1
|
Sokol JT, Rossin EJ. Ophthalmic Trauma-Related Instruments-Critical Tools for Winning the Case. Int Ophthalmol Clin 2024; 64:187-207. [PMID: 38525991 DOI: 10.1097/iio.0000000000000486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
|
2
|
Richards E, Ye SH, Ash SR, Li L. A Perfluorocarbon-Coated ZrP Cation Exchanger with Excellent Ammonium Selectivity and Chemical Stability: An Oral Sorbent for End-Stage Kidney Disease (ESKD). LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023. [PMID: 37227933 DOI: 10.1021/acs.langmuir.3c00753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
An oral sorbent to remove NH4+ within the small intestine of end-stage kidney disease (ESKD) patients could reduce blood urea levels and diminish their dialysis treatment burden. But current sorbent materials like amorphous zirconium phosphate particles Zr(HPO4)2·H2O (ZrP) lack the selectivity to remove NH4+ in water solution with other competing ions. Our previous work found that a gas-permeable, hydrophobic polydimethylsiloxane (PDMS) coating on ZrP improved the material's selectivity for NH4+. However, a competing ion Ca2+ was still removed by PDMS-coated ZrP sorbent, and the permeability of the PDMS coating to Ca2+ was increased after low-pH stomach-like condition exposure. An alternative hydrophobic and gas permeable coating has been investigated─perfluorooctyltriethoxysilane (FOTS). The coating was attached in place of PDMS to a tetraethyl orthosilicate-coated ZrP surface. Surface atomic composition analysis and scanning electron microscopy observation verified the successful application of the FOTS coating. Water contact angle analysis validated the FOTS coating was hydrophobic (145.0 ± 3.2°). In vitro competing ion studies indicated the FOTS coating attached to ZrP increased NH4+ removal by 53% versus uncoated ZrP. FOTS offers complete selectivity for NH4+ over Ca2+ with similar NH4+ capacity as the previous PDMS coating. Moreover, FOTS-coated ZrP maintained NH4+ removal capacity and selectivity after the acid exposure study, indicating excellent acid resistance while NH4+ selectivity of ZrP-PDMS decreased by 72%. The results suggested that FOTS-coated ZrP is promising as an oral sorbent for ESKD patients.
Collapse
Affiliation(s)
- Evan Richards
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Sang-Ho Ye
- McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania 15219, United States
- Department of Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Stephen R Ash
- CEO, HemoCleanse Technologies, LLC, Lafayette, Indiana 47904, United States
| | - Lei Li
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| |
Collapse
|
3
|
Rogaczewska M, Stopa M. Total Filling of the Vitreous Cavity With a Cohesive Ophthalmic Viscosurgical Device to Support the Removal of the Intraocular Foreign Body. Retina 2023; 43:851-854. [PMID: 32472826 DOI: 10.1097/iae.0000000000002858] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the effectiveness of loading the vitreous cavity with a cohesive ophthalmic viscosurgical device in aiding the removal of the posterior segment intraocular foreign body (IOFB). METHODS Seven consecutive patients underwent a small-gauge vitrectomy due to eye trauma with the IOFB between January 2019 and December 2019. The IOFB removal was initiated after total filling the vitreous cavity with the ophthalmic viscosurgical device (Eyefill C or Bio-Hyalur Plus) to facilitate maneuvering and slow the descent in cases of the unintendedly released IOFBs. The eye examination was performed at presentation and at 1 day, 7 days, 1 month, and 3 months after surgery. The best-corrected visual acuity and intraocular pressure were evaluated. RESULTS In all eyes, IOFBs were elevated into the center of the vitreous cavity and could be securely gripped while suspended in the ophthalmic viscosurgical device to allow the surgeon for successful and harmless removal. In the 3-month follow-up, the best-corrected visual acuity was 20/20 in 5 patients and 20/25 in 2 patients. In the early postoperative period, the elevation of intraocular pressure did not occur. No patient developed endophthalmitis. CONCLUSION The authors demonstrated that this uncomplicated technique is an effective surgical option for more reliable removal of posterior segment IOFBs.
Collapse
Affiliation(s)
- Małgorzata Rogaczewska
- Department of Ophthalmology, Chair of Ophthalmology and Optometry, Poznan University of Medical Sciences, Poznan, Poland
| | | |
Collapse
|
4
|
Zhu WENTING, Tian J, Lu X, Gao X, Wei J, Yuan G, Zhang J. INCIDENCE AND RISK FACTORS OF POSTOPERATIVE ENDOPHTHALMITIS AFTER PRIMARY SURGICAL REPAIR COMBINED WITH INTRAOCULAR FOREIGN BODY REMOVAL. Retina 2022; 42:1144-1150. [PMID: 35594077 PMCID: PMC9112954 DOI: 10.1097/iae.0000000000003440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To analyze the incidence and risk factors of postoperative endophthalmitis after primary surgical repair and intraocular foreign body (IOFB) removal within 24 hours of injury. METHODS The records of all patients treated surgically for open globe injury and IOFB removal at the Eye Hospital of Shandong First Medical University between January 1, 2015, and June 30, 2020, were retrospectively reviewed. Variables included time from injury to operation, cause of injury, details of surgical repair, and follow-up. The incidence and risk factors of endophthalmitis after IOFB removal were studied. RESULTS During 5 years, 99 patients with IOFB were reviewed. Of these, 19 patients were diagnosed with endophthalmitis on admission, and 5 were suspected of having endophthalmitis during operation. Fifty-four cases had no clinical signs of endophthalmitis on admission and during operation and were treated with operation within 24 hours after the injury. Two patients (2 of 54; 3.70%) developed endophthalmitis after IOFB removal, and the causative agent in both cases was Bacillus cereus. CONCLUSION The incidence of infectious endophthalmitis after primary surgical repair combined with IOFB removal (≤24 hours) was 3.70% in patients who received a series of standard treatments, and B. cereus infection might be a risk factor.
Collapse
Affiliation(s)
- WENTING Zhu
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, Shandong Province, China; and
| | - Jingyi Tian
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China.
| | - Xiuhai Lu
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, Shandong Province, China; and
| | - Xiang Gao
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China.
| | - Jianmin Wei
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China.
| | - Gongqiang Yuan
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China.
| | - Jingjing Zhang
- Eye Hospital of Shandong First Medical University, Jinan, Shandong, China;
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, Shandong Province, China; and
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China.
| |
Collapse
|
5
|
A Cross-Knotted Suture Basket Technique for Large Nonmagnetic Intraocular Foreign Body Removal. J Ophthalmol 2020; 2020:1061462. [PMID: 32377410 PMCID: PMC7196965 DOI: 10.1155/2020/1061462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Accepted: 04/03/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose To report a novel technique of cross-knotted suture basket and to test its effectiveness in large nonmagnetic intraocular foreign body (IOFB) removal. Methods A 7/0 Vicryl suture was cut in half and cross-knotted, and four ends were introduced into a 23G needle to form a basket. Pig eyes were used to set up the IOFB model, and the effectiveness of the suture basket in the removal of large nonmagnetic intraocular foreign bodies was tested. Results Several modifications can be made to adapt to different situations. For the materials (stone, metal, glass, and wood) and shapes (irregular, spherical, and rectangle) of large IOFB tested, the cross-knotted suture basket successfully removed all kinds of IOFBs. Conclusion The suture basket technique provides an accessible, safe, and effective alternative in large nonmagnetic IOFB removal. It can be adapted and interchangedand also worth's further clinical investigations.
Collapse
|