Pieh S, Artmayr C, Schartmüller D, Kriechbaum K. IOL decentration sensitivity according to spatial frequencies. BMJ Open Ophthalmol 2024; 9:e001661. [PMID: 39117362 PMCID: PMC11409404 DOI: 10.1136/bmjophth-2024-001661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Accepted: 06/08/2024] [Indexed: 08/10/2024] Open
Abstract
BACKGROUND/AIMS Investigation of the decentration sensitivity of monofocal intraocular implants with a focus on different aberration corrections depending on different spatial frequencies. METHODS Using an optical bench, the decentration sensitivities of an intraocular lens (IOL) with a high spherical aberration correction of -0.27 µm (ZCB00 Johnson & Johnson), an IOL with an aberration correction of -0.20 µm (Primus HD OphthalmoPro) and an IOL with an aberration neutral design (CT Asphina 409MP Carl Zeiss Meditec) were evaluated for Strehl ratio values and for 25, 50 and 100 lp/mm. Two different corneas with +0.13 µm and +0.28 µm were used. The lenses were tested in the best centration and up to a decentration of 0.5 mm. RESULTS Decentration sensitivity affects high spatial frequencies more than lower ones. The possible decentration sensitivity is determined by the amount of spherical aberration of the cornea. The effective decentration sensitivity is determined by the extent to which these spherical aberrations are compensated. If these are not compensated, there is hardly any decentration sensitivity. CONCLUSION High spatial frequencies are more affected by decentration sensitivity. The decentration sensitivity of an IOL is determined by the extent to which the spherical aberration of the cornea is corrected.
Collapse
Affiliation(s)
- Stefan Pieh
- Department of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria
| | - Cornelia Artmayr
- Department of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria
| | - Daniel Schartmüller
- Department of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria
| | - Katharina Kriechbaum
- Department of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
2
|
Chen XY, Wu QR, Xie MY, Zhang D, Zhang C. Bibliometric analysis of research relating to refractive cataract surgery over a 20-year period: from 2003 to 2022. Int J Ophthalmol 2023; 16:1692-1701. [PMID: 37854386 PMCID: PMC10559026 DOI: 10.18240/ijo.2023.10.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 08/01/2023] [Indexed: 10/20/2023] Open
Abstract
AIM To investigate the research trend on refractive cataract surgery, compare the contributions of different countries, institutions, journals, and authors in the past 20y, and explore its potential research hotspots. METHODS All publications were extracted relating to refractive cataract surgery from 2003 to 2022 from Web of Science. Document types were limited to original articles and reviews, and the language was limited to English. Quantitatively and qualitatively of the publications were analyzed through Microsoft Excel and GraphPad Prism. VOSviewer and CiteSpace were used for bibliometric and visualized analysis. RESULTS A total of 2090 publications were enrolled. The United States contributed the most publications (434, 20.8%), followed by China (345, 16.5%) and England (163, 7.80%). Publications from the United States were cited more frequently (9552 citations) with the highest H-index of 48. China ranked second in the total number of publications, the papers were not cited that frequently (3237 citations), and the H-index ranked sixth (H-index=29). Journal of Cataract and Refractive Surgery published the most papers (333, 15.9%), and the University of London had the highest number of publications (75, 3.59%). Dick HB from Germany published the most papers. Corneal astigmatism-related research, cataract surgery method-related research, postoperative visual-quality relate to research, and postoperative complications-relate research are the hotspots in this field. The most significant limitation was that the database was updated frequently and the latest publications were not included. CONCLUSION The bibliometric analysis shows a brief summarization of the contribution of the authors, institutions, countries, and journals. Corneal astigmatism, cataract surgery method, postoperative visual-quality and postoperative complications related researches have become the emerging hotspots, which can give a direction in the future researches.
Collapse
Affiliation(s)
- Xiao-Yong Chen
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing 100191, China
| | - Qian-Ru Wu
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Capital Medical University, Beijing 100730, China
| | - Min-Yue Xie
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Capital Medical University, Beijing 100730, China
| | - Di Zhang
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing 100191, China
| | - Chun Zhang
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing 100191, China
| |
Collapse
|
3
|
Zhang J, Zheng L, Zhang Y, Wang K. Analysis of Asphericity and Corneal Longitudinal Spherical Aberration of 915 Chinese Myopic Adult Eyes. Clin Ophthalmol 2023; 17:591-600. [PMID: 36814783 PMCID: PMC9939669 DOI: 10.2147/opth.s404437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 02/09/2023] [Indexed: 02/16/2023] Open
Abstract
Purpose To analyze the corneal asphericity, longitudinal spherical aberration (LSA), and related factors in Chinese myopic adult eyes. Methods This was a retrospective study of myopic adult patients. The corneal asphericity and LSA were measured at 3.0, 4.0, 5.0, 6.0, and 7.0 mm diameter apertures using corneal tomography. Age and refractive power were recorded for correlation analysis. Results In total, 531 females and 384 males were included. At the above five diameter settings the corneal asphericity values (Q) of the anterior surface were -0.09±0.21, -0.14±0.16, -0.15±0.13, -0.17±0.11, and -0.20±0.11, and those of the posterior surface were 0.23±0.49, 0.06±0.29, -0.01±0.22, -0.07±0.16, and -0.08±0.15, respectively. The anterior corneal LSA values at these diameters were 0.39±0.19, 0.63±0.27, 0.97±0.36, 0.90±0.30, and 0.83±0.29 D, respectively and the whole corneal values were 0.26±0.20, 0.44±0.27, 0.70±0.36, 0.66±0.30, and 0.59±0.28 D, respectively. Corneal asphericity and peripheral LSA showed no or weak correlation with age or spherical equivalent (all r < 0.2). Conclusion Corneal anterior and posterior Q values in myopia patients are negatively correlated with corneal diameter. Corneal anterior and whole corneal LSA increased significantly with diameter up to 5 mm, then decreased slightly with diameter. Corneal asphericity and peripheral LSA showed very weak or no correlation with age or spherical equivalent. Clinical Trial Registration Number ChiCTR1800015985.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China,Correspondence: Jun Zhang, Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China, Tel +86-18667046602; +86-0571 85064148, Email
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Yixuan Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Ke Wang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| |
Collapse
|
4
|
Hirabayashi MT, Gharabagi AP, Hesemann NP, Johnson SM, Webel AD, Petroski GF, Davis GR. Spherical Aberration of Cataractous Eyes and Its Relationship With Age, Ocular Biometry, and Various IOL Platforms. J Refract Surg 2023; 39:89-94. [PMID: 36779463 DOI: 10.3928/1081597x-20221207-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
PURPOSE To determine the median spherical aberration (SA) of the cataractous population, how it relates to biometry, and the theoretical effect of different intraocular lens (IOL) platforms. METHODS A retrospective chart review of patients undergoing cataract surgery evaluation with a high quality Pentacam (Oculus Optikgeräte GmbH) were included. Age, gender, Q-value, mean total SA, higher order aberration root mean square wavefront error, and equivalent keratometry were collected from the Holladay report and axial length and anterior chamber depth (ACD) from the IOLMaster 700 (Carl Zeiss Meditec AG). RESULTS Data from 1,725 eyes of 999 patients were collected. SA had a median of 0.37 µm (95% confidence interval: 0.36 to 0.38. Age (r = .136, P < .001), Q-factor (r = .743, P < .001), and higher order aberration root mean square wavefront error (r = .307, P < .001) were positively correlated with SA. Average equivalent keratometry (r = -.310, P < .001) was negatively correlated with SA. Axial length (r = -0.037, P = .120) and ACD (r = .004, P = .856) had no association with SA. Up to 1,499 (86.9%) theoretically had SA moved closer to zero with IOLs that had negative SA. Up to 102 (5.9%) had SA theoretically worsened. CONCLUSIONS SA is not normally distributed, suggesting that there may be no "average" SA that IOLs should aim to correct. Patients might benefit from tailoring IOL choice to individual SA. Without access to SA data, eyes with steeper average keratometry or younger patients may have less SA, which could influence IOL choice. [J Refract Surg. 2023;39(2):89-94.].
Collapse
|
5
|
Duan L, Dang G, Ge J, Gao Y, Wang L. Visual function assessment of Chinese cataract patients after individual aspheric intraocular lens implantation according to preoperative cornea spherical aberration. Technol Health Care 2022; 31:831-839. [PMID: 36442220 DOI: 10.3233/thc-220154] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
BACKGROUND: Aspheric intraocular lens (IOLs) implantation has been widely applied in cataract surgery. However, there is no consensus on the optimal guidance for the operations in IOLs implantation. OBJECTIVE: This study evaluated the visual function of Chinese cataract patients six months after cataract surgery with two different guiding ideologies. METHODS: We evaluated 50 patients (61 eyes) with implantation of different aspheric IOLs (SN60WF IOLs, ZCB00 IOLs, PY-60AD IOLs, AO IOLs) 6 months after cataract surgery. Twenty-four patients (30 eyes) under individual implantation were ascribed to group 1 and 26 patients (31 eyes) with randomized implantation were ascribed to the control group (group 2). Postoperatively parameters included monocular best-corrected visual acuity (BCVA), contrast sensitivity (CS), total spherical aberration Z (4, 0) at 5 mm pupil size, and patient satisfaction. The quality of life after operation was assessed through the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). RESULTS: Six months after cataract operation, the contrast sensitivity with glare of group 1 at 2.5∘ was 0.697 ± 0.027, and 0.532 ± 0.049 in group 2. Besides, there was no significant difference at any other special frequency. The mean spherical aberration Z (4, 0) at 5 mm pupil size in group 1 was 0.015 ± 0.028 um, and in group 2 was 0.043 ± 0.109 um, with a significant difference (p< 0.01). The mean scores obtained from NEI VFQ-25 were not significantly different. CONCLUSION: It is effective to implant aspheric IOLs individually according to preoperative corneal spherical aberration. Patients obtained better contrast sensitivity with glare at 2.5∘, but there was no significant difference in BCVA, contrast sensitivity at other special frequency, and subjective visual function.
Collapse
Affiliation(s)
- Lian Duan
- Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China
- Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China
| | - Guangfu Dang
- Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China
- Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China
| | - Jinling Ge
- Mingshui Eye Hospital, Jinan, Shandong, China
- Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China
| | - Yang Gao
- Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China
| | - Lihua Wang
- Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China
| |
Collapse
|
6
|
Langenbucher A, Szentmáry N, Cayless A, Münninghoff L, Wortmann R, Wendelstein J, Hoffmann P. Translation model for anterior segment tomographic data to corneal spherical aberration derived from a Monte-Carlo simulation based on raytracing. Acta Ophthalmol 2022; 100:e1665-e1674. [PMID: 35233935 DOI: 10.1111/aos.15125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/23/2022] [Accepted: 02/18/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Intraocular lenses with a negative aspherical design for correction of corneal spherical aberration (SA) have gained popularity in recent decades. In most cases, a 'one size fits all' concept is followed, where all eyes receive lenses with the same SA correction. The purpose of this study is to develop a strategy based on raytracing using anterior segment tomography data to extract corneal SA and to provide simple multivariable linear models for prediction of corneal SA. METHODS The analysis was based on a large dataset of 8737 measurements of 8737 eyes from 1 clinical centre, using the Casia2 anterior segment tomographer. An optical model based on: corneal front and back surface radius Ra and Rp, asphericities Qa and Qp, corneal thickness CCT, anterior chamber depth ACD, and pupil centre position (X-Y position: PupX and PupY ), was defined for each measurement. Corneal SA was derived using a 6-mm aperture perpendicular to the incident ray and centred on the chief ray, and linear prediction models were derived for SA using biometric data. Cross-validation was used for model performance evaluation. RESULTS Using raytracing, the wavefront error within an aperture (6-mm diameter centred on the intersection of the chief ray with the cornea) was calculated and corneal SA was extracted. After identifying the relevant effect sizes (Ra, Qa, Rp Qp, ACD, PupX and PupY ) using stepwise linear regression, linear mixed-effects models (model 1: all effect sizes, model 2: Ra, Qa, Rp and Qp, model 3: Ra and Qa) were set up on the training data in terms of a Monte-Carlo simulation. On the test data (training data), model 1 with a mean absolute/root-mean-squared prediction error of 0.0095/0.0130 (0.0095/0.0127) performed similarly to model 2 with 0.0097/0.0131 (0.0096/0.0127), and both outperformed model3 with 0.0152/0.0197 (0.0148/0.0190). CONCLUSION Based on the Casia2 anterior segment tomographer, corneal SA could be derived using shape data (curvature and asphericities) of both corneal surfaces (model 2). This information could easily be used for selection of the appropriate negative aspherical lens design in cataract surgery.
Collapse
Affiliation(s)
- Achim Langenbucher
- Department of Experimental Ophthalmology Saarland University Homburg/Saar Germany
| | - Nóra Szentmáry
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research Saarland University Homburg/Saar Germany
- Department of Ophthalmology Semmelweis‐University Budapest Hungary
| | - Alan Cayless
- School of Physical Sciences The Open University Milton Keynes UK
| | | | | | - Jascha Wendelstein
- Department of Experimental Ophthalmology Saarland University Homburg/Saar Germany
- Medical Faculty Johannes Kepler University Linz Linz Austria
| | - Peter Hoffmann
- Augen‐ und Laserklinik Castrop‐Rauxel Castrop‐Rauxel Germany
| |
Collapse
|
7
|
Visual and patient-reported factors leading to satisfaction after implantation of diffractive EDOF and trifocal intraocular lenses. J Cataract Refract Surg 2021; 48:421-428. [PMID: 34417785 DOI: 10.1097/j.jcrs.0000000000000780] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 08/06/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate factors that influence postoperative satisfaction in patients with diffractive EDOF and multifocal IOLs. SETTING Department of Ophthalmology, Goethe University Frankfurt, Germany. DESIGN Observational case study. METHODS Patients were evaluated after implantation of a diffractive EDOF (Symfony, J&J, USA; AT LARA, CZM, Germany) or tri-/quadrifocal (AT LISAtri, CZM, Germany; Panoptix, Alcon, USA) 3 months postoperatively. A subjective refraction was performed, uncorrected and corrected visual acuity was tested for distance (UDVA, CDVA), intermediate (at 60 & 80cm, UIVA, DCIVA), and near (at 40cm, UNVA, DCNVA). A test for contrast sensitivity was done and the patients filled out two different questionnaires on daily activities and optical phenomena. Parameters with a potential correlation to the postoperative overall satisfaction were investigated. RESULTS We included 94 patients with a mean age of 66 years ± 19. Patients with a better UDVA and UIVA at 60cm were more likely to choose the same IOL again. The intensity of subjective optical phenomena and the visual quality at different tasks of daily living influenced the overall satisfaction. UIVA at 80cm, UNVA, and corrected VA demonstrated no significant influence on patient satisfaction. The uncorrected visual acuity at specific distances had a direct impact on the subjective visual quality regarding the task performed at those distances. CONCLUSION For patients with diffractive EDOF and multifocal IOLs, the UDVA and UIVA at 60cm seem to be more important than the UNVA and UIVA at 80cm. Subjective visual quality and optical phenomena influence patient satisfaction, as well.
Collapse
|
8
|
Elkitkat RS, Fouad YA, Shams A, Hamza I. Normative Values of Corneal Spherical Aberration, Pupil Size, and Other Key Refractive and Topographic Parameters in a Large Cohort of Egyptian Cataract Surgery Candidates. Clin Ophthalmol 2020; 14:4571-4577. [PMID: 33408459 PMCID: PMC7781024 DOI: 10.2147/opth.s288738] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 12/03/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose To determine the spherical aberration, pupil size, and other key refractive and topographic parameters in a large cohort of Egyptian cataract surgery candidates, and to investigate any existent relations between the spherical aberration and other possibly related parameters. Methods This is a cross-sectional, descriptive study that was conducted at Ain Shams University Hospitals, Cairo, Egypt. The study was performed on the right eyes of 1658 cataract surgery candidates. The mean corneal spherical aberration [Z4] and the pupil diameter, both photopic [P. Pupil] and mesopic [M. Pupil], were measured by the Oculus Keratograph 3, while the white-to-white corneal diameter [WTW], average keratometric readings [average K], axial length measurements [AL] and Anterior Chamber Depth [ACD] were all obtained from the IOL Master 500. Results The mean age was 65 ± 11.3 years. The mean value of the Z4 was +0.26 ± 0.12 μm [95% Confidence Interval “CI” (0.2570–0.2681)]. The mean values of the measured parameters were: P. Pupil 2.43 ± 0.87 mm [95% CI (2.3867–2.4700)], M. Pupil 4.61 ± 0.91 mm [95% CI (4.5683–4.6557)], WTW 11.72 ± 0.44 mm [95% CI (11.6969–11.7394)], average K 43.89 ± 1.89 D [95% CI (43.7938–43.9701)], AL 24.23 ± 2.21 mm [95% CI (24.1118–24.3166)], and ACD 3.16 ± 0.43 mm [95% CI (3.1414–3.1827)]. Weak statistically significant correlations were found between the Z4 and each of age (r = 0.049, p = 0.044), average K (r = 0.191, p < 0.001), and ACD (r = 0.122, p < 0.001). Multivariate analysis showed weaker relations between Z4 and both average K (beta coefficient= 0.091) and ACD (beta coefficient= 0.130), with an r2 = 0.024. Conclusion This is the first normative data report of corneal spherical aberration [Z4], pupil size, and related refractive and topographic parameters in an old Egyptian population. The detected correlations have a weak clinical relevance and negate the existence of significant relations between the Z4 and the studied refractive and topographic parameters.
Collapse
Affiliation(s)
- Rania Serag Elkitkat
- Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt.,Watany Eye Hospital, Cairo, Egypt.,Watany Research and Development Center, Cairo, Egypt
| | - Yousef A Fouad
- Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Abdelrhman Shams
- Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Ismail Hamza
- Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| |
Collapse
|
9
|
Pérez-Gracia J, Ávila FJ, Ares J, Vallés JA, Remón L. Misalignment and tilt effect on aspheric intraocular lens designs after a corneal refractive surgery. PLoS One 2020; 15:e0243740. [PMID: 33315894 PMCID: PMC7735572 DOI: 10.1371/journal.pone.0243740] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Accepted: 11/26/2020] [Indexed: 12/19/2022] Open
Abstract
PURPOSE To numerically evaluate and compare the tolerance to misalignment and tilt of aspheric intraocular lenses (IOLs) designed for three eyes: with standard cornea and with simulated corneas after myopic and hyperopic laser ablation surgery. METHODS Three aspheric IOLs of +20.00 diopter (D) with different spherical aberration (SA) ([Formula: see text]) values have been designed using a theoretical model eye. Drastic changes on the theoretical eye anterior corneal asphericity have been performed to simulate myopic and hyperopic refractive surgeries. The effect of IOL misalignment and tilt on the image quality has been evaluated using a commercial optical software design for the three eye models. Image quality was assessed from the modulation transfer function (MTF), root mean square (RMS) values of defocus, astigmatism, coma and spherical aberration ([Formula: see text]), and retinal images obtained from a visual simulator using an aleatory optotype of 0.00 LogMar visual acuity (VA). RESULTS IOL misalignment and tilt reduced MTF values in general, and increased wavefront aberrations errors. Aberration-free IOLs maintained best the MTF values when misalignments were applied, together with good on-axis optical quality. IOLs with negative SA ([Formula: see text]) correction decreased the MTF value under 0.43 for misalignments values higher than 0.50 mm with the three corneas. The effect of misalignment on RMS astigmatism and coma was correlated with the IOL SA ([Formula: see text]) and with the three corneas. CONCLUSIONS This theoretical study shows that the largest degradation in image quality arises for the IOL with the highest amount of spherical aberration ([Formula: see text]). Moreover, it has been found that the aspherical design has a more influential role in misalignment tolerance than in tilt tolerance.
Collapse
Affiliation(s)
- Jesús Pérez-Gracia
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Francisco J. Ávila
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Jorge Ares
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Juan A. Vallés
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Laura Remón
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| |
Collapse
|