1
|
Hara J, Ishii S, Kobiyama H, Fukushima K, Kawamoto N, Yamakuni R, Suenaga H, Muto Y, Sugawara S, Sato A, Oikawa M, Takeishi Y, Ito H. A Quantitative Diagnostic Method Using 99mTc-pyrophosphate Lateral Planar Images to Distinguish Between Transthyretin Amyloid Cardiomyopathy and False-Positive Images Due to Blood Pools. ANNALS OF NUCLEAR CARDIOLOGY 2024; 10:23-28. [PMID: 39635326 PMCID: PMC11612392 DOI: 10.17996/anc.24-00001] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/04/2024] [Accepted: 04/01/2024] [Indexed: 12/07/2024]
Abstract
Background: This study investigated the feasibility of using a quantitative diagnostic method based on 99mTc-pyrophosphate scintigraphy (PYP) lateral planar images to differentiate between PYP-positive (myocardial uptake) and false-positive (blood pool uptake) scans. Methods: The study included 93 consecutive patients with suspected transthyretin amyloid cardiomyopathy (ATTR-CM) who underwent PYP between April 2022 and December 2023. Patients were categorized using planar anterior PYP images according to the Perugini visual grading system; patients with grades ≥ 2 were analyzed. Whether the uptake of the ventricle was in the blood pool or the myocardium was confirmed by transaxial single-photon emission tomography (SPECT). The heart-to-mediastinum ratios (H/M ratio) of the left lateral planar images at 1- and 3-h were calculated by placing a circular region of interest in the heart and cephalodorsal side of the heart to determine optimal cut-off values. Results: Among the PYP images, the study analyzed 15 positives diagnosed as ATTR-CM and 10 false positives. Significant differences were observed in the H/M ratio at 1- and 3-h (both p<0.01), with 100% sensitivity and specificity using cut-off values of 1.22 and 1.21 at 1- and 3-h, respectively. The interclass correlation coefficients (2, 1) between the two readers were 0.919 and 0.958 for the 1- and 3-h H/M ratios, respectively. Conclusions: Lateral planar PYP imaging can exclude PYP false-positive cases caused by blood pools in a simple and quantitative manner using only a 1-h planar image, possibly obviating the need for SPECT imaging.
Collapse
Affiliation(s)
- Junko Hara
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Shiro Ishii
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Honami Kobiyama
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Kenji Fukushima
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Natsumi Kawamoto
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Ryo Yamakuni
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Hiroki Suenaga
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Yuuki Muto
- Department of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan
| | - Shigeyasu Sugawara
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| | - Akihiko Sato
- Department of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan
| | - Masayoshi Oikawa
- Department of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan
| | - Yasuchika Takeishi
- Department of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan
| | - Hiroshi Ito
- Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
| |
Collapse
|