1
|
Miao Y, Xu M, Yang Z, Gong M, Yang L. The association between left atrial appendage emptying velocity and atrial fibrillation recurrence after radiofrequency catheter ablation in patients with early persistent atrial fibrillation. BMC Cardiovasc Disord 2024; 24:529. [PMID: 39354384 PMCID: PMC11443837 DOI: 10.1186/s12872-024-04215-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 09/19/2024] [Indexed: 10/03/2024] Open
Abstract
OBJECTIVE In the present study, we aimed to explore the association between left atrial appendage emptying velocity (LAAEV) measured by transesophageal echocardiography and atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA) in patients with early persistent atrial fibrillation (PeAF). METHODS We retrospectively analyzed patients with early PeAF who underwent their initial ablation procedure. The echocardiographic and clinical data of the enrolled patients were collected and recorded prior to the operation. Following adjustment for confounding factors, we investigated the relationship between the LAAEV and AF recurrence in patients with early PeAF after radiofrequency ablation. RESULTS The proportions of AF recurrence in the low, medium, and high LAAEV groups were 48.8%, 16.0%, and 13.1%, respectively. After adjusting for potential confounding factors, we observed a gradual decrease in the risk of AF recurrence with increasing LAAEV (odds ratio: 0.882, 95% confidence interval: 0.842-0.924, p<0.001). This trend was statistically significant (p<0.001), particularly when comparing the high and low LAAEV groups (odds ratio: 0.033, 95% confidence interval: 0.009-0.116, p<0.001). Curve fitting analysis demonstrated an approximate negative linear association between LAAEV and the probability of AF recurrence. CONCLUSIONS Among patients with early PeAF who successfully underwent their first RFCA, we found that the LAAEV within 24 h before the procedure was independently correlated with the risk of AF recurrence. Notably, this association was negative, indicating that higher LAAEV was associated with a lower risk of AF recurrence.
Collapse
Affiliation(s)
- Yuxia Miao
- Department of Cardiovascular Disease, Division of Echocardiography, The First People's Hospital of Changzhou, The Third Affiliated Hospital of Soochow University, Chang Zhou City, Jiangsu Province, 213000, China
| | - Min Xu
- Department of Cardiovascular Disease, Division of Echocardiography, The First People's Hospital of Changzhou, The Third Affiliated Hospital of Soochow University, Chang Zhou City, Jiangsu Province, 213000, China.
| | - Zhenni Yang
- Department of Cardiovascular Disease, Division of Echocardiography, The First People's Hospital of Changzhou, The Third Affiliated Hospital of Soochow University, Chang Zhou City, Jiangsu Province, 213000, China
| | - Mingxia Gong
- Department of Cardiovascular Disease, Division of Echocardiography, The First People's Hospital of Changzhou, The Third Affiliated Hospital of Soochow University, Chang Zhou City, Jiangsu Province, 213000, China
| | - Ling Yang
- Department of Cardiovascular Disease, The First People's Hospital of Changzhou, The Third Affiliated Hospital of Soochow University, Chang Zhou City, Jiangsu Province, 213000, China
| |
Collapse
|
2
|
Cui J, Du X, He L, Xia SJ, Tang RB, Sang CH, Long DY, Dong JZ, Ma CS. Impact of pre-ablation left appendage flow velocities on long term recurrence of catheter ablation for paroxysmal atrial fibrillation. Pacing Clin Electrophysiol 2023; 46:1412-1418. [PMID: 37736872 DOI: 10.1111/pace.14828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 07/27/2023] [Accepted: 09/07/2023] [Indexed: 09/23/2023]
Abstract
BACKGROUND Despite undergoing a single ablation, many patients with paroxysmal atrial fibrillation (PAF) experience a gradually increasing recurrence rate. This study aims to examine the relationship between left atrial appendage emptying velocity (LAAeV) and filling velocity (LAAfV) profiles and 3-year recurrence of AF after ablation. METHODS We conducted a prospective study of 658 consecutive PAF patients who underwent their first ablation between January 2018 and December 2019. We collected the clinical and echocardiographic characteristics of the patients. LAAeV and LAAfV were obtained from a transesophageal echocardiogram (TEE) before catheter ablation. Patients were followed at regular intervals to monitor for the primary outcome of AF recurrence. RESULTS After a median follow-up period of 35.3 months (range, 10.7-36.3), 288 patients (43.8%) experienced AF recurrence after catheter ablation. Patients who experienced AF recurrence had decreased LAAeV and LAAfV (LAAeV: 56.5 ± 21.2 vs. 59.6 ± 20.7 cm/s, p = .052; LAAfV: 47.5 ± 17.9 vs. 51.7 ± 18.2, p = .003). Kaplan-Meier analysis showed that patients in the low LAAeV (<55 cm/s) group had a poorer event-free survival rate than those in the high LAAeV (≥55 cm/s) group (log-rank p = .012). Patients with LAAfV <48 cm/s had a significantly higher risk of AF recurrence than those with LAAfV ≥48 cm/s (log-rank p = .003). In the multivariable model, low LAAfV pre-ablation in TEE-guided was significantly independently associated with 3-year recurrence after single radiofrequency ablation in patients with PAF, along with LA dimension and duration of AF. CONCLUSION This study found an independent association between low LAAfV pre-ablation in TEE-guided and 3-year recurrence after single radiofrequency ablation in patients with PAF.
Collapse
Affiliation(s)
- Jing Cui
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Xin Du
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Liu He
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Shi-Jun Xia
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Ri-Bo Tang
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Cai-Hua Sang
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - De-Yong Long
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Jian-Zeng Dong
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Chang-Sheng Ma
- Department of Cardiology, Beijing An Zhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| |
Collapse
|
3
|
Zhao Y, Zhang C, Peng L, Xie Q, Chen C, Yan L, Chen W. Clinical effectiveness and efficiency of a new steerable sheath technology for radiofrequency ablation in Chinese patients with atrial fibrillation: a retrospective comparative cohort study. J Thorac Dis 2023; 15:3953-3964. [PMID: 37559613 PMCID: PMC10407469 DOI: 10.21037/jtd-23-1021] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 07/17/2023] [Indexed: 08/11/2023]
Abstract
BACKGROUND The clinical effectiveness and efficiency of a steerable sheath for radiofrequency catheter ablation (RFCA) in Chinese patients with atrial fibrillation (AF) needs to be compared with a fixed curve sheath to optimize RFCA procedure. METHODS This retrospective study included adult AF patients with their first RFCA that was conducted by the same electrophysiologist using a steerable sheath (VIZIGO, Biosense Webster, Inc.) or a fixed curve sheath (NaviEase, Synaptic Medical) in a Chinese tertiary care hospital from January to November 2021. The medical records kept at the hospital were the source of study data that included patient baseline characteristics and outcome measures for the clinical effectiveness and efficiency of RFCA procedure. Multivariate generalized linear regression analyses were performed to explore the impact of sheath type on clinical effectiveness and efficiency after adjustment. RESULTS Fourteen patients using steerable sheath and 34 patients using fixed curve sheath for RFCA were included in the data analysis. Most of patient baseline characteristics associated with the two study groups were comparable except that the steerable sheath group had significantly higher left atrium diameter (41.9±6.5 vs. 38.1±3.9 mm, P=0.017) and larger left atrium volume (150.4±29.5 vs. 126.8±27.5 mL, P=0.017) than the fixed curve sheath group. Using steerable sheath was associated with significantly shorter total pulmonary vein isolation (PVI) fluoroscopy time and post-surgery hospital length of stay (LOS) than using fixed curve sheath in both unadjusted comparisons (PVI fluoroscopy time: 1.3±1.5 vs. 4.0±3.9 min, P=0.004; post-surgery LOS: 2.1±0.7 vs. 2.9±1.5 days, P=0.034) and multivariate generalized regression analyses (PVI fluoroscopy time: coefficient =-0.859, P=0.014; post-surgery LOS: coefficient =-0.303, P=0.018). CONCLUSIONS Compared to fixed curve sheath, steerable sheath used for RFAC could have the potential to shorten the PVI fluoroscopy time and reduce post-surgery LOS in a Chinese real-world hospital setting. Future real-world studies with large sample size are needed to confirm our study findings.
Collapse
Affiliation(s)
- Yixia Zhao
- Department of Cardiology, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Chenglong Zhang
- Department of Cardiology, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Liming Peng
- Department of Cardiology, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Qiying Xie
- Department of Cardiology, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Chunjia Chen
- Changsha Normin Medical Technology Ltd., Changsha, China
| | - Li Yan
- Changsha Normin Medical Technology Ltd., Changsha, China
| | - Wendong Chen
- Changsha Normin Medical Technology Ltd., Changsha, China
- Normin Health Consulting Ltd., Toronto, Canada
- Toronto Health Economics and Technology Assessment Collaborative, University of Toronto, Toronto, Canada
| |
Collapse
|
4
|
Kiliszek M, Uziębło-Życzkowska B, Krzyżanowski K, Jurek A, Wierzbowski R, Smalc-Stasiak M, Krzesiński P. Value of Left Atrial Strain in Predicting Recurrence after Atrial Fibrillation Ablation. J Clin Med 2023; 12:4034. [PMID: 37373726 DOI: 10.3390/jcm12124034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 05/27/2023] [Accepted: 06/08/2023] [Indexed: 06/29/2023] Open
Abstract
This study tested the relationship between left atrial (LA) function parameters and the results of pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Consecutive patients undergoing PVI for the first time between 2019 and 2021 were included. Patients underwent radiofrequency ablation using contact force catheters and an electroanatomical system. Follow-up consisted of ambulatory visits/televisits and 7-day Holter monitoring (at 6 and 12 months after ablation). On the day of ablation, all patients underwent transesophageal and transthoracic echocardiography with LA strain analysis. The primary endpoint was atrial tachyarrhythmia recurrence during the follow-up period. Of 221 patients, 22 did not meet the echocardiographic quality criteria, leaving 199 patients. The median follow-up period was 12 months, and 12 patients were lost to follow-up. Recurrences were observed in 67 patients (35.8%) after a mean of 1.06 procedures per patient. The patients were divided into a sinus rhythm (SR, n = 109) group and an AF (n = 90) group based on their cardiac rhythm at the time of echocardiography. In the SR group, univariable analysis showed that LA reservoir strain, LA appendage emptying velocity (LAAV), and LA volume index predicted AF recurrence, with only LAAV being significant in the multivariable analysis. In AF patients, univariable analysis revealed no LA strain parameters predicting AF recurrence.
Collapse
Affiliation(s)
- Marek Kiliszek
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| | - Beata Uziębło-Życzkowska
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| | - Krystian Krzyżanowski
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| | - Agnieszka Jurek
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| | - Robert Wierzbowski
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| | - Magdalena Smalc-Stasiak
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| | - Paweł Krzesiński
- Department of Cardiology and Internal Diseases, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland
| |
Collapse
|
5
|
Papathanasiou KA, Vrachatis DA, Kazantzis D, Kossyvakis C, Giotaki SG, Deftereos G, Raisakis K, Kaoukis A, Avramides D, Lambadiari V, Siasos G, Deftereos S. Left atrial appendage morphofunctional indices could be predictive of arrhythmia recurrence post-atrial fibrillation ablation: a meta-analysis. Egypt Heart J 2023; 75:29. [PMID: 37079174 PMCID: PMC10119349 DOI: 10.1186/s43044-023-00356-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 04/14/2023] [Indexed: 04/21/2023] Open
Abstract
BACKGROUND Left atrium changes are implicated in atrial fibrillation (AF) substrate and are predictive of AF outcomes. Left atrial appendage (LAA) is an integral component of left atrial structure and could be affected by atrial cardiomyopathy. We aimed to elucidate the association between LAA indices and late arrhythmia recurrence after atrial fibrillation catheter ablation (AFCA). METHODS The MEDLINE database, ClinicalTrials.gov, medRxiv and Cochrane Library were searched for studies evaluating LAA and late arrhythmia recurrence in patients undergoing AFCA. Data were pooled by meta-analysis using a random-effects model. The primary endpoint was pre-ablation difference in LAA anatomic or functional indices. RESULTS A total of 34 studies were found eligible and five LAA indices were analyzed. LAA ejection fraction and LAA emptying velocity were significantly lower in patients with AF recurrence post-ablation [SMD = - 0.66; 95% CI (- 1.01, - 0.32) and SMD = - 0.56; 95% CI (- 0.73, - 0.40) respectively] as compared to arrhythmia free controls. LAA volume and LAA orifice area were significantly higher in patients with AF recurrence post-ablation (SMD = 0.51; 95% CI 0.35-0.67, and SMD = 0.35; 95% CI 0.20-0.49, respectively) as compared to arrhythmia free controls. LAA morphology was not predictive of AF recurrence post-ablation (chicken wing morphology; OR 1.27; 95% CI 0.79-2.02). Moderate statistical heterogeneity and small case-control studies are the main limitations of our meta-analysis. CONCLUSIONS Our findings suggest that LAA ejection fraction, LAA emptying velocity, LAA orifice area and LAA volume differ between patients suffering from arrhythmia recurrence post-ablation and arrhythmia free counterparts, while LAA morphology is not predictive of AF recurrence.
Collapse
Affiliation(s)
- Konstantinos A Papathanasiou
- Second Department of Cardiology, National and Kapodistrian University of Athens, Medical School, Attikon University Hospital, 1 Rimini Str., Chaidari, Attiki, 12462, Athens, Greece.
| | - Dimitrios A Vrachatis
- Second Department of Cardiology, National and Kapodistrian University of Athens, Medical School, Attikon University Hospital, 1 Rimini Str., Chaidari, Attiki, 12462, Athens, Greece
| | - Dimitrios Kazantzis
- Bristol Eye Hospital, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
| | | | - Sotiria G Giotaki
- Second Department of Cardiology, National and Kapodistrian University of Athens, Medical School, Attikon University Hospital, 1 Rimini Str., Chaidari, Attiki, 12462, Athens, Greece
| | - Gerasimos Deftereos
- Department of Cardiology, "G. Gennimatas" General Hospital of Athens, Athens, Greece
| | - Konstantinos Raisakis
- Department of Cardiology, "G. Gennimatas" General Hospital of Athens, Athens, Greece
| | - Andreas Kaoukis
- Department of Cardiology, "G. Gennimatas" General Hospital of Athens, Athens, Greece
| | - Dimitrios Avramides
- Department of Cardiology, "G. Gennimatas" General Hospital of Athens, Athens, Greece
| | - Vaia Lambadiari
- Second Department of Internal Medicine, National and Kapodistrian University of Athens, Medical School, Attikon University Hospital, 12462, Athens, Greece
| | - Gerasimos Siasos
- 3rd Department of Cardiology, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens, Greece
| | - Spyridon Deftereos
- Second Department of Cardiology, National and Kapodistrian University of Athens, Medical School, Attikon University Hospital, 1 Rimini Str., Chaidari, Attiki, 12462, Athens, Greece
| |
Collapse
|
6
|
Wang L, Zhang Y, Zhou W, Chen J, Li Y, Tang Q, Chen B, Zhang H, Zellmer L, Chen J, Chen Z, Li W, Liu X, Zhou H. Relationship between left atrial appendage peak flow velocity and nonvalvular atrial fibrillation recurrence after cryoablation. Front Cardiovasc Med 2023; 10:1053102. [PMID: 36937924 PMCID: PMC10017530 DOI: 10.3389/fcvm.2023.1053102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 02/13/2023] [Indexed: 03/06/2023] Open
Abstract
Background Previous studies revealed the connection between left atrial appendage peak flow velocity (LAA-PEV) and postoperative persistent atrial fibrillation (AF) recurrence. Yet, this association is not necessarily generalizable to persistent AF patients undergoing initial cryoballoon ablation due to current gaps in the literature. Methods We prospectively studied 74 consecutive individuals with persistent atrial fibrillation undergoing a cryoballoon ablation for the first time between January 2018 and January 2020. Before ablation, LAA-PEV was documented by transesophageal echocardiography (TEE). Subsequently, demographic information and other clinical characteristics of these participants were collected. A 96-h continuous cardiac monitor was reviewed regularly for recurrence of atrial fibrillation. Cox proportional hazards regression was used to investigate LAA-PEV as well as other clinical characteristics as a predictor of AF recurrence. Results Our study found that AF recurrences had lower LAA-PEV than those without AF recurrence. A nonlinear relationship between the LAA-PEV and AF recurrence was observed in this study, which had an inflection point of 34.9. Subgroup analysis of female participants showed that LAA-PEV had a positive correlation with AF recurrence [β = 0.8, 95% CI (0.7, 0.9), p < 0.05]. Conclusion A low LAA-PEV is related to recurrence of atrial fibrillation and may predict AF recurrence after initial cryoballoon ablation for persistent atrial fibrillation. This finding may help improve treatment and care strategies for patients with persistent atrial fibrillation.
Collapse
Affiliation(s)
- Long Wang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Yan Zhang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Wei Zhou
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Jingjing Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Yongkang Li
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Qian Tang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Bingxiu Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Huiling Zhang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Lucas Zellmer
- Department of Internal Medicine, Hennepin County Medical Center, Minneapolis, MN, United States
| | - Jin Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Zhangrong Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Wei Li
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Xingde Liu
- Department of Internal Medicine, School of Clinical Medicine, Guizhou Medical University, Guiyang, Guizhou, China
- *Correspondence: Haiyan Zhou, ; Xingde Liu,
| | - Haiyan Zhou
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
- *Correspondence: Haiyan Zhou, ; Xingde Liu,
| |
Collapse
|
7
|
Han S, Liu M, Jia R, Cen Z, Guo R, Liu G, Cui K. Left atrial appendage function and structure predictors of recurrent atrial fibrillation after catheter ablation: A meta-analysis of observational studies. Front Cardiovasc Med 2022; 9:1009494. [PMCID: PMC9632352 DOI: 10.3389/fcvm.2022.1009494] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 10/04/2022] [Indexed: 11/13/2022] Open
Abstract
Background The results of studies evaluating the left atrial appendage (LAA) function and structure as predictors of atrial fibrillation (AF) recurrence after catheter ablation (CA) are contradictory. Therefore, we performed a meta-analysis to assess whether the LAA function and structure can predict the recurrence of AF after CA. Methods The PubMed, EMBASE, Web of Science, and Cochrane library databases were used to conduct a comprehensive literature search. Finally, 37 studies encompassing 11 LAA parameters were included in this meta-analysis. Results Compared with those in the non-recurrence group, the recurrence group had increased LAA volume (SMD 0.53, 95% CI [0.36, 0.71] p < 0.00001), LAA volume index, LAA orifice area, and LAA orifice short/long axis and decreased LAA emptying flow velocity (SMD -0.54, 95% CI [-0.68, -0.40], P < 0.00001), LAA filling flow velocity, and LAA ejection fraction, while there was no significant difference in LAA morphology or LAA depth. Conclusion Large LAA structure of pre-ablation (LAA volume, orifice area, orifice long/short axis, and volume index) and decreased LAA function of pre-ablation (LAA emptying flow velocity, filling flow velocity, ejection fraction, and LASEC) increase the odds of AF recurrence after CA. Systematic review registration [https://www.crd.york.ac.uk/prospero/], identifier [CRD42022324533].
Collapse
Affiliation(s)
- Shaojie Han
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ming Liu
- Interventional Operating Room, Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ruikun Jia
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Zhifu Cen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ran Guo
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Guobin Liu
- Department of Cardiology, The First People’s Hospital of Jintang County, Chengdu, China
- *Correspondence: Guobin Liu,
| | - Kaijun Cui
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
- *Correspondence: Guobin Liu,
| |
Collapse
|
8
|
Chen P, Shi Y, Ju J, Pan D, Miao L, Guo X, Chen Z, Du J. Left atrial appendage flow velocity predicts recurrence of atrial fibrillation after catheter ablation: A systematic review and meta-analysis. Front Cardiovasc Med 2022; 9:971848. [PMID: 36148065 PMCID: PMC9485569 DOI: 10.3389/fcvm.2022.971848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 08/08/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose There is increasing evidence that left atrial appendage flow velocity (LAAFV) is linked to the recurrence of atrial fibrillation (AF) after catheter ablation (CA), suggesting the potential predictable significance of LAAFV in this setting. We performed a systematic review and meta-analysis to assess whether LAAFV is association with AF recurrence after CA. Methods Up to May 1, 2022, six databases (PubMed, EMBASE, Web of Science, Cochrane Library, Scopus, and CINAHL) were searched for literature reporting the association between LAAFV and AF recurrence after CA. All statistical analyses were carried out using STATA version 16 software. Heterogeneity was determined by the Cochrane’s Q test and I2 statistics. The Newcastle-Ottawa Scale (NOS) was used to assess the methodological quality of each included study, and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) method was adopted to evaluate the quality of evidence. Result Sixteen studies with 5,006 AF patients after CA (1,479 patients with AF recurrence, 3,527 without AF recurrence) were included in the meta-analysis. The meta-analysis of 15 studies (16 data sets) showed that patients with recurrence exhibited lower LAAFV values than those without recurrence [standardized mean difference (SMD): −0.65, 95% CI: −0.88 to −0.42, P < 0.01]. Moreover, we evaluated the association of LAAFV and the risk of AF recurrence after CA. Nine studies (11 data sets) defined LAAFV as continuous variables, and the pooled analysis suggested that for every 1 cm/s rise in LAAFV values, the risk of AF recurrence after CA decreased by 3% [Odds Ratio (OR): 0.97, 95% CI: 0.95 to 0.99, P < 0.01]. Seven studies defined LAAFV as categorical variables, and the pooled analysis showed that lower LAAFV were associated with an increased risk of AF recurrence after CA [OR: 2.28, 95% CI: 1.46 to 3.57, P < 0.01]. The subgroup analyses showed that the association between LAAFV and AF recurrence after CA was not significantly affected by the AF type and ablation procedure. The NOS indicated that included studies were moderate to high quality, while the GRADE assessment suggested a low certainty of the evidence. Conclusion Lower LAAFV may be associated with an increased risk of AF recurrence after CA. Further studies with well designed and randomized studies for LAAFV should be conducted. Systematic review registration [https://www.crd.york.ac.uk/PROSPERO/], identifier [CRD42022333627].
Collapse
Affiliation(s)
- Pengfei Chen
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Yujiao Shi
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Jianqing Ju
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Cardiovascular Diseases Center, Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Deng Pan
- Beijing University of Traditional Chinese Medicine, Beijing, China
| | - Lina Miao
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Beijing University of Traditional Chinese Medicine, Beijing, China
| | - Xiaolin Guo
- Shanxi University of Traditional Chinese Medicine, Taiyuan, China
| | - Zhuhong Chen
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Cardiovascular Diseases Center, Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- *Correspondence: Zhuhong Chen,
| | - Jianpeng Du
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Cardiovascular Diseases Center, Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Jianpeng Du,
| |
Collapse
|