Paradowska-Stolarz A, Wezgowiec J, Malysa A, Wieckiewicz M. Effects of Polishing and Artificial Aging on Mechanical Properties of Dental LT Clear ® Resin. J Funct Biomater 2023; 14:295. [PMID: 37367259 DOI: 10.3390/jfb14060295] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/22/2023] [Accepted: 05/23/2023] [Indexed: 06/28/2023] Open
Abstract
Three-dimensional printing has become incorporated into various aspects of everyday life, including dentistry. Novel materials are being introduced rapidly. One such material is Dental LT Clear by Formlabs, a resin used for manufacturing occlusal splints, aligners, and orthodontic retainers. In this study, a total of 240 specimens, comprising two shapes (dumbbell and rectangular), were evaluated through compression and tensile tests. The compression tests revealed that the specimens were neither polished nor aged. However, after polishing, the compression modulus values decreased significantly. Specifically, the unpolished and nonaged specimens measured 0.87 ± 0.02, whereas the polished group measured 0.086 ± 0.03. The results were significantly affected by artificial aging. The polished group measured 0.73 ± 0.05, while the unpolished group measured 0.73 ± 0.03. In contrast, the tensile test proved that the specimens showed the highest resistance when the polishing was applied. The artificial aging influenced the tensile test and reduced the force needed to damage the specimens. The tensile modulus had the highest value when polishing was applied (3.00 ± 0.11). The conclusions drawn from these findings are as follows: 1. Polishing does not change the properties of the examined resin. 2. Artificial aging reduces resistance in both compression and tensile tests. 3. Polishing reduces the damage to the specimens in the aging process.
Collapse
Affiliation(s)
- Anna Paradowska-Stolarz
- Division of Dentofacial Anomalies, Department of Maxillofacial Orthopedics and Orthodontics, Wroclaw Medical University, 50-425 Wroclaw, Poland
| | - Joanna Wezgowiec
- Department of Experimental Dentistry, Wroclaw Medical University, 50-425 Wroclaw, Poland
| | - Andrzej Malysa
- Department of Experimental Dentistry, Wroclaw Medical University, 50-425 Wroclaw, Poland
| | - Mieszko Wieckiewicz
- Department of Experimental Dentistry, Wroclaw Medical University, 50-425 Wroclaw, Poland
| |
Collapse
|
2
|
Paradowska-Stolarz A, Mikulewicz M, Wieckiewicz M, Wezgowiec J. The Influence of Polishing and Artificial Aging on BioMed Amber ® Resin's Mechanical Properties. J Funct Biomater 2023; 14:jfb14050254. [PMID: 37233364 DOI: 10.3390/jfb14050254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 04/26/2023] [Accepted: 04/28/2023] [Indexed: 05/27/2023] Open
Abstract
Currently, 3D print is becoming more common in all branches of medicine, including dentistry. Some novel resins, such as BioMed Amber (Formlabs), are used and incorporated to more advanced techniques. The aims of the study were to check whether or not polishing and/or artificial aging influences the properties of the 3D-printed resin. A total of 240 specimens of BioMed Resin were printed. Two shapes (rectangular and dumbbell) were prepared. Of each shape, 120 specimens were divided into four groups each (with no influence, after polishing only, after artificial aging only, and after both polishing and artificial aging). Artificial aging took place in water at the temperature of 37 °C for 90 days. For testing, the universal testing machine (Z10-X700, AML Instruments, Lincoln, UK) was used. The axial compression was performed with the speed of 1mm/min. The tensile modulus was measured with the constant speed of 5 mm/min. The highest resistance to compression and tensile test were observed in the specimens that were neither polished nor aged (0.88 ± 0.03 and 2.88 ± 0.26, respectively). The lowest resistance to compression was observed in the specimens that were not polished, but aged (0.70 ± 0.02). The lowest results of the tensile test were observed when specimens were both polished and aged (2.05 ± 0.28). Both polishing and artificial aging weakened the mechanical properties of the BioMed Amber resin. The compressive modulus changed much with or without polishing. The tensile modulus differed in specimens that were either polished or aged. The application of both did not change the properties when compared to the polished or aged probes only.
Collapse
Affiliation(s)
- Anna Paradowska-Stolarz
- Division of Dentofacial Anomalies, Department of Orthodontics and Dentofacial Orthopedics, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
| | - Marcin Mikulewicz
- Division of Dentofacial Anomalies, Department of Orthodontics and Dentofacial Orthopedics, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
| | - Mieszko Wieckiewicz
- Department of Experimental Dentistry, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
| | - Joanna Wezgowiec
- Department of Experimental Dentistry, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
| |
Collapse
|
3
|
Allccahuaman-Avalos R, Medina-Sánchez R, Castro-Ramirez L, Ladera-Castañeda M, Cervantes-Ganoza L, Martínez-Campos R, Solís-Dante F, Aliaga-Mariñas A, Verástegui-Sandoval A, Cayo-Rojas C. In Vitro Color Stability Evaluation of Three Polished and Unpolished Nanohybrid Resin Composites Immersed in a 0.12% Chlorhexidine-Based Mouthwash at Different Times. Polymers (Basel) 2023; 15:polym15061339. [PMID: 36987120 PMCID: PMC10055837 DOI: 10.3390/polym15061339] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 02/26/2023] [Accepted: 03/02/2023] [Indexed: 03/12/2023] Open
Abstract
The use of chlorhexidine-based mouthwashes on resin composites with rough surfaces can cause discoloration which compromises the esthetic of patients. The present study aimed to evaluate the in vitro color stability of Forma (Ultradent Products, Inc., South Jordan), Tetric N-Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Z350XT (3M, ESPE, St. Paul, MN, USA) resin composites, with and without polishing, after being immersed in a 0.12% chlorhexidine (CHX)-based mouthwash at different times. The present in vitro experimental and longitudinal study used 96 nanohybrid resin composite blocks (Forma, Tetric N-Ceram and Filtek Z350XT) 8 mm in diameter and 2 mm thick, evenly distributed. Each resin composite group was divided into two subgroups (n = 16) with and without polishing and then immersed in a 0.12% CHX-based mouthwash for 7, 14, 21 and 28 days. Color measurements were performed with a calibrated digital spectrophotometer. Nonparametric tests were used to compare independent (Mann–Whitney U and Kruskal–Wallis) and related (Friedman) measures. In addition, the Bonferroni post hoc correction was used considering a significance level of p < 0.05. All polished and unpolished resin composites presented color variation < 3.3 when immersed for up to 14 days in 0.12% CHX-based mouthwash. The polished resin composite with the lowest color variation (ΔE) values over time was Forma, and the one with the highest values was Tetric N-Ceram. When comparing the color variation (ΔE) over time, it was observed that the three resin composites, with and without polishing, presented a significant change (p < 0.001), although these changes in color variation (ΔE) were evident from 14 days between each color acquisition (p < 0.05). The unpolished Forma and Filtek Z350XT resin composites showed significantly more color variation than the same polished ones at all times when immersed in a 0.12% CHX-based mouthwash for 30 s daily. In addition, every 14 days, all three resin composites with and without polishing showed a significant color change, while, every 7 days, color stability was maintained. All the resin composites showed clinically acceptable color stability when exposed for up to 14 days to the above-mentioned mouthwash.
Collapse
Affiliation(s)
| | | | | | - Marysela Ladera-Castañeda
- Research Team “Salud Pública—Salud Integral”, Faculty of Dentistry, Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | | | - Reynaldo Martínez-Campos
- Oral Rehabilitation Department, School of Stomatology, Universidad Científica del Sur, Lima 15067, Peru
| | | | - Ana Aliaga-Mariñas
- Research Team “Salud Pública—Salud Integral”, Faculty of Dentistry, Postgraduate School, Universidad Nacional Federico Villarreal, Lima 15001, Peru
| | - Arturo Verástegui-Sandoval
- Faculty of Health Sciences, Professional Academic School of Dentistry, Universidad Privada Norbert Wiener, Lima 15046, Peru
| | - César Cayo-Rojas
- School of Stomatology, Universidad Privada San Juan Bautista, Lima 15067, Peru
- Correspondence:
| |
Collapse
|
4
|
de Oliveira NG, Espíndola-Castro LF, Rocha JC, de Barros Albuquerque AP, de Melo Rêgo MJB, de Melo Monteiro GQ, de Vasconcelos Carvalho M. Influence of the self-adhering strategy on microhardness, sorption, solubility, color stability, and cytotoxicity compared to bulk-fill and conventional resin composites. Clin Oral Investig 2022; 26:6663-6670. [PMID: 35916952 DOI: 10.1007/s00784-022-04624-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 07/11/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES To analyze and compare, in vitro, the microhardness, sorption, solubility, color stability, and cytotoxicity of three types of resin composites: self-adhesive (SARC) (Dyad Flow (DF)/Kerr), bulk-fill (Filtek Bulk Fill Flow (FBF)/3 M ESPE), and conventional (Filtek Z350XT Flow (Z350)/3 M ESPE). MATERIALS AND METHODS Thirty cylindrical specimens were prepared using a split metal mold (15 mm × 1 mm), divided into 3 groups (n = 10) according to the material used. Vickers hardness (VH) was calculated from three indentations (300gf/15 s) per specimen. The sorption and solubility were measured according to the ISO 4049:2009 specification after storing in distilled water for 7 days. The color of each resin composite was measured using a portable digital spectrophotometer according to the CIELAB system. After a 7-day immersion in coffee, the color variation (∆E) was calculated. Following the ISO 10993:2012, the cytotoxicity in Vero cells was evaluated through the MTT assay. The results were analyzed using the Kruskal-Wallis test to compare the studied groups. The Wilcoxon test was used to compare the assessments in each studied group. For cytotoxicity analysis, the data were compared by the ANOVA test (α = 0.05). RESULTS DF showed the lowest VH (28.67), highest sorption (0.543 µg/mm3) and solubility (1.700 µg/mm3), and higher ∆E after 7 days of coffee immersion (p = 0.008). The resin composites studied were considered non-cytotoxic. CONCLUSIONS The SARC presented inferior mechanical and physical-chemical properties than bulk-fill and conventional resin composites, with comparable cytotoxicity against Vero cells. CLINICAL RELEVANCE The simplification of the clinical protocol of SARC can minimize the number of possible failures during the restorative technique. However, considering their inferior physical and mechanical properties, their coverage with materials of higher mechanical properties and physical-chemical stability should be considered.
Collapse
Affiliation(s)
- Natália Gomes de Oliveira
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil.
| | - Luís Felipe Espíndola-Castro
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil
| | - Julliana Carvalho Rocha
- Dental School, University of Pernambuco (Campus Arcoverde), Estrada Para Sítio Deserto, Arcoverde, PE, 1940, Brazil
| | | | - Moacyr Jesus Barreto de Melo Rêgo
- Biochemistry Department, Federal University of Pernambuco, Avenida Professor Moraes Rego, 1235, Cidade Universitária, Recife, PE, Brazil
| | - Gabriela Queiroz de Melo Monteiro
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil
| | - Marianne de Vasconcelos Carvalho
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil
| |
Collapse
|
5
|
Color Stability of Orthodontic Ceramic Brackets and Adhesives in Potentially Staining Beverages—In Vitro Study. Dent J (Basel) 2022; 10:dj10070115. [PMID: 35877389 PMCID: PMC9351677 DOI: 10.3390/dj10070115] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 06/14/2022] [Accepted: 06/16/2022] [Indexed: 01/27/2023] Open
Abstract
The aim of this study was to evaluate the color stability of esthetic ceramic brackets and adhesive samples after immersion in most commonly consumed beverages. A hundred ceramic brackets from five different manufacturers (Forestadent®, G&H®, GC, DynaFlex®, and American Orthodontics) and 120 samples of adhesives (3M™Transbond™ XT and American Orthodontics BracePaste® color change adhesive and BracePaste® adhesive) were immersed into four different solutions: coffee, Coca-Cola®, the vitamin drink Cedevita®, and artificial saliva (control group). The samples were kept in an incubator at 37 °C. Color readings were evaluated before (T0), at 24 h (T1), 72 h (T3), 7 days (T4), and 14 days (T5) after initial immersion using a spectrophotometer according to the L*a*b* color scale. All the examined brackets showed a statistically significant difference in discoloration (p = 0.001). 20/40™ Brackets (American Orthodontics) showed the best color stability, while the greatest color modification was recognized in QuicKlear® III (Forestadent®) brackets. Regarding adhesives, the greatest staining was observed in the BracePaste® color change adhesive and the least in the Transbond™ XT samples. In conclusion, color change occurs in all solutions, including control groups, and coffee has the greatest impact on color stability.
Collapse
|
6
|
Optical Behavior and Surface Analysis of Dental Resin Matrix Ceramics Related to Thermocycling and Finishing. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094346] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Color preservation of esthetic dental restorative materials in the oral environment represents, besides longevity, a concern, and there is still limited knowledge related to the effect of aging on the optical behavior of resin matrix ceramics. The study analyzed the finishing and thermocycling of resin matrix ceramic material surfaces, in order to assess their consequences on optical properties. Five resin matrix CAD/CAM ceramics, namely a polymer-infiltrated ceramic and four types of nanoparticle-filled resins, were selected for the study, and finished by polishing and glazing. Thermocycling was chosen as the in vitro aging method. Surface microroughness, optical and hardness evaluations were achieved before and after artificial aging. Statistical analyses were performed with IBM SPSS Statistics software at a significance value of p < 0.05. Micro-roughness values increased after thermocycling, but were kept under the clinically accepted values. The optical characteristics of resin matrix ceramics were not significantly modified by thermocycling. Values of the glazed samples became closer to those of the polished ones, after hydrothermal aging, even if the differences were insignificant. Thermocycling significantly decreased the microhardness, mainly for glazed samples. This could be the consequence of glaze removal during thermocycling, which means that glazes provide a surface protection for a limited time.
Collapse
|
7
|
Paolone G, Formiga S, De Palma F, Abbruzzese L, Chirico L, Scolavino S, Goracci C, Cantatore G, Vichi A. Color stability of resin-based composites: Staining procedures with liquids-A narrative review. J ESTHET RESTOR DENT 2022; 34:865-887. [PMID: 35396818 DOI: 10.1111/jerd.12912] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Revised: 01/30/2022] [Accepted: 03/24/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The objective of this study was to review the experimental staining procedures performed in in-vitro studies for evaluating color stability of resin-based composites used for direct restorations. OVERVIEW A review was performed with the purpose to identify in vitro procedures carried out to establish staining and color stability of resin-based composites used for direct restorations. A literature search was performed on four online databases (PubMed, Scopus, Embase and Web of Science) for articles published from January 1st 2001 till March 20th 2021, using a combination of free words and Medical Subject Headings (MESH) terms: "Composite Resins" AND "Color Stability" OR "Staining." Two reviewers screened titles and/or abstracts of 1728 unique studies. In total, 208 studies were selected for full-text reading, from which 178 were included in the review. The assessed variables were specimen dimensions, shape, and surface finishing; time before immersion; staining media type, dwell time, temperature and renewal interval; type of composite; color and translucency assessment parameters and measuring system. One hundred and seventy-eight articles analyzed color stability with staining liquids. Coffee was the most used staining medium (n = 102), followed by tea (n = 61), and red wine (n = 55). A disc-shaped specimen was used in most studies (n = 170) with a 2 mm thickness (n = 116). Spectrophotometers were the most used color assessment devices (n = 154), followed by colorimeters (n = 17). Color differences were quantified with ΔE (n = 154), ΔE00 (n = 23). Acceptability and or perceptibility thresholds were also taken into consideration (n = 126). CONCLUSIONS The large variety of staining procedure suggests the need for standardization. CLINICAL SIGNIFICANCE Aesthetic failure due to discoloration is a relevant clinical problem. Evaluating benefits and drawbacks of resin based composites artificial staining procedures will improve to predict materials clinical performances.
Collapse
Affiliation(s)
- Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Sara Formiga
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Francesca De Palma
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Luca Abbruzzese
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | - Luca Chirico
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | | | - Cecilia Goracci
- Department of Medical Biotechnologies, University of Siena, Siena, Italy
| | - Giuseppe Cantatore
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, Milan, Italy
| | | |
Collapse
|
8
|
Saati K, Valizadeh S, Anaraki SN, Moosavi N. Effect of aging on color stability of amine-free resin cement through the ceramic laminate veneer. Dent Res J (Isfahan) 2022; 18:99. [PMID: 35003564 PMCID: PMC8672126 DOI: 10.4103/1735-3327.330880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 05/23/2021] [Accepted: 07/01/2021] [Indexed: 11/04/2022] Open
Abstract
Background This study aimed to assess the color change of two amine-free dual-cure resin cements following aging in comparison with a light-cure resin cement. Materials and Methods This in vitro, experimental study evaluated 6 groups (n = 10), including three groups of cements bonded to feldspathic porcelain and three groups of resin cements alone. Panavia V5 (Kuraray) and G-CEM LinkForce (GC) dual-cure resin cements and Choice 2 (Bisco) light-cure resin cements were bonded to porcelain according to the manufacturers' instructions. The color parameters of the groups were measured before and after 5000 thermal cycles by spectrophotometry. Data were analyzed using two-way ANOVA and Tukey's post hoc test (α =0.05). Results The color change (ΔE) of the cement groups alone was significantly greater than that of porcelain-bonded cements. The ΔE of G-CEM LinkForce cement group was significantly higher than that of Panavia V5 group (P = 0.020), and the ΔE of the latter group was significantly higher than that of Choice 2 cement group (P = 0.021). Conclusion Considering the color change of cements evaluated in this study, Choice 2 and Panavia V5 cements bonded to porcelain showed acceptable color change, which indicates that they are suitable for cementation of esthetic dental restorations. Ceramic laminates have become an ideal esthetic treatment for anterior restorations. The resin cement discoloration can affect final appearance of these restorations. Besides that, exposed resin cement line can lead to the esthetic problem over time.
Collapse
Affiliation(s)
- Keyvan Saati
- Department of Restorative, Dental Branch, Islamic Azad University of Medical Sciences, Tehran, Iran
| | - Sara Valizadeh
- Department of Restorative Dentistry, Dental Research Centre, Dentistry Research Institute, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Saeed Nemati Anaraki
- Department of Restorative, Dental Branch, Islamic Azad University of Medical Sciences, Tehran, Iran
| | - Niloufar Moosavi
- Department of Restorative, Islamic Azad University of Medical Sciences, Tehran, Iran
| |
Collapse
|