1
|
Tian Y, Liu J, Qiao J, Ge F, Yang Y, Zhang Q. Advancements in electrochemical sensingTechnology for Heavy Metal Ions Detection. Food Chem X 2025; 25:102204. [PMID: 39911752 PMCID: PMC11795542 DOI: 10.1016/j.fochx.2025.102204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2024] [Revised: 01/13/2025] [Accepted: 01/18/2025] [Indexed: 02/07/2025] Open
Abstract
Most heavy metal ions are carcinogenic and non-biodegradable, posing threats to ecological balance and human health in trace amount. Therefore, there is a pressing demand for rapid and dependable detection technologies. Electrochemical sensing technology distinguishes itself with its ease of use and swiftness, rendering it perfect for the expeditious detection of heavy metal elements. This review examines various electrochemical detection techniques for on-site real-time monitoring of heavy metal ions. Advanced methods using innovative electrochemical sensor technologies are explored, highlighting the importance of sensing strategies for the quick and easy monitoring of metal levels in different environments. Additionally, the role of nanotechnology and electrochemical techniques in enhancing the sensitivity and selectivity of sensors for better detection of heavy metals is discussed. Finally, the future direction of sensor development is addressed, focusing on integrating new materials and technologies to improve the performance of sensor in environmental monitoring, food safety and public health.
Collapse
Affiliation(s)
- Yu Tian
- Shanxi Kunming Tobacco Co., Ltd., Taiyuan 030012, China
| | - Jinli Liu
- School of Life Science, Shanxi University, Taiyuan 030006, China
| | - Jiali Qiao
- School of Life Science, Shanxi University, Taiyuan 030006, China
| | - Fuguo Ge
- School of Life Science, Shanxi University, Taiyuan 030006, China
| | - Yukun Yang
- School of Life Science, Shanxi University, Taiyuan 030006, China
| | - Qi Zhang
- Shanxi Kunming Tobacco Co., Ltd., Taiyuan 030012, China
| |
Collapse
|
2
|
Karagözlü M, Aşır S, Abu Shama N, Göktürk I, Yılmaz F, Türkmen D, Denizli A, Özgören M. Development of Molecularly Imprinted Magnetic Amino Acid-Based Nanoparticles for Voltammetric Analysis of Lead Ions in Honey. Polymers (Basel) 2024; 16:1782. [PMID: 39000638 PMCID: PMC11244471 DOI: 10.3390/polym16131782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 06/14/2024] [Accepted: 06/20/2024] [Indexed: 07/17/2024] Open
Abstract
Lead (Pb) is a hazardous metal that poses a significant threat to both the environment and human health. The presence of Pb in food products such as honey can pose a significant risk to human health and is therefore important to detect and monitor. In this study, we propose a voltammetric detection method using molecularly imprinted polymer (MIP) electrodes to detect Pb (II) ions in honey. Pb (II) ion-imprinted amino acid-based nanoparticles with magnetic properties on a carbon paste electrode (MIP-CPE) were designed to have high sensitivity and selectivity towards Pb (II) ions in the honey sample. Zetasizer measurements, electron spin resonance, and scanning electron microscopy were used to characterize magnetic polymeric nanoparticles. The results showed that the voltammetric detection method using MIP-CPE was able to accurately detect Pb (II) ions in honey samples with a low detection limit. The proposed method offers a simple, rapid, cost-effective solution for detecting Pb (II) ions in honey. It could potentially be applied to other food products to ensure their safety for human consumption. The MIP-CPE sensor was designed to have high sensitivity and selectivity towards Pb (II) ions in the honey sample. The results showed that the technique was able to deliver highly sensitive results since seven different concentrations were prepared and detected to obtain an R2 of 0.9954, in addition to a low detection limit (LOD) of 0.0912 µM and a low quantification limit (LOQ) of 0.276 µM. Importantly, the analysis revealed no trace of Pb (II) ions in the honey samples obtained from Cyprus.
Collapse
Affiliation(s)
- Mehmet Karagözlü
- Department of Food Engineering, Faculty of Agriculture, Near East University, Nicosia 99138, Cyprus;
- Research Center for Science, Technology and Engineering (BILTEM), Near East University, Nicosia 99138, Cyprus
| | - Süleyman Aşır
- Research Center for Science, Technology and Engineering (BILTEM), Near East University, Nicosia 99138, Cyprus
- Department of Biomedical Engineering, Faculty of Engineering, Near East University, Nicosia 99138, Cyprus
| | - Nemah Abu Shama
- Department of Analytical Chemistry, Faculty of Pharmacy, Near East University, Nicosia 99138, Cyprus
| | - Ilgım Göktürk
- Department of Chemistry, Hacettepe University Ankara, Ankara 06800, Turkey
| | - Fatma Yılmaz
- Department of Chemistry and Chemical Processing Technologies, Bolu Abant Izzet Baysal University, Bolu 14030, Turkey;
| | - Deniz Türkmen
- Department of Chemistry, Hacettepe University Ankara, Ankara 06800, Turkey
| | - Adil Denizli
- Department of Chemistry, Hacettepe University Ankara, Ankara 06800, Turkey
| | - Murat Özgören
- Department of Biophysics, Faculty of Medicine, Near East University, Nicosia 99138, Cyprus;
| |
Collapse
|
3
|
Gupta A, Rotake D, Darji A. Sensing lead ions in water: a comprehensive review on strategies and sensor materials. ANAL SCI 2024; 40:997-1021. [PMID: 38523231 DOI: 10.1007/s44211-024-00547-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 02/25/2024] [Indexed: 03/26/2024]
Abstract
It is well-known fact that elevated lead ions (Pb2+), the third most toxic among heavy metal ions in aqueous systems, pose a threat to human health and aquatic ecosystems when they exceed permissible limits. Pb2+ is commonly found in industrial waste and fertilizers, contaminating water sources and subsequently entering the human body, causing various adverse health conditions. Unlike being expelled, Pb2+ accumulates within the body, posing potential health risks. The harmful impact of presence of Pb2+ in water have prompted researchers to diligently work toward maintaining water quality. Recognizing the importance of Pb2+, this review article makes a sincere and effective effort to address the issues associated with Pb2+. This overview article gives insights into various sensing approaches to detect Pb2+ in water using different sensing materials, including 2-dimensional materials, thiols, quantum dots, and polymers. Herein, different sensing approaches such as electrochemical, optical, field effect transistor-based, micro-electromechanical system-based, and chemi resistive are thoroughly explained. Field effect transistor-based and chemiresistive work on similar principles and are compared on the basis of their fabrication processes and sensing capabilities. In conclusion, future directions for chemiresistive sensors in Pb2+ detection are proposed, emphasizing their simplicity, portability, straightforward functionality, and ease of fabrication. Notably, it sheds light on various thiol and ligand compounds and coupling strategies utilized in Pb2+ detection. This comprehensive study is expected to benefit individuals engaged in Pb2+ detection.
Collapse
Affiliation(s)
- Anju Gupta
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
- Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management, Ramdeo Tekdi, Nagpur, 440013, Maharashtra, India
| | - Dinesh Rotake
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Hyderabad, 502284, Telangana, India.
| | - Anand Darji
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
| |
Collapse
|
4
|
Liu J, Zou J, Deng L, Peng G, Liu S, Rui P, Wang X, Wang L, Gao Y, Lu L. Electroactive poly(thionine) as imprinted polymer and reference probe simultaneously for ratiometric ion imprinted electrochemical Pb 2+sensor. NANOTECHNOLOGY 2023; 34:505709. [PMID: 37725965 DOI: 10.1088/1361-6528/acfb0d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 09/18/2023] [Indexed: 09/21/2023]
Abstract
In this work, an electrochemical sensor based on ion-imprinted polymer/Au nanoparticles/porous biochar (IIP/AuNPs/PBC) composite was proposed for the highly selective and sensitive detection of Pb2+. In this work, poly (thionine) (pTHI) served simultaneously as imprinted polymer and reference probe. It could not only realize the specific detection of Pb2+, but also provide an internal reference signal to eliminate the influence of human and environmental factors on the detection signal and further improve the stability of the sensor. In addition, the AuNPs/PBC composite with large specific surface area, excellent electron transport and electrocatalytic performance could effectively enhance the detection signal as a carrier material. At the same time, the AuNPs on the PBC surface would promote the formation of uniform and stable IIP through Au-S bonds. The synergistic effect between IIP, AuNPs/PBC and ratiometric signal mode gave the Pb2+sensor excellent performance, including a wide linear range (0.1-1000μg l-1), low detection limit (0.03μg l-1, S/N = 3), excellent selectivity and stability. All these results indicate that the proposed sensor could provide a meaningful reference for highly selective detection of heavy metal ions (HMIs).
Collapse
Affiliation(s)
- Jiawei Liu
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Jin Zou
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Linbo Deng
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Guanwei Peng
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Shuwu Liu
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Peixin Rui
- College National Engineering Research Center for Carbohydrate Synthesis, Jiangxi Normal University, Nanchang 330022, People's Republic of China
| | - Xiaoqiang Wang
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Linyu Wang
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Yansha Gao
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| | - Limin Lu
- Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang 330045, People's Republic of China
| |
Collapse
|
5
|
Vallejos S, Trigo-López M, Arnaiz A, Miguel Á, Muñoz A, Mendía A, García JM. From Classical to Advanced Use of Polymers in Food and Beverage Applications. Polymers (Basel) 2022; 14:4954. [PMID: 36433081 PMCID: PMC9699061 DOI: 10.3390/polym14224954] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/11/2022] [Accepted: 11/14/2022] [Indexed: 11/18/2022] Open
Abstract
Polymers are extensively used in food and beverage packaging to shield against contaminants and external damage due to their barrier properties, protecting the goods inside and reducing waste. However, current trends in polymers for food, water, and beverage applications are moving forward into the design and preparation of advanced polymers, which can act as active packaging, bearing active ingredients in their formulation, or controlling the head-space composition to extend the shelf-life of the goods inside. In addition, polymers can serve as sensory polymers to detect and indicate the presence of target species, including contaminants of food quality indicators, or even to remove or separate target species for later quantification. Polymers are nowadays essential materials for both food safety and the extension of food shelf-life, which are key goals of the food industry, and the irruption of smart materials is opening new opportunities for going even further in these goals. This review describes the state of the art following the last 10 years of research within the field of food and beverage polymer's applications, covering present applications, perspectives, and concerns related to waste generation and the circular economy.
Collapse
Affiliation(s)
- Saúl Vallejos
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Miriam Trigo-López
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Ana Arnaiz
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
- Centro de Biotecnología y Genómica de Plantas, Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria, Campus de Montegancedo, Universidad Politécnica de Madrid (UPM), 28223 Madrid, Spain
| | - Álvaro Miguel
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
- Facultad de Ciencias, Campus de Cantoblanco, Universidad Autónoma de Madrid, Calle Francisco Tomás y Valiente 7, 28049 Madrid, Spain
| | - Asunción Muñoz
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Aránzazu Mendía
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - José Miguel García
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| |
Collapse
|
6
|
A Critical Review on the Use of Molecular Imprinting for Trace Heavy Metal and Micropollutant Detection. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10080296] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Molecular recognition has been described as the “ultimate” form of sensing and plays a fundamental role in biological processes. There is a move towards biomimetic recognition elements to overcome inherent problems of natural receptors such as limited stability, high-cost, and variation in response. In recent years, several alternatives have emerged which have found their first commercial applications. In this review, we focus on molecularly imprinted polymers (MIPs) since they present an attractive alternative due to recent breakthroughs in polymer science and nanotechnology. For example, innovative solid-phase synthesis methods can produce MIPs with sometimes greater affinities than natural receptors. Although industry and environmental agencies require sensors for continuous monitoring, the regulatory barrier for employing MIP-based sensors is still low for environmental applications. Despite this, there are currently no sensors in this area, which is likely due to low profitability and the need for new legislation to promote the development of MIP-based sensors for pollutant and heavy metal monitoring. The increased demand for point-of-use devices and home testing kits is driving an exponential growth in biosensor production, leading to an expected market value of over GPB 25 billion by 2023. A key requirement of point-of-use devices is portability, since the test must be conducted at “the time and place” to pinpoint sources of contamination in food and/or water samples. Therefore, this review will focus on MIP-based sensors for monitoring pollutants and heavy metals by critically evaluating relevant literature sources from 1993 to 2022.
Collapse
|
7
|
Hojatpanah MR, Khanmohammadi A, Khoshsafar H, Hajian A, Bagheri H. Construction and application of a novel electrochemical sensor for trace determination of uranium based on ion-imprinted polymers modified glassy carbon electrode. CHEMOSPHERE 2022; 292:133435. [PMID: 34958794 DOI: 10.1016/j.chemosphere.2021.133435] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/17/2021] [Accepted: 12/23/2021] [Indexed: 06/14/2023]
Abstract
In the present work, a novel electrochemical sensor modified glassy carbon electrode with ion-imprinted polymers (IIP-GCE) was applied for uranyl ions (UO22+) determination. Surface modifier was synthesized through precipitation polymerization method, using acrylic acid as a monomer, benzoyl peroxide (BPO) as initiator, and trimethylolpropane triacrylate (TMPTA) as cross-linker. A new uranyl-trans-3-(3-pyridyl) acrylic acid complex was employed, serving as an active and specific site on the synthesized modifier. Next, the synthesized modifier was characterized using X-ray diffraction (XRD), Scanning Electron microscopy (SEM), and Fourier Transform Infrared Spectroscopy (FT-IR) techniques. UO22+ ions were detected using a differential pulse adsorptive anodic stripping voltammetry method. Under the optimized conditions (pH = 8.0, pre-concentration time = 10 min and pre-concentration potential = -0.30 V), the modified electrode exhibited linear behavior in the interval of 1.27-95.49 μg.L-1 with a limit of detection (LOD) of 0.43 μg.L-1. Also, the constructed ion-imprinted sensor showed a successful application for determining UO22+ ions with recovery range of 97.6-101% in real samples.
Collapse
Affiliation(s)
- Mohammad Reza Hojatpanah
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Akbar Khanmohammadi
- Research and Development Department, Farin Behbood Tashkhis LTD, Tehran, Iran
| | - Hosin Khoshsafar
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Hajian
- Institute of Sensor and Actuator Systems, TU Wien, Vienna, Austria
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
8
|
|
9
|
Mukherjee S, Bhattacharyya S, Ghosh K, Pal S, Halder A, Naseri M, Mohammadniaei M, Sarkar S, Ghosh A, Sun Y, Bhattacharyya N. Sensory development for heavy metal detection: A review on translation from conventional analysis to field-portable sensor. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.01.062] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
10
|
Holmes J, Pathirathna P, Hashemi P. Novel frontiers in voltammetric trace metal analysis: Towards real time, on-site, in situ measurements. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.11.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
11
|
Hersey M, Berger SN, Holmes J, West A, Hashemi P. Recent Developments in Carbon Sensors for At-Source Electroanalysis. Anal Chem 2018; 91:27-43. [PMID: 30481001 DOI: 10.1021/acs.analchem.8b05151] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
12
|
Felix CS, Silva DG, Andrade HM, Riatto VB, Victor MM, Ferreira SL. An on-line system using ion-imprinted polymer for preconcentration and determination of bismuth in seawater employing atomic fluorescence spectrometry. Talanta 2018; 184:87-92. [DOI: 10.1016/j.talanta.2018.02.089] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 02/23/2018] [Accepted: 02/24/2018] [Indexed: 01/19/2023]
|
13
|
Synthesis, characterization and using a new terpyridine moiety-based ion-imprinted polymer nanoparticle: sub-nanomolar detection of Pb(II) in biological and water samples. CHEMICAL PAPERS 2018. [DOI: 10.1007/s11696-018-0523-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
14
|
Dai X, Wu S, Li S. Progress on electrochemical sensors for the determination of heavy metal ions from contaminated water. ACTA ACUST UNITED AC 2018. [DOI: 10.1080/22243682.2018.1425904] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Xiangzi Dai
- Institute of Polymer Materials, School of Materials Science & Engineering, Jiangsu University, Zhenjiang, P. R. China
| | - Shuping Wu
- Institute of Polymer Materials, School of Materials Science & Engineering, Jiangsu University, Zhenjiang, P. R. China
| | - Songjun Li
- Institute of Polymer Materials, School of Materials Science & Engineering, Jiangsu University, Zhenjiang, P. R. China
| |
Collapse
|