1
|
Zha F, Feng C, Xu J, Zou Q, Li J, Hu D, Liu WV, Li Z, Wu S. Evaluation of multiplexed sensitivity encoding diffusion-weighted imaging in detecting uterine lesions: Image quality optimization. Magn Reson Imaging 2024; 110:17-22. [PMID: 38452829 DOI: 10.1016/j.mri.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 03/03/2024] [Accepted: 03/03/2024] [Indexed: 03/09/2024]
Abstract
PURPOSE To compare the image quality of multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) and single-shot echo-planar imaging (SS-EPI-DWI) techniques in uterine MRI. METHODS Eighty-eight eligible patients underwent MUSE-DWI and SS-EPI-DWI examinations simultaneously using a 3.0 T MRI system. Two radiologists independently performed quantitative and qualitative analysis of the two groups of images using a double-blind method. The weighted Kappa test was used to evaluate the interobserver agreement. Wilcoxon's rank sum test was used for qualitative parameters, and paired t-test was used for quantitative parameters. Spearman rank correlation analysis was used to obtained correlation between pathological results and mean apparent diffusion coefficient (ADC) value. RESULTS The qualitative and quantitative analysis of the images by the two radiologists were in good or excellent agreement, with weighted kappa value ranging from 0.636 to 0.981. The scores of total subjective image quality (15.4 ± 0.99) and signal-to-noise ratio (158.99 ± 60.71) of MUSE-DWI were significantly higher than those of SS-EPI-DWI (12.93 ± 1.62 P < 0.001; 130.23 ± 48.29 P < 0.05). It effectively reduced image distortion and artifact, and had better lesion conspicuity. There was no significant difference in contrast-to-noise ratio score and average ADC values between the two DWI sequences. The average ADC values of the two DWI sequences were highest in the normal uterus group and lowest in the endometrial cancer group, with statistically significant differences among groups (P < 0.01). In addition, the average ADC values of the two DWI sequences were negatively correlated with the type of lesions, decreasing with the malignancy of the lesions (r = -0.805 P < 0.01, r = -0.815 P < 0.01). CONCLUSION Compared to SS-EPI-DWI, MUSE-DWI can significantly reduce distortion, artifacts, and fuzziness in MRI of uterine lesions, which is more conducive to lesion detection.
Collapse
Affiliation(s)
- Fuxiang Zha
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Cui Feng
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Jin Xu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Qian Zou
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Jiali Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Daoyu Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | | | - Zhen Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Sisi Wu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China.
| |
Collapse
|
2
|
Zhao W, Ju S, Yang H, Wang Q, Fang L, Pylypenko D, Wang W. Improved Value of Multiplexed Sensitivity Encoding DWI with Reversed Polarity Gradients in Diagnosing Prostate Cancer: A Comparison Study with Single-Shot DWI and MUSE DWI. Acad Radiol 2024; 31:909-920. [PMID: 37778902 DOI: 10.1016/j.acra.2023.08.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/16/2023] [Accepted: 08/21/2023] [Indexed: 10/03/2023]
Abstract
RATIONALE AND OBJECTIVES This study aimed to investigate the value of multiplexed sensitivity encoding with reversed polarity gradients in improving the quality of diffusion-weighted imaging (DWI) images of the prostate and the diagnostic efficacy of prostate cancer. MATERIALS AND METHODS Seventy-three patients with prostate disease underwent multiplexed sensitivity encoding with reversed polarity gradients (RPG-MUSE), multiplexed sensitivity encoding (MUSE), and single-shot echo-planar imaging (ssEPI) DWI. Three radiologists performed a qualitative image analysis of the three DWI sequences. Qualitative image analysis included artifact minimization, anatomical detail, and sharpness of prostate edges. Two radiologists measured the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion rate, and the apparent diffusion coefficient (ADC) values of the prostate disease tissue. Two radiologists jointly performed Prostate Imaging Reporting and Data System scoring of prostate lesions and compared the diagnostic efficacy of the three DWI sequences for prostate cancer. RESULTS There was good agreement among radiologists in the evaluation and measurement of the three DWI sequence images (intraclass correlation coefficient >0.75, P < 0.05). The RPG-MUSE DWI images were rated higher than those of MUSE and ssEPI in terms of artifact minimization, anatomical details, and sharpness of prostate edges (P < 0.05). The SNR and CNR of the RPG-MUSE DWI images were higher than those of MUSE and ssEPI (P < 0.05), and the geometric distortion rate was lower than that of the other two sequences (P < 0.05). There were no statistical differences in ADC values between the three DWI sequences (P > 0.05). The diagnostic efficacy of RPG-MUSE and MUSE DWI was higher than that of ssEPI (P < 0.017). CONCLUSION RPG-MUSE can reduce the artifacts and geometric distortion in DWI images of the prostate, improve the SNR and CNR of the images, improve the clarity of anatomical details and boundaries without affecting the measurement of ADC values, has the potential to improve the diagnostic efficacy of prostate lesions, and facilitates the clear display and accurate assessment of prostate lesions.
Collapse
Affiliation(s)
- Wenjing Zhao
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Shiying Ju
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Hongyang Yang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Qi Wang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Longjiang Fang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | | | - Wenjuan Wang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.).
| |
Collapse
|
3
|
Wang X, Wang P, Zhang H, Wang X, Shi J, Hu S. Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions. Jpn J Radiol 2024; 42:268-275. [PMID: 37819591 DOI: 10.1007/s11604-023-01500-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/26/2023] [Indexed: 10/13/2023]
Abstract
PURPOSE To compare multiplexed sensitivity-encoding diffusion-weighted magnetic resonance imaging (MUSE-DWI) and conventional DWI (cDWI) techniques in thyroid MRI. MATERIALS AND METHODS Nineteen patients who underwent thyroid MRI using both MUSE-DWI and cDWI at a 3.0 T MRI system were enrolled. Qualitative parameters (image quality, thyroid contour, and lesion conspicuity) and quantitative parameters (signal-to-noise ratio (SNR), lesion-to-thyroid contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC)) were compared between the two sequences. In addition, ADC values derived from MUSE-DWI and cDWI were separately compared between benign and malignant lesions. RESULTS MUSE-DWI outperformed cDWI in terms of image quality, thyroid contour, and lesion conspicuity. Significantly, higher signal-to-noise ratio (SNR) in both the thyroid and its lesion were found in MUSE-DWI than those in cDWI (both P < 0.05). The lesion-to-thyroid contrast-to-noise ratio (CNR) values were also significantly higher in MUSE-DWI than those in cDWI (P < 0.05). The apparent diffusion coefficient (ADC) of the thyroid in MUSE-DWI was significantly lower than that in cDWI (P < 0.05). The ADC of the lesion in MUSE-DWI was also significantly lower than that in cDWI (P < 0.05). In addition, ADC values derived from MUSE-DWI and cDWI were significantly higher in benign lesions than malignant lesions (P < 0.05). CONCLUSION Compared with cDWI, MUSE-DWI can improve the image quality, thyroid contour sharpness, lesion conspicuity, SNR in both the thyroid and its lesions, and enhancing the CNR between lesions and thyroid.
Collapse
Affiliation(s)
- Xiuyu Wang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Peng Wang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Heng Zhang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Xian Wang
- Department of Radiology, Affiliated Renmin Hospital, Jiangsu University, No.8, Dianli Road, Zhenjiang, 212000, Jiangsu, China
| | - Jie Shi
- GE Healthcare, Beijing, 100000, China
| | - Shudong Hu
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China.
| |
Collapse
|
4
|
Mao L, Li Y, Cui B, Lu L, Dou W, Pylypenko D, Zhu J, Li H. Multiparametric MRI for Staging of Bowel Inflammatory Activity in Crohn's Disease with MUSE-IVIM and DCE-MRI: A Preliminary Study. Acad Radiol 2024; 31:880-888. [PMID: 37730492 DOI: 10.1016/j.acra.2023.08.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 08/20/2023] [Accepted: 08/23/2023] [Indexed: 09/22/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate if the combination of multishot diffusion imaging-based multiplexed sensitivity encoding intravoxel incoherent motion (MUSE-IVIM) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is feasible for staging Crohn's disease (CD) activity. MATERIALS AND METHODS A total of 65 CD patients were enrolled and analyzed in this retrospective study. The simplified endoscopic score for Crohn's disease (SES-CD) and magnetic resonance index of activity (MaRIA) were used as the reference. The MUSE-IVIM and DCE-MRI data were acquired at 3.0-T MRI scanner and processed by two radiologists. Three MUSE-IVIM parameters: fast apparent diffusion coefficient (ADCfast), slow apparent diffusion coefficient (ADCslow), and the fractional perfusion (Fraction of ADCfast), as well as four DCE-MRI parameters: volume transfer constant (Ktrans), rate constant (Kep), extravascular extracellular volume fraction (Ve), and plasma volume fraction (Vp) were generated. Intraclass correlation coefficient (ICC), non-parametric test (Kruskal-Wallis H and Mann-Whitney U), logistic regression, receiver operating characteristic analysis, Delong test, and Spearman's correlation test were performed. RESULTS According to SES-CD, 116 ileocolonic segments with CD lesions were identified as: inactive, mild, and moderate to severe. With multivariable logistic regression analysis, ADCfast (p < 0.001), Fraction of ADCfast (p = 0.005), Ktrans (p < 0.001) and Kep (p = 0.003) were identified as significant factors for differentiating among the three groups. Binary logistic analyses identified ADCfast (p = 0.001), Ktrans (p = 0.014), and Kep (p = 0.029) as independent predictors for the active status. The combination of ADCfast, Ktrans, and Kep performed better than MaRIA score (p = 0.028), for differentiating inactive and active status. MaRIA score was positively correlated with ADCfast (p < 0.001), Ktrans (p < 0.001), Kep (p < 0.001), and Ve (p = 0.001), however, negatively correlated with Fraction of ADCfast (p < 0.001). CONCLUSION The combination of MUSE-IVIM and DCE-MRI has been demonstrated to accurately stage inflammatory activity in CD.
Collapse
Affiliation(s)
- Liangqiang Mao
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Yan Li
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Bota Cui
- Department of Gastroenterology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Lin Lu
- Department of Radiology, Columbia University Medical Center, New York, New York
| | - Weiqiang Dou
- GE Healthcare, MR Research China, Beijing, PR China
| | | | - Jianguo Zhu
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China.
| | - Haige Li
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| |
Collapse
|
5
|
Wang YF, Ren Y, Zhu CF, Qian L, Yang Q, Deng WM, Zou LY, Liu Z, Luo DH. Optimising diffusion-weighted imaging of the thyroid gland using dedicated surface coil. Clin Radiol 2022; 77:e791-e798. [PMID: 36096939 DOI: 10.1016/j.crad.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 07/06/2022] [Accepted: 07/08/2022] [Indexed: 11/03/2022]
Abstract
AIM To assess the feasibility of applying field-of-view (FOV) optimised and constrained undistorted single-shot (FOCUS) diffusion-weighted imaging (DWI) in the thyroid gland by comparing its image quality with conventional DWI (C-DWI) qualitatively and quantitatively using a dedicated surface coil exclusively designed for the thyroid gland at 3 T magnetic resonance imaging (MRI). MATERIALS AND METHODS In this prospective study, 32 healthy volunteers who had undergone 3 T the thyroid gland MRI with FOCUS-DWI and C-DWI were enrolled. Two independent reviewers assessed the overall image quality, artefacts, sharpness, and geometric distortion based on a five-point Likert scale. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were quantified for both sequences. Interobserver agreement, qualitative scores, and quantitative parameters were compared between two sequences. RESULTS Agreement between the two readers was good for FOCUS-DWI (κ = 0.714-0.778) and moderate to good for C-DWI (κ = 0.525-0.672) in qualitative image quality assessment. Qualitatively, image quality (overall image quality, artefacts, sharpness, and geometric distortion) was significantly better in FOCUS-DWI than that in the C-DWI (all p<0.05); however, quantitatively, FOCUS-DWI had significantly lower SNRs (p<0.001) and CNRs (p=0.012) compared with C-DWI. The ADC value on FOCUS-DWI was significantly higher than that on C-DWI (p<0.001). CONCLUSION FOCUS-DWI depicted the thyroid gland with significantly better image quality qualitatively and less ghost artefacts, but had significantly lower SNR and CNR quantitatively, compared with C-DWI, suggesting that both DWI sequences have advantages and could be chosen for different purposes.
Collapse
Affiliation(s)
- Y F Wang
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China
| | - Y Ren
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China
| | - C F Zhu
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China
| | - L Qian
- MR Research, GE Healthcare, Beijing, China
| | - Q Yang
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China
| | - W M Deng
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China
| | - L Y Zou
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China
| | - Z Liu
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China.
| | - D H Luo
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China; Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| |
Collapse
|
6
|
Johansson J, Lagerstrand K, Ivarsson L, Svensson PA, Hebelka H, Maier SE. Brain diffusion MRI with multiplexed sensitivity encoding for reduced distortion in a pediatric patient population. Magn Reson Imaging 2022; 87:97-103. [PMID: 34999160 DOI: 10.1016/j.mri.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/30/2021] [Accepted: 01/04/2022] [Indexed: 10/19/2022]
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) is a valuable tool for routine imaging of the pediatric brain. However, the commonly used single-shot (ss) echo-planar imaging (EPI) DWI sequence is prone to geometric distortions and T2*-blurring. This study aimed to investigate in a pediatric population the benefits of using multiplexed sensitivity-encoding (MUSE) without and with reversed polarity gradients (RPG) instead. METHODS This retrospective study compared image quality, geometric distortions, and diffusion values between three different approaches for DWI (ssEPI, MUSE, and RPG-MUSE) in 14 patients (median age = 4 (0.6-15) years, 11 males). Distortion levels were quantified and compared in two brain regions, i.e., the brain stem and the temporal lobes, using the Dice Coefficient and the Hausdorff Distance, with T2-weighted images as reference. Expected geometrical distortion was further evaluated by comparing the effective echo spacing between the DWI sequences. Apparent diffusion coefficient (ADC) values were determined in the genu of the corpus callosum and the optic nerves. Two raters graded overall image quality and image distortions on a Likert scale. RESULTS Distortion levels assessed with Dice coefficient and Hausdorff distance were significantly lower for MUSE (p < 0.05) and RPG-MUSE (p < 0.01) compared to ssEPI. No significant difference in ADC values was observed between methods. The RPG-MUSE method was graded by one rater as significantly higher in overall image quality than ssEPI (p < 0.05) and by both raters as significantly lower in levels of image distortions than both MUSE (p < 0.05) and ssEPI (p < 0.05). These results were in agreement with the reduced effective echo spacing was that was attained with MUSE and RPG-MUSE. CONCLUSION For imaging of the pediatric brain, MUSE and even more so RPG-MUSE offers both improved geometric fidelity and image quality compared to ssEPI.
Collapse
Affiliation(s)
- Jens Johansson
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Kerstin Lagerstrand
- Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Liz Ivarsson
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Pär-Arne Svensson
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Hanna Hebelka
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Stephan E Maier
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
7
|
Abstract
The National Cancer Institute's Quantitative Imaging Network (QIN) has thrived over the past 12 years with an emphasis on the development of image-based decision support software tools for improving measurements of imaging metrics. An overarching goal has been to develop advanced tools that could be translated into clinical trials to provide for improved prediction of response to therapeutic interventions. This article provides an overview of the successes in development and translation of new algorithms into the clinical workflow by the many research teams of the Quantitative Imaging Network.
Collapse
|