Femoral Head Penetration Rates and Oxidation of Highly Crosslinked Polyethylene Hip Liners Implanted More Than 10 Years. J Arthroplasty 2024:S0883-5403(24)00457-1. [PMID: 38754708 DOI: 10.1016/j.arth.2024.05.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 05/06/2024] [Accepted: 05/08/2024] [Indexed: 05/18/2024] Open
Abstract
INTRODUCTION Highly cross-linked and thermally stabilized polyethylene (HXLPE) was introduced to improve wear in total hip arthroplasty (THA), with manufacturers implementing different thermal treatments to reduce oxidation. It is important to understand how long-term time in vivo affects the wear of these materials. The purpose of this study was to investigate the wear and oxidative performance of first-generation HXLPE hip inserts implanted for greater than 10 years and compare annealed and remelted HXLPE formulations. METHODS There were 49 THA liners retrieved during routine revision surgery as part of an IRB approved implant retrieval program. Penetration rates for the liners were calculated as the difference between the thickness of the unloaded and loaded regions divided by implantation time. Oxidation indices for the rim, locking mechanism, articulating surface, and backside regions were measured using Fourier-transform infrared spectroscopy according to ASTM 2102. Mann-Whitney U Tests were used to determine the statistical difference between annealed and remelted components. RESULTS The cohort had an average implantation time of 13.1 ± 2.6 years for annealed and 12.1 ± 1.7 years for remelted components. The components were revised most often for polyethylene wear, instability, and loosening. The penetration rate averaged 0.0177 ± 0.014 mm/year for annealed components and 0.015 ± 0.022 mm/year for remelted components. Penetration rates did not differ between the remelted and annealed cohorts (P = 0.28). Oxidation indices were found to be significantly higher in the annealed cohort for all regions of interest (P < 0.001). CONCLUSION Oxidation was found to be higher in the annealed HXLPE; however, this does not seem to be associated with greater wear, as we found the average penetration rate for the cohort was low, and the penetration rates were similar between the annealed and remelted cohorts.
Collapse
|
2
|
The Measurement of the Oxidative Index of Polyethylene Obtained during Revision Hip Arthroplasty and Assessment of Its Variability Depending on the Degree of Osteolysis, Implantation Time, as Well as the Size and Material of the Utilized Head. J Clin Med 2024; 13:2751. [PMID: 38792292 PMCID: PMC11122221 DOI: 10.3390/jcm13102751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 04/23/2024] [Accepted: 05/03/2024] [Indexed: 05/26/2024] Open
Abstract
Background/Objectives: Aseptic loosening is the leading cause of late revision in total hip arthroplasty, primarily due to degenerative oxidation of polyethylene components, leading to wear particle formation and periacetabular osteolysis. This study aimed to analyze the oxidation levels in polyethylene liners and cemented cups retrieved from revision surgeries using Fourier-transform infrared spectroscopy (FTIR) and to explore the correlation between oxidation levels and factors such as head size, head material, fixation method, and implant survival time. Methods: Polyethylene liners and cups were analyzed post-revision surgery to assess oxidation levels, which were then compared to periacetabular bone loss measured by the Paprosky classification. This study evaluated the impact of head size (28 mm vs. 32 mm), head material (ceramic vs. metal), and fixation methods on oxidation. The relationship between the mean oxidation index (OI) and implant survival time was also investigated. Results: There was a significant positive correlation between the mean oxidation index of the polyethylene components and the severity of periacetabular osteolysis according to the Paprosky scale. While the mean OI for samples articulating with ceramic heads was lower than for those with metal heads, and the mean OI for samples with a 32 mm head size was lower than for those with a 28 mm size, these differences were not statistically significant. Furthermore, the fixation method did not affect the oxidation index, and no correlation was found between OI and the survival time of the implants. Conclusions: This study confirms a direct correlation between polyethylene oxidation and periacetabular osteolysis in hip replacements, highlighting the importance of material choice and design in potentially reducing the risk of aseptic loosening. Despite the lack of significant differences in oxidation levels based on head material and size, these factors may still play a role in the long-term outcome of hip arthroplasty, warranting further investigation.
Collapse
|
3
|
Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review. Sci Rep 2023; 13:15612. [PMID: 37730762 PMCID: PMC10511625 DOI: 10.1038/s41598-023-42809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m2), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m2. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Collapse
|
4
|
Oxidation in Retrieved, Never-Irradiated UHMWPE Bearings: What Can We Learn About in Vivo Oxidation? J Bone Joint Surg Am 2023; 105:293-301. [PMID: 36730084 DOI: 10.2106/jbjs.22.00571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Published analyses of never-irradiated, ethylene oxide (EtO)-sterilized tibial inserts and EtO- and gas plasma (GP)-sterilized acetabular ultra-high molecular weight polyethylene (UHMWPE) retrievals demonstrated minimal UHMWPE in vivo oxidation, whereas another analysis of EtO-sterilized acetabular liners found elevated oxidation linked with in vivo stresses. This study explored whether never-irradiated UHMWPE bearings are (1) oxidized by the in vivo environment, and (2) more likely to oxidize in higher-stress articulations (knee, ankle, shoulder). METHODS An institutional review board-approved retrieval archive was queried for never-irradiated, EtO- and GP-sterilized UHMWPE bearings received at revision from 2001 to 2021. A total of 193 EtO-sterilized and 112 GP-sterilized conventional UHMWPE retrievals were analyzed (0 to 25 years in vivo; 133 hip, 144 knee, 18 ankle, and 10 shoulder). Retrieved implants were evaluated for in vivo damage and analyzed for trans-vinylene and ketone content by Fourier transform infrared spectroscopy (FTIR). Twelve never-implanted EtO-sterilized tibial knee inserts, (shelf-aged 5 to 19 years) were non-oxidized controls. Mechanical properties of 3 never-implanted and 3 retrieved tibial inserts were evaluated by ASTM Type-V uniaxial tensile testing. Statistical analyses evaluated correlations between time in vivo and oxidation, and compared mean oxidation rates by articulation. RESULTS Burnishing was the most common clinical damage for all articulations. Eight retrievals exhibited oxidation-related fatigue damage. All retrievals were validated as never-irradiated (median trans-vinylene index [TVI] = 0.000). Maximum ketone oxidation in retrievals correlated with in vivo time (p < 0.001). Thirty-seven percent of retrievals exhibited UHMWPE (subsurface) oxidation, most frequently ankle, knee, and glenoid inserts. Tensile properties differed between retrieved and never-implanted inserts, changing with oxidation. The oxidation rate differed significantly among the articulations (p < 0.001). CONCLUSIONS This study cohort confirmed the presence of in vivo oxidation in some non-irradiation-sterilized UHMWPE bearings, with higher-stress articulations (knee, ankle, shoulder) showing evidence of oxidation more frequently and having significantly higher oxidation rates than hips. Mechanical properties degraded by oxidation led to fatigue damage in 8 retrievals after a long duration in vivo. CLINICAL RELEVANCE Conventional EtO- or GP-sterilized UHMWPE bearings are at minimal risk for fatigue damage secondary to oxidation. However, higher stresses and longer time in vivo (more cycles of use) can lead to increased wear, oxidation, and fatigue damage.
Collapse
|
5
|
European Database of Explanted UHMWPE Liners from Total Joint Replacements: Correlations among Polymer Modifications, Structure, Oxidation, Mechanical Properties and Lifetime In Vivo. Polymers (Basel) 2023; 15:polym15030568. [PMID: 36771869 PMCID: PMC9921464 DOI: 10.3390/polym15030568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/15/2023] [Accepted: 01/19/2023] [Indexed: 01/24/2023] Open
Abstract
This contribution lays the foundation for the European database of explanted UHMWPE liners from total joint replacements. Three EU countries (Czech Republic, Italy and Spain) have joined their datasets containing anonymized patient data (such as age and BMI), manufacturer data (such as information on UHMWPE crosslinking, thermal treatment and sterilization), orthopedic evaluation (such as total duration of the implant in vivo and reasons for its revision) and material characterization (such as oxidative degradation and micromechanical properties). The joined database contains more than 500 entries, exhibiting gradual growth, and it is beginning to show interesting trends, which are discussed in our contribution, including (i) strong correlations between UHMWPE oxidative degradation, degree of crystallinity and microhardness; (ii) statistically significant differences between UHMWPE liners with different types of sterilization; (iii) realistic correlations between the extent of oxidative degradation and the observed reasons for total joint replacement failures. Our final objective and task for the future is to continuously expand the database, involving researchers from other European countries, in order to create a robust tool that will contribute to the better understanding of structure-properties-performance relationships in the field of arthroplasty implants.
Collapse
|
6
|
Influence of Accelerated Aging on the Wear Behavior of Cross-Linked Polyethylene Liners—A Hip Simulator Study. J Clin Med 2022; 11:jcm11154487. [PMID: 35956104 PMCID: PMC9369584 DOI: 10.3390/jcm11154487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 07/18/2022] [Accepted: 07/27/2022] [Indexed: 02/04/2023] Open
Abstract
Sequential cross-linked and annealed ultra-high-molecular-weight polyethylene (SX-PE) is known as a low-wear articulating partner, especially for total hip endoprostheses. Aging of polymeric materials, irrespective of if induced by shelf or in vivo life, can degrade their tribological and mechanical properties. However, changes in wear behavior of aged SX-PE liners have not been not quantified so far. An accelerated aging procedure, to simulate shelf and in vivo aging, was performed on thin SX-PE liners after five million load cycles using a simulator (“worn-aged”) as well as on new SX-PE liners (“new-aged”). A subsequent hip simulator test was performed with both thin SX-PE liner sets in combination with large-diameter ceramic femoral head, representing a combination known as advantageous for treatment after revision because of dislocation. Oxidation indices were measured on the liners after each step of the procedure. SX-PE liners after accelerated aging show bedding-in phases during simulator test, which was a characteristic only known from clinical investigations. Hence, the wear rates of the “new-aged” ((1.71 ± 0.49) mg/million cycles) and of the “worn-aged” ((9.32 ± 0.09) mg/million cycles) SX-PE were increased in the first period compared to new unaged SX-PE liners. Subsequently, the wear rates decreased for “new-aged” and “worn-aged” inserts to (0.44 ± 0.48) mg/million cycles and (2.72 ± 0.05) mg/million cycles, respectively. In conclusion, the results show promising effects of accelerated aging on SX-PE liners in simulator testing and for potential long-term use in clinical applications.
Collapse
|
7
|
Abstract
The optimal management of the patella during total knee arthroplasty (TKA) remains controversial and surgeons tend to approach the patella with one of three general mindsets: always resurface the patella, never resurface the patella, or selectively resurface the patella based on specific patient or patellar criteria. Studies comparing resurfacing and non-resurfacing of the patella during TKA have reported inconsistent and contradictory findings. When resurfacing the patella is chosen, there are a number of available patellar component designs, materials, and techniques for cutting and fixation. When patellar non-resurfacing is chosen, several alternatives are available, including patellar denervation, lateral retinacular release, and patelloplasty. Surgeons may choose to perform any of these alone, or together in some combination. Prospective randomized studies are needed to better understand which patellar management techniques contribute to superior postoperative outcomes. Until then, this remains a controversial topic, and options for patellar management will need to be weighed on an individual basis per patient.
Cite this article: EFORT Open Rev 2021;6:861-871. DOI: 10.1302/2058-5241.6.200156
Collapse
|
8
|
In vitro evaluation of delamination resistance of PEEK and CFR-PEEK. Proc Inst Mech Eng H 2021; 236:279-285. [PMID: 34431397 DOI: 10.1177/09544119211042992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Poly-ether-ether-ketone (PEEK) and carbon fiber reinforced PEEK as orthopedic implant materials exhibit excellent material properties. Although delamination of PEEK materials has been reported in knee joint wear research, the delamination resistance behavior remains unclear. In this study, the delamination resistance of PEEK materials was investigated; these materials were compared to ultra-high molecular weight polyethylene (UHMWPE). The results of a ball-on-flat type delamination test indicated that the PEEK materials underwent delamination considerably earlier than UHMWPE, and the contact area of the PEEK materials was smaller than that of UHMWPE. Moreover, the indentation modulus, hardness, and coefficient of friction were higher for PEEK materials than for UHMWPE. The reduced tendency of PEEK materials to undergo deformation to mitigate stress concentration at low conformity contact conditions contributed to their inferior delamination resistance compared to that of UHMWPE. The delamination resistance of the PEEK materials was equivalent to that of degraded UHMWPE, which highlights the risk of delamination of PEEK implants in a clinical context. Consequently, when using PEEK materials as an implant component loaded at a low conformity contact condition, the material selection and component design must be carefully considered. Overall, the results of this study can help guide the future development of PEEK-based implants.
Collapse
|
9
|
Highly cross‐linked polyethylene is the new ‘gold standard’ bearing material for total hip arthroplasty. BIOSURFACE AND BIOTRIBOLOGY 2021. [DOI: 10.1049/bsb2.12007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
|
10
|
|
11
|
Sterilization and disinfection methods for decellularized matrix materials: Review, consideration and proposal. Bioact Mater 2021; 6:2927-2945. [PMID: 33732964 PMCID: PMC7930362 DOI: 10.1016/j.bioactmat.2021.02.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 02/08/2021] [Accepted: 02/11/2021] [Indexed: 02/08/2023] Open
Abstract
Sterilization is the process of killing all microorganisms, while disinfection is the process of killing or removing all kinds of pathogenic microorganisms except bacterial spores. Biomaterials involved in cell experiments, animal experiments, and clinical applications need to be in the aseptic state, but their physical and chemical properties as well as biological activities can be affected by sterilization or disinfection. Decellularized matrix (dECM) is the low immunogenicity material obtained by removing cells from tissues, which retains many inherent components in tissues such as proteins and proteoglycans. But there are few studies concerning the effects of sterilization or disinfection on dECM, and the systematic introduction of sterilization or disinfection for dECM is even less. Therefore, this review systematically introduces and analyzes the mechanism, advantages, disadvantages, and applications of various sterilization and disinfection methods, discusses the factors influencing the selection of sterilization and disinfection methods, summarizes the sterilization and disinfection methods for various common dECM, and finally proposes a graphical route for selecting an appropriate sterilization or disinfection method for dECM and a technical route for validating the selected method, so as to provide the reference and basis for choosing more appropriate sterilization or disinfection methods of various dECM. Asepsis is the prerequisite for the experiment and application of biomaterials. Sterilization or disinfection affects physic-chemical properties of biomaterials. Mechanism, advantages and disadvantages of sterilization or disinfection methods. Factors influencing the selection of sterilization or disinfection methods. Selection of sterilization or disinfection methods for decellularized matrix.
Collapse
|
12
|
Probing the Influence of γ-Sterilization on the Oxidation, Crystallization, Sliding Wear Resistance, and Cytocompatibility of Chemically Modified Graphene-Oxide-Reinforced HDPE/UHMWPE Nanocomposites and Wear Debris. ACS Biomater Sci Eng 2020; 6:1462-1475. [PMID: 33455381 DOI: 10.1021/acsbiomaterials.9b01327] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Osteolysis and aseptic loosening due to wear at the articulating interfaces of prosthetic joints are considered to be the key concerns for implant failure in load-bearing orthopedic applications. In an effort to reduce the wear and processing difficulties of ultrahigh-molecular-weight polyethylene (UHMWPE), our research group recently developed high-density polyethylene (HDPE)/UHMWPE nanocomposites with chemically modified graphene oxide (mGO). Considering the importance of sterilization, this work explores the influence of γ-ray dosage of 25 kGy on the clinically relevant performance-limiting properties of these newly developed hybrid nanocomposites in vitro. Importantly, this work also probes into the cytotoxic effects of the wear debris of different compositions and sizes on MC3T3 murine osteoblasts and human mesenchymal stem cells (hMSCs). In particular, γ-ray-sterilized 1 wt % mGO-reinforced HDPE/UHMWPE nanocomposites exhibit an improvement in the oxidation index (16%), free energy of immersion (-12.1 mN/m), surface polarity (5.0%), and hardness (42%). Consequently, such enhancements result in better tribological properties, especially coefficient of friction (+13%) and wear resistance, when compared with UHMWPE. A spectrum of analyses using transmission electron microscopy (TEM) and in vitro cytocompatibility assessment demonstrate that phagocytosable (0.5-4.5 μm) sterilized 1 mGO wear particles, when present in culture media at 5 mg/mL concentration, induce neither significant reduction in MC3T3 murine osteoblast and hMSC growth nor cell morphology phenotype, during 24, 48, and 72 h of incubation. Taken together, this study suggests that γ-ray-sterilized HDPE/UHMWPE/mGO nanocomposites can be utilized as promising articulating surfaces for total joint replacements.
Collapse
|
13
|
Long-Term Implant Survivorship and Modes of Failure in Simultaneous Concurrent Bilateral Total Knee Arthroplasty. J Arthroplasty 2020; 35:139-144. [PMID: 31500911 PMCID: PMC6910974 DOI: 10.1016/j.arth.2019.08.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 07/21/2019] [Accepted: 08/04/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND There is limited evidence describing long-term implant survivorship and modes of failure in simultaneous concurrent bilateral total knee arthroplasty (TKA). METHODS We performed a retrospective review of 266 consecutive patients (532 knees) who underwent simultaneous concurrent bilateral TKA. We reviewed medical records for preoperative characteristics, perioperative complications, and revision surgeries. The primary outcome was TKA survivorship. Secondary outcomes included indication and type of revision surgery. We used the Kaplan-Meier method to estimate survivorship and characterize risk of revision up to 20 years post-TKA. RESULTS Our cohort had median follow-up of 9.8 years (interquartile range, 3.9-15.9). Forty-four patients (17%) underwent revision. Revision was more common among younger and male patients. The cumulative incidence of first-time revision per knee (n = 532) was 1.27 per 100 component-years. Implant survival was 99% (confidence interval, 97%-99%) at 5 years, 92% (89%-95%) at 10 years, 83% (77%-87%) at 15 years, and 62% (50%-73%) at 20 years. Five and 10-year survivorship compared favorably to estimates of TKA survivorship in the literature. The cumulative incidence of revision surgery per patient was 1.91 per 100 component-years. Implant survival at 5-, 10-, 15-, and 20-year time points was 96% (CI, 92%-98%), 84% (77%-89%), 71% (62%-79%), and 59% (46%-70%), respectively. Aseptic loosening (40%), polyethylene wear (34%), and infection (11%) were the most common indications for revision. CONCLUSION Simultaneous concurrent bilateral TKA is associated with a higher risk of reoperation for the patient when both knees are evaluated but similar implant survivorship to the literature when each knee was evaluated in isolation.
Collapse
|
14
|
|
15
|
|
16
|
Genesis 1 posterior cruciate-retaining total knee arthroplasty with asymmetric tibial tray: An 18-to-26-year long-term clinical outcome study. Knee 2019; 26:838-846. [PMID: 31118135 DOI: 10.1016/j.knee.2019.04.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 02/10/2019] [Accepted: 04/16/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND To present the long-term clinical and radiological outcomes of the Genesis I posterior cruciate-retaining total knee arthroplasty (TKA) (Smith & Nephew Orthopaedics, Memphis, TN, USA) (one of the first designed with an asymmetric tibial tray). METHODS Prospectively collected data from 117 cemented TKAs performed on 95 patients were evaluated using this design, with a mean follow-up of 21.5 years (range, 18-26). Failures, complication rates, and clinical (both subjective and objective) and radiological outcomes were assessed for all patients. RESULTS Seven failures occurred (wear and structural failure of the polyethylene insert) and six revision surgeries were performed at a mean of 10 years (range, three to 14) from the index operation. No revision of either the femoral or tibial components for aseptic loosening was performed. Survivorship analysis showed a cumulative success rate of 93.53% (95% CI, 92.75-94.32%) at 20 and 25 years, with revision for any reason as an end point. All patients showed a statistically significant improvement (P = 0.001) in the Knee Society and Oxford knee rating scores. CONCLUSIONS This study demonstrated satisfactory long-term clinical outcomes for this TKA design, with revisions being related to polyethylene wear structural failure.
Collapse
|
17
|
CORR Insights®: Bearing Dislocation and Progression of Osteoarthritis After Mobile-bearing Unicompartmental Knee Arthroplasty Vary Between Asian and Western Patients: A Meta-analysis. Clin Orthop Relat Res 2018; 476:961-963. [PMID: 29601390 PMCID: PMC5916591 DOI: 10.1007/s11999.0000000000000276] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
18
|
Evaluating the durability of UHMWPE biomaterials used for articulating surfaces of joint arthroplasty using delamination tests. J Biomed Mater Res B Appl Biomater 2018; 107:65-72. [PMID: 29480570 DOI: 10.1002/jbm.b.34095] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Revised: 12/18/2017] [Accepted: 02/04/2018] [Indexed: 11/06/2022]
|
19
|
Chemical sterilization of allograft dermal tissues. Cell Tissue Bank 2017; 18:573-584. [DOI: 10.1007/s10561-017-9647-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 07/27/2017] [Indexed: 12/12/2022]
|
20
|
The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements. Proc Inst Mech Eng H 2017; 231:634-642. [PMID: 28661229 PMCID: PMC5495427 DOI: 10.1177/0954411917696112] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Complications of patellofemoral arthroplasty often occur soon after implantation and, as well as other factors, can be due to the design of the implant or its surgical positioning. A number of studies have previously considered the wear of ultra-high-molecular-weight polyethylene patellae following suboptimal implantation; however, studies have primarily been carried out under a limited number of degrees of freedom. The aim of this study was to develop a protocol to assess the wear of patellae under a malaligned condition in a six-axis patellofemoral joint simulator. The malalignment protocol hindered the tracking of the patella centrally in the trochlear groove and imparted a constant 5° external rotation (tilt) on the patella button. Following 3 million cycles of wear simulation, this condition had no influence on the wear of ultra-high-molecular-weight polyethylene patellae aged for 4 years compared to well-positioned non-aged implants (p > 0.05). However, under the malaligned condition, ultra-high-molecular-weight polyethylene patellae aged 8-10 years after unpacking (following sterilisation by gamma irradiation in an inert atmosphere) and worn ultra-high-molecular-weight polyethylene components also aged 4 years after unpacking (following the same sterilisation process) exhibited a high rate of wear. Fatigue failure due to elevated contact stress led to delamination of the ultra-high-molecular-weight polyethylene and in some cases complete failure of the patellae. The results suggest that suboptimal tracking of the patella in the trochlear groove and tilt of the patella button could have a significant effect on the wear of ultra-high-molecular-weight polyethylene and could lead to implant failure.
Collapse
|
21
|
Effects of Terminal Sterilization on PEG-Based Bioresorbable Polymers Used in Biomedical Applications. MACROMOLECULAR MATERIALS AND ENGINEERING 2016; 301:1211-1224. [PMID: 28280451 PMCID: PMC5340269 DOI: 10.1002/mame.201600133] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The effects of ethylene oxide (EO), vaporized hydrogen peroxide (VHP), gamma (γ) radiation, and electron-beam (E-beam) on the physiochemical and morphological properties of medical device polymers are investigated. Polymers with ether, carbonate, carboxylic acid, amide and ester functionalities are selected from a family of poly(ethylene glycol) (PEG) containing tyrosine-derived polycarbonates (TyrPCs) to include slow, medium, fast, and ultrafast degrading polymers. Poly(lactic acid) (PLA) is used for comparison. Molecular weight (Mw) of all tested polymers decreases upon gamma and E-beam, and this effect becomes more pronounced at higher PEG content. Gamma sterilization increases the glass transition temperature of polymers with high PEG content. EO esterifies the carboxylic acid groups in desaminotyrosol-tyrosine (DT) and causes significant degradation. VHP causes hydroxylation of the phenyl ring, and hydrolytic degradation. This study signifies the importance of the chemical composition when selecting a sterilization method, and provides suggested conditions for each of the sterilization methods.
Collapse
|
22
|
Abstract
Controlled wear testing of total hip replacements in hip joint simulators is a well-established and powerful method, giving an extensive prediction of the long-term clinical performance. To understand the wear behavior of a bearing and its limits under in vivo conditions, testing scenarios should be designed as physiologically as possible. Currently, the ISO standard protocol 14242 is the most common preclinical testing procedure for total hip replacements, based on a simplified gait cycle for normal walking conditions. However, in recent years, wear patterns have increasingly been observed on retrievals that cannot be replicated by the current standard. The purpose of this study is to review the severe testing conditions that enable the generation of clinically relevant wear rates and phenomena. These conditions include changes in loading and activity, third-body wear, surface topography, edge wear and the role of aging of the bearing materials.
Collapse
|
23
|
Surveillance of Arc2f polyethylene after 15 years of implantation. Hip Int 2015; 23:478-83. [PMID: 23934904 DOI: 10.5301/hipint.5000043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/05/2013] [Indexed: 02/04/2023]
Abstract
BACKGROUND To investigate the behavior of Arc2f polyethylene (PE) component after a minimum of 15 years post implantation and its possible reasons for failure. METHODS Between January 1988 and March 1995, 557 cementless total hip arthroplasties were performed in 578 patients. A total of 435 patients (450 hips) were followed up for 18.6 years (range 15-22). RESULTS At 10 years follow-up no cup needed revision surgery. After 15 years of implantation, we observed massive PE wear in 140 cups (31%) with large osteolytic lesions. A revision procedure was performed in all cases. Exchange only of the PE liner was sufficient in 78 cases, whilst in 59 the cup was also revised. PE insert thickness and the type of prosthetic head were found to be related to PE wear. CONCLUSIONS We postulate that the massive failure seen is attributed to the manufacturing of the PE insert. We advocate following all patients that have an implant lasting a decade after implantation for routine monitoring to identify those at risk for accelerated PE wear.
Collapse
|
24
|
Wear Performance of Sequentially Cross-Linked Polyethylene Inserts against Ion-Treated CoCr, TiNbN-Coated CoCr and Al2O3 Ceramic Femoral Heads for Total Hip Replacement. LUBRICANTS 2015. [DOI: 10.3390/lubricants3010014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
25
|
Effect of squalene absorption on oxidative stability of highly crosslinked UHMWPE stabilized with natural polyphenols. Polym Degrad Stab 2014. [DOI: 10.1016/j.polymdegradstab.2014.08.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
26
|
Can pin-on-disk testing be used to assess the wear performance of retrieved UHMWPE components for total joint arthroplasty? BIOMED RESEARCH INTERNATIONAL 2014; 2014:581812. [PMID: 25295264 PMCID: PMC4177737 DOI: 10.1155/2014/581812] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 08/18/2014] [Accepted: 08/19/2014] [Indexed: 11/17/2022]
Abstract
The objective of this study was to assess the suitability of using multidirectional pin-on-disk (POD) testing to characterize wear behavior of retrieved ultrahigh molecular weight polyethylene (UHMWPE). The POD wear behavior of 25 UHMWPE components, retrieved after 10 years in vivo, was compared with 25 that were shelf aged for 10-15 years in their original packaging. Components were gamma sterilized (25-40 kGy) in an air or reduced oxygen (inert) package. 9 mm diameter pins were fabricated from each component and evaluated against CoCr disks using a super-CTPOD with 100 stations under physiologically relevant, multidirectional loading conditions. Bovine serum (20 g/L protein concentration) was used as lubricant. Volumetric wear rates were found to vary based on the aging environment, as well as sterilization environment. Volumetric wear rates were the lowest for the pins in the gamma inert, shelf aged cohort. These results support the utility of using modern, multidirectional POD testing with a physiologic lubricant as a novel method for evaluating wear properties of retrieved UHMWPE components. The data also supported the hypothesis that wear rates of gamma-inert liners were lower than gamma-air liners for both retrieved and shelf aging conditions. However, this difference was not statistically significant for the retrieved condition.
Collapse
|
27
|
Current modes of failure in TKA: infection, instability, and stiffness predominate. Clin Orthop Relat Res 2014; 472:2197-200. [PMID: 24615421 PMCID: PMC4048402 DOI: 10.1007/s11999-014-3540-y] [Citation(s) in RCA: 170] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Accepted: 02/19/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Historically, polyethylene wear and its sequelae (osteolysis, late instability, aseptic loosening) were common causes for revision total knee arthroplasty (TKA). Recently, polyethylene manufacturing has become more consistent; furthermore, a clearer understanding of the importance of oxidation on polyethylene performance led to packaging of the polyethylene bearings in an inert environment. This improved the quality and consistency of polyethylene used in TKA, raising the question of whether different failure modes now predominate after TKA. QUESTIONS/PURPOSES The purpose of this study was to determine the current reasons for (1) early and (2) late failures after TKA at one high-volume arthroplasty center. METHODS We reviewed all first-time revision TKAs performed between 2001 and 2011 at one institution, yielding a group of 253 revision TKAs in 251 patients. Mean age at the time of revision was 64 years (SD 10 years). Mean time to revision was 35 months (SD 23 months). Preoperative evaluations, laboratory data, radiographs, and intraoperative findings were used to determine causes for revision. Early failure was defined as revision within 2 years of the index procedure. The primary failure mechanism was determined by the operating surgeon. RESULTS Early failure accounted for 46% (116 of 253) of all revisions with infection (28 of 116 [24%]), instability (30 of 116 [26%]), and stiffness (21 of 116 [18%]) being the leading causes. Late failure accounted for 54% (137 of 253) of all revisions with the most common causes including infection (34 of 137 [25%]), instability (24 of 137 [18%]), and stiffness (19 of 253 [14%]). Polyethylene wear was implicated as the failure mechanism in 2% of early cases (two of 116) and 9% of late cases (13 of 137). CONCLUSIONS In contrast to previous studies, wear-related implant failure in TKA was relatively uncommon in this series. Changes in polyethylene manufacturing, sterilization, and storage may have accounted for some of this difference; however, longer-term followup will be required to verify this finding. Infection, instability, and stiffness represent the most common causes of early and late failure. Strategies to improve outcomes in TKA should be aimed at infection prophylaxis and treatment, surgical technique, and patient selection. LEVEL OF EVIDENCE Level III, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
28
|
Oxidation and other property changes of retrieved sequentially annealed UHMWPE acetabular and tibial bearings. J Biomed Mater Res B Appl Biomater 2014; 103:578-86. [DOI: 10.1002/jbm.b.33240] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2014] [Revised: 05/20/2014] [Accepted: 06/05/2014] [Indexed: 11/08/2022]
|
29
|
Quantification of structural changes of UHMWPE components in total joint replacements. BMC Musculoskelet Disord 2014; 15:109. [PMID: 24678698 PMCID: PMC3986646 DOI: 10.1186/1471-2474-15-109] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2013] [Accepted: 03/24/2014] [Indexed: 11/17/2022] Open
Abstract
Background At present time the number of implantations of joint replacements as well as their revisions increases. Higher demands are required on the quality and longevity of implants. The aim of this work was to determine the degree of oxidative degradation and the amount of free/residual radicals in selected ultra-high molecular weight polyethylene (UHMWPE) components of the joint replacements and demonstrate that the measured values are closely connected with quality and lifetime of the polymer components. Methods We tested both new (4 samples) and explanted (4 samples) UHMWPE polymers for total joint replacements. The samples were characterized by infrared spectroscopy (IR), electron spin resonance (ESR) and microhardness (MH) test. The IR measurements yielded the values of oxidation index and trans-vinylene index. The ESR measurements gave the free radicals concentration. Results In the group of new polyethylene components, we found oxidation index values ranging from 0.00-0.03 to 0.24. The trans-vinylene index values ranged from 0.044 to 0.080. The value of free radical concentration was zero in virgin and also in sample of Beznoska Company and non-zero in the other samples. In the group of explanted components, the measured values were associated with their history, micromechanical properties and performance in vivo. Conclusions We demonstrated that measuring of oxidative damage may help the orthopaedic surgeon in estimating the quality of UHMWPE replacement component and thus radically to avoid early joint replacement failure due to worse polyethylene quality.
Collapse
|
30
|
Abstract
We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual’s functional demands. Cite this article: Bone Joint J 2014;96-B:147–56.
Collapse
|
31
|
Total knee prosthesis polyethylene wear reduction by a new
metal part finishing method. J Appl Biomater Funct Mater 2013; 11:e99-e105. [PMID: 23728542 DOI: 10.5301/jabfm.5000153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/22/2012] [Indexed: 11/20/2022] Open
Abstract
PURPOSE The purpose of this study was to assess a new metal component finishing designed to improve total knee prosthesis durability. Wear of ultrahigh molecular-weight polyethylene (UHMWPE), with generation of submicrometer- and micrometer-sized particles, has been associated with osteolysis and artificial joint failure. Wear extent is influenced by several factors, some of which are related to manufacturing. METHODS UHMWPE wear was assessed in metal prosthesis components finished with the Microloy® technology and in traditionally finished components by wear simulation experiments (pin on disk and knee simulator tests) and analysis of wear debris. RESULTS Microloy®-finished prosthesis showed a 48.5% reduction in UHMWPE total weight loss compared with traditional components (P=0.002). A statistically significant (P<0.05) reduction of UHMWPE debris were detected from the Microloy®-finished compared with the traditionally finished components. CONCLUSIONS These findings suggest the Microloy® metal finishing may enhance the long-term performance of knee prostheses.
Collapse
|
32
|
Mechanical behavior, microstructure and thermooxidation properties of sequentially crosslinked ultrahigh molecular weight polyethylenes. J Appl Polym Sci 2013. [DOI: 10.1002/app.38956] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
33
|
|
34
|
|
35
|
In vivo oxidation and surface damage in retrieved ethylene oxide-sterilized total knee arthroplasties. Clin Orthop Relat Res 2012; 470:1826-33. [PMID: 22125241 PMCID: PMC3369100 DOI: 10.1007/s11999-011-2184-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Gas sterilization (eg, ethylene oxide [EtO] and gas plasma) was introduced for polyethylene to reduce oxidation due to free radicals occurring during radiation sterilization. Recently, oxidation has been observed in polyethylenes with undetectable levels of free radicals, which were expected to be oxidatively stable. It is unclear whether in vivo oxidation will occur in unirradiated inserts sterilized with EtO. QUESTIONS/PURPOSES We analyzed the oxidation, mechanical behavior, and surface damage mechanisms of tibial inserts of a single design sterilized using EtO. METHODS We collected 20 EtO-sterilized tibial inserts at revision surgeries. We assessed oxidative using Fourier transform infrared spectroscopy and mechanical properties using the small punch test. Surface damage was assessed using damage scoring techniques and micro-CT. RESULTS Oxidation indexes were low and uniform between the regions. The subtle changes did not affect the mechanical properties of the polymer. The dominant surface damage modes included burnishing, abrasion, and third-body wear. There was no evidence of delamination in the retrievals. CONCLUSIONS The retrieved EtO-sterilized UHMWPE retrievals remained stable with respect to both oxidative and mechanical properties for up to 10 years in vivo. We did observe slight measurable amounts of oxidation in the inserts; however, it was far below levels that would be expected to compromise the strength of the polymer. CLINICAL RELEVANCE Due to the stable oxidative and mechanical properties, EtO-sterilized tibial components appear to be an effective alternative to gamma-sterilized inserts, at least in short-term implantations.
Collapse
|
36
|
Abstract
BACKGROUND In the mid to late 1990 s, to sterilize UHMWPE bearings, manufacturers changed from gamma-irradiation-in-air (gamma-air) sterilization, which initiated oxidation leading to bearing fatigue, to gamma-irradiation sterilization in an inert environment (gamma-inert). The change to gamma-inert sterilization reportedly prevented shelf oxidation before implantation but not in vivo oxidation. QUESTIONS/PURPOSES We asked: (1) Has the change to gamma-inert sterilization prevented shelf oxidation that led to early in vivo fatigue damage in gamma-air-sterilized tibial inserts? And (2) has the change to gamma-inert sterilization prevented the occurrence of fatigue secondary to in vivo oxidation? METHODS We rated 183 retrieved gamma-air- and 175 retrieved gamma-inert-sterilized tibial inserts for clinical fatigue damage and analyzed 132 gamma-air- and 174 gamma-inert-sterilized tibial inserts for oxidation by Fourier transform infrared spectroscopy. RESULTS Oxidation led to decreased mechanical properties in shelf-aged gamma-air-sterilized tibial inserts. Barrier packaging prevented shelf oxidation in gamma-inert-sterilized tibial inserts. Gamma-air- and gamma-inert-sterilized inserts oxidized in vivo. Fatigue damage (delamination) occurred more frequently in inserts retrieved after longer time in vivo. Longer in vivo time correlated with higher oxidation and more accumulated cycles of use. CONCLUSIONS Published oxidation projections suggest gamma-inert-sterilized tibial inserts would reach the critical oxidation for the onset of fatigue after 11 to 14 years in vivo. These retrievals appear to follow the projected oxidation trends. Frequency of fatigue damage increased with increasing oxidation. CLINICAL RELEVANCE Fatigue of tibial inserts becomes more likely, especially in active patients, after more than a decade of good clinical performance.
Collapse
|
37
|
The influence of sterilization method on articular surface damage of retrieved cruciate-retaining tibial inserts. J Arthroplasty 2012; 27:1085-93. [PMID: 22177798 DOI: 10.1016/j.arth.2011.10.023] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Accepted: 10/24/2011] [Indexed: 02/01/2023] Open
Abstract
This observational study was designed to determine the importance of sterilization method and insert thickness as predictors of articular damage of cruciate-retaining polyethylene components used in total knee arthroplasty. Ninety-nine explanted tibial inserts were evaluated for surface damage. Severe damage modes were observed in 36 of 52 of γ-irradiated inserts but none of those sterilized by ethylene oxide. Articular damage significantly correlated to time in vivo but not to insert thickness. Inserts sterilized by ethylene oxide gas in gas-permeable packaging exhibited a significantly lower damage accumulation rate compared with inserts sterilized by γ radiation and stored in air or an inert environment. γ irradiation and storage in argon instead of air reduced the frequency of severe damage such as delamination but not the overall damage rate.
Collapse
|
38
|
Abstract
BACKGROUND Highly crosslinked and thermally treated polyethylenes were clinically introduced to reduce wear and osteolysis. Although the crosslinking process improves the wear performance, it also introduces free radicals into the polymer that can subsequently oxidize. Thermal treatments have been implemented to reduce oxidation; however, the efficacy of these methods with regard to reducing in vivo oxidative degradation remains to be seen. Polyethylene oxidation is a concern because it can compromise the ultimate strength and ductility of the material. QUESTIONS/PURPOSES We analyzed the oxidation, oxidation potential, and mechanical behavior of thermally treated highly crosslinked polyethylene retrieved acetabular liners. METHODS Three hundred seven acetabular liners were collected from consecutive revision surgeries at six institutions over a 10-year period. Twenty-four were sterilized using nonionizing methods, 43 were sterilized in an inert environment, 80 were highly crosslinked and annealed, and 160 were highly crosslinked and remelted. Oxidation and oxidation potential were assessed by Fourier transmission infrared spectroscopy. Mechanical behavior was assessed by the small punch test. RESULTS Oxidation and hydroperoxide (oxidation potential) indices were elevated in the annealed and gamma inert sterilized groups compared with those of the remelted liners and uncrosslinked gas sterilized controls, particularly at the rim. We also detected an increase in oxidation over time at the bearing surface of the remelted group. Ultimate strength of the polyethylene at the bearing surface was negatively correlated with implantation time for the annealed liners. CONCLUSIONS Within the first decade of implantation, the clinical outlook for first-generation highly crosslinked polyethylene remains promising. However, ongoing research continues to be warranted for first-generation highly crosslinked polyethylene bearings to monitor the implications of elevated oxidation at the rim of annealed liners as well as to better understand the subtle changes in oxidation at the bearing surface of remelted liners that occur in vivo.
Collapse
|
39
|
In vivo oxidation contributes to delamination but not pitting in polyethylene components for total knee arthroplasty. J Arthroplasty 2011; 26:802-10. [PMID: 20875942 PMCID: PMC3385511 DOI: 10.1016/j.arth.2010.07.010] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Accepted: 07/18/2010] [Indexed: 02/01/2023] Open
Abstract
The aim of this study was to better understand how in vivo oxidation contributes to fatigue damage in total knee arthroplasty (TKA). A total of 119 tibial inserts were consecutively collected after revision surgery. Of the 119 polyethylene retrievals, 29 were gamma sterilized in air (historical), whereas the remaining 90 were gamma sterilized in nitrogen (conventional). Surface damage assessment and characterization of oxidation were performed on all the retrievals. Delamination was significantly more prevalent and extensive in the longer-term, highly oxidized, historical tibial inserts. Pitting damage, in contrast, seemed to be equally prevalent between both retrieval groups and was not correlated with in vivo oxidation. Our findings support our hypothesis that in vivo oxidation is a contributing factor to delamination, but not pitting, in TKA. Despite the lower oxidation displayed by conventional retrievals, this study provides strong evidence that delamination secondary to in vivo oxidation may occur during the second decade of implantation.
Collapse
|
40
|
Abstract
BACKGROUND Elimination of free radicals to prevent oxidation has played a major role in the development and product differentiation of the latest generation of highly cross-linked ultra-high molecular weight polyethylene bearing materials. In the current study, we (1) examined oxidation in a series of retrieved remelted highly cross-linked ultra-high molecular weight polyethylene bearings from a number of device manufacturers and (2) compared the retrieval results with findings for shelf-stored control specimens. The hypothesis was that radiation-cross-linked remelted ultra-high molecular weight polyethylene would maintain oxidative stability in vivo comparable with the stability during shelf storage and in published laboratory aging tests. METHODS Fifty remelted highly cross-linked ultra-high molecular weight polyethylene acetabular liners and nineteen remelted highly cross-linked ultra-high molecular weight polyethylene tibial inserts were received after retrieval from twenty-one surgeons from across the U.S. Thirty-two of the retrievals had been in vivo for two years or more. Each was measured for oxidation with use of Fourier transform infrared spectroscopy. A control series of remelted highly cross-linked ultra-high molecular weight polyethylene acetabular liners from three manufacturers was analyzed with electron paramagnetic resonance spectroscopy to measure free radical content and with Fourier transform infrared spectroscopy to measure oxidation initially and after eight to nine years of shelf storage in air. RESULTS The never-implanted, shelf-aged controls had no measurable free-radical content initially or after eight to nine years of shelf storage. The never-implanted controls showed no increase in oxidation during shelf storage. Oxidation measurements showed measurable oxidation in 22% of the retrieved remelted highly cross-linked liners and inserts after an average of two years in vivo. CONCLUSIONS Because never-implanted remelted highly cross-linked ultra-high molecular weight polyethylene materials had no measurable free-radical concentration and no increase in oxidation during shelf storage, these materials were expected to be oxidation-resistant in vivo. However, some remelted highly cross-linked ultra-high molecular weight polyethylene retrievals showed measurable oxidation after an average of more than two years in vivo. This apparent departure from widely expected behavior requires continued study of the process of in vivo oxidation of ultra-high molecular weight polyethylene materials.
Collapse
|
41
|
Wear, delamination, and fatigue resistance of melt-annealed highly crosslinked UHMWPE cruciate-retaining knee inserts under activities of daily living. J Orthop Res 2010; 28:1120-6. [PMID: 20162713 DOI: 10.1002/jor.21104] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The wear, delamination, and fatigue resistance of artificially aged gamma irradiation-sterilized conventional polyethylene (CPE) and gas-plasma-sterilized melt-annealed highly crosslinked polyethylene tibial inserts (HXPE) were compared. Six CPE and 12 HXPE (six irradiated at 58 kGy and six at 72 kGy) left knee inserts were wear tested for 5.5 million cycles (Mc) under loads and motions that mimic activities of daily living, such as walking, chair rise, stair ascent, and deep squatting. Another six HXPE (72 kGy) and six CPE inserts were also tested under conditions that could produce severe delamination for 8 Mc. Ten other knees (five 72 kGy HXPE and five CPE) were subjected to posterior edge loading fatigue testing for 5 Mc. The HXPE inserts had an average wear rate reduction of about 80% relative to their CPE counterparts during all activities. All of the CPE inserts delaminated and fractured during high cycle deep squat (152 degrees flexion) motions, while all the HXPE remained intact. None of the HXPE inserts delaminated after 8 Mc, while all of the CPE inserts developed delamination damage within 1.5-5.8 Mc of delamination testing. All CPE inserts developed subsurface cracks and delamination within 2.8 Mc during posterior edge loading fatigue studies, while none of the HXPE inserts showed cracking or delamination after 5 Mc. These results show that aged HXPE has higher wear and fatigue resistance than aged CPE, and offers potential long-term advantages for young active patients with sustained activities of daily living.
Collapse
|
42
|
Reasons for revision of first-generation highly cross-linked polyethylenes. J Arthroplasty 2010; 25:67-74. [PMID: 20541895 PMCID: PMC2946323 DOI: 10.1016/j.arth.2010.04.018] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2009] [Accepted: 04/01/2010] [Indexed: 02/01/2023] Open
Abstract
Over a 10-year period, we prospectively evaluated the reasons for revision of contemporary and highly cross-linked polyethylene formulations in amulticenter retrieval program. Two hundred twelve consecutive retrievals were classified as conventional gamma inert sterilized (n = 37), annealed (Cross fire,[Stryker Orthopedics, Mahwah, NJ] n = 72), or remelted (Longevity [Zimmer ,Warsaw, Ind], XLPE[Smith and Nephew, Memphis, Tenn], Durasul [Zimmer,Warsaw, Ind] n = 103) liners. The most frequent reasons for revision were loosening (35%), instability(28%), and infection (21%) and were not related to polyethylene formulation (P = .17). Annealed and remelted liners had comparable linear penetration rates(0.03 and 0.04 mm/y, respectively, on average), and these were significantly lower than the rate in conventional retrievals (0.11 mm/y, P ≤ .0005). This retrieval study including first-generation highly cross linked liners demonstrated lower wear than conventional polyethylene. Although loosening remained as the most prevalent reason for revision, we could not demonstrate a relationship between wear and loosening.The long-term clinical performance of first-generation highly cross-linked liners remains promising based on the midterm outcomes of the components documented in this study [corrected].
Collapse
|
43
|
|
44
|
Polyethylene oxidation in total hip arthroplasty: evolution and new advances. Open Orthop J 2009; 3:115-20. [PMID: 20111694 PMCID: PMC2812841 DOI: 10.2174/1874325000903010115] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2009] [Revised: 10/23/2009] [Accepted: 10/29/2009] [Indexed: 01/06/2023] Open
Abstract
Ultra-high molecular weight polyethylene (UHMWPE) remains the gold standard acetabular bearing material for hip arthroplasty. Its successful performance has shown consistent results and survivorship in total hip replacement (THR) above 85% after 15 years, with different patients, surgeons, or designs. As THR results have been challenged by wear, oxidation, and liner fracture, relevant research on the material properties in the past decade has led to the development and clinical introduction of highly crosslinked polyethylenes (HXLPE). More stress on the bearing (more active, overweighted, younger patients), and more variability in the implantation technique in different small and large Hospitals may further compromise the clinical performance for many patients. The long-term in vivo performance of these materials remains to be proven. Clinical and retrieval studies after more than 5 years of in vivo use with HXLPE in THR are reviewed and consistently show a substantial decrease in wear rate. Moreover, a second generation of improved polyethylenes is backed by in vitro data and awaits more clinical experience to confirm the experimental improvements. Also, new antioxidant, free radical scavengers, candidates and the reinforcement of polyethylene through composites are currently under basic research.Oxidation of polyethylene is today significantly reduced by present formulations, and this forgiving, affordable, and wellknown material is still reliable to meet today's higher requirements in total hip replacement.
Collapse
|