1
|
Steiner Q, Wang A, Slane L, Hetzel S, DeWall R, Thelen D, Lee K. Ultrasound quantitative characterization of tendinopathy with shear wave elastography in an ex vivo porcine tendon model. Eur Radiol Exp 2025; 9:33. [PMID: 40111644 PMCID: PMC11926283 DOI: 10.1186/s41747-024-00542-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Accepted: 12/04/2024] [Indexed: 03/22/2025] Open
Abstract
BACKGROUND Early detection and treatment of tendinopathy may prevent progression to partial tears or complete rupture. Shear wave elastography (SWE) may help address the need for better tendon pathology characterization. This study aimed to quantify the effect of structural damage in an ex vivo animal tendinopathy model using SWE. METHODS Forty-two porcine flexor tendons were injected with a 0.05-mL bolus of 1.5% collagenase solution to induce focal structural damage without surface tears. Control tendons were injected with saline (n = 42). Twenty-one tendons from each group were incubated at 37 °C for 3.5 h, while the remaining 21 from each group were incubated for 7 h. Each group was then divided into three groups of seven, and tendon incisions were made at 25%, 50%, and 75% of the tendon thickness. Tendons were mechanically stretched axially during simultaneous collection of SWE at the injection site. RESULTS There were significant differences in shear wave speed (SWS) (saline > collagenase) at 3.5-h incubation (p < 0.001) and 7-h incubation (p < 0.001). Additionally, there was a significant difference in SWS between tendons cut at 25% and tendons cut at 50% and 75% (p = 0.040 and p = 0.001, respectively). Collagenase-treated tendons ruptured at a lower force than saline-treated tendons at both incubation times (both p < 0.001) when controlling for cut depth. Tendons treated with collagenase ruptured at a lower force than the saline control group at each cut thickness (all p < 0.001) controlling for incubation time. CONCLUSION In a controlled ex vivo porcine model, SWE can be used to detect structural damage associated with tendinopathy. RELEVANCE STATEMENT Shear wave elastography can be used to show differences in abnormal tendons that may be translatable to clinical use as an adjunctive measure of tendon elasticity and injury. KEY POINTS Tendon abnormality was quantitatively characterized using shear wave elastography in an ex vivo porcine experimental model. Shear wave speed was an accurate imaging biomarker for tendon health. Shear wave elastography was effective at detecting the extent of tendon damage. Tendons with decreased shear wave speed measurements rupture at smaller applied mechanical force.
Collapse
Affiliation(s)
- Quinn Steiner
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, USA
| | - Albert Wang
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Laura Slane
- Department of Mechanical Engineering, University of Rochester, Rochester, NY, USA
| | - Scott Hetzel
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, USA
| | | | - Darryl Thelen
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Kenneth Lee
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
2
|
Albarova-Corral I, Segovia-Burillo J, Malo-Urriés M, Ríos-Asín I, Asín J, Castillo-Mateo J, Gracia-Tabuenca Z, Morales-Hernández M. A New Quantitative Tool for the Ultrasonographic Assessment of Tendons: A Reliability and Validity Study on the Patellar Tendon. Diagnostics (Basel) 2024; 14:1067. [PMID: 38893594 PMCID: PMC11171978 DOI: 10.3390/diagnostics14111067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 05/15/2024] [Accepted: 05/16/2024] [Indexed: 06/21/2024] Open
Abstract
Ultrasound is widely used for tendon assessment due to its safety, affordability, and portability, but its subjective nature poses challenges. This study aimed to develop a new quantitative analysis tool based on artificial intelligence to identify statistical patterns of healthy and pathological tendons. Furthermore, we aimed to validate this new tool by comparing it to experts' subjective assessments. A pilot database including healthy controls and patients with patellar tendinopathy was constructed, involving 14 participants with asymptomatic (n = 7) and symptomatic (n = 7) patellar tendons. Ultrasonographic images were assessed twice, utilizing both the new quantitative tool and the subjective scoring method applied by an expert across five regions of interest. The database contained 61 variables per image. The robustness of the clinical and quantitative assessments was tested via reliability analyses. Lastly, the prediction accuracy of the quantitative features was tested via cross-validated generalized linear mixed-effects logistic regressions. These analyses showed high reliability for quantitative variables related to "Bone" and "Quality", with ICCs above 0.75. The ICCs for "Edges" and "Thickness" varied but mostly exceeded 0.75. The results of this study show that certain quantitative variables are capable of predicting an expert's subjective assessment with generally high cross-validated AUC scores. A new quantitative tool for the ultrasonographic assessment of the tendon was designed. This system is shown to be a reliable and valid method for evaluating the patellar tendon structure.
Collapse
Affiliation(s)
- Isabel Albarova-Corral
- PhysiUZerapy Health Sciences Research Group, Department of Physiatry and Nursing, University of Zaragoza, 50009 Zaragoza, Spain
| | - José Segovia-Burillo
- Fluid Mechanics, Instituto de Investigación en Ingeniería de Aragón (I3A), University of Zaragoza, 50018 Zaragoza, Spain
| | - Miguel Malo-Urriés
- PhysiUZerapy Health Sciences Research Group, Department of Physiatry and Nursing, University of Zaragoza, 50009 Zaragoza, Spain
| | - Izarbe Ríos-Asín
- PhysiUZerapy Health Sciences Research Group, Department of Physiatry and Nursing, University of Zaragoza, 50009 Zaragoza, Spain
| | - Jesús Asín
- Modelos Estocásticos Research Group, Department of Statistical Methods, University of Zaragoza, 50009 Zaragoza, Spain
| | - Jorge Castillo-Mateo
- Modelos Estocásticos Research Group, Department of Statistical Methods, University of Zaragoza, 50009 Zaragoza, Spain
| | - Zeus Gracia-Tabuenca
- Modelos Estocásticos Research Group, Department of Statistical Methods, University of Zaragoza, 50009 Zaragoza, Spain
| | - Mario Morales-Hernández
- Fluid Mechanics, Instituto de Investigación en Ingeniería de Aragón (I3A), University of Zaragoza, 50018 Zaragoza, Spain
| |
Collapse
|
3
|
Quilling GM, Lee KS, Ebben B. Shear wave elastography imaging in a porcine tendinopathy model. Skeletal Radiol 2022; 51:2167-2173. [PMID: 35639127 DOI: 10.1007/s00256-022-04073-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 05/10/2022] [Accepted: 05/11/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To quantify the effect of structural damage in an ex vivo animal tendinopathy model using shear wave elastography (SWE). MATERIALS AND METHODS Sixteen porcine flexor tendons were injected with a 0.05 mL bolus of 1.5% collagenase solution to induce focal structural damage without surfacing tears. Control tendons were injected with saline (n = 16). Eight tendons from each group were incubated at 37 °C for 3.5 h while the remaining 8 from each group were incubated for 7 h. Tendons were mechanically stretched to 0% and 1% strain. Simultaneously, SWE was acquired proximal to, at, and distal to the injection site using a clinical ultrasound scanner. RESULTS There were significant differences in SWS (saline > collagenase) at 1% strain and 7-h incubation for all three locations (PROX p = 0.0031, ROI p = 0.001, DIST p = 0.0043). There were also significant differences at 0% strain and 7 h, but only at (p = 0.0005), and distal to (p = 0.0035), the injection site. No statistically significant differences were observed for 3.5-h incubation, at 0% or 1% strain. CONCLUSIONS Collagenase-mediated structural damage does appear to convey decreased tissue elasticity on SWE when ex vivo tendons are incubated for 7 h. These findings suggest that SWE may be a useful tool for predicting ultimate tissue strength in tendinopathic tissues. Pull-to-failure testing should be performed in the future and are expected to show that tendons with decreased SWS, and, therefore, decreased elasticity, rupture at lower pulls forces.
Collapse
Affiliation(s)
- Grant M Quilling
- School of Medicine and Public Health, University of Wisconsin, 750 Highland Ave, Madison, WI, 53726, USA
| | - Kenneth S Lee
- Department of Radiology, University of Wisconsin Hospitals and Clinics, 621 Science Drive, Madison, WI, 53711, USA.
| | - Beau Ebben
- Department of Radiology, University of Wisconsin Hospitals and Clinics, 621 Science Drive, Madison, WI, 53711, USA
| |
Collapse
|
4
|
Savva C, Karagiannis C, Korakakis V, Efstathiou M. The analgesic effect of joint mobilization and manipulation in tendinopathy: a narrative review. J Man Manip Ther 2021; 29:276-287. [PMID: 33769226 PMCID: PMC8491707 DOI: 10.1080/10669817.2021.1904348] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Objective: To summarize the available literature with regards to the potential analgesic effect and mechanism of joint mobilization and manipulation in tendinopathy. Results: The effect of these techniques in rotator cuff tendinopathy and lateral elbow tendinopathy, applied alone, compared to a placebo intervention or along with other interventions has been reported in some randomized controlled trials which have been scrutinized in systematic reviews. Due to the small randomized controlled trials and other methodological limitations of the evidence base, including short-term follow-ups, small sample size and lack of homogenous samples further studies are needed. Literature in other tendinopathies such as medial elbow tendinopathy, de Quervain's disease and Achilles tendinopathy is limited since the analgesic effect of these techniques has been identified in few case series and reports. Therefore, the low methodological quality renders caution in the generalization of findings in clinical practice. Studies on the analgesic mechanism of these techniques highlight the activation of the descending inhibitory pain mechanism and sympathoexcitation although this area needs further investigation. Conclusion: Study suggests that joint mobilization and manipulation may be a potential contributor in the management of tendinopathy as a pre-conditioning process prior to formal exercise loading rehabilitation or other proven effective treatment approaches.
Collapse
Affiliation(s)
- Christos Savva
- Department of Health Science, European University, Nicosia, Cyprus
| | | | | | - Michalis Efstathiou
- Department of Life and Health Sciences, University of Nicosia, Nicosia, Cyprus
| |
Collapse
|
5
|
Proceed with Caution: Mouse Deep Digit Flexor Tendon Injury Model. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2021; 9:e3359. [PMID: 33552814 PMCID: PMC7859083 DOI: 10.1097/gox.0000000000003359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 11/17/2020] [Indexed: 11/26/2022]
Abstract
Supplemental Digital Content is available in the text. The purpose of this study was to determine the feasibility of using mouse models for translational study of flexor tendon repair and reconstruction.
Collapse
|
6
|
Han SH, Kim HK, Ahn JH, Lee DH, Baek M, Ye G, Lee JM, Min K, Oh C, Lee S. A Protocol to Acquire the Degenerative Tenocyte from Humans. J Vis Exp 2018. [PMID: 29939181 DOI: 10.3791/57634] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Tendinopathy, a painful condition that develops in response to tendon degeneration, is on the rise in the developed world due to increasing physical activity and longer life expectancy. Despite its increasing prevalence, the underlying pathogenesis still remains unclear, and treatment is generally symptomatic. Recently, numerous therapeutic options, including growth factors, stem cells, and gene therapy, were investigated in hopes of enhancing the healing potency of the degenerative tendon. However, the majority of these research studies were conducted only on animal models or healthy human tenocytes. Despite some studies using pathological tenocytes, to the best of our knowledge there is currently no protocol describing how to obtain human degenerative tenocytes. The aim of this study is to describe a standard protocol for acquiring human degenerative tenocytes. Initially, the tendon tissue was harvested from a patient with lateral epicondylitis during surgery. Then biopsy samples were taken from the extensor carpi radialis brevis tendon corresponding to structural changes observed at the time of surgery. All of the harvested tendons appeared to be dull, gray, friable, and edematous, which made them visually distinct from the healthy ones. Tenocytes were cultured and used for experiments. Meanwhile, half of the harvested tissues were analyzed histologically, and it was shown that they shared the same key features of tendinopathy (angiofibroblastic dysplasia or hyperplasia). A secondary analysis by immunocytochemistry confirmed that the cultured cells were tenocytes with the majority of the cells having positive stains for mohawk and tenomodulin proteins. The qualities of the degenerative nature of tenocytes were then determined by comparing the cells with the healthy control using a proliferation assay or qRT-PCR. The degenerative tenocyte displayed a higher proliferation rate and similar gene expression patterns of tendinopathy that matched previous reports. Overall, this new protocol might provide a useful tool for future studies of tendinopathy.
Collapse
Affiliation(s)
- Soo-Hong Han
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine
| | - Hyung Kyung Kim
- Department of Pathology, Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine
| | - Jong-Ho Ahn
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine
| | - Dong Hyeon Lee
- Department of Physiology, CHA University School of Medicine
| | - Minjung Baek
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine
| | - Geunhee Ye
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine
| | - Joong-Myung Lee
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine
| | - Kyunghoon Min
- Department of Rehabilitation, CHA Bundang Medical Center, CHA University School of Medicine
| | - Chihoon Oh
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine
| | - Soonchul Lee
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine;
| |
Collapse
|