1
|
Qu H, Abulimiti A, Liang J, Zhou S, Wu Z, Chen Y, Ju R, Wang Z, Xu R, Chen X. Comparison of short-term clinical outcomes of a diffractive trifocal intraocular lens with phacoemulsification and femtosecond laser assisted cataract surgery. BMC Ophthalmol 2024; 24:189. [PMID: 38658894 PMCID: PMC11040763 DOI: 10.1186/s12886-024-03440-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Accepted: 04/09/2024] [Indexed: 04/26/2024] Open
Abstract
PURPOSE To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN A retrospective, observational study. METHODS Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.
Collapse
Affiliation(s)
- Haokun Qu
- Aier Eye Hospital, Jinan University, No. 191, Huanshi Middle Road, Yuexiu District, Guangzhou, Guangdong, China
- Jinan University, No.601, Huangpu Road West, Guangzhou, China
| | - Adilamu Abulimiti
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Shanghai, China
| | - Jianheng Liang
- Aier Eye Hospital, Jinan University, No. 191, Huanshi Middle Road, Yuexiu District, Guangzhou, Guangdong, China
| | - Suowang Zhou
- Jinan University, No.601, Huangpu Road West, Guangzhou, China
| | - Zheming Wu
- Aier Eye Hospital, Jinan University, No. 191, Huanshi Middle Road, Yuexiu District, Guangzhou, Guangdong, China
| | - Yun Chen
- Aier Eye Hospital, Jinan University, No. 191, Huanshi Middle Road, Yuexiu District, Guangzhou, Guangdong, China
| | - Ruihong Ju
- Aier Eye Hospital, Jinan University, No. 191, Huanshi Middle Road, Yuexiu District, Guangzhou, Guangdong, China
| | - Zheng Wang
- Aier Eye Hospital, Jinan University, No. 191, Huanshi Middle Road, Yuexiu District, Guangzhou, Guangdong, China
- Jinan University, No.601, Huangpu Road West, Guangzhou, China
| | - Rong Xu
- Hankou Aier Eye Hospital, Wuhan, China
| | - Xu Chen
- Jinan University, No.601, Huangpu Road West, Guangzhou, China.
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Shanghai, China.
- Department of Ophthalmology, Shanghai Aier Qingliang Eye Hospital, Qingpu, Shanghai, China.
- Department of Ophthalmology & Optometry, SinoUnited Health Clinic, Shanghai, China.
| |
Collapse
|
2
|
Waring GO, Brujic M, McGee S, Micheletti JM, Zhao C, Schachter S, Liu H, Safyan E. Impact of presbyopia treatment pilocarpine hydrochloride 1.25% on night-driving performance. Clin Exp Optom 2023:1-8. [PMID: 38044272 DOI: 10.1080/08164622.2023.2279189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 10/31/2023] [Indexed: 12/05/2023] Open
Abstract
CLINICAL RELEVANCE Patients prescribed pilocarpine ophthalmic solution are advised to be cautious when driving at night, but studies evaluating the effects of pilocarpine hydrochloride ophthalmic solution 1.25% (pilo), approved to treat presbyopia, on driving at night are lacking. BACKGROUND This double-masked, crossover, phase 3b study evaluated night-driving performance with pilo or the placebo once daily. METHODS Forty-three adults (40-55 years) with presbyopia impacting daily activities and mesopic, high-contrast, binocular distance-corrected near vision 6/12-6/30 were randomised to bilateral treatment with pilo followed by placebo or placebo followed by pilo (with a ≥7-day washout between interventions). Night-driving performance was evaluated at twilight at a closed-circuit course. Primary efficacy endpoint: overall composite night-driving performance Z score at the end of the 7-14-day intervention period, 1 hour post-instillation. Pilo was considered non-inferior if the lower limit of the 95% confidence interval (CI) for the least squares mean difference (LSMD, pilo minus placebo) was >-0.25. Other efficacy endpoints: individual components of the night-driving performance test (hazard avoidance rate; road sign recognition rate and distance; pedestrians recognition distance; overall driving and lane-keeping times) and night-driving experience questionnaire. Safety included treatment-emergent adverse events (TEAEs). RESULTS The mean overall composite Z scores were -0.121 (pilo) and 0.118 (placebo). The LSMD (pilo minus placebo) was -0.224 (95% CI, -0.346, -0.103), with 3 of the 7 individual tasks being significantly better with the placebo. The questionnaire did not reveal significant differences between pilo and the placebo. There were no serious or severe TEAEs and no TEAE-related discontinuations. The most common ocular TEAEs were headache and visual impairment with pilo (both 27.9%), and dry eye (7.0%) with the placebo. CONCLUSION The overall performance of night driving was inferior with pilo, compared with placebo. The study findings are consistent with the current class labelling and provide evidence to inform regulators and assist clinicians considering prescribing pilo to adults who seek treatment of presbyopia symptoms and drive at night.ClinicalTrials.gov identifier: NCT04837482.
Collapse
Affiliation(s)
| | - Mile Brujic
- Premier Vision Group, Bowling Green, OH, USA
| | | | | | - Cathy Zhao
- Allergan, an AbbVie company, Irvine, CA, USA
| | | | - Haixia Liu
- Allergan, an AbbVie company, Irvine, CA, USA
| | | |
Collapse
|
3
|
Chen XY, Wu QR, Xie MY, Zhang D, Zhang C. Bibliometric analysis of research relating to refractive cataract surgery over a 20-year period: from 2003 to 2022. Int J Ophthalmol 2023; 16:1692-1701. [PMID: 37854386 PMCID: PMC10559026 DOI: 10.18240/ijo.2023.10.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 08/01/2023] [Indexed: 10/20/2023] Open
Abstract
AIM To investigate the research trend on refractive cataract surgery, compare the contributions of different countries, institutions, journals, and authors in the past 20y, and explore its potential research hotspots. METHODS All publications were extracted relating to refractive cataract surgery from 2003 to 2022 from Web of Science. Document types were limited to original articles and reviews, and the language was limited to English. Quantitatively and qualitatively of the publications were analyzed through Microsoft Excel and GraphPad Prism. VOSviewer and CiteSpace were used for bibliometric and visualized analysis. RESULTS A total of 2090 publications were enrolled. The United States contributed the most publications (434, 20.8%), followed by China (345, 16.5%) and England (163, 7.80%). Publications from the United States were cited more frequently (9552 citations) with the highest H-index of 48. China ranked second in the total number of publications, the papers were not cited that frequently (3237 citations), and the H-index ranked sixth (H-index=29). Journal of Cataract and Refractive Surgery published the most papers (333, 15.9%), and the University of London had the highest number of publications (75, 3.59%). Dick HB from Germany published the most papers. Corneal astigmatism-related research, cataract surgery method-related research, postoperative visual-quality relate to research, and postoperative complications-relate research are the hotspots in this field. The most significant limitation was that the database was updated frequently and the latest publications were not included. CONCLUSION The bibliometric analysis shows a brief summarization of the contribution of the authors, institutions, countries, and journals. Corneal astigmatism, cataract surgery method, postoperative visual-quality and postoperative complications related researches have become the emerging hotspots, which can give a direction in the future researches.
Collapse
Affiliation(s)
- Xiao-Yong Chen
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing 100191, China
| | - Qian-Ru Wu
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Capital Medical University, Beijing 100730, China
| | - Min-Yue Xie
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Capital Medical University, Beijing 100730, China
| | - Di Zhang
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing 100191, China
| | - Chun Zhang
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing 100191, China
| |
Collapse
|
4
|
Sahin V, Unal M, Ayaz Y. Outcomes after bilateral implantation of AcrySof IQ PanOptix trifocal intraocular lens: a prospective interventional study. MEDICAL HYPOTHESIS, DISCOVERY & INNOVATION OPHTHALMOLOGY JOURNAL 2023; 12:36-45. [PMID: 37641668 PMCID: PMC10445311 DOI: 10.51329/mehdiophthal1468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 05/26/2023] [Indexed: 08/31/2023]
Abstract
Background Implantation of multifocal intraocular lenses (IOLs) is becoming increasingly popular for the treatment of visual demands at various distances in patients undergoing phacoemulsification cataract surgery. We aimed to assess the visual performance and rates of photic phenomena, posterior capsule opacification (PCO), and spectacle independence in patients with bilateral implantation of the AcrySof® IQ PanOptix® multifocal IOL model TFNT00 at one and six months postoperatively. Methods This prospective interventional cohort study included adult patients who underwent uneventful phacoemulsification cataract surgery with bilateral implantation of AcrySof® IQ PanOptix® IOL. Uncorrected and corrected visual acuities at far, intermediate, and near distances were measured preoperatively and at the one- and six-month postoperative follow-up examinations. The rates of photic phenomena, postoperative need for near and distance spectacles, and PCO were also recorded. Results We included 164 eyes of 82 patients with a male-to-female ratio of 38 (46.3%) to 44 (53.7%) and a mean (standard deviation [SD]) age of 52.37 (7.62) years. There were statistically significant improvements in the visual acuities of both eyes across all distances at the one- and six-month follow-up examinations compared to the preoperative values (all P < 0.001), except for corrected near visual acuity in the right eye (P > 0.05) at six-month. We also detected significant postoperative improvements in visual acuities of both eyes across all distances at the six-month follow-up compared to values at the one-month follow-up (all P < 0.05), except for corrected near visual acuity in the right eye (P > 0.05). The photic phenomenon was reported by 12 (14.6%) of the 82 patients at the six-month postoperative follow-up. Five (6.1%) and eight (9.8%) of the 82 patients reported using spectacles for distance and near, respectively. Additionally, PCO developed in 19 (11.6%) of the 164 included eyes, although it was not clinically significant at six months. Conclusions The AcrySof® IQ PanOptix® IOL model TFNT00 is recommended for use, given its excellent performance in all ranges of vision, a high rate of spectacle independence, and a good safety profile. Future comparative studies with longer follow-up periods are warranted to verify superiority of its performance over that of other available multifocal IOLs.
Collapse
Affiliation(s)
- Vedat Sahin
- Department of Ophtalmology, Faculty of Medicine, Akdeniz University, Antalya, Turkey
| | - Mustafa Unal
- Department of Ophtalmology, Faculty of Medicine, Akdeniz University, Antalya, Turkey
| | - Yusuf Ayaz
- Department of Ophtalmology, Faculty of Medicine, Akdeniz University, Antalya, Turkey
| |
Collapse
|