1
|
Ramsodit KR, Sierevelt IN, Janssen ERC, Kaarsemaker S, Haverkamp D. Mid-term clinical outcomes of the uncemented Robert Mathys pressfit cup. World J Clin Cases 2024; 12:3684-3691. [PMID: 38994294 PMCID: PMC11235464 DOI: 10.12998/wjcc.v12.i19.3684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 04/25/2024] [Accepted: 05/16/2024] [Indexed: 06/29/2024] Open
Abstract
BACKGROUND The use of uncemented cups during total hip arthroplasty (THA) has gained popularity in recent years. The Robert Mathys (RM) pressfit cup, an uncemented monoblock implant is expected to preserve bone density due to its composition and external surface, while reducing backside wear with its monoblock construction. These factors should lead to a high survival rate of the implant. AIM To evaluate the mid-term survival and functional outcome of the RM Pressfit cup in a large study population. METHODS Between 2011 and 2020, we included 1324 patients receiving a primary THA using the RM pressfit cup. Final clinical follow-up was performed at 2 years postoperatively with the Dutch arthroplasty register used to assess implant status thereafter. Revision for acetabular failure and reason for revision were reported to evaluate implant survival, while the hip disability and osteoarthritis outcome score (HOOS) scores were used to assess functional outcome. RESULTS The mean age at surgery was 64.9 years. The mean follow-up was 4.6 years. Of the 1324 THAs performed, 13 needed cup revisions within 5 years after index THA: 5 due to aseptic loosening, 6 due to infection, 2 due to dislocation and 2 due to other causes. This resulted in a 5-year cup survival of 98.8% (95%CI: 98.1-99.5). Nine of the cup revisions occurred within the first year after index THA. HOOS scores increased significantly in all domains during the first year and levelled out during the second year. CONCLUSION In the present study, the RM pressfit cup demonstrated excellent clinical outcomes at mid-term follow-up; however, future studies are needed to assess the long-term outcomes of this acetabular implant.
Collapse
Affiliation(s)
- Kishan Ritek Ramsodit
- Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands
| | - Inger N Sierevelt
- Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands
- Department of Orthopedic, Spaarne Gasthuis Academy, Hoofddorp 2134 TM, Netherlands
| | - Esther R C Janssen
- Department of Orthopaedic Surgery, Viecuri Medical Centre, Venlo 5912 BL, Netherlands
| | - Sjoerd Kaarsemaker
- Department of Orthopaedic Surgery, Viecuri Medisch Centrum, Venlo 5912 BL, Netherlands
| | - Daniël Haverkamp
- Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands
| |
Collapse
|
2
|
Robertson TS, Pijls BG, Munn Z, Solomon LB, Nelissen RGHH, Callary SA. Change in CT-measured acetabular bone density following total hip arthroplasty: a systematic review and meta-analysis. Acta Orthop 2023; 94:191-199. [PMID: 37114317 PMCID: PMC10140760 DOI: 10.2340/17453674.2023.11635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Indexed: 04/29/2023] Open
Abstract
BACKGROUND AND PURPOSE Assessing peri-acetabular bone quality is valuable for optimizing the outcomes of primary total hip arthroplasty (THA) as preservation of good quality bone stock likely affects implant stability. The aim of this study was to perform a meta-analysis of peri-acetabular bone mineral density (BMD) changes over time measured using quantitative computer tomography (CT) and, second, to investigate the influence of age, sex, and fixation on the change in BMD over time. METHODS A systematic search of Embase, Scopus, Web of Science, and PubMed databases identified 19 studies that measured BMD using CT following THA. The regions of interest (ROI), reporting of BMD results, and scan protocols were extracted. A meta-analysis of BMD was performed on 12 studies that reported measurements immediately postoperatively and at follow-up. RESULTS The meta-analysis determined that periacetabular BMD around both cemented and uncemented components decreases over time. The amount of BMD loss increased relative to proximity of the acetabular component. There was a greater decrease in cortical BMD over time in females and cancellous BMD for young patients of any sex. CONCLUSION Peri-acetabular BMD decreases at different rates relative to its proximity to the acetabular component. Cancellous BMD decreases more in young patients and cortical bone decreases more in females. Standardized reporting parameters and suggested ROI to measure peri-acetabular BMD are proposed, to enable comparison between implant and patient variables in the future.
Collapse
Affiliation(s)
- Thomas S Robertson
- Department of Orthopaedics and Trauma Royal Adelaide Hospital, Adelaide, SA, Australia; Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia.
| | - Bart G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Zachary Munn
- JBI, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA Australia
| | - L Bogdan Solomon
- Department of Orthopaedics and Trauma Royal Adelaide Hospital, Adelaide, SA, Australia; Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Stuart A Callary
- Department of Orthopaedics and Trauma Royal Adelaide Hospital, Adelaide, SA, Australia; Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia
| |
Collapse
|
3
|
García-Rey E, Carbonell-Escobar R, Cordero-Ampuero J, García-Cimbrelo E. Outcome of a hemispherical porous-coated acetabular component with a proximally hydroxyapatite-coated anatomical femoral component. Bone Joint J 2019; 101-B:378-385. [DOI: 10.1302/0301-620x.101b4.bjj-2018-1223.r1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims We previously reported the long-term results of the cementless Duraloc-Profile total hip arthroplasty (THA) system in a 12- to 15-year follow-up study. In this paper, we provide an update on the clinical and radiological results of a previously reported cohort of patients at 23 to 26 years´ follow-up. Patients and Methods Of the 99 original patients (111 hips), 73 patients (82 hips) with a mean age of 56.8 years (21 to 70) were available for clinical and radiological study at a minimum follow-up of 23 years. There were 40 female patients (44 hips) and 33 male patients (38 hips). Results All acetabular and femoral components were well fixed and showed signs of bone ingrowth. Nine acetabular components were revised due to wear-osteolysis-related problems and four due to late dislocation. The probability of not having component revision at 25 years was 83.2% (95% confidence interval (CI) 74.5 to 91.8; number at risk 41). Acetabular osteolysis was observed in ten hips. The mean femoral head penetration was 1.52 mm (sd 0.8) at 15 years and 1.92 mm (sd 1.2) at 25 years. Receiver operating characteristic (ROC) analysis revealed that mean femoral penetration with a value of 0.11 mm/year or more was associated with the appearance of osteolysis. The 25-year Kaplan–Meier survival with different endpoints was 89.9% for acetabular osteolysis (95% CI 83.3 to 96.5), 92.1% for proximal femoral osteolysis (95% CI 86.1 to 98.2), and 75.5% for femoral osteopenia (95% CI 66.5 to 84.5). Conclusion The Duraloc-Profile THA system showed excellent long-term bone fixation. Nevertheless, monitoring is recommended in order to detect wear and late dislocations in this population that was relatively young at the time of surgery. Cite this article: Bone Joint J 2019;101-B:378–385.
Collapse
Affiliation(s)
- E. García-Rey
- Orthopaedics Department, Hospital Universitario La Paz-Idi Paz, Madrid, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain
| | | | - J. Cordero-Ampuero
- Orthopaedics Department, Hospital Universitario La Princesa, Madrid, Spain
| | - E. García-Cimbrelo
- Orthopaedics Department, Hospital Universitario La Paz-Idi Paz, Madrid, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain
| |
Collapse
|
4
|
Gerhardt DM, Smolders JM, Roovers EA, Rijnders TA, van Susante JL. Changes in periacetabular bone mineral density five years after resurfacing hip arthroplasty versus conventional total hip arthroplasty. Hip Int 2019; 29:153-160. [PMID: 30426791 DOI: 10.1177/1120700018808023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: We studied whether acetabular bone mineral density (BMD) is better preserved after resurfacing hip arthroplasty (RHA) versus small diameter metal-on-metal total hip arthroplasty (THA). METHODS: This randomised controlled trial included 82 patients. BMD was measured in 5 periprosthetic regions of interest (ROI) with dual-energy absorptiometry (DEXA) preoperatively, at 3 and 6 months, 1, 2, 3 and 5 years postoperative. 34 RHA and 26 THA had a complete 5 years follow-up. 1 RHA and 1 THA were revised due to pseudotumour formation, 2 THA were revised because of recurrent dislocations and 1 RHA for avascular necrosis. RESULTS: Overall an initial decrease in BMD was observed for both implants, stabilising after 2 years. 5 years after RHA a BMD change of +1% in upper cranial, -4% ( p < 0.01) in cranial, -8% ( p < 0.01) in craniomedial, -7% ( p < 0.01) in medial and +4% in caudal ROI compared to baseline values was seen. 5 years after THA a BMD change of -3% ( p = 0.01), -13% ( p < 0.01), -21% ( p < 0.01), -11% ( p < 0.01) and -2% for each respective ROI. The observed BMD decrease in different regions was structurally favouring the RHA-cup, with significantly higher levels in the cranial and craniomedial ROI. CONCLUSION: Acetabular BMD is better preserved behind a rigid press-fit convex cup in RHA compared to a titanium threaded cup in conventional THA in the cranial and craniomedial ROI. Despite of a theoretical higher stress-shielding behind the stiff acetabular component in RHA, compared to the more elastic threaded titanium THA-cup, bone depletion behind the RHA component does not seem to be of major concern. REGISTRATION: EudraCT (2006-005610-12).
Collapse
Affiliation(s)
- Davey Mjm Gerhardt
- 1 Department of Orthopaedics, Rijnstate Hospital, Arnhem, The Netherlands
| | - José Mh Smolders
- 1 Department of Orthopaedics, Rijnstate Hospital, Arnhem, The Netherlands
| | - Elisabeth A Roovers
- 2 Department of Orthopedics/Research, Rijnstate Hospital, Arnhem, The Netherlands
| | - Ton Ajm Rijnders
- 3 Department of Nuclear Medicine, Rijnstate Hospital, Arnhem, The Netherlands
| | - Job Lc van Susante
- 1 Department of Orthopaedics, Rijnstate Hospital, Arnhem, The Netherlands
| |
Collapse
|
5
|
Mussmann B, Andersen PE, Torfing T, Overgaard S. Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study. Acta Radiol Open 2018; 7:2058460118796539. [PMID: 30186626 PMCID: PMC6117866 DOI: 10.1177/2058460118796539] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 08/02/2018] [Indexed: 12/17/2022] Open
Abstract
Background Measuring bone mineral density (BMD) around acetabular prosthetic components with computed tomography (CT) is challenged by the complex anatomy and metal artifacts. Three-dimensional (3D) segmentation is required for the analysis, but it is usually not practically applicable on current CT workstations Purpose To test the between-scan agreement and reliability of custom segmentation software for BMD measurements adjacent to cemented and uncemented acetabular cups in dual-energy CT (DECT). Material and Methods Twenty-four male patients with total hip arthroplasty were scanned and rescanned using 130-keV virtual monochromatic DECT images. Hemispherical regions of interest were defined slice-by-slice and BMD was calculated around the acetabular cup using custom segmentation software. Results In the uncemented cup, the mean BMD was 153 mg/cm3 with a between-scan difference of 10 mg/cm3 (P < 0.0001). In the cemented cup, the mean BMD was 186 mg/cm3 with a between-scan difference of 6 mg/cm3 (P = 0.15). In both uncemented and cemented cups the intraclass correlation coefficient between repeated measurements was >0.95 and narrow Bland–Altman Limits of Agreement. Conclusion BMD can be measured with high absolute between-scan agreement and good reliability adjacent to acetabular cemented and uncemented cups using DECT and segmentation software.
Collapse
Affiliation(s)
- Bo Mussmann
- Department of Radiology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Poul Erik Andersen
- Department of Radiology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Trine Torfing
- Department of Radiology, Odense University Hospital, Odense, Denmark
| | - Søren Overgaard
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.,Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
| |
Collapse
|
6
|
Mussmann B, Overgaard S, Torfing T, Bøgehøj M, Gerke O, Andersen PE. Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup: a porcine ex-vivo study using single- and dual-energy computed tomography. Acta Radiol Open 2017; 6:2058460117719746. [PMID: 28785480 PMCID: PMC5521355 DOI: 10.1177/2058460117719746] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Accepted: 06/17/2017] [Indexed: 11/25/2022] Open
Abstract
Background Periprosthetic bone loss is considered to be a potentially contributing factor in aseptic loosening of acetabular hip components, but no studies have shown this association. The lack of association might be caused by insufficient image quality because of metal artifacts and challenges in measuring bone density (BMD) in complex anatomic structures which might be overcome using dual-energy computed tomography (DECT). Purpose To test inter- and intra-observer agreement and reliability of in-house segmentation software measuring BMD adjacent to acetabular cup and to compare measurements performed with single-energy CT (SECT) and DECT in cemented and cementless cups. Material and Methods Twenty-four acetabular cups inserted in porcine hip specimens were scanned with SECT and DECT. Bone density was measured in a three-dimensional volume adjacent to the cup. Double measurements were performed. Results BMD derived from SECT was approximately four times higher than that of DECT. In both scan modes, intraclass correlation coefficient (ICC) was >0.90 with no differences between repeated measurements, except for uncemented cups where a statistically significant difference of 11 mg/cm3 was found with DECT. DECT showed narrower limits of agreement than SECT. Inter-observer analysis showed small differences. Conclusion BMD can be estimated with high intra- and inter-observer reliability with SECT and DECT around acetabular cups using custom software. The intra- and inter-observer agreement of DECT is superior to that of SECT and better in the cementless concept. Good intra- and inter-observer reliability can be obtained in both cemented and cementless cups using the segmentation software. SECT and DECT cannot be used interchangeably.
Collapse
Affiliation(s)
- Bo Mussmann
- Department of Radiology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Søren Overgaard
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.,Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
| | - Trine Torfing
- Department of Radiology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Morten Bøgehøj
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.,Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
| | - Oke Gerke
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark.,Centre of Health Economics Research, University of Southern Denmark, Odense, Denmark
| | - Poul Erik Andersen
- Department of Radiology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
7
|
García-Rey E, Cruz-Pardos A, García-Cimbrelo E. The evolution of an uncemented acetabular component in alumina-on-alumina total hip arthroplasty has improved clinical outcome. Bone Joint J 2017; 99-B:749-758. [DOI: 10.1302/0301-620x.99b6.bjj-2016-0045.r3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2016] [Accepted: 10/05/2016] [Indexed: 11/05/2022]
Abstract
Aims To determine the effect of a change in design of a cementless ceramic acetabular component in fixation and clinical outcome after total hip arthroplasty Patients and Methods We compared 342 hips (302 patients) operated between 1999 and 2005 with a relatively smooth hydroxyapatite coated acetabular component (group 1), and 337 hips (310 patients) operated between 2006 and 2011 using a similar acetabular component with a macrotexture on the entire outer surface of the component (group 2). The mean age of the patients was 53.5 (14 to 70) in group 1 and 53.0 (15 to 70) in group 2. The mean follow-up was 12.7 years (10 to 17) for group 1 and 7.2 years (4 to 10) for group 2. Results No hips were revised due to complications related to bearing fracture or to stem loosening. A total of 15 acetabular components were revised for aseptic loosening in group 1 and two in group 2. The survival rate for acetabular component aseptic loosening at eight years was 96.8% (95% confidence interval (CI) 94.8 to 98.7) for group 1 and 99.2% (95% CI 98.0 to 100) for group 2. The risk for aseptic loosening of the acetabular component was higher in group 1 (p = 0.04, Hazard Ratio (HR) 4.99), dysplastic acetabula (p = 0.01, HR 4.12), components outside Lewinnek´s zone (p < 0.001, HR 6.13) and in those with a hip rotation centre distance greater than 5 mm (p = 0.005, HR 4.09). Conclusion Alumina ceramic-on-ceramic THA is an excellent option for young patients. Although newer components appeared to improve fixation, acetabular reconstruction is essential to obtain a satisfactory outcome. Cite this article: Bone Joint J 2017;99-B:749–58.
Collapse
Affiliation(s)
- E. García-Rey
- Hospital La Paz-Idi Paz, Orthopaedics
Department, Madrid, Spain
| | - A. Cruz-Pardos
- Hospital La Paz-Idi Paz, Orthopaedics
Department, Madrid, Spain
| | | |
Collapse
|
8
|
Screws are not needed when secure interference fit of uncemented acetabular components is adequate: a 5- to 15-year follow-up with clinical and radiological analysis. Hip Int 2017; 27:267-272. [PMID: 28165596 DOI: 10.5301/hipint.5000459] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/15/2016] [Indexed: 02/04/2023]
Abstract
PURPOSE Even with good surgical preparation, adequate primary stability of the acetabular component is not always achieved after primary total hip replacement (THR). We hypothesise that adequate bone preparation for appropriate cortical loading would allow us to avoid screw use. METHODS A total of 791 uncemented cups were analysed to compare the need for screws to obtain primary fixation in 5 different designs. Arthritic hips with inflammatory arthritis or severe congenital hip disease were excluded. A press-fit technique was first tried in all hips and screws were only used when strictly needed. Radiological acetabular shape and postoperative cup position were assessed in all hips. The mean follow-up was 9.6 (5-15) years. RESULTS Screws were required in 155 hips (19.6%). We could not detect any difference in the percentage of screw use between designs. We found that female patients (odds ratio [OR] 2.06; 95% confidence interval [CI], 1.41-3.02) and cups with a greater distance to the hip rotation centre on the postoperative radiograph (OR 1.69; 95% CI, 1.17-2.45) had a higher risk for screw use. A greater anteversion of the cup had a lower risk for screw use (OR 0.96; 95% CI, 0.94-0.99). At latest follow-up no hips had needed revision for aseptic loosening. CONCLUSIONS Good intraoperative technique is not enough to avoid screw use since more accurate cup position and reconstruction of the hip rotation centre are required for an adequate interference fit. A press-fit technique can provide similar mid-term results to screw use in hips without severe deformities.
Collapse
|
9
|
Increase in physical activity after resurfacing hip arthroplasty is associated with calcar and acetabular bone mineral density changes. Hip Int 2017; 27:140-146. [PMID: 28218380 DOI: 10.5301/hipint.5000433] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/17/2016] [Indexed: 02/04/2023]
Abstract
PURPOSE Bone preservation is an important advantage of the resurfacing hip arthroplasty (RHA) concept. We hypothesised that patients' increase in physical activity level after RHA would positively relate with periprosthetic bone mineral density (BMD) changes and thus facilitate bone preservation. METHODS BMD-changes were prospectively recorded in 38 patients after RHA. Dual-energy absorptiometry was used to quantify BMD-changes in 6 periprosthetic regions of interest preoperatively, at 6 months, 1, 2 and 3 years postoperative. The effect estimates of patients' physical activity, according to their Harris Hip Score (HHS) and University of California at Los Angeles (UCLA) Activity Score, on these BMD changes were assessed in linear mixed models. RESULTS The UCLA (coefficient = 0.02 (95% CI, 0.010-0.034); p<0.001) and HHS (coefficient = 0.002 (95% CI, 0.001-0.003); p<0.001) were associated with the BMD in the calcar region. As for BMD changes in the femoral neck only the HHS was associated (coefficient = 0.0006 (95% CI, <0.0001-0.001); p = 0.04). Both the UCLA and the HHS were inversely associated with BMD in the medial acetabular region (UCLA: coefficient = -0.02 (95% CI, -0.038 to -0.007); p = 0.005, HHS: coefficient = -0.002 (95% CI, -0.003 to -0.001), the same accounted for the HHS to BMD-change cranial to the acetabulum (-0.001 [95% CI, -0.0018 to -0.0001]; p = 0.03). For the caudal acetabular and femoral subtrochanteric region no relation with BMD-changes was found. CONCLUSIONS The increase in activity scores after RHA was indeed associated with an increase in BMD in the calcar region, however unexpectedly also with a BMD decrease on the acetabular side. Stress shielding from the implant is the most likely causative factor.
Collapse
|
10
|
Pakvis DFM, Heesterbeek PJC, Severens M, Spruit M. Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty. Acta Orthop 2016; 87:583-588. [PMID: 27659074 PMCID: PMC5119440 DOI: 10.1080/17453674.2016.1237439] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The acetabular component has remained the weakest link in hip arthroplasty for achievement of long-term survival. One of the possible explanatory factors for acetabular failure has been acetabular stress shielding. For this, we investigated the effects of a cementless elastic socket on acetabular bone mineral density (BMD). Patients and methods - During 2008-2009, we performed a single-center prospective cohort trial on 25 patients (mean age 64 (SD 4), 18 females) in whom we implanted a cementless elastic press-fit socket. Using quantitative BMD measurements on CT, we determined the change in BMD surrounding the acetabular component over a 2-year follow-up period. Results - We found a statistically significant decrease in cancellous BMD (-14% to -35%) and a stable level of cortical BMD (5% to -5%) surrounding the elastic press-fit cup during the follow-up period. The main decrease was seen during the first 6 months after implantation. During the second year, cancellous BMD showed a further decrease in the medial and lower acetabular regions. Interpretation - We found no evidence that an elastic press-fit socket would prevent acetabular stress shielding during a 2-year follow-up.
Collapse
Affiliation(s)
- Dean F M Pakvis
- Department of Orthopaedic surgery, Sint Maartenskliniek;,Correspondence:
| | | | | | | |
Collapse
|
11
|
Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results. Hip Int 2014; 24:136-43. [PMID: 24186673 DOI: 10.5301/hipint.5000087] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/04/2013] [Indexed: 02/04/2023]
Abstract
Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have detrimental effects on bone. It is unknown whether serum metal ion levels affect bone density clinically. We compared cementless large femoral head (mean 48 mm) metal-on-metal total hip arthroplasties (M2a-Magnum, Biomet) to cementless 28 mm metal-on-polyethylene total hip arthroplasties (Mallory-Head, Biomet) in a randomised clinical trial. We evaluated periprosthetic acetabular bone density and serum metal ion levels at 1 year postoperatively. Acetabular bone density was analyzed with dual energy x-ray absorptiometry in four horizontal regions of interest in 70 patients. After one year, acetabular bone density decreased (-3.5% to -7.8%) in three of four regions of interest in metal-on-polyethylene patients, but was retained in metal-on-metal patients. Bone density preservation was most pronounced superior to the metal-on-metal cup (+1% versus -3.7%). Serum cobalt, chromium and titanium ion levels were not related to bone density, nor to acetabular inclination or femoral head size. Oxford and Harris hip scores were similar in both groups. Contrary to our hypothesis, acetabular bone density was retained with metal-on-metal total hip arthroplasty, compared to metal-on-polyethylene arthroplasty. Bone preservation was most pronounced in the area superior to the cup. This could be a benefit during future revision surgery.
Collapse
|
12
|
Munro JT, Fernandez JW, Millar JS, Walker CG, Howie DW, Shim VB. Altered load transfer in the pelvis in the presence of periprosthetic osteolysis. J Biomech Eng 2014; 136:1905254. [PMID: 25203813 DOI: 10.1115/1.4028522] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2014] [Accepted: 09/11/2014] [Indexed: 11/08/2022]
Abstract
Periprosthetic osteolysis in the retroacetabular region with cancellous bone loss is a recognized phenomenon in the long-term follow-up of total hip replacement. The effects on load transfer in the presence of defects are less well known. A validated, patient-specific, 3D finite element (FE) model of the pelvis was used to assess changes in load transfer associated with periprosthetic osteolysis adjacent to a cementless total hip arthroplasty (THA) component. The presence of a cancellous defect significantly increased (p < 0.05) von Mises stress in the cortical bone of the pelvis during walking and a fall onto the side. At loads consistent with single leg stance, this was still less than the predicted yield stress for cortical bone. During higher loads associated with a fall onto the side, highest stress concentrations occurred in the superior and inferior pubic rami and in the anterior column of the acetabulum with larger cancellous defects.
Collapse
|
13
|
Streit MR, Weiss S, Andreas F, Bruckner T, Walker T, Kretzer JP, Ewerbeck V, Merle C. 10-year results of the uncemented Allofit press-fit cup in young patients. Acta Orthop 2014; 85:368-74. [PMID: 24875058 PMCID: PMC4105767 DOI: 10.3109/17453674.2014.925351] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. METHODS We examined the clinical and radiographic results of our first 121 consecutive cementless THAs using a cementless, grit-blasted, non-porous, titanium alloy press-fit cup (Allofit; Zimmer Inc., Warsaw, IN) without additional screw fixation in 116 patients. Mean age at surgery was 51 (21-60) years. Mean time of follow-up evaluation was 11 (10-12) years. RESULTS At final follow-up, 8 patients had died (8 hips), and 1 patient (1 hip) was lost to follow-up. 3 hips in 3 patients had undergone acetabular revision, 2 for deep infection and 1 for aseptic acetabular loosening. There were no impending revisions at the most recent follow-up. We did not detect periacetabular osteolysis or loosening on plain radiographs in those hips that were evaluated radiographically (n = 90; 83% of the hips available at a minimum of 10 years). Kaplan-Meier survival analysis using revision of the acetabular component for any reason (including isolated inlay revisions) as endpoint estimated the 11-year survival rate at 98% (95% CI: 92-99). INTERPRETATION Uncemented acetabular fixation using the Allofit press-fit cup without additional screws was excellent into early in the second decade in this young and active patient cohort. The rate of complications related to the liner and to osteolysis was low.
Collapse
Affiliation(s)
| | - Stefan Weiss
- Department of Orthopaedic and Trauma Surgery,Department of Joint Replacement Surgery, ARCUS Kliniken Pforzheim, Pforzheim, Germany
| | | | - Thomas Bruckner
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg
| | | | | | | | | |
Collapse
|
14
|
Finite element analysis of retroacetabular osteolytic defects following total hip replacement. J Biomech 2013; 46:2529-33. [DOI: 10.1016/j.jbiomech.2013.07.038] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Revised: 07/27/2013] [Accepted: 07/31/2013] [Indexed: 11/24/2022]
|
15
|
Proximal tibial bone density is preserved after unicompartmental knee arthroplasty. Clin Orthop Relat Res 2013; 471:1661-9. [PMID: 23325112 PMCID: PMC3613532 DOI: 10.1007/s11999-013-2784-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2012] [Accepted: 01/02/2013] [Indexed: 02/07/2023]
Abstract
BACKGROUND Bone mineral density (BMD) in the proximal tibia decreases after TKA and is believed to be a factor in implant migration and loosening. Unicompartmental knee arthroplasty (UKA) is a less invasive procedure preserving knee compartments unaffected by degeneration. Finite element studies have suggested UKA may preserve BMD and that implants of differing stiffnesses might differentially affect BMD but these notions have not been clinically confirmed. QUESTIONS/PURPOSES We therefore asked whether (1) proximal tibial BMD decreases after UKA, and (2) a cemented metal tibial component with a mobile polyethylene (PE) bearing would have greater BMD loss than a cemented PE tibial component. METHODS We prospectively followed 48 patients who underwent 50 UKAs using one of two implants: one with a cemented metal tibial baseplate and a mobile PE insert (n = 26) and one with a cemented all-PE tibial component (n = 24). In followup we assessed pain and function (Oxford Knee Score, SF-12, The Knee Society Score(©)) and radiographs. BMD changes were assessed using quantitative CT osteodensitometry performed postoperatively and at 1 and 2 years after the index procedure. RESULTS Mean cancellous BMD decreased 1.9% on the medial side and 1.1% on the lateral side. Mean cortical BMD was static, decreasing 0.4% on the medial side and increasing 0.5% on the lateral side. The greatest observed difference between implants for any region was 3.7%. There were no differences in pain or functional outcome scores. CONCLUSIONS BMD was preserved 2 years after UKA with no major differences seen between implant types.
Collapse
|
16
|
García-Rey E, García-Cimbrelo E, Cruz-Pardos A. Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique. Clin Orthop Relat Res 2012; 470:3014-23. [PMID: 22576930 PMCID: PMC3462870 DOI: 10.1007/s11999-012-2381-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Uncemented press-fit cups provide bone fixation in primary THA, but the use of screws is sometimes necessary to achieve primary stability of the socket. However, it is unclear whether and when screws should be used. QUESTION/PURPOSES We analyzed the factors related to screw use with a press-fit uncemented cup and assessed whether screw use is associated with the same rates of loosening and revision as a press-fit technique. METHODS We retrospectively reviewed 248 patients who underwent THA using the same prosthetic design. Eighty-eight hips had screws to achieve primary cup fixation (Group 1), and 189 did not (Group 2). Mean age was 50 years (range, 14-73 years). We analyzed factors related to the patient, acetabular type, and reconstruction of the rotation center of the hip. Minimum followup was 5 years (mean, 8.9 years; range, 5-12 years). RESULTS We found higher screw use in women, patients with less physical activity, Acetabular Types A or C, and a distance from the center of the prosthetic femoral head to the normal center of rotation of more than 3 mm. There were four revisions in Group 1 and five in Group 2. Eight hips had radiographic loosening in Group 1 and nine in Group 2. Cups with a postoperative abduction angle of more than 50° had a higher risk for loosening. CONCLUSIONS Press fit was achieved less frequently in women and patients with Acetabular Types A or C and less physical activity; a closer distance to the normal center of rotation decreased screw use. Screw use to augment fixation achieved survival similar to that of a press-fit cup. LEVEL OF EVIDENCE Level II, prognostic study. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Eduardo García-Rey
- Department of Orthopaedics, Hospital La Paz-Idi Paz, Pº Castellana 261, 28046 Madrid, Spain
| | | | - Ana Cruz-Pardos
- Department of Orthopaedics, Hospital La Paz-Idi Paz, Pº Castellana 261, 28046 Madrid, Spain
| |
Collapse
|
17
|
Beck RT, Illingworth KD, Saleh KJ. Review of periprosthetic osteolysis in total joint arthroplasty: an emphasis on host factors and future directions. J Orthop Res 2012; 30:541-6. [PMID: 21922533 DOI: 10.1002/jor.21554] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2011] [Accepted: 08/24/2011] [Indexed: 02/04/2023]
Abstract
Periprosthetic osteolysis is one of the leading causes of total joint revision procedures. If allowed to progress in the absence of radiographic diagnosis and/or proper medical treatment, osteolysis may result in aseptic loosening yielding failure of the implant and the need for complex revision arthroplasty. The purpose of this review was to assess the current understanding of periprosthetic osteolysis with an emphasis on host factors and future directions. A PubMed search was conducted using the following key words; osteolysis, periprosthetic osteolysis, osteolysis imaging. Pertinent articles, as it pertained to the outline of the review, were selected. Periprosthetic osteolysis stems from numerous risk factors. Osteolysis host characteristic risk factors include gender, body weight, and genetics. Current implant designs have reduced the incidence of this disease; however no current design has been able to replicate the in vivo characteristics and therefore development of wear particles continues to be seen. Advanced methods of imaging diagnosis are on the rise, however early imaging diagnosis is currently ineffective. Pharmacologic intervention appears to be a logical avenue for medical intervention, but no approved drug therapy to prevent or inhibit periprosthetic osteolysis is currently available. Although the rate of periprosthetic osteolysis seems to be decreasing with advances in implant design and increased knowledge of the biological process of wear particle induced osteolysis, the rapid increase in the total number of total joint arthroplasties over the next two decades means that better ways of detecting and treating periprosthetic osteolysis are greatly needed.
Collapse
Affiliation(s)
- Ryan T Beck
- Division of Orthopaedics and Rehabilitation, Department of Surgery, School of Medicine, Southern Illinois University, Springfield 62794-9679, IL
| | | | | |
Collapse
|