1
|
Lee A, Wyckoff E, Farcas E, Godino J, Patrick K, Spiegel S, Yu R, Kumar A, Loh KJ, Gombatto S. Preliminary Validity and Acceptability of Motion Tape for Measuring Low Back Movement: Mixed Methods Study. JMIR Rehabil Assist Technol 2024; 11:e57953. [PMID: 39093610 PMCID: PMC11329853 DOI: 10.2196/57953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/21/2024] [Accepted: 05/21/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND Low back pain (LBP) is a significant public health problem that can result in physical disability and financial burden for the individual and society. Physical therapy is effective for managing LBP and includes evaluation of posture and movement, interventions directed at modifying posture and movement, and prescription of exercises. However, physical therapists have limited tools for objective evaluation of low back posture and movement and monitoring of exercises, and this evaluation is limited to the time frame of a clinical encounter. There is a need for a valid tool that can be used to evaluate low back posture and movement and monitor exercises outside the clinic. To address this need, a fabric-based, wearable sensor, Motion Tape (MT), was developed and adapted for a low back use case. MT is a low-profile, disposable, self-adhesive, skin-strain sensor developed by spray coating piezoresistive graphene nanocomposites directly onto commercial kinesiology tape. OBJECTIVE The objectives of this study were to (1) validate MT for measuring low back posture and movement and (2) assess the acceptability of MT for users. METHODS A total of 10 participants without LBP were tested. A 3D optical motion capture system was used as a reference standard to measure low back kinematics. Retroreflective markers and a matrix of MTs were placed on the low back to measure kinematics (motion capture) and strain (MT) simultaneously during low back movements in the sagittal, frontal, and axial planes. Cross-correlation coefficients were calculated to evaluate the concurrent validity of MT strain in reference motion capture kinematics during each movement. The acceptability of MT was assessed using semistructured interviews conducted with each participant after laboratory testing. Interview data were analyzed using rapid qualitative analysis to identify themes and subthemes of user acceptability. RESULTS Visual inspection of concurrent MT strain and kinematics of the low back indicated that MT can distinguish between different movement directions. Cross-correlation coefficients between MT strain and motion capture kinematics ranged from -0.915 to 0.983, and the strength of the correlations varied across MT placements and low back movement directions. Regarding user acceptability, participants expressed enthusiasm toward MT and believed that it would be helpful for remote interventions for LBP but provided suggestions for improvement. CONCLUSIONS MT was able to distinguish between different low back movements, and most MTs demonstrated moderate to high correlation with motion capture kinematics. This preliminary laboratory validation of MT provides a basis for future device improvements, which will also involve testing in a free-living environment. Overall, users found MT acceptable for use in physical therapy for managing LBP.
Collapse
Affiliation(s)
- Audrey Lee
- Department of Bioengineering, San Diego State University, San Diego, CA, United States
| | - Elijah Wyckoff
- Active, Responsive, Multifunctional, and Ordered-materials Research (ARMOR) Laboratory, Department of Structural Engineering, University of California San Diego, La Jolla, CA, United States
| | - Emilia Farcas
- Qualcomm Institute, University of California San Diego, La Jolla, CA, United States
| | - Job Godino
- Qualcomm Institute, University of California San Diego, La Jolla, CA, United States
- Laura Rodriguez Research Institute, Family Health Centers of San Diego, San Diego, CA, United States
| | - Kevin Patrick
- Qualcomm Institute, University of California San Diego, La Jolla, CA, United States
- School of Public Health, University of California San Diego, La Jolla, CA, United States
| | - Spencer Spiegel
- Department of Mathematics and Statistics, San Diego State University, San Diego, CA, United States
| | - Rose Yu
- Computer Science and Engineering and Halicioglu Data Science Institute, University of California San Diego, La Jolla, CA, United States
| | - Arun Kumar
- Computer Science and Engineering and Halicioglu Data Science Institute, University of California San Diego, La Jolla, CA, United States
| | - Kenneth J Loh
- Active, Responsive, Multifunctional, and Ordered-materials Research (ARMOR) Laboratory, Department of Structural Engineering, University of California San Diego, La Jolla, CA, United States
| | - Sara Gombatto
- School of Physical Therapy, San Diego State University, San Diego, CA, United States
| |
Collapse
|
2
|
Lange J, Schneider AE, Jordi C. Quantifying Patient Capabilities and Setting the Stage for Future Development: Insights from a Sensor-Augmented Simulated Use Study with Pen Injectors. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2024; 17:271-283. [PMID: 39099757 PMCID: PMC11298175 DOI: 10.2147/mder.s478141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 07/24/2024] [Indexed: 08/06/2024] Open
Abstract
Background While formative and summative usability testing is essential to confirm safe and effective product use, it may not be sufficient to comprehensively understand user capabilities and limitations in device interactions. Therefore, this research aims to quantify user handling forces for different device handling steps of pen injectors through sensor-augmented simulated use studies. Research Design and methods The study involved 46 participants who were divided into two groups: a healthy control group and a group of users with dexterity impairments. All participants were instructed to perform simulated handling steps using non-functional dummy devices equipped with force and torque sensors. Each handling step was performed twice: first at what participants considered a comfortable force level and then at their maximum force. The study then analyzed force data to investigate the impact of user characteristics and device geometry on force exertion during the different handling steps. Results The study demonstrates differences in the perceived comfortable and maximum force levels between the control and patient groups. These force levels decrease slightly with the user's age and level of dexterity impairment. Furthermore, the forces applied by the users are dependent on the geometry of the device and the holding pattern. Conclusion The results highlight the significance of sensor-augmented simulated use studies as a tool for providing quantitative insights into users' ability to exert force while handling self-injection devices. These data offer comprehensive insights that inform the definition of performance requirements and specifications for injection device design, thereby supporting the advancement of future self-injection devices.
Collapse
|
3
|
Abraham I, Crawford J, Schwartzberg L. On-body injector pegfilgrastim for chemotherapy-induced neutropenia prophylaxis: Current Status. Cancer Treat Res Commun 2024; 40:100824. [PMID: 38865836 DOI: 10.1016/j.ctarc.2024.100824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Revised: 05/28/2024] [Accepted: 05/28/2024] [Indexed: 06/14/2024]
Abstract
INTRODUCTION Myelosuppression, a challenge in cancer treatment, often results in severe complications. Prophylactic granulocyte colony-stimulating factors, particularly pegfilgrastim, mitigate chemotherapy-induced neutropenia. This narrative review evaluates the role of on-body injector (OBI) devices for pegfilgrastim administration. A comprehensive search strategy of PubMed and AI-powered intuitive search tools, complemented by authors' contributions, yielded a body of papers presenting evidence on OBI devices, their effectiveness and safety, the benefits and challenges of OBI versus pre-filled syringe administration, patient preferences for pegfilgrastim administration, and economic considerations. DISCUSSION OBI devices prove effective and safe, with advantages such as reduced clinic visits and enhanced adherence. Studies highlight cost-efficiency and expanded access, emphasizing the socioeconomic context. Patient and provider preferences underscore the potential of OBI devices in cancer care, with implications for healthcare resource utilization and pharmacoeconomics. CONCLUSION The value proposition of OBI devices lies in improving patient outcomes, convenience, resource optimization, and enhancing the overall cancer care experience. As biosimilar OBIs enter the market, they may offer cost savings, further influencing their adoption and their positioning as a cost-efficient alternative in cancer care. Ongoing research and technological advancements are expected to contribute to the broader acceptance of OBI devices in cancer care delivery.
Collapse
Affiliation(s)
- Ivo Abraham
- Center for Health Outcomes and Pharmacoeconomic Research Center, R. Ken Coit College of Pharmacy, University of Arizona, Tucson, AZ, USA; The University of Arizona Cancer Center, Tucson, AZ, USA.
| | | | - Lee Schwartzberg
- William N. Pennington Cancer Institute at Renown Health, Reno, NV, USA; School of Medicine, University of Nevada - Reno, Reno, NV, USA
| |
Collapse
|
4
|
Brunet-Manquat L, Combedazou A, Ahuja B, Maden A, Ramus C, Mardovina T, Frolet C. Pre-ANDA strategy and Human Factors activities to de-risk pharmaceutical companies ANDA submission of drug-device combination products: case study of a formative Comparative Use Human Factors study. Expert Opin Drug Deliv 2024; 21:767-778. [PMID: 38753579 DOI: 10.1080/17425247.2024.2356678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Accepted: 05/01/2024] [Indexed: 05/18/2024]
Abstract
BACKGROUND This article presents a strategy that a Drug Delivery Device Developer (DDDD) has adopted to support Abbreviated New Drug Application (ANDA) submissions of drug-device combination products. As per the related FDA guidance, a threshold analysis should be compiled. If 'other differences' between the Reference Listed Drug (RLD) and the generic drug devices are identified, a Comparative Use Human Factors (CUHF) study may be requested. METHODS The DDDD performed task analysis and physical comparison to assess the pen injector design differences. Then, a formative CUHF study with 25 participants simulating injections using both RLD and the generic pen injectors was conducted. RESULTS After each participant completed four simulated injections, similar type and rates of use error between the RLD (0.70) and generic (0.68) pen injectors were observed. CONCLUSION DDDDs can support pharmaceutical companies in the ANDA submission strategy of their drug-device combination product by initiating comparative task analysis and physical comparison of the device as inputs for the threshold analysis. If 'other differences' are identified, a formative CUHF study can be performed. As shown in our case study, this approach can be leveraged to support the sample size calculation and non-inferiority margin determination for a CUHF study with the final combination product.
Collapse
Affiliation(s)
- Laurie Brunet-Manquat
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company, Le Pont-de-Claix, France
| | - Anne Combedazou
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company, Le Pont-de-Claix, France
| | - Bomby Ahuja
- BD Medical - Pharmaceutical Systems, Becton, Dickinson and Company, Franklin Lakes, NJ, USA
| | - Alice Maden
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company, Le Pont-de-Claix, France
| | - Claire Ramus
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company, Le Pont-de-Claix, France
| | - Tatsiana Mardovina
- BD Medical - Pharmaceutical Systems, Becton, Dickinson and Company, Franklin Lakes, NJ, USA
| | - Cécile Frolet
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company, Le Pont-de-Claix, France
| |
Collapse
|
5
|
Davis JD, Bravo Padros M, Conrado DJ, Ganguly S, Guan X, Hassan HE, Hazra A, Irvin SC, Jayachandran P, Kosloski MP, Lin KJ, Mukherjee K, Paccaly A, Papachristos A, Partridge MA, Prabhu S, Visich J, Welf ES, Xu X, Zhao A, Zhu M. Subcutaneous Administration of Monoclonal Antibodies: Pharmacology, Delivery, Immunogenicity, and Learnings From Applications to Clinical Development. Clin Pharmacol Ther 2024; 115:422-439. [PMID: 38093583 DOI: 10.1002/cpt.3150] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 12/06/2023] [Indexed: 01/11/2024]
Abstract
Subcutaneous (s.c.) administration of monoclonal antibodies (mAbs) can reduce treatment burden for patients and healthcare systems compared with intravenous (i.v.) infusion through shorter administration times, made possible by convenient, patient-centric devices. A deeper understanding of clinical pharmacology principles related to efficacy and safety of s.c.-administered mAbs over the past decade has streamlined s.c. product development. This review presents learnings from key constituents of the s.c. mAb development pathway, including pharmacology, administration variables, immunogenicity, and delivery devices. Restricted mAb transportation through the hypodermis explains their incomplete absorption at a relatively slow rate (pharmacokinetic (PK)) and may impact mAb-cellular interactions and/or onset and magnitude of physiological responses (pharmacodynamic). Injection volumes, formulation, rate and site of injection, and needle attributes may affect PKs and the occurrence/severity of adverse events like injection-site reactions or pain, with important consequences for treatment adherence. A review of immunogenicity data for numerous compounds reveals that incidence of anti-drug antibodies (ADAs) is generally comparable across i.v. and s.c. routes, and complementary factors including response magnitude (ADA titer), persistence over time, and neutralizing antibody presence are needed to assess clinical impact. Finally, four case studies showcase how s.c. biologics have been clinically developed: (i) by implementation of i.v./s.c. bridging strategies to streamline PD-1/PD-L1 inhibitor development, (ii) through co-development with i.v. presentations for anti-severe acute respiratory syndrome-coronavirus 2 antibodies to support rapid deployment of both formulations, (iii) as the lead route for bispecific T cell engagers (BTCEs) to mitigate BTCE-mediated cytokine release syndrome, and (iv) for pediatric patients in the case of dupilumab.
Collapse
Affiliation(s)
- John D Davis
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | | | - Samit Ganguly
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Xiaowen Guan
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Hazem E Hassan
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Anasuya Hazra
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Susan C Irvin
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | | | - Kuan-Ju Lin
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | - Anne Paccaly
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | | | - Saileta Prabhu
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | - Erik S Welf
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Xiaoying Xu
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - An Zhao
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Min Zhu
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| |
Collapse
|
6
|
Lee A, Dionicio P, Farcas E, Godino J, Patrick K, Wyckoff E, Loh KJ, Gombatto S. Physical Therapists' Acceptance of a Wearable, Fabric-Based Sensor System (Motion Tape) for Use in Clinical Practice: Qualitative Focus Group Study. JMIR Hum Factors 2024; 11:e55246. [PMID: 38421708 PMCID: PMC10940997 DOI: 10.2196/55246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/13/2024] [Accepted: 01/17/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND Low back pain (LBP) is a costly global health condition that affects individuals of all ages and genders. Physical therapy (PT) is a commonly used and effective intervention for the management of LBP and incorporates movement assessment and therapeutic exercise. A newly developed wearable, fabric-based sensor system, Motion Tape, uses novel sensing and data modeling to measure lumbar spine movements unobtrusively and thus offers potential benefits when used in conjunction with PT. However, physical therapists' acceptance of Motion Tape remains unexplored. OBJECTIVE The primary aim of this research study was to evaluate physical therapists' acceptance of Motion Tape to be used for the management of LBP. The secondary aim was to explore physical therapists' recommendations for future device development. METHODS Licensed physical therapists from the American Physical Therapy Association Academy of Leadership Technology Special Interest Group participated in this study. Overall, 2 focus groups (FGs; N=8) were conducted, in which participants were presented with Motion Tape samples and examples of app data output on a poster. Informed by the Technology Acceptance Model, we conducted semistructured FGs and explored the wearability, usefulness, and ease of use of and suggestions for improvements in Motion Tape for PT management of LBP. FG data were transcribed and analyzed using rapid qualitative analysis. RESULTS Regarding wearability, participants perceived that Motion Tape would be able to adhere for several days, with some variability owing to external factors. Feedback was positive for the low-profile and universal fit, but discomfort owing to wires and potential friction with clothing was of concern. Other concerns included difficulty with self-application and potential skin sensitivity. Regarding usefulness, participants expressed that Motion Tape would enhance the efficiency and specificity of assessments and treatment. Regarding ease of use, participants stated that the app would be easy, but data management and challenges with interpretation were of concern. Physical therapists provided several recommendations for future design improvements including having a wireless system or removable wires, customizable sizes for the tape, and output including range of motion data and summary graphs and adding app features that consider patient input and context. CONCLUSIONS Several themes related to Motion Tape's wearability, usefulness, and ease of use were identified. Overall, physical therapists expressed acceptance of Motion Tape's potential for assessing and monitoring low back posture and movement, both within and outside clinical settings. Participants expressed that Motion Tape would be a valuable tool for the personalized treatment of LBP but highlighted several future improvements needed for Motion Tape to be used in practice.
Collapse
Affiliation(s)
- Audrey Lee
- Department of Bioengineering, San Diego State University, San Diego, CA, United States
| | - Patricia Dionicio
- Joint Doctoral Program in Public Health, San Diego State University and University of California San Diego, San Diego, CA, United States
| | - Emilia Farcas
- Qualcomm Institute, University of California San Diego, La Jolla, CA, United States
| | - Job Godino
- Qualcomm Institute, University of California San Diego, La Jolla, CA, United States
| | - Kevin Patrick
- Qualcomm Institute, University of California San Diego, La Jolla, CA, United States
- School of Public Health, University of California San Diego, La Jolla, CA, United States
| | - Elijah Wyckoff
- Active, Responsive, Multifunctional, and Ordered-materials Research (ARMOR) Laboratory, Department of Structural Engineering, University of California San Diego, La Jolla, CA, United States
| | - Kenneth J Loh
- Active, Responsive, Multifunctional, and Ordered-materials Research (ARMOR) Laboratory, Department of Structural Engineering, University of California San Diego, La Jolla, CA, United States
| | - Sara Gombatto
- School of Exercise & Nutritional Sciences, College of Health & Human Services, San Diego State University, San Diego, CA, United States
| |
Collapse
|
7
|
Green P, Schneider A, Lange J. Navigating large-volume subcutaneous injections of biopharmaceuticals: a systematic review of clinical pipelines and approved products. MAbs 2024; 16:2402713. [PMID: 39279181 PMCID: PMC11407384 DOI: 10.1080/19420862.2024.2402713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 09/04/2024] [Accepted: 09/05/2024] [Indexed: 09/18/2024] Open
Abstract
Subcutaneous (SC) administration is transforming the delivery of biopharmaceuticals, facilitating care in a variety of healthcare settings, including home self-treatment. Large-volume single SC doses have gained attention for their potential to expand therapeutic applications and improve long-term, patient-centric dosing regimens, often at a reduced SC injection frequency. However, a systematic understanding of dose volumes and frequencies for large-volume (>2.0 mL) SC biopharmaceuticals (LVSCs) is lacking. Accordingly, this study systematically reviewed clinical-stage and approved intravenous (IV) and SC biopharmaceuticals, identifying 182 LVSCs - predominantly monoclonal or bispecific antibodies - which correspond to approximately 15% of all IV and SC biopharmaceuticals. These LVSCs are designed to target cancer and a range of non-cancer chronic disease states, including autoimmune, neurological, and cardiovascular diseases. Results show that anti-cancer LVSCs (n = 75) typically require 5.0 to 20.0 mL doses every three weeks and are administered by healthcare professionals. In contrast, non-cancer LVSCs (n = 107), which are typically self-administered monthly, show more significant dosing variability, with < 5.0 mL being the predominant volume range. Furthermore, the study identified a substantial clinical pipeline of potential LVSCs, many of which are being injected at increasingly lower dosing frequencies, suggesting significant future growth in this area. Most non-cancer LVSCs are currently undergoing clinical trials via the SC route, whereas the majority of the cancer LVSCs are being administered IV and require transition to the SC route. These findings highlight the importance of developing large-volume drug delivery systems and novel formulations to reduce injection volumes. The analysis provides valuable guidance for new product development, as well as for marketing and commercialization strategies in the rapidly evolving LVSC landscape.
Collapse
Affiliation(s)
| | | | - Jakob Lange
- Delivery Systems, Ypsomed AG, Burgdorf, Switzerland
| |
Collapse
|
8
|
Althobiani MA, Khan B, Shah AJ, Ranjan Y, Mendes RG, Folarin A, Mandal S, Porter JC, Hurst JR. Clinicians' Perspectives of Wearable Technology to Detect and Monitor Exacerbations of Chronic Obstructive Pulmonary Disease: Mixed-Method Survey. Int J Chron Obstruct Pulmon Dis 2023; 18:1401-1412. [PMID: 37456915 PMCID: PMC10349580 DOI: 10.2147/copd.s405386] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 06/25/2023] [Indexed: 07/18/2023] Open
Abstract
Objective To investigate clinicians' perspectives on the current use of wearable technology for detecting COPD exacerbations, and to identify potential facilitators and barriers to its adoption in clinical settings. Methods A mixed-method survey was conducted through an online survey platform involving clinicians working with COPD patients. The questionnaires were developed by an expert panel specialising in respiratory medicine at UCL. The questionnaire evaluated clinicians' perspectives on several aspects: the current extent of wearable technology utilisation, the perceived feasibility, and utility of these devices, as well as the potential facilitators and barriers that hinder its wider implementation. Results Data from 118 clinicians were included in the analysis. Approximately 80% of clinicians did not currently use information from wearable devices in routine clinical care. A majority of clinicians did not have confidence in the effectiveness of wearables and their consequent impact on health outcomes. However, clinicians highlighted the potential value of wearables in helping deliver personalised care and more rapid assistance. Ease of use, technical support and accessibility of data were considered facilitating factors for wearable utilisation. Costs and lack of technical knowledge were the most frequently reported barriers to wearable utilisation. Conclusion Clinicians' perspectives of the use of wearable technology to detect and monitor COPD exacerbations are variable. While accessibility and technical support facilitate wearable implementation, cost, technical issues, and knowledge act as barriers. Our findings highlight the facilitators and barriers to using wearables in patients with COPD and emphasise the need to assess patients' perspectives on wearable acceptability.
Collapse
Affiliation(s)
- Malik A Althobiani
- UCL Respiratory, University College London, London, UK
- Department of Respiratory Therapy, Faculty of Medical Rehabilitation Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Bilal Khan
- UCL Respiratory, University College London, London, UK
| | - Amar J Shah
- UCL Respiratory, University College London, London, UK
- Department of Respiratory Medicine, Royal Free London NHS Foundation Trust, London, UK
| | - Yatharth Ranjan
- Department of Health Informatics and Biostatistics, Institute of Psychiatry, Psychology and Neuroscience, Kings College London, London, UK
| | - Renata G Mendes
- UCL Respiratory, University College London, London, UK
- Department of Physical Therapy, Cardiopulmonary Physiotherapy Laboratory, Federal University of São Carlos, São Paulo, Brazil
| | - Amos Folarin
- Department of Health Informatics and Biostatistics, Institute of Psychiatry, Psychology and Neuroscience, Kings College London, London, UK
| | - Swapna Mandal
- UCL Respiratory, University College London, London, UK
- Department of Respiratory Medicine, Royal Free London NHS Foundation Trust, London, UK
| | - Joanna C Porter
- UCL Respiratory, University College London, London, UK
- Department of Respiratory Medicine, University College London Hospital (UCLH), London, UK
| | - John R Hurst
- UCL Respiratory, University College London, London, UK
- Department of Respiratory Medicine, Royal Free London NHS Foundation Trust, London, UK
| |
Collapse
|
9
|
Desai PG, Garidel P, Gbormittah FO, Kamen DE, Mills BJ, Narasimhan CN, Singh S, Stokes ESE, Walsh ER. An Intercompany Perspective on Practical Experiences of Predicting, Optimizing and Analyzing High Concentration Biologic Therapeutic Formulations. J Pharm Sci 2023; 112:359-369. [PMID: 36442683 DOI: 10.1016/j.xphs.2022.11.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 11/18/2022] [Accepted: 11/18/2022] [Indexed: 11/27/2022]
Abstract
Developing high-dose biologic drugs for subcutaneous injection often requires high-concentration formulations and optimizing viscosity, solubility, and stability while overcoming analytical, manufacturing, and administration challenges. To understand industry approaches for developing high-concentration formulations, the Formulation Workstream of the BioPhorum Development Group, an industry-wide consortium, conducted an inter-company collaborative exercise which included several surveys. This collaboration provided an industry perspective, experience, and insight into the practicalities for developing high-concentration biologics. To understand solubility and viscosity, companies desire predictive tools, but experience indicates that these are not reliable and experimental strategies are best. Similarly, most companies prefer accelerated and stress stability studies to in-silico or biophysical-based prediction methods to assess aggregation. In addition, optimization of primary container-closure and devices are pursued to mitigate challenges associated with high viscosity of the formulation. Formulation strategies including excipient selection and application of studies at low concentration to high-concentration formulations are reported. Finally, analytical approaches to high concentration formulations are presented. The survey suggests that although prediction of viscosity, solubility, and long-term stability is desirable, the outcome can be inconsistent and molecule dependent. Significant experimental studies are required to confirm robust product definition as modeling at low protein concentrations will not necessarily extrapolate to high concentration formulations.
Collapse
Affiliation(s)
- Preeti G Desai
- Bristol Myers Squibb, Sterile Product Development, 556 Morris Avenue, Summit, NJ 07901, USA
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH Co KG, Innovation Unit, PDB-TIP, 88397 Biberach an der Riss, Germany
| | - Francisca O Gbormittah
- GlaxoSmithKline, Strategic External Development, 1000 Winter Street North, Waltham, MA 02451, USA
| | - Douglas E Kamen
- Regeneron Pharmaceuticals Inc., Formulation Development, 777 Old Saw Mill River Road, Tarrytown, NY 10591, USA
| | - Brittney J Mills
- AbbVie, NBE Drug Product Development, 1 N Waukegan Road, North Chicago, IL 60064, USA
| | | | - Shubhadra Singh
- GlaxoSmithKline R&D, Biopharmaceutical Product Sciences, Collegeville, PA 19426, USA
| | - Elaine S E Stokes
- BioPhorum, The Gridiron Building, 1 Pancras Square, London N1C 4AG UK.
| | - Erika R Walsh
- Merck & Co., Inc., Sterile and Specialty Products, Rahway, NJ, USA
| |
Collapse
|
10
|
Schneider A, Kolrep H, Horn HP, Jordi C, Gierig S, Lange J. Understanding patient preferences for handheld autoinjectors versus wearable large-volume injectors. Expert Opin Drug Deliv 2023; 20:273-283. [PMID: 36546325 DOI: 10.1080/17425247.2022.2162037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE While interest in the use of wearable large-volume injectors for subcutaneous drug delivery is increasing, it remains unclear whether and under what conditions these emerging dosing options are preferred over more frequent but shorter administration of smaller doses using handheld autoinjectors. Therefore, the objective of this study was to examine the characteristics of patients diagnosed with cancer, diabetes, inflammatory and cardiovascular diseases, and treatment attributes that determine device preferences. METHODS Based on a cross-sectional online choice experiment, 191 participants expressed their preferences without being physically exposed to the devices or performing injections. Logistic hierarchical regression models were used to assess which patient characteristics, and how changes in treatment attributes, drive device preferences. RESULTS Participant quality of life reduced the likelihood of preferring wearable large-volume injectors to handheld autoinjectors. Moreover, reducing injection frequency from biweekly to monthly to quarterly injections, and shortening injection duration from 33 to 8 min, significantly increased the likelihood of patients preferring large-volume injectors to autoinjectors (p < 0.001). CONCLUSION The study revealed patient quality of life as predictor of device preference and identified critical inflection points in injection duration and injection frequency, at which patient preferences shift from handheld autoinjectors to wearable large-volume injectors.
Collapse
Affiliation(s)
| | | | | | | | - Sina Gierig
- HFC Human-Factors-Consult GmbH, Berlin, Germany
| | | |
Collapse
|