1
|
Stefanini N, Morandi Guaitoli M, Pilla F, Faldini C. Managing total hip arthroplasty failure due to ceramic liner fracture and cup perforation: revision with bone grafting through direct anterior approach. BMJ Case Rep 2025; 18:e263855. [PMID: 40287155 DOI: 10.1136/bcr-2024-263855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/29/2025] Open
Abstract
A man in his mid-70s presented with painful right total hip arthroplasty (THA) developed in over 6 months. Clinically, he exhibited significant deambulatory limitations with limb shortening. Radiographs revealed severe wear of the acetabular liner and superior migration of the prosthetic head, leading to metallosis and osteolysis. CT scan confirmed the prosthetic head's penetration into the acetabular component. A revision THA was performed using a direct anterior approach (DAA), including extensive debridement and bone grafting. Postoperatively, the patient showed significant improvements in hip function. At the 6-month follow-up, the patient was pain-free, with no signs of dislocation or implant failure and had returned to normal daily activities. This case highlights the importance of early detection and intervention in managing catastrophic failures of ceramic-on-ceramic THA and underscores the need for meticulous surgical technique, particularly in component positioning, to prevent such complications.
Collapse
Affiliation(s)
- Niccolò Stefanini
- 1st Orthopaedics and Traumatology Department, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | | | - Federico Pilla
- 1st Orthopaedics and Traumatology Department, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Cesare Faldini
- 1st Orthopaedics and Traumatology Department, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- Dipartimento di Scienze Biomediche e Neuromotorie DIBINEM, Bologna, Italy
| |
Collapse
|
2
|
Abdelghafour KM, Jaques A, Shah N. Ceramic-on-ceramic bearings: can we avoid the complications? Long-term outcomes of big head CoC bearings in primary total hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2025; 35:80. [PMID: 40014148 DOI: 10.1007/s00590-025-04199-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2024] [Accepted: 02/15/2025] [Indexed: 02/28/2025]
Abstract
INTRODUCTION Ceramic-on-ceramic (CoC) bearings offer superior wear characteristics and a low coefficient of friction, yet their use is limited due to reported risks of ceramic fractures in the literature. We assessed our series of patients undergoing total hip arthroplasty (THA) with 36 mm CoC bearings. METHODS A Retrospective cohort study of 385 patients (442 hips) who underwent primary THA between 2008 and 2018 was conducted. Twenty-three patients died and 36 patients (38 hips) were lost to follow-up. Data were prospectively collected for 326 patients (381 hips) who had uncemented THA with 36 mm-CoC bearings. Kaplan-Meier analysis was used to assess survival with ceramic fracture or revision due to squeaking as endpoints. Clinical evaluation was done using EQ-5D and Oxford Hip Score (OHS). Incidence of squeaking and ceramic-related complications, dislocation, and infection were recorded. RESULTS Survival of CoC bearings was 100% (95% CI 96.7-100%) at 14 years with ceramic fracture, failure, or revision due to squeaking as the endpoint. Mean OHS was 44.5 (30-48). Occasional squeaking was reported by 28 patients (7.3%), without pain or revision surgery due to squeaking. Squeaking correlated significantly with younger age (< 60 years; P = 0.002). Dislocations occurred in 2 cases (0.5%) and prosthetic joint infection in 1 (0.3%). CONCLUSION THA with CoC bearings using 4th generation BIOLOX delta ceramic heads yielded excellent results at 14 years with a mean follow-up duration of 9.39 years, with no ceramic fractures or squeaking-related revisions. The optimal position of the bearing surface is crucial to mitigate fracture risk, while larger heads reduce dislocation risk. The observed low infection rate may be attributed to reduced biofilm formation on ceramic surfaces.
Collapse
|
3
|
Kim JS, Do MU, Han JB, Lee SM, Moon NH, Suh KT, Shin WC. Similar wear rates of 1st and 2nd generation highly cross-linked polyethylene in primary total hip arthroplasty in patients less than 30 years of age: A minimum 5-year follow-up. Orthop Traumatol Surg Res 2025:104178. [PMID: 39892720 DOI: 10.1016/j.otsr.2025.104178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2024] [Revised: 01/23/2025] [Accepted: 01/28/2025] [Indexed: 02/04/2025]
Abstract
BACKGROUND Younger patients who undergo total hip arthroplasty (THA) often exhibit higher activity and functionality. After the 1 st generation highly cross-linked polyethylene liners (HXLPE), there was advancement with the development of the 2nd generation Vitamin E-infused highly cross-linked polyethylene (VEPE) for polyethylene liners. However, there is limited research comparing these advancements, especially in younger patients. Therefore we did a retrospective comparative study aiming to determine: 1) the wear rate, 2) survivorships of the 1 st and 2nd generations of HXLPE in patients aged <30 years who underwent THA. HYPOTHESIS There is no difference between first and second generation of highly cross-linked polyethylene regarding lower linear and volumetric wear rates. METHODS From 2008-2019, we selected 121 patients, 150 hips of ceramic-polyethylene articulation THA in patients aged <30 years at least 5 years of follow-up. These patients were divided into two groups: 80 hips for 1 st generation HXLPE and 70 hips for 2nd generation VEPE. Both groups had no significant difference regarding age, gender, BMI, and the indication for THA. We compared the wear rate of polyethylene in both groups using PolyWare 7 software and assessed the 5-year THA survival rate. RESULTS In both groups, there was no significant difference in linear and volumetric wear, as measured using PolyWare 7 software. Linear wear rate was 0.0365 ± 0.0187 mm/yr in the 1 st generation HXLPE and 0.0351 ± 0.0171 mm/yr in the 2nd generation VEPE groups. Volumetric wear rate was 20.848 ± 11.319 mm3/yr in the 1 st generation HXLPE and 18.679 ± 7.933 mm3/yr in the 2nd generation VEPE groups. The overall 5-year survival rate post-surgery was 98.7%; no significant difference in the survival rates between the 1 st and 2nd generation groups (98.8 and 98.6% for the 1 st and 2nd generation groups). CONCLUSION In young patients, there was no significant difference in the wear rates between the 1 st generation HXLPE and 2nd generation VEPE when using ceramic-polyethylene bearing surfaces. Based on the analysis of complications, survival rates, and functional scores post-surgery, the results of THA using ceramic-any HXLPE articulation were satisfactory in patients aged <30 years. LEVEL OF EVIDENCE III; Case-control study.
Collapse
Affiliation(s)
- Jung Shin Kim
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do 626-770, 50612, Republic of Korea; Department of Orthopaedic Surgery, Bumin Hospital, 59 Mandeok-daero, Buk-gu, Busan, 46555, Republic of Korea
| | - Min Uk Do
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do 626-770, 50612, Republic of Korea
| | - Jung Bum Han
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do 626-770, 50612, Republic of Korea
| | - Sang-Min Lee
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do 626-770, 50612, Republic of Korea
| | - Nam Hoon Moon
- Department of Orthopaedic Surgery, Pusan National University Hospital, 179 Gudeok-ro, Seo-gu, Busan, 49241, Republic of Korea
| | - Kuen Tak Suh
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do 626-770, 50612, Republic of Korea; Department of Orthopaedic Surgery, Sehung Hospital, 805 Jungang-daero, Busanjin-gu, Busan, 614842, Republic of Korea
| | - Won Chul Shin
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do 626-770, 50612, Republic of Korea.
| |
Collapse
|
4
|
Tashtanov BR, Kirilova IA, Pavlova DV, Pavlov VV. Ceramic-related noise as an adverse outcome in total hip arthroplasty. GENIJ ORTOPEDII 2023; 29:565-573. [DOI: 10.18019/1028-4427-2023-29-5-565-573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Introduction Ceramic hip replacement bearings have shown to be low wearing and biocompatible. The last two generations of Biolox Forte and Biolox Delta ceramics have have established themselves as durable bearings. However, squeaking and noise from ceramic bearing THRs is well recognised in the 21st century.The objective was to explore the problem of noise in the ceramic bearing of THA based on the analysis of the foreign and Russian literature.Material and methods In presented the analysis of Foreign and Russian literature searches for the review were produced according to PRISMA recommendations using PubMed, Scopus, Google Scholar, eLibrary. MINOR was used to assess the methodological quality of articles.Results and Discussion Noise in ceramics is observed in 37.7 %. There are many theories on the origin and mechanism of noise including liner impingement and loading, film disruption, third body, microseparation and resonance. However, there is still no consensus on what is noise in the ceramic bearing and how to solve this problem.Conclusion Literature review of ceramic bearing indicated enough unanswered questions. The noise may play a role as a predictor of improper use of endoprosthesis with accumulated database resulting in better understanding of the phenomenon, methods of the correction and timely prevention of ceramic breakage.
Collapse
Affiliation(s)
- B. R. Tashtanov
- Novosibirsk Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan
| | - I. A. Kirilova
- Novosibirsk Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan
| | | | - V. V. Pavlov
- Novosibirsk Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan
| |
Collapse
|
5
|
The occurrence of squeaking under wear testing standards for ceramic on ceramic total hip replacements. J Mech Behav Biomed Mater 2023; 138:105616. [PMID: 36565691 DOI: 10.1016/j.jmbbm.2022.105616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 11/22/2022] [Accepted: 12/06/2022] [Indexed: 12/23/2022]
Abstract
Ceramic on ceramic total hip replacement clinical reports may on occasion note a noise or squeaking. There is much debate on whether this is an actual concern, but some medical centres want to avoid any possible negative impact on the patients' wellbeing due to the noise generated. The aim of this study was to determine what sound frequencies can be picked up from hip testing standards for ceramic on ceramic under different lubrication conditions. The ISO-14242-1 (35° cup angle) and ISO-14242-4 (55° cup angle with a 4 mm translational mismatch) standards were used for testing with dry, water and serum lubrication conditions up to 10000 cycles. No sound was detected for water and serum conditions under standard walking (ISO-14242-1) testing. An audible noise with a frequency range of 0.4-0.8 kHz was picked up within 600 cycles under water and edge loading (ISO-14242-4) conditions. All dry testing produced a high pitch squeak when the frequency was higher than 2 kHz. One sample under dry edge loading conditions had an audible noise of 0.8 kHz, considered not as squeaking, as it was not high pitch. Dry testing for both, standard walking (ISO-14242-1) and edge loading (ISO-14242-4) conditions, which resulted in a high pitch noise, had a frequency range of 2-8 kHz and 5-9 kHz respectively. One sample tested with edge loading and serum produced a faint squeak noise after 6000 cycles with a frequency of 7 kHz. Edge loading due to ISO-14242-4 conditions had an increased torque which may be playing a role in increased friction leading to noise. Edge loading conditions were more prone to the generation of audible noise and squeaking whilst under lubricated conditions.
Collapse
|
6
|
Liao Y, Cao L, Wang Q, Li S, Lin Z, Li W, Zhang P, Yu C. Enhanced tribological properties of
PEEK
‐based composite coatings reinforced by
PTFE
and graphite. J Appl Polym Sci 2022. [DOI: 10.1002/app.51878] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Yuwen Liao
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
| | - Lin Cao
- Shaoguan Research Institute of Jinan University Jinan University Guangzhou China
| | - Qiwei Wang
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
| | - Shuangjian Li
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
- Shaoguan Research Institute of Jinan University Jinan University Guangzhou China
| | - Zhidan Lin
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
| | - Wei Li
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
| | - Peng Zhang
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
- Shaoguan Research Institute of Jinan University Jinan University Guangzhou China
| | - Chuanyong Yu
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials Jinan University Guangzhou China
- Shaoguan Research Institute of Jinan University Jinan University Guangzhou China
| |
Collapse
|
7
|
Fang Y, Shang X. Comparison of Ceramic-on-Ceramic vs. Ceramic-on-Polyethylene for Primary Total Hip Arthroplasty: A Meta-Analysis of 15 Randomized Trials. Front Surg 2021; 8:751121. [PMID: 34977138 PMCID: PMC8716688 DOI: 10.3389/fsurg.2021.751121] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Accepted: 11/15/2021] [Indexed: 12/02/2022] Open
Abstract
Objective: This meta-analysis aimed to compare ceramic-on-ceramic (COC) components and ceramic-on-polyethylene (COP) components during total hip arthroplasty (THA). Settings: A meta-analysis of randomized controlled trials (RCTs) comparing COC and COP during primary THA was conducted. Electronic searches were current to March 2021. Participants: Trials were included for meta-analysis if they compared at least the bearing surfaces of COC and COP for patients undergoing primary THA and if they reported the outcomes of THA after a certain period of follow-up and only RCTs in English were included. Primary and Secondary Outcome Measures: The primary endpoints consist of audible noise, prosthesis fracture, and revision. Secondary endpoints include dislocation, deep infection, osteolysis, and prosthesis loosening. Extracted data were statistically analyzed with the Stata11.0. Results: A total of 15 RCTs containing 2,702 patients (2,813 hips) were included in this study. The audible noise [odds ratio (OR) = 5.919; 95% CI: 2.043, 17.146; p ≤ 0.001] and prosthesis fracture (OR = 35.768; 95% CI: 8.957, 142.836; p = 0.001) were significantly higher in the COC group. Hip function, revision rate, dislocation rate, deep infection rate, osteolysis rate, and prosthesis loosening rate were comparable between these two groups, while the wear rate was higher in the COP group. Conclusion: This study indicated comparable outcomes of COC and COP bearing surfaces in primary THA; high-quality RCTs with a long-term follow-up are still urgently needed to provide more evidence on the optimal bearing surfaces in primary THA.
Collapse
Affiliation(s)
- Yan Fang
- Department of Anesthesiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaobin Shang
- Department of Orthopaedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
8
|
Akoh CC, Chen J, Adams SB. Total Ankle Total Talus Replacement Using a 3D Printed Talus Component: A Case Report. J Foot Ankle Surg 2021; 59:1306-1312. [PMID: 32958354 DOI: 10.1053/j.jfas.2020.08.013] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 08/11/2020] [Accepted: 08/11/2020] [Indexed: 02/03/2023]
Abstract
The 3D custom total talus replacement is a novel treatment for avascular necrosis of the talus. However, patients who require a total talus replacement often have concomitant degenerative changes to the tibiotalar, subtalar, or talonavicular joints. The combined 3D custom total ankle-total talus replacement (TATTR) is used for patients with an unreconstructable talus and adjacent tibial plafond involvement. The goal of performing a TATTR is to provide pain relief, retain motion at the tibiotalar joint, maintain or improve the patient's functional status, and minimize limb shortening. TATTR is made possible by 3D printing. The advent of 3D printing has allowed for the accurate recreation of the native talar anatomy with a talar dome that can be matched to a total ankle replacement polyethylene bearing. In this article, we will discuss a case of talar avascular necrosis treated with a combined TATTR and review the current literature for TATTR.
Collapse
Affiliation(s)
- Craig C Akoh
- Foot and Ankle Fellow, Duke University Medical Center, Durham, NC.
| | - Jie Chen
- Foot and Ankle Fellow, Duke University Medical Center, Durham, NC
| | - Samuel B Adams
- Assistant Professor, Duke University Medical Center, Durham, NC
| |
Collapse
|
9
|
Chatelet JC, Fessy MH, Saffarini M, Machenaud A, Jacquot L. Articular Noise After THA Using Delta CoC Bearings Has Little Impact on Quality of Life. J Arthroplasty 2021; 36:1678-1687. [PMID: 33293173 DOI: 10.1016/j.arth.2020.11.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/30/2020] [Accepted: 11/06/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND To report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL). METHODS From a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors. RESULTS The 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030). CONCLUSION Of 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.
Collapse
Affiliation(s)
- Jean-Christophe Chatelet
- Centre de Chirurgie Orthopédique du Beaujolais, Ramsay Santé, Arnas, France; Artro Institute, Lyon, France
| | - Michel-Henri Fessy
- Artro Institute, Lyon, France; Hospices Civils de Lyon, Centre Hospitalier Lyon-Sud, Service de Chirurgie Orthopédique et Traumatologique, Pierre-Bénite Cedex, France; IFSTTAR, Laboratoire de Biomécanique et Mécanique des Chocs, Bron, France
| | | | - Alain Machenaud
- Artro Institute, Lyon, France; Department of Orthopaedic Surgery, Clinique d'Argonay, Ramsay Santé, Annecy, France
| | | | - Laurent Jacquot
- Artro Institute, Lyon, France; Department of Orthopaedic Surgery, Clinique d'Argonay, Ramsay Santé, Annecy, France
| |
Collapse
|
10
|
Bellity J, Elkaïm M, Hannouche D, Nizard R. Arthroscopic evaluation and treatment of a squeaking hip. A case report. BMC Musculoskelet Disord 2020; 21:805. [PMID: 33272241 PMCID: PMC7713320 DOI: 10.1186/s12891-020-03817-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 11/22/2020] [Indexed: 11/22/2022] Open
Abstract
Background Squeaking of ceramic-on-ceramic total hip arthroplasty is an unexpected complication which occurs in 1- 30% of patients. Revision surgery is required in 0.2% of the cases, when a ceramic fracture is suspected, or in case of severe malposition of the implants, subluxation, or impingement. Hip arthroscopy may be a useful diagnostic and therapeutic option in squeaking hips. Case presentation A patient presenting with a pain-free squeaking underwent hip arthroscopy to examine the sliding surfaces and the rim of the acetabulum, and to search for signs of impingement. Thorough lavage and debridement of hip synovitis and fibrous tissue was performed. The squeaking noise immediately disappeared after the surgery. The patient was allowed to fully weight bear as tolerated with 2 crutches for 2 weeks. Two years after the arthroscopy, the patient remained symptom-free. Conclusions The potential reasons for hip squeaking in our patient are discussed. Hip arthroscopy may prove useful as a diagnostic and therapeutic option for some patients presenting with a squeaking ceramic-on ceramic hip replacement.
Collapse
Affiliation(s)
- Jonathan Bellity
- Department of Orthopaedic Surgery, Lariboisière, Hospital, Paris 7 University, Paris, France
| | - Marc Elkaïm
- Department of Orthopaedic Surgery, Lariboisière, Hospital, Paris 7 University, Paris, France
| | - Didier Hannouche
- Department of Orthopaedic Surgery, Lariboisière, Hospital, Paris 7 University, Paris, France. .,Department of Orthopaedic Surgery, Geneva University Hospitals & Faculty of Medicine, Avenue Gabrielle Perret Gentil 4, 1205, Geneva, Switzerland.
| | - Rémy Nizard
- Department of Orthopaedic Surgery, Lariboisière, Hospital, Paris 7 University, Paris, France
| |
Collapse
|
11
|
Davis ET, Pagkalos J, Kopjar B. Effect of Bearing Surface on Survival of Cementless and Hybrid Total Hip Arthroplasty: Study of Data in the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. JB JS Open Access 2020; 5:e0075. [PMID: 33123668 PMCID: PMC7418917 DOI: 10.2106/jbjs.oa.19.00075] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Background Modern bearing surface options have increased implant survivorship after total hip arthroplasty (THA). We utilized data from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to analyze implant survivorship after THAs with uncemented acetabular components with different bearing combinations. Methods Polyethylene (PE) manufacturing properties supplied by the manufacturers were used to subdivide the NJR data set into cross-linked PE (XLPE) and conventional PE groups. Overall and cause-specific revisions for various bearing combinations were analyzed using Kaplan-Meier and multivariate Cox proportional hazard regression survival analyses. Results Of 420,339 primary THAs, 8,025 were revised during an average follow-up period of 4.4 years (maximum, 13.3 years). In the Cox regression model with metal on conventional PE as the reference, the lowest risk of revision for any reason was for ceramicized metal on XLPE (hazard ratio [HR] = 0.58, 95% confidence interval [CI] = 0.48, 0.71), followed by ceramic on XLPE (HR = 0.66, 95% CI = 0.60, 0.72), ceramic on PE (HR = 0.74, 95% CI = 0.66, 0.82), ceramic on ceramic (HR = 0.77, 95% CI = 0.72, 0.82), and metal on XLPE (HR = 0.81, 95% CI = 0.76, 0.87). A similar pattern was observed when patients under the age of 55 years were analyzed independently. Younger age, male sex, and cementless stem fixation were associated with a higher risk of revision. Conclusions In a fully adjusted model, ceramicized metal on XLPE and ceramic on XLPE were associated with the lowest risk of revision for any reason. This finding was sustained when patients under the age of 55 years were analyzed independently. On the basis of the NJR data set, use of XLPE markedly reduces the risk of revision. Level of Evidence Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Edward T Davis
- The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, United Kingdom.,Institute of Inflammation and Ageing, University of Birmingham, Birmingham, United Kingdom
| | - Joseph Pagkalos
- The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, United Kingdom
| | - Branko Kopjar
- The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, United Kingdom.,School of Public Health, University of Washington, Seattle, Washington
| |
Collapse
|
12
|
Yoo SJ, Rho YH, Nam KW. Letter to Editor Concerning "Total Hip Arthroplasty Using Ceramic-on-ceramic Bearing Surfaces: Long-term Assessment of Squeaking Sounds" by Kim et al. (Hip Pelvis. 2018;30(1):18-22, http://dx.doi.org/10.5371/hp.2018.30.1.18). Hip Pelvis 2019; 31:242-243. [PMID: 31824880 PMCID: PMC6892901 DOI: 10.5371/hp.2019.31.4.242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Accepted: 06/26/2019] [Indexed: 11/24/2022] Open
Affiliation(s)
- Seung Jin Yoo
- Department of Orthopaedic Surgery, Jeju National University Hospital, Jeju, Korea
| | - Young-Ho Rho
- Department of Orthopaedic Surgery, Jeju National University Hospital, Jeju, Korea
| | - Kwang Woo Nam
- Department of Orthopaedic Surgery, Jeju National University Hospital, Jeju, Korea
| |
Collapse
|
13
|
Konan S, Alazzawi S, Yoon BH, Cha YH, Koo KH. A focused update on preventing ceramic fractures in hip arthroplasty. Bone Joint J 2019; 101-B:897-901. [DOI: 10.1302/0301-620x.101b8.bjj-2019-0309.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Ceramic bearings have several desirable properties, such as resistance to wear, hardness, and biocompatibility, that favour it as an articulating surface in hip arthroplasty. However, ceramic fracture remains a concern. We have reviewed the contemporary literature, addressing the factors that can influence the incidence of ceramic bearing surface fracture. Cite this article: Bone Joint J 2019;101-B:897–901.
Collapse
Affiliation(s)
- S. Konan
- Princess Grace Hospital, London, UK
| | - S. Alazzawi
- Orthopaedic Department, University of British Columbia Hospital and Vancouver General Hospital, Vancouver, Canada
| | - B-H. Yoon
- Inje University Seoul Paik Hospital, Seoul, South Korea
| | - Y-H. Cha
- Orthopedic Surgery, Eulji University Hospital, Daejeon, South Korea
| | - K-H. Koo
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, South Korea
| |
Collapse
|
14
|
Kim SC, Lim YW, Jo WL, Park HW, Han SB, Kwon SY, Kim YS. Fourth-generation ceramic-on-ceramic THA results in improvements in midterm outcomes compared to third-generation THA but does not resolve noise problems: a cohort study of a single-hip system. BMC Musculoskelet Disord 2019; 20:263. [PMID: 31142296 PMCID: PMC6542023 DOI: 10.1186/s12891-019-2641-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2017] [Accepted: 05/17/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Using data from the Korean Hip Registry, we aimed to investigate mid-term clinical and radiographic outcomes, including the prevalence of periprosthetic joint infection (PJI), osteolysis, and component loosening or dislocation, and to analyze the incidence of bearing-related complications following modern ceramic-on-ceramic (COC) total hip arthroplasty (THA) using a single cementless hip system. METHODS Four hundred eighty-two patients (602 hips) who underwent Forte or Delta COC THAs with a single hip system and had a minimum 5-year follow-up were identified. The sample included 243 (50.4%) women and 239 (49.6%) men with a mean age of 50.6 years (range: 18-83 years). The Forte group comprised 310 hips, and the Delta group comprised 292 hips. The mean follow-up was 6.1 years (range: 5-10.2 years). RESULTS Cup orientation did not differ between groups. No hip had a PJI or osteolysis in either group. All acetabular components and all but two femoral components (in the Delta group) were well fixed. Dislocations occurred in six (1.9%) hips in the Forte group and one (0.3%) hip in the Delta group (p = 0.124). A total of nine (1.5%) revisions were performed. The 5-year survival rates for all-cause revisions were 98.4 and 98.6%, respectively. One (0.3%) ceramic head fracture occurred in the Forte group. Sixteen (5%) hips exhibited clicking and 6 (2%) hips had squeaking in the Forte group; 16 (6%) hips exhibited clicking and 5 (2%) hips had squeaking in the Delta group. Multiple regression analysis revealed that noise generation was unassociated with any factor. CONCLUSIONS From the Korean Hip Registry data, THA with modern ceramic bearings showed encouraging results, with lower risks of PJI, osteolysis, and component loosening. In particular, Delta COC THA resulted in no PJI or ceramic fracture and had a reduced dislocation risk. However, associated noise remains a concern.
Collapse
Affiliation(s)
- Seung-Chan Kim
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Young-Wook Lim
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea
| | - Woo-Lam Jo
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea
| | - Hyun-Woo Park
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea
| | - Sung-Bin Han
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Soon-Yong Kwon
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Yong-Sik Kim
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea.
| |
Collapse
|
15
|
Luo Y, Sun XF, Chen J, Cui W, Wang T. Could larger diameter of 4th generation ceramic bearing increase the rate of squeaking after THA?: A retrospective study. Medicine (Baltimore) 2018; 97:e13977. [PMID: 30593224 PMCID: PMC6314778 DOI: 10.1097/md.0000000000013977] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The present study aimed to evaluate the clinical outcomes and bearing-specific complications in a single center of 135 delta ceramic-on-ceramic (COC) total hip arthroplasties (THAs) and explore the occurrence rate of squeaking in 4th generation COC THAs and collate the risk factors for squeaking.We retrospectively analyzed consecutive cohorts of 127 patients (135 hips) who had primary THA with delta COC bearings in our hospital between April 2010 and April 2012. Preoperative Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and University of California Los Angeles (UCLA) activity score were evaluated preoperatively and postoperatively. We also evaluated ceramic fracture, squeak, mid-term results, and survival.In our study, the final patient final follow-up date was July 31, 2016. The mean preoperative HHS improved from 39.5 to 93.1 points. Mean preoperative UCLA score was 3.2 points, improving to 8.2 points. The mean preoperative total WOMAC score was 55.5 points and the mean total WOMAC score was 13.3 points at the final follow-up. The Kaplan-Meier survival plot of revision for any reason as the end point was 98.5% and survival with ceramic fracture as the end point was 99.2% at a mean of 70 months' follow-up. One post-operative ceramic liner rim fracture occurred at 50 months after surgery. Thirteen of the 135 hips produced a squeaking sound. There were no significant differences in gender (P = .56), age (P = .20), body mass index (BMI) (P = .11), diagnosis (P = .46), cup inclination (P = .36), or cup anteversion (P = 1.0) between the squeaking and non-squeaking groups. However, the incidence of squeaking in the 36 mm COC femoral head bearings was higher than in the 28 mm size (13.6% vs 2.1%, P = .033).The 4th generation COC bearing performed well and provides an encouraging rate of survival with no osteolysis or loosening. However, we found that a squeaking sound associated with use of the delta ceramic occurred at a rate of 9.6%, with the larger-diameter heads having significantly higher incidence.
Collapse
Affiliation(s)
- Yuan Luo
- Department of Orthopedic Surgery, The First People's Hospital of Taicang
| | - Xue-Feng Sun
- Department of Orthopedic Surgery, Suzhou Xiangcheng People's Hospital
| | - Jin Chen
- Department of Orthopedic Surgery, Suzhou Xiangcheng People's Hospital
| | - Wei Cui
- Department of Orthopedic Surgery, Suzhou Xiangcheng People's Hospital
| | - Tao Wang
- Department of Orthopedic Surgery, Affiliated Hospital of Jiangnan University, Wuxi, China
| |
Collapse
|
16
|
The Ideal Total Hip Replacement Bearing Surface in the Young Patient: A Prospective Randomized Trial Comparing Alumina Ceramic-On-Ceramic With Ceramic-On-Conventional Polyethylene: 15-Year Follow-Up. J Arthroplasty 2018; 33:1752-1756. [PMID: 29422350 DOI: 10.1016/j.arth.2017.11.066] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 11/23/2017] [Accepted: 11/28/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The optimum bearing surface for total hip arthroplasty remains debatable. We have previously published our outcome at 10 years and this represents the 15-year follow-up. METHODS A total of 58 hips (in 57 patients with a mean age of 42 years) were randomized to receive either ceramic-on-ceramic (CoC) or ceramic-on-polyethylene (CoP) total hip arthroplasty. We prospectively followed for survivorship, functional outcomes (using the Harris Hip Score and the St Michael's Hip Score [SMH]), and radiological outcomes. RESULTS At a minimum of 15 years, 3 patients had died, but not been revised. Seven were lost to follow-up. Five cases from the CoP group were revised (4 for polyethylene wear and osteolysis). Four from the CoC were revised; one each for head fracture, instability, infection, and trunnionosis. Both groups showed statistically significant improvements in Harris Hip Score scores and SMH functional scores, with no difference between the 2 bearings. For the CoP group, there was an improvement from 15.6 to 21.5 in the SMH and from 48.8 to 88.7 (P > .05); and for CoC, this improvement was 15.8 to 23.5 and 50.3 to 94.6 (P > .05), respectively. Mean wear rate of the polyethylene was 0.092 mm/y and for the CoC was 0.018 mm/y. Two patients in the CoC group had evidence of acetabular osteolysis vs 3 in the CoP. Six patients had femoral osteolysis in the CoC group and 12 in the CoP group. CONCLUSION Survivorship and function of the 2 bearing groups remains comparable; while the polyethylene wear and osteolysis may represent issues in the future.
Collapse
|
17
|
Zhao CC, Qu GX, Yan SG, Cai XZ. Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review. J Orthop Surg Res 2018; 13:133. [PMID: 29859126 PMCID: PMC5984797 DOI: 10.1186/s13018-018-0841-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 05/21/2018] [Indexed: 02/06/2023] Open
Abstract
Background Postoperative squeaking in patients who applied the fourth-generation ceramic bearing in primary hip replacement has not been reported systematically; we aim to study the squeaking incidence in the fourth-generation ceramic bearing and related risk factors for squeaking, and we also attempt to explore the relationship between squeaking and prosthetic brands. Methods The PubMed, Embase, and Cochrane library were searched, and 14 articles were finally included. Patients’ demographic data, surgical-related information, and prosthesis data were extracted. The occurrence rate of squeaking was calculated by meta-analysis, and subgroup analysis was performed based on prosthetic brands and follow-up time. Regression analysis was further applied to investigate the relationship between various risk factors and squeaking. Results The squeaking incidence in patients with the fourth-generation ceramic bearing was 3%. Age, gender, body mass index, and abduction and anteversion angles of acetabular cup might have no influence on squeaking. The squeaking incidence was significantly high with the presence of Delta Motion cup (DePuy, Warsaw, Indiana) and Secure-Fit stem (Stryker, Kalamazoo, MI), and the overall incidence of DePuy femoral stem was relatively small except for the Summit femoral stem. And there was no significant difference of squeaking incidence between less than 5-year and more than or equal to 5-year follow-up subgroups. Conclusions In our study, squeaking in the fourth-generation ceramic bearing occurred at a rate of 3%; occurrence rate was high when the Delta Motion cup was applied. We hope for more relevant researches to focus on this issue. Electronic supplementary material The online version of this article (10.1186/s13018-018-0841-y) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Chen-Chen Zhao
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China.,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China
| | - Guo-Xin Qu
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China.,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China
| | - Shi-Gui Yan
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China.,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China
| | - Xun-Zi Cai
- Department of Orthopaedic Surgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Jiefang Road 88, Hangzhou, 310009, China. .,Orthopaedic Research Laboratory, Zhejiang University, Jiefang Road 88, Hangzhou, China.
| |
Collapse
|
18
|
Abstract
Total hip arthroplasty (THA) is widely considered one of the most successful surgical procedures in orthopaedics. It is associated with high satisfaction rates and significant improvements in quality of life following surgery. On the other hand, the main cause of late revision is osteolysis and wear, often a result of failure of bearing surfaces.Currently, several options are available to the surgeon when choosing the bearing surface in THA (ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoPE), metal-on-polyethylene (MoPE)), each with advantages and drawbacks.Very few studies have directly compared the various combinations of bearings at long-term follow-up. Randomized controlled trials show similar short- to mid-term survivorship among the best performing bearing surfaces (CoC, CoXLPE and MoXLPE). Selection of the bearing surface is often 'experience-based' rather than 'evidence-based'.The aim of this paper is therefore to evaluate the main advantages and drawbacks of various types of tribology in THA, while providing practical suggestions for the surgeon on the most suitable bearing surface option for each patient. Cite this article: EFORT Open Rev 2018;3 DOI: 10.1302/2058-5241.3.180300.
Collapse
Affiliation(s)
- Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Italy
| | | |
Collapse
|
19
|
Kim MW, Kim SM, Chung YY. Total Hip Arthroplasty Using Ceramic-on-ceramic Bearing Surfaces: Long-term Assessment of Squeaking Sounds. Hip Pelvis 2018; 30:18-22. [PMID: 29564293 PMCID: PMC5861021 DOI: 10.5371/hp.2018.30.1.18] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 01/12/2018] [Accepted: 01/13/2018] [Indexed: 12/12/2022] Open
Abstract
Purpose This study was performed to characterize the natural history of squeaking sounds that occur following total hip arthroplasty (THA) using ceramic-on-ceramic bearing surfaces and its potential correlation with clinical and/or radiological results. Materials and Methods This study included 47 patients who underwent THA between April 1999 and April 2005, and had at least 10 years of follow up from the time of the operation. Squeaking sounds were detected in 10 out of the 47 cases (21.3%). Squeaking-associated factors (i.e., cause, time of onset, inducing motions, and continuity of the sound) were assessed. Results Squeaking sounds: i) were detected an average of 46.2 months after operation, ii) occurred more frequently in patients with a high body mass index (BMI) compared to those with low BMI, and iii) most frequently detected when deep flexion of hip joint followed extension. In all 10 cases, the squeaking sound remained through the follow up period; 6 cases experienced no change in frequency and pitch, 4 cases experienced a decrease in frequency and pitch over time. The cause(s) of changes to squeaking sounds could not be determined. Conclusion The frequency and pitch of the squeaking sounds changed over time in a subset of patients. The squeaking sound did not appear to correlate with clinical results or survival of the prosthesis.
Collapse
Affiliation(s)
- Min Wook Kim
- Department of Orthopaedic Surgery, Kwangju Christian Hospital, Gwangju, Korea
| | - Sang Min Kim
- Department of Orthopaedic Surgery, Kwangju Christian Hospital, Gwangju, Korea
| | - Young Yool Chung
- Department of Orthopaedic Surgery, Kwangju Christian Hospital, Gwangju, Korea
| |
Collapse
|
20
|
Hannouche D, Zingg M, Miozzari H, Nizard R, Lübbeke A. Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: What is the evidence? EFORT Open Rev 2018; 3:7-14. [PMID: 29657840 PMCID: PMC5890134 DOI: 10.1302/2058-5241.3.170034] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Wear, corrosion and periprosthetic osteolysis are important causes of failure in joint arthroplasty, especially in young patients. Ceramic bearings, developed 40 years ago, are an increasingly popular choice in hip arthroplasty. New manufacturing procedures have increased the strength and reliability of ceramic materials and reduced the risk of complications. In recent decades, ceramics made of pure alumina have continuously improved, resulting in a surgical-grade material that fulfills clinical requirements. Despite the track record of safety and long-term results, third-generation pure alumina ceramics are being replaced in clinical practice by alumina matrix composites, which are composed of alumina and zirconium. In this review, the characteristics of both materials are discussed, and the long-term results with third-generation alumina-on-alumina bearings and the associated complications are compared with those of other available ceramics.
Cite this article: EFORT Open Rev 2018;3:7-14. DOI: 10.1302/2058-5241.3.170034
Collapse
Affiliation(s)
- Didier Hannouche
- Department of Orthopaedic Surgery and Traumatology, Geneva University Hospital, Switzerland
| | - Matthieu Zingg
- Department of Orthopaedic Surgery and Traumatology, Geneva University Hospital, Switzerland
| | - Hermes Miozzari
- Department of Orthopaedic Surgery and Traumatology, Geneva University Hospital, Switzerland
| | - Remy Nizard
- Department of Orthopaedic Surgery, AP-HP, Hôpital Lariboisière, Paris University, Paris, France
| | - Anne Lübbeke
- Department of Orthopaedic Surgery and Traumatology, Geneva University Hospital, Switzerland
| |
Collapse
|
21
|
Bedard NA, Burnett RA, DeMik DE, Gao Y, Liu SS, Callaghan JJ. Are Trends in Total Hip Arthroplasty Bearing Surface Continuing to Change? 2007-2015 Usage in a Large Database Cohort. J Arthroplasty 2017; 32:3777-3781. [PMID: 28887024 DOI: 10.1016/j.arth.2017.07.044] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 07/25/2017] [Accepted: 07/26/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Bearing surface issues related to trunnionosis or metal-on-metal (MoM) articulations have likely impacted recent trends in bearing surface choice. The purpose of this study is to evaluate trends in total hip arthroplasty (THA) bearing surface use, including 2015 data, with respect to the date of operation and patient demographics. METHODS The Humana dataset was reviewed from 2007 through 2015 to analyze bearing surface usage in primary THA. Four bearing surface types were identified by International Classification of Disease, 10th Revision codes and trended throughout the years: metal-on-polyethylene (MoP), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and MoM. Prevalence was analyzed as a function of age and sex. RESULTS Of the 28,504 primary THA procedures, the most commonly used bearing was MoP (46.1%), followed by CoP (33.2%), MoM (17.1%), and ceramic-on-ceramic (3.6%). The use of CoP bearings significantly increased from 6.4% in 2007 to 52.0% in 2015, while MoM bearings decreased during this period. MoP bearings decreased over 2012-2015 (P < .001). CoP usage decreased with age, while MoP bearings increased with a transition occurring at 65-69 years of age. Women were more likely to receive MoP bearings (odds ratio [OR] 1.2), while men were more likely to receive MoM and CoP bearings (OR 1.1). Multivariate logistic regression showed age to be an independent predictor of bearing surface choice with patients 65 and older more likely to receive MoP bearings (OR 3.2). CONCLUSION Bearing surface choice in primary THA has changed tremendously from 2007 to 2015. MoM bearing use has decreased as a result of adverse effects. Age continues to remain a significant factor in bearing surface choice.
Collapse
Affiliation(s)
- Nicholas A Bedard
- Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, Iowa
| | - Robert A Burnett
- Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, Iowa
| | - David E DeMik
- Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, Iowa
| | - Yubo Gao
- Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, Iowa
| | - Steve S Liu
- Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, Iowa
| | - John J Callaghan
- Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, Iowa
| |
Collapse
|
22
|
Schmidt-Braekling T, Renner L, Mintz DN, Waldstein W, Endo Y, Boettner F. Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study. J Arthroplasty 2017; 32:1314-1317. [PMID: 27876256 DOI: 10.1016/j.arth.2016.10.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Revised: 09/24/2016] [Accepted: 10/09/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. METHODS We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. RESULTS Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). CONCLUSION The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture.
Collapse
Affiliation(s)
- Tom Schmidt-Braekling
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York; Department of Orthopedics and Tumor Orthopedics, University of Muenster, Muenster, Germany
| | - Lisa Renner
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| | - Douglas N Mintz
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Wenzel Waldstein
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York; Department of Orthopedics, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Yoshimi Endo
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Friedrich Boettner
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| |
Collapse
|
23
|
Wu GL, Zhu W, Zhao Y, Ma Q, Weng XS. Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty. Chin Med J (Engl) 2017; 129:1861-6. [PMID: 27453238 PMCID: PMC4976577 DOI: 10.4103/0366-6999.186654] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Objective: The present study aimed to review the characteristics and influencing factors of squeaking after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and to analyze the possible mechanisms of the audible noise. Data Sources: The data analyzed in this review were based on articles from PubMed and Web of Science. Study Selection: The articles selected for review were original articles and reviews found based on the following search terms: “total hip arthroplasty”, “ceramic-on-ceramic”, “hip squeaking”, and “hip noise.” Results: The mechanism of the squeaking remains unknown. The possible explanations included stripe wear, edge loading, a third body, fracture of the ceramic liner, and resonance of the prosthesis components. Squeaking occurrence is influenced by patient, surgical, and implant factors. Conclusions: Most studies indicated that squeaking after CoC THA was the consequence of increasing wear or impingement, caused by prosthesis design, patient characteristics, or surgical factors. However, as conflicts exist among different articles, the major reasons for the squeaking remain to be identified.
Collapse
Affiliation(s)
- Guo-Liang Wu
- Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Wei Zhu
- Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Yan Zhao
- Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Qi Ma
- Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Xi-Sheng Weng
- Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| |
Collapse
|
24
|
Higuchi Y, Hasegawa Y, Komatsu D, Seki T, Ishiguro N. Survivorship Between 2 Different Ceramic-on-Ceramic Total Hip Arthroplasty With or Without a Metal-Backed Titanium Sleeve Bearing: A 5- to 14-Year Follow-Up Study. J Arthroplasty 2017; 32:155-160. [PMID: 27452136 DOI: 10.1016/j.arth.2016.06.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 05/31/2016] [Accepted: 06/06/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of the study was to compare the clinical and radiographic results of consecutive ceramic-on-ceramic bearings with and without a metal-backed titanium sleeve in patients undergoing total hip arthroplasty. METHODS Eighty-five patients (64 women and 21 men; average age 55.2 years) were included in the A group without sleeve while 147 patients (116 women and 31 men; average age 54.2 years) were included in the B group with sleeve. Clinical and radiologic measurements at follow-up (range, 5-14 years; average, 8.1 years) were analyzed. RESULTS The mean latest postoperative Harris Hip Score was 89.1 for patients from both groups. One joint (1.2%) in the A group displayed ceramic liner fracture, while no incidences of liner fracture occurred in the B group. Audible squeaking was observed in 1 joint (1.2%) in the A group and 1 (0.7%) in the B group. The mean annual liner rate of wear was 0.0049 and 0.0046 mm/y for the A group and B group, respectively. Three joints in the A group (3.5%) required revision total hip arthroplasty because of individual episodes of aseptic cup loosening, ceramic liner fracture, and infection. One joint in the B group (0.7%) required revision because of progressive osteolysis of the proximal femur. Ten-year Kaplan-Meier survivorship, based on an end point of component loosening and bearing failure, was 97.6% for the A group and 99.3% for the B group. CONCLUSION There were no clinical, radiographic, or survivorship differences between groups.
Collapse
Affiliation(s)
- Yoshitoshi Higuchi
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Yukiharu Hasegawa
- Department of Hip and Knee Reconstructive Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Daigo Komatsu
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Taisuke Seki
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Naoki Ishiguro
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
25
|
Carnes KJ, Odum SM, Troyer JL, Fehring TK. Cost Analysis of Ceramic Heads in Primary Total Hip Arthroplasty. J Bone Joint Surg Am 2016; 98:1794-1800. [PMID: 27807111 DOI: 10.2106/jbjs.15.00831] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The advent of adverse local tissue reactions seen in metal-on-metal bearings, and the recent recognition of trunnionosis, have led many surgeons to recommend ceramic-on-polyethylene articulations for primary total hip arthroplasty. However, to our knowledge, there has been little research that has considered whether the increased cost of ceramic provides enough benefit over cobalt-chromium to justify its use. The primary purpose of this study was to compare the cost-effectiveness of ceramic-on-polyethylene implants and metal-on-polyethylene implants in patients undergoing total hip arthroplasty. METHODS Markov decision modeling was used to determine the ceramic-on-polyethylene implant revision rate necessary to be cost-effective compared with the revision rate of metal-on-polyethylene implants across a range of patient ages and implant costs. A different set of Markov models was used to estimate the national cost burden of choosing ceramic-on-polyethylene implants over metal-on-polyethylene implants for primary total hip arthroplasties. The Premier Research Database was used to identify 20,398 patients who in 2012 were ≥45 years of age and underwent a total hip arthroplasty with either a ceramic-on-polyethylene implant or a metal-on-polyethylene implant. RESULTS The cost-effectiveness of ceramic heads is highly dependent on the cost differential between ceramic and metal femoral heads and the age of the patient. At a cost differential of $325, ceramic-on-polyethylene bearings are cost-effective for patients <85 years of age. At a cost differential of $600, it is cost-effective to utilize ceramic-on-polyethylene bearings in patients <65 years of age, and, at a differential of $1,003, ceramic-on-polyethylene bearings are not cost-effective at any age. CONCLUSIONS The ability to recoup the initial increased expenditure of ceramic heads through a diminished lifetime revision cost is dependent on the price premium for ceramic and the age of the patient. A wholesale switch to ceramic bearings regardless of age or cost differential may result in an economic burden to the health system. LEVEL OF EVIDENCE Economic and decision analysis, Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Keith J Carnes
- College of Health and Human Services (K.J.C.) and Belk College of Business (J.L.T.), University of North Carolina at Charlotte, Charlotte, North Carolina
| | - Susan M Odum
- OrthoCarolina Research Institute, Charlotte, North Carolina
| | - Jennifer L Troyer
- College of Health and Human Services (K.J.C.) and Belk College of Business (J.L.T.), University of North Carolina at Charlotte, Charlotte, North Carolina
| | | |
Collapse
|
26
|
Primary total hip arthroplasty using 3rd generation ceramic-on-ceramic articulation. Hip Int 2016; 26:468-473. [PMID: 27198969 DOI: 10.5301/hipint.5000375] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/09/2016] [Indexed: 02/04/2023]
Abstract
PURPOSE Ceramic-on-ceramic (CoC) is currently a popular bearing combination in young patients in primary total hip arthroplasty (THA). The purpose of this study was to evaluate clinical and radiographic results and complications of cementless THA with 3rd generation CoC articulation. MATERIALS AND METHODS From April 2001 to January 2008, 310 primary THAs were performed in 300 patients using 3rd generation CoC articulation. The mean follow-up period was 8.9 years and the mean age at index surgery was 54.6 years. Patient clinical outcome was evaluated with the Harris Hip Score. Radiographic evaluations was performed to analyse osteolysis, implant fixation and loosening. RESULTS Mean Harris Hip Score at last follow-up was 95.4 (76-100). Radiographic analysis demonstrated no evidence of stem or cup loosening and there were no cases of osteolysis. Ceramic wear was not detectable on the plain radiograph. Complications requiring revision occurred in 12 cases; 2 ceramic head fractures, 4 dislocations, 2 deep infections and 4 cases of periprosthetic fracture. The cohort had an overall revision rate of 3.9%. CONCLUSIONS Clinical outcomes using cementless THA with 3rd generation CoC articulation were satisfactory. Although the mechanical properties of ceramic materials have improved, there are still problems such as ceramic fracture and squeaking. More clinical study and investigation for alternative bearing are necessary to reduce complications. 4th generation CoC or ceramic on cross linked polyethylene may address some of these issues.
Collapse
|
27
|
Wang T, Sun JY, Zhao XJ, Liu Y, Yin HB. Ceramic-on-ceramic bearings total hip arthroplasty in young patients. Arthroplast Today 2016; 2:205-209. [PMID: 28326429 PMCID: PMC5247519 DOI: 10.1016/j.artd.2016.04.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Revised: 04/27/2016] [Accepted: 04/28/2016] [Indexed: 12/12/2022] Open
Abstract
Background The results of ceramic-on-ceramic (CoC) total hip arthroplasty (THA) in younger patients were not univocal. This study aims to evaluate the results of CoC bearing THA in patients younger than 50 years. Methods A total of 90 younger patients performed CoC THAs during March 2003 and May 2008 were included in this study. Hip function and activity were evaluated with Harris hip score and University of California Los Angeles activity score. We had discussed survival rates, radiological findings of component loosening or osteolysis, and ceramic-related complications in these patients. Results The mean Harris hip score increased from 46.3 ± 12.0 points (range, 28-70 points) before surgery to 92.5 ± 5.6 points (range, 78-100 points) at the final follow-up. The mean preoperative University of California Los Angeles activity score was 4.2 ± 1.1 points (range, 2-6 points), which improved to a mean of 7.2 ± 1.3 points (range, 4-10 points). At the time of the last follow-up, there was found to be 1 occurrence of hip dislocation, 1 squeaking, and 2 “sandwich” ceramic liners fractured during normal activity of daily living. No hips showed osteolysis or required revision for aseptic loosening. Kaplan-Meier survivorship with revision due to loosening or osteolysis was 100% and with revision due to ceramic fracture was 97.3% (95% confidence interval, 93.7%-100%) at a mean of 9.4 years. Conclusions This study with the use of CoC bearings THAs in younger patients have shown promising results and higher rate of survivorship without evidence of osteolysis.
Collapse
Affiliation(s)
- Tao Wang
- Department of Orthopedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Jun-Ying Sun
- Department of Orthopedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Xi-Jiang Zhao
- Department of Orthopedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China; Department of Orthopedic Surgery, The Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, China
| | - Yong Liu
- Department of Orthopedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Hai-Bo Yin
- Department of Orthopedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China
| |
Collapse
|
28
|
Grübl AJ. CORR Insights(®): oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study. Clin Orthop Relat Res 2015; 473:3846-8. [PMID: 26358757 PMCID: PMC4626514 DOI: 10.1007/s11999-015-4560-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Accepted: 09/03/2015] [Indexed: 01/31/2023]
|
29
|
Levy YD, Munir S, Donohoo S, Walter WL. Review on squeaking hips. World J Orthop 2015; 6:812-820. [PMID: 26601063 PMCID: PMC4644869 DOI: 10.5312/wjo.v6.i10.812] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Revised: 08/21/2015] [Accepted: 09/28/2015] [Indexed: 02/06/2023] Open
Abstract
Squeaking is a well-recognized complication for hard-on-hard bearings. The nature of squeaking is not yet completely understood however it is considered a multifactorial phenomenon. Patient, implant, and surgical factors play a role in squeaking. It is believed that mechanisms damaging the fluid film lubrication in which these bearings function optimally have a critical role. Such mechanisms include edge loading, stripe wear, impingement, third body particles and ceramic fracture. The resonance of metallic parts can produce noise in the human audible range hence the implant metallurgic composition and design may play a role. Implant positioning can facilitate impingement and edge loading enhancing the occurrence of squeaking. The recent introduction of large heads (> 36 mm) 4th generation ceramic-on-ceramic bearing may accentuate the conditions facilitating noise formation; however the current literature is insufficient. Clinically, squeaking may manifest in extreme hip positions or during normal gait cycle however it is rarely associated with pain. Evaluations of patients with squeaking include clinical and radiographic assessments. Computer tomography is recommended as it can better reveal ceramic breakage and implant malposition. The treatments for most squeaking patients include reassurance and activity modification. However for some, noise can be a problem, requiring further surgical intervention. In the occurrence of ceramic fracture, implant failure, extreme components malposition, instability and impingement, surgery should be advised. This review will aim to discuss the current literature regarding squeaking.
Collapse
|
30
|
Endo Y, Renner L, Schmidt-Braekling T, Mintz DN, Boettner F. Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT. Skeletal Radiol 2015; 44:1189-92. [PMID: 25744811 DOI: 10.1007/s00256-015-2122-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2014] [Revised: 01/25/2015] [Accepted: 02/15/2015] [Indexed: 02/02/2023]
Abstract
Fracture of a ceramic liner of a total hip arthroplasty is rare and is radiographically occult if not displaced. We report on two patients in whom ceramic liner fracture was radiographically occult but was diagnosed on subsequent CT scan through appropriate windowing.
Collapse
Affiliation(s)
- Yoshimi Endo
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | | | | | | | | |
Collapse
|
31
|
Wyles CC, Jimenez-Almonte JH, Murad MH, Norambuena-Morales GA, Cabanela ME, Sierra RJ, Trousdale RT. There Are No Differences in Short- to Mid-term Survivorship Among Total Hip-bearing Surface Options: A Network Meta-analysis. Clin Orthop Relat Res 2015; 473:2031-41. [PMID: 25516002 PMCID: PMC4419002 DOI: 10.1007/s11999-014-4065-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Accepted: 11/14/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Total hip arthroplasty (THA) is increasingly being performed in patients with long life expectancies and active lifestyles. Newer implant bearing surfaces, with superior wear characteristics, often are used in this cohort with the goal of improving longevity of the prosthesis, but comparisons across the numerous available bearing surfaces are limited, so the surgeon and patient may have difficulty deciding which implants to use. QUESTIONS/PURPOSES The purpose of this study was to answer the following question: Is there a short- to mid-term survivorship difference between common THA bearings used in patients younger than age 65 years? METHODS We conducted a systematic review to identify randomized clinical trials (RCTs) published after 2000 that reported survivorship of ceramic-on-ceramic (CoC), ceramic-on-highly crosslinked polyethylene (CoPxl), or metal-on-highly crosslinked polyethylene (MoPxl) bearings. To qualify for our review, RCTs had to have a minimum 2-year followup and study patients were required to have an average age younger than 65 years. Direct-comparison meta-analysis and network meta-analysis were performed to combine direct and indirect evidence. RESULTS Direct-comparison meta-analysis found no differences among the bearing surfaces in terms of the risk of revision; this approach demonstrated a risk ratio for revision of 0.65 (95% confidence interval [CI], 0.19-2.23; p = 0.50) between CoC and CoPxl and a risk ratio for revision of 0.40 (95% CI, 0.06-2.63; p = 0.34) between CoC and MoPxl. Network meta-analysis (with post hoc modification) likewise found no differences in survivorship across the three implant types, demonstrating the following probabilities of most effective implant with 95% credible intervals (CrI): CoC = 64.6% (0%-100%); CoPxl = 24.9% (0%-100%); and MoPxl = 9.9% (0%-100%). The CrIs ranged from 0% to 100% for all three bearing surfaces. Direct-comparison meta-analysis allowed for pooling of five RCTs, including 779 THAs, whereas network meta-analysis (before post hoc analysis) enabled pooling of 18 RCTs, including 2599 THAs. CONCLUSIONS Current published evidence does not support survivorship differences among commonly used bearing surfaces in patients younger than age 65 years undergoing THA at short- to mid-term followup. Long-term RCT data will be needed to determine if a survivorship benefit is realized in younger, more active patients over time. LEVEL OF EVIDENCE Level I, therapeutic study.
Collapse
Affiliation(s)
- Cody C. Wyles
- />Mayo Medical School, Mayo Clinic, Rochester, MN USA
| | | | - Mohammad H. Murad
- />Mayo Clinic Division of Preventive Medicine, Mayo Clinic, Rochester, MN USA
| | | | - Miguel E. Cabanela
- />Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| | - Rafael J. Sierra
- />Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| | - Robert T. Trousdale
- />Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| |
Collapse
|
32
|
Abstract
Wear and corrosion in joint arthroplasty are important causes of failure. From the standpoint of current clinical importance, there are four main categories of wear and tribocorrosion: polyethylene wear, ceramic-on-ceramic (CoC) bearing wear, metal-on-metal (MoM) bearing wear, and taper tribocorrosion. Recently, problems with wear in the knee have become less prominent as have many issues with hip polyethylene (PE) bearings resulting from the success of crosslinked PE. However, MoM articulations and taper tribocorrosion have been associated with soft tissue inflammatory responses, and as a result, they have become prominent clinical concerns. WHERE ARE WE NOW?: For PE wear in the hip, several advances include improved locking mechanisms and data supporting highly crosslinked polyethylenes (HXLPE). Edge-loading in CoC articulations can contribute to stripe wear and subsequent squeaking. For MoM articulations, the relationship of wear-to-edge loading, sensitivity to component positioning, typical soft tissue response, and use of imaging is increasingly understood. Taper tribocorrosion (from femoral head-neck junctions and other modular elements) and associated soft tissue inflammatory responses appear to be serious clinical issues that are not fully understood. WHERE DO WE NEED TO GO?: In the knee, clinical concerns remain with the efficacy of HXLPE, modular connections, and metal allergies. For PE wear in the hip, concerns remain regarding how to increase crosslinking of PE while minimizing PE fractures. With CoC articulations, questions remain on how to prevent noises, chipping, and impingement and if enhanced designs can contribute to improved results. For MoM articulations, we need to improve imaging tests for soft tissue reactions, determine best practices in terms of monitoring protocols, and better define if, how, and when to act on serum metal levels. For taper tribocorrosion, we need to use modularity wisely and also understand how to improve tapers and materials in the future. For patients at risk for tribocorrosion, we need to define realistic diagnostic and monitoring protocols. We also need to enhance revision methods, and the threshold of acceptable soft tissue damage, to minimize complications associated with soft tissue damage such as hip instability. HOW DO WE GET THERE?: HXLPE and other bearing surfaces will likely continue to be refined. We need to develop tapers with more resistance to tribocorrosion through improved understanding of the manufacturing process and ongoing engineering improvements. Revision procedures for wear and tribocorrosion can be enhanced by determining when partial component retention is appropriate and how best to manage soft tissue damage. For CoC articulations, enhanced designs are required to minimize noises, chipping, and impingement. Importantly, we must continue to promote and analyze joint replacement registries to identify early failures and analyze long-term successes.
Collapse
|
33
|
Lee TH, Moon YW, Lim SJ, Park YS. Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients. Hip Pelvis 2014; 26:92-8. [PMID: 27536565 PMCID: PMC4971122 DOI: 10.5371/hp.2014.26.2.92] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 05/08/2014] [Accepted: 05/30/2014] [Indexed: 12/12/2022] Open
Abstract
Purpose The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramic-on-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. Materials and Methods We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and risk factors and 25 studies in Western patients were analyzed for squeaking incidence. The data collected were: patient factors, surgical factors and implantation factors. Results The overall incidence of hip squeaking was 2.7% in Asians and 3.1% in Westerners. This difference was not statistically significant. The only significant risk factor was an increase in the acetabular cup abduction angle. Of the factors, the cup abduction angle was the only significant risk factor for the occurrence rate of squeaking, and the occurrence rate tended to increase with increasing angle. Conclusion The incidence of squeaking in Asians after primary ceramic-on-ceramic THA is 2.7% and is similar to that in Westerners. The increased cup abduction angle is associated with squeaking; therefore, surgeons should be careful not to implant the cup at a too steep abduction angle.
Collapse
Affiliation(s)
- Tae-Hun Lee
- Department of Orthopedic Surgery, Pohang St. Mary's Hospital, Pohang, Korea
| | - Young-Wan Moon
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung-Jae Lim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|