSCO, Web of Science, Scopus, ProQuest, and Google Scholar. RESULTS We reviewed 27 studies published between 2001 and 2014, involving a total of 144 participants from the USA, Japan, Germany, Sweden, Israel, Italy, and Spain. Seventy percent of the studies were experimental tests of safety or efficacy and 29% evaluated rehabilitative effectiveness through uncontrolled (22%) or controlled (7%) clinical trials. CONCLUSIONS Exoskeletons provide a safe and practical method of neurorehabilitation which is not physically exhausting and makes minimal demands on working memory. It is easy to learn to use an exoskeleton and they increase mobility, improve functioning and reduce the risk of secondary injury by reinstating a more normal gait pattern. A limitation of the field is the lack of experimental methods for demonstrating the relative effectiveness of the exoskeleton in comparison with other rehabilitative techniques and technologies.
Collapse
Affiliation(s)
- Stefano Federici
- Department of Philosophy, Social & Human Sciences and Education, University of Perugia, Italy
| | - Fabio Meloni
- Department of Philosophy, Social & Human Sciences and Education, University of Perugia, Italy
| | - Marco Bracalenti
- Department of Philosophy, Social & Human Sciences and Education, University of Perugia, Italy
| | - Maria Laura De Filippis
- NIHR MindTech Healthcare Technology Co-operative, Institute of Mental Health, Jubilee Campus, Nottingham, UK
| |
Collapse
|
37
|
Resquín F, Gonzalez-Vargas J, Ibáñez J, Brunetti F, Pons JL. Feedback Error Learning Controller for Functional Electrical Stimulation Assistance in a Hybrid Robotic System for Reaching Rehabilitation. Eur J Transl Myol 2016; 26:6164. [PMID: 27990245 PMCID: PMC5128978 DOI: 10.4081/ejtm.2016.6164] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Hybrid robotic systems represent a novel research field, where functional electrical stimulation (FES) is combined with a robotic device for rehabilitation of motor impairment. Under this approach, the design of robust FES controllers still remains an open challenge. In this work, we aimed at developing a learning FES controller to assist in the performance of reaching movements in a simple hybrid robotic system setting. We implemented a Feedback Error Learning (FEL) control strategy consisting of a feedback PID controller and a feedforward controller based on a neural network. A passive exoskeleton complemented the FES controller by compensating the effects of gravity. We carried out experiments with healthy subjects to validate the performance of the system. Results show that the FEL control strategy is able to adjust the FES intensity to track the desired trajectory accurately without the need of a previous mathematical model.
Collapse
Affiliation(s)
- Francisco Resquín
- Neural Rehabilitation Group, Cajal Institute , Spanish National Research Council (CSIC), Madrid, Spain
| | - Jose Gonzalez-Vargas
- Neural Rehabilitation Group, Cajal Institute , Spanish National Research Council (CSIC), Madrid, Spain
| | - Jaime Ibáñez
- Neural Rehabilitation Group, Cajal Institute , Spanish National Research Council (CSIC), Madrid, Spain
| | | | - José Luis Pons
- Neural Rehabilitation Group, Cajal Institute , Spanish National Research Council (CSIC), Madrid, Spain
| |
Collapse
|
38
|
Ao D, Song R, Gao J. Movement Performance of Human-Robot Cooperation Control Based on EMG-Driven Hill-Type and Proportional Models for an Ankle Power-Assist Exoskeleton Robot. IEEE Trans Neural Syst Rehabil Eng 2016; 25:1125-1134. [PMID: 27337719 DOI: 10.1109/tnsre.2016.2583464] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Although the merits of electromyography (EMG)-based control of powered assistive systems have been certified, the factors that affect the performance of EMG-based human-robot cooperation, which are very important, have received little attention. This study investigates whether a more physiologically appropriate model could improve the performance of human-robot cooperation control for an ankle power-assist exoskeleton robot. To achieve the goal, an EMG-driven Hill-type neuromusculoskeletal model (HNM) and a linear proportional model (LPM) were developed and calibrated through maximum isometric voluntary dorsiflexion (MIVD). The two control models could estimate the real-time ankle joint torque, and HNM is more accurate and can account for the change of the joint angle and muscle dynamics. Then, eight healthy volunteers were recruited to wear the ankle exoskeleton robot and complete a series of sinusoidal tracking tasks in the vertical plane. With the various levels of assist based on the two calibrated models, the subjects were instructed to track the target displayed on the screen as accurately as possible by performing ankle dorsiflexion and plantarflexion. Two measurements, the root mean square error (RMSE) and root mean square jerk (RMSJ), were derived from the assistant torque and kinematic signals to characterize the movement performances, whereas the amplitudes of the recorded EMG signals from the tibialis anterior (TA) and the gastrocnemius (GAS) were obtained to reflect the muscular efforts. The results demonstrated that the muscular effort and smoothness of tracking movements decreased with an increase in the assistant ratio. Compared with LPM, subjects made lower physical efforts and generated smoother movements when using HNM, which implied that a more physiologically appropriate model could enable more natural and human-like human-robot cooperation and has potential value for improvement of human-exoskeleton interaction in future applications.
Collapse
|
39
|
Riener R. The Cybathlon promotes the development of assistive technology for people with physical disabilities. J Neuroeng Rehabil 2016; 13:49. [PMID: 27246601 PMCID: PMC4886429 DOI: 10.1186/s12984-016-0157-2] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Accepted: 05/23/2016] [Indexed: 12/21/2022] Open
Abstract
Background The Cybathlon is a new kind of championship, where people with physical disabilities compete against each other at tasks of daily life, with the aid of advanced assistive devices including robotic technologies. The first championship will take place at the Swiss Arena Kloten, Zurich, on 8 October 2016. The idea Six disciplines are part of the competition comprising races with powered leg prostheses, powered arm prostheses, functional electrical stimulation driven bikes, powered wheelchairs, powered exoskeletons and brain-computer interfaces. This commentary describes the six disciplines and explains the current technological deficiencies that have to be addressed by the competing teams. These deficiencies at present often lead to disappointment or even rejection of some of the related technologies in daily applications. Conclusion The Cybathlon aims to promote the development of useful technologies that facilitate the lives of people with disabilities. In the long run, the developed devices should become affordable and functional for all relevant activities in daily life.
Collapse
Affiliation(s)
- Robert Riener
- Sensory-Motor Systems Lab, ETH Zurich, Tannenstrasse 1, 8092, Zurich, Switzerland. .,Spinal Cord Injury Center, University Hospital Bagrist, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
40
|
Ha KH, Murray SA, Goldfarb M. An Approach for the Cooperative Control of FES With a Powered Exoskeleton During Level Walking for Persons With Paraplegia. IEEE Trans Neural Syst Rehabil Eng 2016; 24:455-66. [DOI: 10.1109/tnsre.2015.2421052] [Citation(s) in RCA: 102] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
41
|
Chang SR, Nandor MJ, Kobetic R, Foglyano KM, Quinn RD, Triolo RJ. Improving stand-to-sit maneuver for individuals with spinal cord injury. J Neuroeng Rehabil 2016; 13:27. [PMID: 26979386 PMCID: PMC4793745 DOI: 10.1186/s12984-016-0137-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 03/09/2016] [Indexed: 11/23/2022] Open
Abstract
Background Users of neuroprostheses employing electrical stimulation (ES) generally complete the stand-to-sit (STS) maneuver with high knee angular velocities, increased upper limb support forces, and high peak impact forces at initial contact with the chair. Controlling the knee during STS descent is challenging in individuals with spinal cord injury (SCI) due to the decreasing joint moment available with increased knee angle in response to ES. Methods The goal of this study was to investigate the effects of incorporating either (1) a coupling mechanism that coordinates hip and knee flexion or (2) a mechanism that damps knee motion to keep the knee angular velocity constant during the STS transition. The coupling and damping were achieved by hydraulic orthotic mechanisms. Two subjects with SCI were enrolled and each served as their own controls when characterizing the performance of each mechanism during STS as compared to stimulation alone. Outcome measures such as hip-knee angle, knee angular velocity, upper limb support force, and impact force were analyzed to determine the effectiveness of the two mechanisms in providing controlled STS. Results The coordination between the hip and knee joints improved with each orthotic mechanism. The damping and hip-knee coupling mechanisms caused the hip and knee joint ratios of 1:1.1 and 1:0.99, respectively, which approached the 1:1 coordination ratio observed in nondisabled individuals during STS maneuver. The knee damping mechanism provided lower (p < 0.001) and a more constant knee angular velocity than the hip-knee coupling mechanism over the knee range of motion. Both the coupling and damping mechanisms were similarly effective at reducing upper limb support forces by 70 % (p < 0.001) and impact force by half (p ≤ 0.001) as compared to sitting down with stimulation alone. Conclusions Orthoses imposing simple kinematic constraints, such as 1:1 hip-knee coupling or knee damping, can normalize upper limb support forces, peak knee angular velocity, and peak impact force during the STS maneuvers.
Collapse
Affiliation(s)
- Sarah R Chang
- Department of Veterans Affairs, Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, 151AW/APT, Cleveland, OH, 44106, USA. .,Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH, 44106, USA.
| | - Mark J Nandor
- Department of Veterans Affairs, Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, 151AW/APT, Cleveland, OH, 44106, USA.,Department of Mechanical Engineering and Aerospace Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH, 44106, USA
| | - Rudi Kobetic
- Department of Veterans Affairs, Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, 151AW/APT, Cleveland, OH, 44106, USA
| | - Kevin M Foglyano
- Department of Veterans Affairs, Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, 151AW/APT, Cleveland, OH, 44106, USA
| | - Roger D Quinn
- Department of Veterans Affairs, Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, 151AW/APT, Cleveland, OH, 44106, USA.,Department of Mechanical Engineering and Aerospace Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH, 44106, USA
| | - Ronald J Triolo
- Department of Veterans Affairs, Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, 151AW/APT, Cleveland, OH, 44106, USA.,Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH, 44106, USA.,Department of Orthopaedics, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH, 44106, USA
| |
Collapse
|
42
|
Qiao M, Jindrich DL. Leg joint function during walking acceleration and deceleration. J Biomech 2016; 49:66-72. [DOI: 10.1016/j.jbiomech.2015.11.022] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2014] [Revised: 09/30/2015] [Accepted: 11/15/2015] [Indexed: 10/22/2022]
|
43
|
Constantinescu C, Popescu D, Muresan PC, Stana SI. Exoskeleton-centered Process Optimization in Advanced Factory Environments. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.procir.2015.12.051] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
44
|
Hortal E, Planelles D, Resquin F, Climent JM, Azorín JM, Pons JL. Using a brain-machine interface to control a hybrid upper limb exoskeleton during rehabilitation of patients with neurological conditions. J Neuroeng Rehabil 2015; 12:92. [PMID: 26476869 PMCID: PMC4609472 DOI: 10.1186/s12984-015-0082-9] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 10/08/2015] [Indexed: 11/30/2022] Open
Abstract
Background As a consequence of the increase of cerebro-vascular accidents, the number of people suffering from motor disabilities is raising. Exoskeletons, Functional Electrical Stimulation (FES) devices and Brain-Machine Interfaces (BMIs) could be combined for rehabilitation purposes in order to improve therapy outcomes. Methods In this work, a system based on a hybrid upper limb exoskeleton is used for neurological rehabilitation. Reaching movements are supported by the passive exoskeleton ArmeoSpring and FES. The movement execution is triggered by an EEG-based BMI. The BMI uses two different methods to interact with the exoskeleton from the user’s brain activity. The first method relies on motor imagery tasks classification, whilst the second one is based on movement intention detection. Results Three healthy users and five patients with neurological conditions participated in the experiments to verify the usability of the system. Using the BMI based on motor imagery, healthy volunteers obtained an average accuracy of 82.9 ± 14.5 %, and patients obtained an accuracy of 65.3 ± 9.0 %, with a low False Positives rate (FP) (19.2 ± 10.4 % and 15.0 ± 8.4 %, respectively). On the other hand, by using the BMI based on detecting the arm movement intention, the average accuracy was 76.7 ± 13.2 % for healthy users and 71.6 ± 15.8 % for patients, with 28.7 ± 19.9 % and 21.2 ± 13.3 % of FP rate (healthy users and patients, respectively). Conclusions The accuracy of the results shows that the combined use of a hybrid upper limb exoskeleton and a BMI could be used for rehabilitation therapies. The advantage of this system is that the user is an active part of the rehabilitation procedure. The next step will be to verify what are the clinical benefits for the patients using this new rehabilitation procedure.
Collapse
Affiliation(s)
- Enrique Hortal
- Brain-Machine Interface Systems Lab, Miguel Hernández University of Elche, Av. de la Universidad, S/N, Elche, 03202, Spain.
| | - Daniel Planelles
- Brain-Machine Interface Systems Lab, Miguel Hernández University of Elche, Av. de la Universidad, S/N, Elche, 03202, Spain.
| | - Francisco Resquin
- Rehabilitation Group, Cajal Institute, Spanish National Research Council, Madrid, Spain.
| | - José M Climent
- Department of Physical Medicine and Rehabilitation, Hospital General Universitario de Alicante, Alicante, Spain.
| | - José M Azorín
- Brain-Machine Interface Systems Lab, Miguel Hernández University of Elche, Av. de la Universidad, S/N, Elche, 03202, Spain.
| | - José L Pons
- Rehabilitation Group, Cajal Institute, Spanish National Research Council, Madrid, Spain.
| |
Collapse
|
45
|
Kirsch N, Alibeji N, Fisher L, Gregory C, Sharma N. A semi-active hybrid neuroprosthesis for restoring lower limb function in paraplegics. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:2557-60. [PMID: 25570512 DOI: 10.1109/embc.2014.6944144] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Through the application of functional electrical stimulation (FES) individuals with paraplegia can regain lost walking function. However, due to the rapid onset of muscle fatigue, the walking duration obtained with an FES-based neuroprosthesis is often relatively short. The rapid muscle fatigue can be compensated for by using a hybrid system that uses both FES and an active orthosis. In this paper, we demonstrate the initial testing of a semi-active hybrid walking neuroprosthesis. The semi-active hybrid orthosis (SEAHO) supports a user during the stance phase and standing while the electric motors attached to the hip section of the orthosis are used to generate hip flexion/extension. FES in SEAHO is mainly used to actuate knee flexion/extension and plantar flexion of the foot. SEAHO is controlled by a finite state machine that uses a recently developed nonlinear controller for position tracking control of the hip motors and cues from the hip angle to actuate FES and other components.
Collapse
|
46
|
Bhuiyan MSH, Choudhury IA, Dahari M. Development of a control system for artificially rehabilitated limbs: a review. BIOLOGICAL CYBERNETICS 2015; 109:141-162. [PMID: 25491411 DOI: 10.1007/s00422-014-0635-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2013] [Accepted: 10/28/2014] [Indexed: 06/04/2023]
Abstract
Development of an advanced control system for prostheses (artificial limbs) is necessary to provide functionality, effectiveness, and preferably the feeling of a sound living limb. The development of the control system has introduced varieties of control strategies depending on the application. This paper reviews some control systems used for prosthetics, orthotics, and exoskeletons. The advantages and limitations of different control systems for particular applications have been discussed and presented in a comparative manner to help in deciding the appropriate method for pertinent application.
Collapse
Affiliation(s)
- M S H Bhuiyan
- Manufacturing System Integration, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia,
| | | | | |
Collapse
|
47
|
Thompson DM, Koppes AN, Hardy JG, Schmidt CE. Electrical stimuli in the central nervous system microenvironment. Annu Rev Biomed Eng 2015; 16:397-430. [PMID: 25014787 DOI: 10.1146/annurev-bioeng-121813-120655] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Electrical stimulation to manipulate the central nervous system (CNS) has been applied as early as the 1750s to produce visual sensations of light. Deep brain stimulation (DBS), cochlear implants, visual prosthetics, and functional electrical stimulation (FES) are being applied in the clinic to treat a wide array of neurological diseases, disorders, and injuries. This review describes the history of electrical stimulation of the CNS microenvironment; recent advances in electrical stimulation of the CNS, including DBS to treat essential tremor, Parkinson's disease, and depression; FES for the treatment of spinal cord injuries; and alternative electrical devices to restore vision and hearing via neuroprosthetics (retinal and cochlear implants). It also discusses the role of electrical cues during development and following injury and, importantly, manipulation of these endogenous cues to support regeneration of neural tissue.
Collapse
Affiliation(s)
- Deanna M Thompson
- Department of Biomedical Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York 12180;
| | | | | | | |
Collapse
|
48
|
Abstract
SUMMARYThis paper presents the design, kinematics, dynamics and control of a low-cost parallel rehabilitation robot developed at the Universitat Politècnica de Valencia. Several position and force controllers have been tested to ensure accurate tracking performances. An orthopedic boot, equipped with a force sensor, has been placed over the platform of the parallel robot to perform exercises for injured ankles. Passive, active-assistive and active-resistive exercises have been implemented to train dorsi/plantar flexion, inversion and eversion ankle movements. In order to implement the controllers, the component-based middleware Orocos has been used with the advantage over other solutions that the whole scheme control can be implemented modularly. These modules are independent and can be configured and reconfigured in both configuration and runtime. This means that no specific knowledge is needed by medical staff, for example, to carry out rehabilitation exercises using this low-cost parallel robot. The integration between Orocos and ROS, with a CAD model displaying the actual position of the rehabilitation robot in real time, makes it possible to develop a teleoperation application. In addition, a teleoperated rehabilitation exercise can be performed by a specialist using a Wiimote (or any other Bluetooth device).
Collapse
|
49
|
Pisotta I, Perruchoud D, Ionta S. Hand-in-hand advances in biomedical engineering and sensorimotor restoration. J Neurosci Methods 2015; 246:22-9. [PMID: 25769276 DOI: 10.1016/j.jneumeth.2015.03.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Revised: 02/26/2015] [Accepted: 03/03/2015] [Indexed: 01/30/2023]
Abstract
BACKGROUND Living in a multisensory world entails the continuous sensory processing of environmental information in order to enact appropriate motor routines. The interaction between our body and our brain is the crucial factor for achieving such sensorimotor integration ability. Several clinical conditions dramatically affect the constant body-brain exchange, but the latest developments in biomedical engineering provide promising solutions for overcoming this communication breakdown. NEW METHOD The ultimate technological developments succeeded in transforming neuronal electrical activity into computational input for robotic devices, giving birth to the era of the so-called brain-machine interfaces. Combining rehabilitation robotics and experimental neuroscience the rise of brain-machine interfaces into clinical protocols provided the technological solution for bypassing the neural disconnection and restore sensorimotor function. RESULTS Based on these advances, the recovery of sensorimotor functionality is progressively becoming a concrete reality. However, despite the success of several recent techniques, some open issues still need to be addressed. COMPARISON WITH EXISTING METHOD(S) Typical interventions for sensorimotor deficits include pharmaceutical treatments and manual/robotic assistance in passive movements. These procedures achieve symptoms relief but their applicability to more severe disconnection pathologies is limited (e.g. spinal cord injury or amputation). CONCLUSIONS Here we review how state-of-the-art solutions in biomedical engineering are continuously increasing expectances in sensorimotor rehabilitation, as well as the current challenges especially with regards to the translation of the signals from brain-machine interfaces into sensory feedback and the incorporation of brain-machine interfaces into daily activities.
Collapse
Affiliation(s)
- Iolanda Pisotta
- Neurological and Spinal Cord Injury Rehabilitation Department A and CaRMA Lab, IRCCS Fondazione S. Lucia, Rome, Italy
| | - David Perruchoud
- The Laboratory for Investigative Neurophysiology (The LINE), Department of Radiology and Department of Clinical Neurosciences, University Hospital Center and University of Lausanne, Lausanne, Switzerland
| | - Silvio Ionta
- The Laboratory for Investigative Neurophysiology (The LINE), Department of Radiology and Department of Clinical Neurosciences, University Hospital Center and University of Lausanne, Lausanne, Switzerland.
| |
Collapse
|
50
|
Feasibility of a Hydraulic Power Assist System for Use in Hybrid Neuroprostheses. Appl Bionics Biomech 2015; 2015:205104. [PMID: 27017963 PMCID: PMC4745429 DOI: 10.1155/2015/205104] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 02/03/2015] [Accepted: 03/01/2015] [Indexed: 11/28/2022] Open
Abstract
Feasibility of using pressurized hydraulic fluid as a source of on-demand assistive power for hybrid neuroprosthesis combining exoskeleton with functional neuromuscular stimulation was explored. Hydraulic systems were selected as an alternative to electric motors for their high torque/mass ratio and ability to be located proximally on the exoskeleton and distribute power distally to assist in moving the joints. The power assist system (PAS) was designed and constructed using off-the-shelf components to test the feasibility of using high pressure fluid from an accumulator to provide assistive torque to an exoskeletal hip joint. The PAS was able to provide 21 Nm of assistive torque at an input pressure of 3171 kPa with a response time of 93 ms resulting in 32° of hip flexion in an able-bodied test. The torque output was independent of initial position of the joint and was linearly related to pressure. Thus, accumulator pressure can be specified to provide assistive torque as needed in exoskeletal devices for walking or stair climbing beyond those possible either volitionally or with electrical stimulation alone.
Collapse
|