1
|
Fan S, Luo H, Chen S, Xiang H, Mai Q, Zhu Z, Chen Y, Hou Z, Chen W, Zhu Q, Zhang Y. Effect of different lumbar-iliac fixation and sacral slope for Tile C1.3 pelvic fractures: a biomechanical study. J Orthop Traumatol 2024; 25:32. [PMID: 38926180 PMCID: PMC11208344 DOI: 10.1186/s10195-024-00776-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 06/15/2024] [Indexed: 06/28/2024] Open
Abstract
BACKGROUND Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation. The aim of this study is to evaluate the biomechanical effects of different LIF and SS on Tile C1.3 pelvic fracture under two-legged standing load in human cadavers. METHODS Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed. RESULTS The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS. CONCLUSIONS This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.
Collapse
Affiliation(s)
- Shicai Fan
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Hongjie Luo
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Sheqiang Chen
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Haibo Xiang
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Qiguang Mai
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Zhenhua Zhu
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Yuhui Chen
- Department of Traumatic Surgery, Center for Orthopaedic Surgery, Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Zhiyong Hou
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China
| | - Wei Chen
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China
| | - Qingan Zhu
- Division of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
| | - Yingze Zhang
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
| |
Collapse
|
2
|
Meuser AH, Henyš P, Höch A, Gänsslen A, Hammer N. Evaluating the stability of external fixators following pelvic injury: A systematic review of biomechanical testing methods. J Mech Behav Biomed Mater 2024; 153:106488. [PMID: 38437754 DOI: 10.1016/j.jmbbm.2024.106488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 10/31/2023] [Accepted: 02/26/2024] [Indexed: 03/06/2024]
Abstract
INTRODUCTION This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.
Collapse
Affiliation(s)
- Annika Hela Meuser
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | - Petr Henyš
- Institute of New Technologies and Applied Informatics, Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
| | - Andreas Höch
- Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany
| | - Axel Gänsslen
- Clinic for Trauma Surgery, Orthopaedics and Hand Surgery, Wolfsburg Hospital, Wolfsburg, Germany
| | - Niels Hammer
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria; Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany; Division of Biomechatronics, Fraunhofer IWU, Dresden, Germany.
| |
Collapse
|
3
|
Significant improvement in axial load stability with the pre-tensioned pelvic external fixator: A biomechanical analysis in a model with type C Tile lesion. Rev Esp Cir Ortop Traumatol (Engl Ed) 2023; 67:125-133. [PMID: 35985409 DOI: 10.1016/j.recot.2022.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 07/08/2022] [Accepted: 08/11/2022] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE The aim of our work is to check if the use of a pre-tensed bar connected to 2supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. MATERIAL AND METHODS We used synthetic pelvis (N=5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. RESULTS When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint (P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). DISCUSSION The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. CONCLUSIONS The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.
Collapse
|
4
|
Durán Garrido FJ, Pérez de la Blanca A, Lombardo Torre M, Delgado Rufino B, Peña Trabalón A, Queipo de Llano Temboury A. [Translated article] Significant improvement in axial load stability with the pre-tensioned pelvic external fixator: A biomechanical analysis in a model with type C Tile lesion. Rev Esp Cir Ortop Traumatol (Engl Ed) 2023; 67:T125-T133. [PMID: 36528300 DOI: 10.1016/j.recot.2022.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 08/11/2022] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVE The aim of our work is to check if the use of a pre-tensed bar connected to 2 supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. MATERIAL AND METHODS We used synthetic pelvis (N = 5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. RESULTS When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint(P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). DISCUSSION The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. CONCLUSIONS The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.
Collapse
Affiliation(s)
- F J Durán Garrido
- Unidad de Cirugía Ortopédica y Traumatología, Hospital Universitario Virgen de La Victoria, Málaga, Spain.
| | | | - M Lombardo Torre
- Unidad de Cirugía Ortopédica y Traumatología, Hospital Universitario Virgen de La Victoria, Málaga, Spain
| | - B Delgado Rufino
- Unidad de Cirugía Ortopédica y Traumatología, Hospital Universitario Virgen de La Victoria, Málaga, Spain
| | - A Peña Trabalón
- Escuela de Ingenierías industriales, Universidad de Málaga, Málaga, Spain
| | - A Queipo de Llano Temboury
- Unidad de Cirugía Ortopédica y Traumatología, Hospital Universitario Virgen de La Victoria, Málaga, Spain
| |
Collapse
|
5
|
Percutaneous screw fixation of the pubic symphysis versus plate osteosynthesis: a biomechanical study. OTA Int 2022; 5:e215. [PMID: 36569108 PMCID: PMC9782317 DOI: 10.1097/oi9.0000000000000215] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 05/28/2022] [Indexed: 12/27/2022]
Abstract
Objectives: To compare the stability of screw fixation with that of plate fixation for symphyseal injuries in a vertically unstable pelvic injury (AO/Tile 61-C1) associated with complete disruption of the sacroiliac joint and the pubic symphysis. Methods: Eight fourth-generation composite pelvis models with sacroiliac and pubic symphyseal disruption (Sawbones, Vashon Island, WA) underwent biomechanical testing simulating static single-leg stance. Four were fixed anteriorly with a symphyseal screw, and 4 with a symphyseal plate. All had single transsacral screw fixation posteriorly. Displacement and rotation were monitored at both sacroiliac joint and pubic symphysis. Results: There was no significant difference between the 2 groups for mean maximum force generated. There was no significant difference in net displacement at both sacroiliac joint and pubic symphysis. There was significantly less rotation but more displacement in the screw group in the Z-axis. The screw group showed increased stiffness compared with the plate group. Conclusions: This is the first biomechanical study to compare screw versus plate symphyseal fixation in a Tile C model. Our biomechanical model using anterior and posterior fixation demonstrates that symphyseal screws may be a viable alternative to classically described symphyseal plating.
Collapse
|
6
|
Beneš J, Kunz L, Liška J, Šrám J, Krbec M, Džupa V, Křivohlávek M, Návrat T. Determination of stress and displacement on human composite pelvis under static and dynamic loading. Proc Inst Mech Eng H 2022; 236:951-959. [DOI: 10.1177/09544119221099805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This case study describes the experimental determination of displacements and stresses on a composite model of a pelvis that was modified to represent a healthy intact pelvic ring. The modified model was stressed statically up to 1750 N to simulate standing on one leg and also cyclically to model walking. For two different model settings in the loading machine the values of displacements and stresses at the pelvic ring were determined. The two different settings correspond to two different loading vectors applied on the pelvic ring, boundary conditions and degrees of freedom. The experimentally determined values of displacements in both settings are very similar and in accordance with the knowledge on the behaviour of a real human pelvis. The modified model is thus suitable for testing of newly developed implants for pelvis treatment and experimental determination of displacements and stresses in pelvic ring which are caused by application of implants.
Collapse
Affiliation(s)
- Jan Beneš
- BT Medical Engineering, Inc., Rozsochy, Czech Republic
| | - Ludvík Kunz
- Institute of Physics of Materials, Czech Academy of Sciences, Brno, Czech Republic
| | | | | | - Martin Krbec
- Department of Orthopaedics and Traumatology, Third Faculty of Medicine of Charles University and University Hospital Kralovske Vinohrady, Prague, Czech Republic
| | - Valér Džupa
- Department of Orthopaedics and Traumatology, Third Faculty of Medicine of Charles University and University Hospital Kralovske Vinohrady, Prague, Czech Republic
| | | | - Tomáš Návrat
- Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic
| |
Collapse
|
7
|
Zheng YQ, Chen LL, Shen JZ, Gao B, Huang XC. Biomechanical evaluation of seven fixation methods to treat pubic symphysis diastasis using finite element analysis. J Orthop Surg Res 2022; 17:189. [PMID: 35346277 PMCID: PMC8961909 DOI: 10.1186/s13018-022-03078-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 03/16/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Pubic symphysis diastasis (PSD) hinders the connection between bilateral ischia and pubic bones, resulting in instability of the anterior pelvic ring. PSD exceeding 25 mm is considered disruptions of the symphyseal and unilateral/bilateral anterior sacroiliac ligaments and require surgical intervention. The correct choice of fixation devices is of great significance to treat PSD. This study aimed to evaluate the construct stability and implant performance of seven fixation methods to treat PSD using finite element analysis.
Methods
The intact skeleton-ligament pelvic models were set as the control group. PSD models were simulated by removing relevant ligaments. To enhance the stability of the posterior pelvic ring, a cannulated screw was applied in the PSD models. Next, seven anterior fixation devices were installed on the PSD models according to standard surgical procedures, including single plates (single-Plate group), single plates with trans-symphyseal cross-screws (single-crsPlate group), dual plates (dual-Plate group), single cannulated screws, dual crossed cannulated screws (dual-canScrew group), subcutaneous plates (sub-Plate group), and subcutaneous pedicle screw-rod devices (sub-PedRod group). Compression and torsion were applied to all models. The construct stiffness, symphyseal relative micromotions, and von Mises stress performance were recorded and analyzed.
Results
The construct stiffness decreased dramatically under PSD conditions. The dual-canScrew (154.3 ± 9.3 N/mm), sub-Plate (147.1 ± 10.2 N/mm), and sub-PedRod (133.8 ± 8.0 N/mm) groups showed better ability to restore intact stability than the other groups (p < 0.05). Regarding regional stability, only single-plate fixation provided unexpected regional stability with a diastasis of 2.1 ± 0.2 mm (p < 0.001) under a compressive load. Under a rotational load, the single-crsPlate group provided better regional angular stability (0.31° ± 0.03°, p < 0.001). Stress concentrations occurred in the single-Plate, sub-Plate, and sub-PedRod groups. The maximum von Mises stress was observed in the single-plate group (1112.1 ± 112.7 MPa, p < 0.001).
Conclusion
The dual-canScrew fixation device offers ideal outcomes to maintain stability and prevent failure biomechanically. The single-crsPlate and dual-Plate methods effectively improved single-Plate device to enhance regional stability and disperse stresses. The subcutaneous fixation devices provided both anterior pelvic ring stability and pubic symphysis strength.
Collapse
|
8
|
Jordan MC, Jäckle V, Scheidt S, Gilbert F, Hölscher-Doht S, Ergün S, Meffert RH, Heintel TM. Trans-obturator cable fixation of open book pelvic injuries. Sci Rep 2021; 11:13463. [PMID: 34188088 PMCID: PMC8241833 DOI: 10.1038/s41598-021-92755-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 06/15/2021] [Indexed: 01/13/2023] Open
Abstract
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
Collapse
Affiliation(s)
- Martin C Jordan
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
| | - Veronika Jäckle
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Sebastian Scheidt
- Department of Orthopaedic Surgery, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Fabian Gilbert
- Department of Orthopedics, Physical Medicine and Rehabilitation, University Hospital LMU München, Marchioninistr. 15, 81377, München, Germany
| | - Stefanie Hölscher-Doht
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Süleyman Ergün
- Institute of Anatomy, Julius-Maximilians-University Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany
| | - Rainer H Meffert
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Timo M Heintel
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| |
Collapse
|
9
|
Barrientos-Mendoza C, Brañes J, Wulf R, Kremer A, Barahona M, León S. The role of anterior supra-acetabular external fixator as definitive treatment for anterior ring fixation in unstable pelvic fractures. Eur J Trauma Emerg Surg 2021; 48:3737-3746. [PMID: 34097076 DOI: 10.1007/s00068-021-01711-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 05/25/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Management of anterior ring injuries is still a matter of discussion, and there are only few studies reporting anterior external fixator as definitive treatment for unstable pelvic injuries. This study aimed to describe the clinical and radiological outcomes of a consecutive series of mechanically unstable pelvic injuries that were treated with definitive anterior supra-acetabular external fixator for the anterior ring, and to identify risk factors for failure. METHODS We included a consecutive series of patients with unstable pelvic ring fractures who underwent anterior supra-acetabular external fixation for definitive treatment, between January 2012 and January 2020. All demographics, associated injuries and procedures, injury mechanism, and complications were analysed. Pelvic fracture was classified based on Orthopaedic Trauma Association/Tile AO (OTA/AO) and Young-Burgess classifications. Complications associated with the external fixator were revised. All patients were functionally evaluated at final follow-up and asked to report their clinical outcomes using the Majeed score. RESULTS A total of 47 patients were included, of which 25 were females. The median age was 44 years (interquartile range 23-59). Median follow-up duration was 14 months (interquartile range 6-31). The most frequent aetiology was motor vehicle accident (35), followed by fall from height (8). All fractures required posterior pelvic ring fixation. The median time during which patients had external fixation in situ was 11 weeks (interquartile range 9-13). All patients achieved healing of pelvic fracture at median time of 10 weeks (interquartile range 8-12). At final follow-up, the median displacement of the anterior pelvis was 6 mm (interquartile range 0-11). Superficial infection was the most common complication (n = 7). No washout procedures were needed. No major complication was reported. No patient required reoperation for anterior ring fracture. The median Majeed score was 88 points (range 60-95; interquartile range 80-90) at final follow-up. CONCLUSION Our findings suggest that the use of supra-acetabular external fixator is safe and effective for definitive treatment of the anterior ring in unstable pelvic fractures. It is a method with high proportion of excellent results, regardless of the type of fracture. The rate of complications is low, and it does not compromise functional results.
Collapse
Affiliation(s)
- Cristián Barrientos-Mendoza
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile. .,Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile. .,Orthopaedics Department, Hip and Pelvis Unit, Clínica Santa María, Santiago, Chile.
| | - Julián Brañes
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile.,Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| | - Rodrigo Wulf
- Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| | - Alex Kremer
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile
| | - Maximiliano Barahona
- Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| | - Sebastián León
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile.,Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| |
Collapse
|
10
|
Jordan MC, Jäckle V, Scheidt S, Eden L, Gilbert F, Heintel TM, Jansen H, Meffert RH. [Outcome after plate stabilization of symphyseal diastasis]. Unfallchirurg 2020; 123:870-878. [PMID: 32347368 PMCID: PMC7653790 DOI: 10.1007/s00113-020-00804-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Hintergrund Die Symphysensprengung mit entsprechender Diastase kann durch eine Symphysenplatte stabilisiert werden. Fragestellung Welche Beckenverletzungen werden mit einer Symphysenplatte stabilisiert und wie ist das Outcome? Material und Methoden Retrospektive Auswertung von 64 Patienten über einen Untersuchungszeitraum von 24 Monaten. Ergebnisse Es waren 56 Patienten männlich, 8 weiblich und das mittlere Alter betrug 44 Jahre (SD ± 17). Unfälle im Straßenverkehr waren der führende Grund für die Beckenverletzung. Die Verteilung nach AO-Klassifikation zeigte sich wie folgt: 14-mal B1-, 10-mal B2-, 5‑mal B3-, 23-mal C1-, 9‑mal C2- und 3‑mal C3-Verletzungen. Die Verteilung nach Young und Burgess ergab: 9‑mal APC-I-, 18-mal APC-II-, 13-mal APC-III-, 9‑mal LC-I-, 3‑mal LC-II-, 2‑mal LC-III- und 10-mal VS-Verletzungen. Der mittlere Injury Severity Score (ISS) betrug 32 und die mittlere stationäre Verweildauer 29 Tage (pos. Korrelation p ≤ 0,001). Im Verlauf war eine radiologische Implantatlockerung bei 52 Patienten nachweisbar. Therapierelevante Komplikationen gab es in 14 Fällen. Hierbei war das Implantatversagen (n = 8) der Hauptgrund für eine operative Revision. Diskussion Obwohl die radiologische Implantatlockerung häufig beobachtet wird, ist sie nur selten Grund für einen Revisionseingriff. Kommt es hingegen zum vollständigen Implantatversagen, tritt dies meist innerhalb der ersten postoperativen Wochen auf und ist revisionsbedürftig. Eine frühzeitige Abklärung durch Röntgenbildgebung sollte bei Verdacht erfolgen.
Collapse
Affiliation(s)
- Martin C Jordan
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland.
| | - Veronika Jäckle
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Sebastian Scheidt
- Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn, Venusberg-Campus 1, 53127, Bonn, Deutschland
| | - Lars Eden
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Fabian Gilbert
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Timo M Heintel
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Hendrik Jansen
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Rainer H Meffert
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| |
Collapse
|
11
|
Zhao Y, Ma Y, Zou D, Sun X, Cheng G, Lian W, Dong S, Zhao Y, Qu W, Wu H. Biomechanical comparison of three minimally invasive fixations for unilateral pubic rami fractures. BMC Musculoskelet Disord 2020; 21:594. [PMID: 32887595 PMCID: PMC7487546 DOI: 10.1186/s12891-020-03604-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 08/20/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To compare the mechanical characteristics of a percutaneous superior pubic intramedullary screw, percutaneous bridging plate and percutaneous screw-rod system of the anterior ring for the treatment of unilateral vertical pubic fractures to provide a reference for clinical application. METHODS A finite element model of pelvic anterior ring injury (unilateral vertical pubic fracture) was produced. The fractures were fixed with a percutaneous superior pubic intramedullary screw, percutaneous bridging plate and percutaneous screw-rod system of the anterior ring and their combinations in 5 types of models. The fracture stabilities under vertical, bilateral and anterior-posterior load were quantified and compared based on the displacement of the hip joints' midpoint as quantificational index of fracture stability. RESULTS In the condition of bilateral and anterior-posterior load, the vertical, bilateral and anterior-posterior displacements of the hip joints' midpoint of different models were significantly different respectively. In general, the displacements of the 5 pelvic anterior ring fixations were ranked from maximum to minimum as follows: bridging plate, pelvic anterior screw-rod system, combination of bridging plate and pelvic anterior screw-rod system, superior pubic intramedullary screw and combination of superior pubic intramedullary screw and pelvic anterior screw-rod system. CONCLUSION For the fixation in unilateral pubic fractures of pelvic ring injury, the percutaneous superior pubic intramedullary screw is optimal, the percutaneous pelvic anterior screw-rod system is the second choice, and percutaneous bridging plate ranks the third. The percutaneous pelvic anterior screw-rod system can significantly increase fixation stability of the percutaneous superior pubic intramedullary screw and the percutaneous bridging plate.
Collapse
Affiliation(s)
- Yong Zhao
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China.
| | - Yupeng Ma
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Dexin Zou
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Xiujiang Sun
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Gong Cheng
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Wei Lian
- CT/MR Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Shengjie Dong
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Yuchi Zhao
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Wenqing Qu
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| | - Hao Wu
- Orthopaedics Department, Yantai Shan Hospital, 91#, Jiefang Road, Yantai, 264008, Shandong Province, People's Republic of China
| |
Collapse
|