1
|
Mahanty B, Verma PK, Mohapatra PK. Evidence of Eu(III) Dual Binding in a PVC‐Based Electrochemical Sensor with
N,N,N’,N’
‐Tetrapentyl Diglycolamide (TPDGA) as the Ionophore: Potentiometric and Luminescence studies. ChemistrySelect 2023. [DOI: 10.1002/slct.202204681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023]
Affiliation(s)
- Bholanath Mahanty
- Radiochemistry division Bhabha Atomic Research Centre Trombay, Mumbai 400085 India
| | - Parveen K. Verma
- Radiochemistry division Bhabha Atomic Research Centre Trombay, Mumbai 400085 India
| | | |
Collapse
|
2
|
Zahran EM, Fatila EM, Chen CH, Flood AH, Bachas LG. Cyanostar: C–H Hydrogen Bonding Neutral Carrier Scaffold for Anion-Selective Sensors. Anal Chem 2018; 90:1925-1933. [DOI: 10.1021/acs.analchem.7b04008] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Elsayed M. Zahran
- Department
of Chemistry, University of Miami, Coral Gables, Florida 33126, United States
- Applied
Organic Chemistry Department, National Research Centre, Cairo, 12622, Egypt
| | - Elisabeth M. Fatila
- Department
of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Chun-Hsing Chen
- Department
of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Amar H. Flood
- Department
of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Leonidas G. Bachas
- Department
of Chemistry, University of Miami, Coral Gables, Florida 33126, United States
| |
Collapse
|
3
|
Wojciechowski K. A New Device for Simultaneous Measurements of Dynamic Interfacial Tension and Electrical Potential Difference. CHEM LETT 2012. [DOI: 10.1246/cl.2012.1099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
4
|
Wojciechowski K. Hydration energy or hydration force? Origin of ion-specificity in ion selective electrodes. Curr Opin Colloid Interface Sci 2011. [DOI: 10.1016/j.cocis.2011.05.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
5
|
Saraswathyamma B, Pająk M, Radecki J, Maes W, Dehaen W, Girish Kumar K, Radecka H. PVC Supported Liquid Membrane and Carbon Paste Potentiometric Sensors Incorporating a Mn(III)-Porphyrin for the Direct Determination of Undissociated Paracetamol. ELECTROANAL 2008. [DOI: 10.1002/elan.200804280] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
6
|
Gupta VK, Singh AK, Gupta B. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples. Anal Bioanal Chem 2008; 390:2171-81. [DOI: 10.1007/s00216-008-1936-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2007] [Revised: 02/04/2008] [Accepted: 02/05/2008] [Indexed: 11/28/2022]
|
7
|
Radecka H, Grzybowska I, Radecki J, Jakubowski P, Loteran S, Orlewska C, Maes W, Dehaen W. Salicylate Determination in Human Plasma by ISEs Incorporating Mn(III)‐Porphyrine and Zn(II)‐Dipyrromethene. ANAL LETT 2007. [DOI: 10.1080/00032710600964767] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
8
|
Corroles as receptors in liquid membrane electrodes and their potentiometric response towards salicylic acid. Electrochim Acta 2006. [DOI: 10.1016/j.electacta.2005.02.152] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
9
|
Rayana MCB, Burnett RW, Covington AK, D'Orazio P, Fogh-Andersen N, Jacobs E, Kataky R, Külpmann WR, Kuwa K, Larsson L, Lewenstam A, Maas AHJ, Mager G, Naskalski JW, Okorodudu AO, Ritter C, St John A. Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): IFCC Scientific Division, Committee on Point of Care Testing and Working Group on Selective Electrodes. Clin Chem Lab Med 2006; 44:346-52. [PMID: 16519610 DOI: 10.1515/cclm.2006.060] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractThe proposed recommendation for measuring and reporting chloride in undiluted plasma or blood by ion-selective electrodes (ISEs) will provide results that are identical to chloride concentrations measured by coulometry for standardized normal plasma or blood samples. It is applicable to all current ISEs dedicated to chloride measurement in undiluted samples that meet the requirements. However, in samples with reduced water concentration, results by coulometry are lower than by ion-selective electrode due to volume displacement. The quantity measured by this standardized ISE procedure is called the ionized chloride concentration. It may be clinically more relevant than the chloride concentration as determined by coulometry, photometry or by ISE after dilution of the sample.
Collapse
Affiliation(s)
- Mohammed C Ben Rayana
- Laboratory of Clinical Chemistry, National Institute of Nutrition, Bab Saadoun, Tunis, Tunisia
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Radecka H, Tohda K, Umezawa Y. Optimum concentration of anionic sites in lipophilic macrocyclic pentaamine-based liquid membranes for potentiometric responses to anionic analytes. ANAL SCI 2001; 17:1221-4. [PMID: 11990601 DOI: 10.2116/analsci.17.1221] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- H Radecka
- Polish Academy of Sciences, Institute of Animal Reproduction and Food Science, Division of Food Research, Olsztyn
| | | | | |
Collapse
|