1
|
Bouvarel H, Agard E, Billant J, Levron A, Chudzinski R, Plas H, Bernier R, Sejournet L, Chaperon M, Dot C. Long-term real-life outcomes of the Clareon® hydrophobic intraocular lens: the Clarte study in 191 eyes : 3-years real-life outcomes of the Clareon® intraocular lens. BMC Ophthalmol 2024; 24:133. [PMID: 38532367 PMCID: PMC10964544 DOI: 10.1186/s12886-024-03393-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 03/13/2024] [Indexed: 03/28/2024] Open
Abstract
BACKGROUND To describe and analyze the real-life refractive, functional and safety outcomes of the Clareon® intraocular lens (IOL) after 3 years. METHODS Data was collected retrospectively for observational purposes between July 2017 and December 2019 in the ophthalmology department of Desgenettes military hospital in Lyon, France. Eyes that underwent cataract surgery with Claeron® implantation were consecutively included. Patients with a systemic or ocular condition that could affect the visual outcome were excluded. Postoperative corrected (CDVA) and uncorrected (UDVA) distance visual acuities as well as capsule and IOL transparency were assessed at 1 month and 3 years. RESULTS A total of 326 eyes were analyzed at one month and 191 eyes were reassessed at the 3-year follow-up visit. At 3 years, the mean CDVA was 0.003 LogMAR (95% confidence interval [CI]: -0.003 to -0.01) and the mean UDVA was 0.075 (95% CI: 0.054 to 0.095). Three quarters of the patients had an UDVA ≥ 0.097 logMAR (20/25 Snellen equivalent) and 50% had an UDVA ≥ 0 (20/20). The absence of glistening was reported in 95.3% of cases and 4.7% [9] of patients experienced a clinically significant posterior capsular opacification (PCO) for which Nd:YAG treatment was required. CONCLUSIONS This real-life study reports high-performance and stable long-term refractive outcomes of the Clareon® IOL with good safety in terms of PCO and glistening.
Collapse
Affiliation(s)
- Hugo Bouvarel
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France.
| | - Emilie Agard
- Department of Ophthalmology, Desgenettes Military Hospital, Lyon, France
| | - Jérémy Billant
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
- Department of Ophthalmology, Desgenettes Military Hospital, Lyon, France
| | - Antoine Levron
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
| | - Roman Chudzinski
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
| | - Hélène Plas
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
| | - Raphaël Bernier
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
| | - Lucas Sejournet
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
| | - Mayeul Chaperon
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
| | - Corinne Dot
- Department of Ophthalmology, Hospices Civils de Lyon, E. Herriot University Hospital, Lyon, France
- Department of Ophthalmology, Desgenettes Military Hospital, Lyon, France
- French Military Medical Academy, Val-de-Grâce, Paris, France
| |
Collapse
|
2
|
Yamashita K, Hayashi K, Hata S. Clinical performance and shape analysis of trifocal intraocular lenses via scanning electron microscopy. BMC Ophthalmol 2024; 24:86. [PMID: 38409015 PMCID: PMC10895732 DOI: 10.1186/s12886-024-03355-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 02/16/2024] [Indexed: 02/28/2024] Open
Abstract
BACKGROUND To evaluate visual performance after implantation of the TFNT (Acrysof Panoptix, Alcon, Fort Worth, Texas, USA) and CNWT (Clareon Panoptix, Alcon, Fort Worth, Texas, USA) intraocular lens (IOL), and compare the lens shape observed by scanning electron microscope (SEM). METHODS Eighteen patients (18 eyes) received implantation of the CNWT and Twenty patients (20 eyes) received implantation of the TFNT. Exclusion criteria were previous ocular surgeries, ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 1 months including manifest refraction; evaluation of refractive error, distance-corrected visual acuity (DCVA) at 5 m, 1 m, 70 cm, 50 cm, 40 cm, and 30 cm, slit-lamp examination; defocus curve testing; contrast sensitivity (CS) was performed. The lens shape of the TFNT and the CNWT was examined under SEM. RESULTS Mean spherical equivalent was 0.11 ± 0.41 D (CNWT group) and 0.12 ± 0.34 D (TFNT group) 1 month postoperation. DCVA and defocus curve showed no significant difference between the two groups. CS was significantly higher in CNWT group than TFNT group at spatial frequencies of 6 cycles per degree (cpd). Observation of the IOL with a scanning electron microscope (SEM) revealed that CNWT group had improved diffraction structure and edge processing accuracy compared to TFNT group. CONCLUSION There was no significant difference between the two groups in the defocus curve and visual acuity at all distances. CS was better in the CNWT group than in the TFNT group. IOL surface features may affect CS.
Collapse
Affiliation(s)
- Kazuya Yamashita
- Department of Ophthalmology, Keiyu Hospital, 3-7-3 Minatomirai, Yokohama Nishi-ku , 220-8521, Yokohama City, Kanagawa, Japan.
- Sky-building Eye Clinic, Yokohama City, Kanagawa, Japan.
| | - Koji Hayashi
- Sky-building Eye Clinic, Yokohama City, Kanagawa, Japan.
| | - Seiichiro Hata
- Sky-building Eye Clinic, Yokohama City, Kanagawa, Japan.
| |
Collapse
|
3
|
Lee Y, Kim JS, Kim BG, Hwang JH, Kang MJ, Lee JH. Comparison of the Incidence of Nd:YAG Laser Capsulotomy Based on the Type of Intraocular Lens. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:2173. [PMID: 38138276 PMCID: PMC10744545 DOI: 10.3390/medicina59122173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 12/07/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
Background and Objectives: Posterior capsular opacification (PCO) is the most common long-term complication of successful cataract surgery and can cause visual impairment. We aimed to investigate the effects of intraocular lens (IOL) characteristics on PCO by comparing the incidence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy for different types of intraocular lenses. Materials and Methods: A retrospective analysis was performed on 2866 eyes that underwent cataract surgery between January 2010 and December 2017, with at least 5 years of follow-up. The IOLs used for surgery were the hydrophobic lenses SN60WF (Alcon, Fort Worth, TX, USA), ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA), and MX60 (Bausch & Lomb, Rochester, NY, USA), and the hydrophilic lens MI60 (Bausch & Lomb, Rochester, NY, USA). We analyzed the incidence of Nd:YAG laser capsulotomy according to the type of IOL used. Results: The incidence of Nd:YAG laser capsulotomy was significantly higher with MI60 lenses (31.70%, 175/552 eyes) compared to SN60WF (7.90%, 113/1431 eyes), ZCB00 (10.06%, 64/636 eyes), and MX60 (10.57%, 13/123 eyes; p < 0.001) lenses. The incidence of Nd:YAG laser capsulotomy was significantly lower with the hydrophobic IOLs (8.68%, 190/2190 eyes) than with the hydrophilic IOL (31.70%, 175/552 eyes; p < 0.001). Over time, the rate of increase in the cumulative number of Nd:YAG laser capsulotomy cases was the highest with MI60. The cumulative rate of Nd:YAG laser capsulotomy during the first 3 years was 4.90% with SN60WF (70/1431 eyes), 6.76% with ZCB00 (43/636 eyes), 8.94% with MX60 (11/123 eyes), and 26.10% with MI60 (144/552 eyes) lenses. Conclusions: The incidence of PCO is influenced by the material of the IOLs. The hydrophilic IOL was associated with a higher rate of Nd:YAG laser capsulotomy than the hydrophobic IOLs, with a shorter time to Nd:YAG laser capsulotomy.
Collapse
Affiliation(s)
| | | | | | | | | | - Jee Hye Lee
- Department of Ophthalmology, Sanggye Paik Hospital, Inje University College of Medicine, Seoul 01757, Republic of Korea; (Y.L.); (J.S.K.); (B.G.K.); (J.H.H.); (M.J.K.)
| |
Collapse
|
4
|
Agarwal S, Thornell E. YAG Capsulotomy Rates in Patients Following Cataract Surgery and Implantation of New Hydrophobic Preloaded Intraocular Lens in an Australian Cohort: 3-Year Results. Clin Ophthalmol 2023; 17:3637-3643. [PMID: 38026609 PMCID: PMC10680474 DOI: 10.2147/opth.s437537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 10/26/2023] [Indexed: 12/01/2023] Open
Abstract
Purpose To assess the risk of posterior capsular opacification (PCO) following implantation of the Clareon lens. Materials and Methods Retrospective analysis was performed for 484 consecutive eyes that had undergone phacoemulsification and implantation of a monofocal lens (CNA0T) between April 2018 and February 2020. Eyes with other ocular pathology that may affect outcomes, previous refractive surgery or eyes corrected for a near target were excluded. Incidence of PCO and YAG capsulotomy was recorded and regression analysis was performed to determine risk factors associated with PCO formation. Results Overall incidence of PCO following implantation of the CNA0T monofocal lens was 3.7% (18 eyes) at 1 year with 1.9% (9 eyes) undergoing YAG capsulotomy. At 3 years, 8.7% (42 eyes) had developed PCO and 4.1% (20 eyes) had undergone YAG capsulotomy cumulatively. Primary open angle glaucoma (POAG; OR = 6.53; 95% CI = 18.68, 2.28; P = 0.0005), age-related macular degeneration (AMD; OR = 2.35; 95% CI = 5.21, 1.06; P = 0.036), vitreomacular traction (VMT; OR = 7.32; 95% CI = 45.08, 1.19; P = 0.032), retinal vein occlusion (RVO; OR = 8.42; 95% CI = 38.99, 1.82; P = 0.006) and history of anti-VEGF therapy (OR = 3.22; 95% CI = 10.26, 1.01; P = 0.048) were positively associated with an increased risk of PCO. Conclusions Incidence of PCO requiring YAG capsulotomy was relatively low. However, certain co-morbidities were found to increase the risk of PCO development, most significantly POAG and RVO.
Collapse
Affiliation(s)
- Smita Agarwal
- Wollongong Eye Specialists, Wollongong, NSW, Australia
- Graduate School of Medicine, University of Wollongong, Wollongong, NSW, Australia
| | - Erin Thornell
- Wollongong Eye Specialists, Wollongong, NSW, Australia
| |
Collapse
|
5
|
Gao L, Zhou Y, Li N, Liu X, Cong F. Lens Epithelial Mesenchymal Transition and Long-Term Chronic Inflammation After Cataract Surgery. Ocul Immunol Inflamm 2023; 31:1724-1726. [PMID: 35708475 DOI: 10.1080/09273948.2022.2088567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 06/07/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE To report the potential effect of lens epithelial-mesenchymal transition (EMT) following lens capsular reopening in three patients with long term chronic intraocular inflammation and mildly elevated intraocular pressure. METHODS Observational study. RESULTS Although the three patients had different histories of eye surgery and had experienced a long process of diagnosis and treatment, they had the following similarities: 1) They had undergone cataract surgery; 2) All of them had capsular bag opening or reopening and unexplained intraocular inflammation and elevated intraocular pressure for a long time, even up to more than one year; 3) The inflammation was eventually disappeared following complete clearance of the EMT derived material. CONCLUSION Our findings highlight the critical role of EMT derived material and capsular bag reopening in long-term post cataract surgery inflammation and pseudophakic ocular hypertension, and complete clearance of EMT derived material with surgical intervention should be considered if necessary.
Collapse
Affiliation(s)
- Lei Gao
- Zhengda Guangming Eye Group, Weifang Eye Hospital, Weifang, P.R. China
- Zhengda Guangming International Eye Research Center, Qingdao University, Qingdao, P.R. China
| | - Yujuan Zhou
- Zhengda Guangming Eye Group, Weifang Eye Hospital, Weifang, P.R. China
| | - Na Li
- Zhengda Guangming Eye Group, Weifang Eye Hospital, Weifang, P.R. China
| | - Xiaoqian Liu
- Zhengda Guangming Eye Group, Weifang Eye Hospital, Weifang, P.R. China
| | - Fei Cong
- Zhengda Guangming Eye Group, Weifang Eye Hospital, Weifang, P.R. China
| |
Collapse
|
6
|
Chen X, Chen Y, Li C, Li J, Zhang S, Liang C, Deng Q, Guo Z, Guo C, Yan H. Glutaredoxin 2 protects lens epithelial cells from epithelial-mesenchymal transition by suppressing mitochondrial oxidative stress-related upregulation of integrin-linked kinase. Exp Eye Res 2023; 234:109609. [PMID: 37541331 DOI: 10.1016/j.exer.2023.109609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 07/09/2023] [Accepted: 07/30/2023] [Indexed: 08/06/2023]
Abstract
Glutaredoxin 2 (Grx2), a mitochondrial glutathione-dependent oxidoreductase, is crucial for maintaining redox homeostasis and cellular functions in the lens. The oxidative stress-induced epithelial-mesenchymal transition (EMT) of lens epithelial cells (LECs) is related to posterior capsule opacification. In this study, we investigated the effects of Grx2 on oxidative stress-induced EMT in LECs during posterior capsule opacification. We found that Grx2 expression was substantially decreased during the EMT of LECs and in a mouse model of cataract surgery. Deletion of Grx2 aggravated the generation of reactive oxygen species, including those that are mitochondria-derived, and promoted the proliferation and EMT of the LECs. This was reversed by Grx2 overexpression. In vivo, proteomic liquid chromatography-mass spectrometry analysis showed that integrin-linked kinase (ILK) was significantly upregulated in the lens posterior capsule of a Grx2 knockout (KO) mouse model. Compared with that of the wild-type group, the expression of ILK and EMT markers was increased in the Grx2 KO group which was reversed in the Grx2 knock-in group. Inhibition of ILK partially blocked Grx2 knockdown-induced EMT and prevented the increased phosphorylation of Akt and GSK-3β and the nuclear translocation of β-catenin in the Grx2 KO group. Finally, inhibition of the Wnt/β-catenin pathway partially blocked the Grx2 knockdown-induced EMT. In conclusion, we demonstrated that Grx2 protects LECs from oxidative stress-related EMT by regulating the ILK/Akt/GSK-3β axis.
Collapse
Affiliation(s)
- Xi Chen
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China; Xi'an Key Laboratory of Stem Cell and Regenerative Medicine, Institute of Medical Research, Northwestern Polytechnical University, Xi'an, 710068, Shaanxi, China
| | - Ying Chen
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China
| | - Chenshuang Li
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China; Department of Ophthalmology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, Shaanxi, China
| | - Jiankui Li
- Department of Gynecology & Obstetrics, NO. 960 Hospital of PLA, Jinan, 250000, Shandong, China
| | - Siqi Zhang
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China; Department of Ophthalmology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, Shaanxi, China
| | - Chen Liang
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China; Department of Ophthalmology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, Shaanxi, China
| | - Qi Deng
- Xi'an Key Laboratory of Stem Cell and Regenerative Medicine, Institute of Medical Research, Northwestern Polytechnical University, Xi'an, 710068, Shaanxi, China
| | - Zaoxia Guo
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China
| | - Chenjun Guo
- Department of Ophthalmology, Tangdu Hospital, Air Force Medical University, Xi'an, 710038, Shaanxi, China
| | - Hong Yan
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, Shaanxi, China; Xi'an Key Laboratory of Stem Cell and Regenerative Medicine, Institute of Medical Research, Northwestern Polytechnical University, Xi'an, 710068, Shaanxi, China; Department of Ophthalmology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, Shaanxi, China.
| |
Collapse
|
7
|
Nuijts RM, Bhatt U, Nanavaty MA, Roberts TV, Peterson R, Teus MA. Three-year multinational clinical study on an aspheric hydrophobic acrylic intraocular lens. J Cataract Refract Surg 2023; 49:672-678. [PMID: 36848238 PMCID: PMC10284131 DOI: 10.1097/j.jcrs.0000000000001173] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 01/23/2023] [Accepted: 02/16/2023] [Indexed: 03/01/2023]
Abstract
PURPOSE To present the results of a study investigating the 3-year effectiveness and safety of the Clareon single-piece intraocular lens (IOL). SETTING 19 multinational sites. DESIGN Prospective multicenter single-arm study. METHODS Patients were bilaterally implanted with Clareon IOLs. Assessments included uncorrected distance visual acuity, corrected distance visual acuity (CDVA), manifest refraction, tilt, decentration, applanation tonometry, and fundus examination, including glistenings and posterior capsule opacification (PCO) evaluation. The primary outcomes for effectiveness and safety were evaluated at 1 year and compared with ISO historical safety and performance endpoint (SPE) rates. Patients were followed for up to 3 years after implantation. RESULTS 424 eyes of 215 patients were implanted (n = 215 first eye, n = 209 second eye), and 183 patients completed the trial at 3 years (with 364 binocular and 1 monocular patient). At 1 year, the cumulative and persistent adverse event rates were below SPE targets, and 99.5% of eyes achieved a monocular CDVA of ≤0.3 logMAR (vs the SPE target of 92.5%). At 3 years, the mean monocular CDVA was -0.032, with 93.4% (341/365) of eyes achieving a CDVA of 0.1 logMAR or better, 100% of eyes presented with grade 0 glistenings ≤25 MV/mm 2 , and 92.9% of eyes (394/424) had either no PCO or clinically nonsignificant PCO. CONCLUSIONS This study supports the long-term safety and effectiveness of the Clareon IOL. The visual outcomes were excellent and stable over the 3-year study period, PCO rates were very low, and 100% of IOLs had grade 0 glistenings.
Collapse
Affiliation(s)
- Rudy M.M.A. Nuijts
- From the University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands (Nuijts); Vision Eye Institute, Melbourne, Victoria, Australia (Bhatt); Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty); Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia (Roberts); Vision Eye Institute, Sydney, New South Wales, Australia (Roberts); Alcon Laboratories LLC, Fort Worth, Texas (Peterson); Hospital Universitario Principe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain (Teus)
| | - Uday Bhatt
- From the University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands (Nuijts); Vision Eye Institute, Melbourne, Victoria, Australia (Bhatt); Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty); Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia (Roberts); Vision Eye Institute, Sydney, New South Wales, Australia (Roberts); Alcon Laboratories LLC, Fort Worth, Texas (Peterson); Hospital Universitario Principe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain (Teus)
| | - Mayank A. Nanavaty
- From the University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands (Nuijts); Vision Eye Institute, Melbourne, Victoria, Australia (Bhatt); Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty); Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia (Roberts); Vision Eye Institute, Sydney, New South Wales, Australia (Roberts); Alcon Laboratories LLC, Fort Worth, Texas (Peterson); Hospital Universitario Principe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain (Teus)
| | - Timothy V. Roberts
- From the University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands (Nuijts); Vision Eye Institute, Melbourne, Victoria, Australia (Bhatt); Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty); Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia (Roberts); Vision Eye Institute, Sydney, New South Wales, Australia (Roberts); Alcon Laboratories LLC, Fort Worth, Texas (Peterson); Hospital Universitario Principe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain (Teus)
| | - Rachael Peterson
- From the University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands (Nuijts); Vision Eye Institute, Melbourne, Victoria, Australia (Bhatt); Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty); Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia (Roberts); Vision Eye Institute, Sydney, New South Wales, Australia (Roberts); Alcon Laboratories LLC, Fort Worth, Texas (Peterson); Hospital Universitario Principe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain (Teus)
| | - Miguel A. Teus
- From the University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands (Nuijts); Vision Eye Institute, Melbourne, Victoria, Australia (Bhatt); Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty); Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia (Roberts); Vision Eye Institute, Sydney, New South Wales, Australia (Roberts); Alcon Laboratories LLC, Fort Worth, Texas (Peterson); Hospital Universitario Principe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain (Teus)
| |
Collapse
|
8
|
Titiyal JS, Basak SK, Shetty N, Mathur U, Padmanabhan P, Ganesh S, Dey A, Ramamurthy D. Twelve-Months Follow-Up Postmarket Study of a Hydrophobic Intraocular Lens Using a Preloaded Automated Injector in an Indian Population. Clin Ophthalmol 2022; 16:4215-4225. [PMID: 36561374 PMCID: PMC9767064 DOI: 10.2147/opth.s379054] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 11/08/2022] [Indexed: 12/23/2022] Open
Abstract
Purpose To assess real-world clinical outcomes and safety of the Clareon® intraocular lens (IOL) and AutonoMe® automated preloaded delivery system in an Indian population. Patients and methods This was a prospective, single-arm, multicenter, 12-month clinical study in patients aged ≥20 years with unilateral or bilateral cataracts. Surgery was performed by phacoemulsification followed by implantation of the Clareon monofocal IOL (CNA0T0). Monocular best-corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were assessed at 1 week and 1, 6, and 12 months after implantation. Posterior capsular opacification (PCO), surface haze, and glistenings were evaluated at all visits. Surgeons' satisfaction with automated injector system was also evaluated using a questionnaire. Safety was assessed by monitoring adverse events (AEs). Results A total of 151 eyes received the CNA0T0 IOL. Mean ± SD monocular BCDVA improved from 0.53±0.44 logMAR preoperatively to 0.00±0.08 logMAR at week 1 and -0.03±0.08 logMAR at 12 months after implantation. At 12 months, 137/137 (100%) of eyes achieved BCDVA of 0.3 logMAR or better. Mean ± SD monocular UCDVA was 0.78±0.40 logMAR preoperatively, 0.11±0.15 logMAR at week 1, and 0.08±0.13 logMAR at 12 months after implantation. At 12 months, 132/137 (96%) eyes achieved UCDVA of 0.3 logMAR or better. Serious intraoperative AEs were posterior capsule rupture (n=1) and ciliary zonular dehiscence (n=1). Surgeons reported that the automated preloaded device was more intuitive compared with other push- or screw-style preloaded injector systems. None of the eyes in this study presented surface haze; all were graded as 0 glistenings at all visits. No clinically significant PCO or neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomies were reported. Conclusion The hydrophobic IOL preloaded in an automated injector system provided good visual and refractive outcomes, as well as no surface haze and grade 0 glistenings. None of the patients required Nd:YAG capsulotomy.
Collapse
Affiliation(s)
- Jeewan S Titiyal
- Department of Cornea and Refractive Surgery, All India Institute of Medical Sciences, New Delhi, India,Correspondence: Jeewan S Titiyal, Department of Cornea and Refractive Surgery, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India, Email
| | - Samar K Basak
- Department of Cornea and Cataract Services, Disha Eye Hospitals, Kolkata, India
| | - Naren Shetty
- Department of Cataract and Refractive Services, Narayana Nethralaya, Bengaluru, India
| | - Umang Mathur
- Department of Ophthalmology, Dr. Shroff’s Charity Eye Hospital, New Delhi, India
| | | | - Sri Ganesh
- Department of Phaco and Refractive Surgery, Nethradhama Superspeciality Eye Hospital, Bengaluru, India
| | - Arindam Dey
- Alcon Laboratories (India) Private Ltd, Bengaluru, India
| | - Dandapani Ramamurthy
- Department of Cornea, Cataract and Refractive Services, The Eye Foundation, Coimbatore, India
| |
Collapse
|
9
|
Jandewerth T, Müller M, Kohnen T. How to … YAG-Kapsulotomie. DIE OPHTHALMOLOGIE 2022; 119:1164-1166. [PMID: 36380238 DOI: 10.1007/s00347-022-01752-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Tyll Jandewerth
- Klinik für Augenheilkunde, Goethe- Universität Frankfurt, Theodor- Stern- Kai 7, 60590, Frankfurt am Main, Deutschland.
| | - Michael Müller
- Klinik für Augenheilkunde, Goethe- Universität Frankfurt, Theodor- Stern- Kai 7, 60590, Frankfurt am Main, Deutschland
| | - Thomas Kohnen
- Klinik für Augenheilkunde, Goethe- Universität Frankfurt, Theodor- Stern- Kai 7, 60590, Frankfurt am Main, Deutschland
| |
Collapse
|
10
|
Oshika T, Sasaki N. One-year multicenter evaluation of a new hydrophobic acrylic intraocular lens with hydroxyethyl methacrylate in an automated preloaded delivery system. J Cataract Refract Surg 2022; 48:275-279. [PMID: 34261986 PMCID: PMC8865199 DOI: 10.1097/j.jcrs.0000000000000746] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 06/30/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess a single-piece monofocal hydrophobic acrylic intraocular lens (IOL) with hydroxyethyl methacrylate (HEMA) (Clareon) contained in automated preloaded delivery system (AutonoMe). SETTING 18 surgical sites in Japan. DESIGN Observational study. METHODS In patients undergoing phacoemulsification and IOL implantation of a new hydrophobic acrylic IOL using an automated injector, clinical data were collected preoperatively and at 1 day, 1 week, and 1 month, 6 months, and 12 months postoperatively. The degree of glistenings was graded on a 4-point scale. The surgeons rated usability and performance of the IOL delivery system on a 5-point scale. RESULTS The study enrolled 384 eyes of 384 patients, ranging in age from 41 to 93 (73.8 ± 8.2, mean ± SD) years. The percentage of eyes with corrected distance visual acuity of 20/25 or better at 1 day, 1 week, and 1 month, 6 months, and 12 months postoperatively was 82.6%, 91.9%, 92.8%, 96.6%, and 95.2%, respectively. Refractive error was within 1.0 diopter in approximately 90% of cases. No glistenings were found in all cases throughout the study period. The rate of Nd:YAG laser posterior capsulotomy was 0.9% at 1 year. The IOL delivery system received high ratings on its usability and performance by the surgeons. CONCLUSIONS The new hydrophobic acrylic IOL with HEMA showed excellent visual and refractive outcomes without developing glistenings throughout the 1-year study period. The surgeons gave high marks for usability and performance of the automated preloaded delivery system.
Collapse
|
11
|
Agarwal S, Thornell E. Comparison of Visual Outcomes and Patient Satisfaction Following Cataract Surgery with Two Monofocal Intraocular Lenses: Clareon® vs AcrySof® IQ Monofocal. Open Ophthalmol J 2021. [DOI: 10.2174/1874364102115010144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Aim:
This study aimed to compare the performance of two monofocal Intraocular Lenses (IOL) platforms.
Background:
The Clareon® Intraocular Lens (IOL) is a relatively new monofocal lens platform designed to improve postoperative results compared to other monofocal platforms.
Objective:
This study aimed to assess and compare the visual and refractive outcomes, and incidence of YAG capsulotomy of the Clareon® IOL and a standard non-preloaded AcrySof® monofocal IOL following contralateral implantation in patients undergoing cataract surgery.
Methods:
A total of 20 patients (40 eyes; 12 female, average age 72.8±6.4 years) who had undergone contralateral implantation of an AcrySof® IQ monofocal lens (SN60WF or SN6AT; Alcon; Texas, USA) and a Clareon®monofocal lens (CNAOT0; Alcon; Texas, USA) were selected. Uncorrected Distance Visual Acuity (UDVA), Contrast Sensitivity (CS), kinetic perimetry, and refraction were measured 1 month following the second surgery and subjective vision was measured 6 months following the second surgery using a quality-of-life questionnaire.
Results:
There was no difference in postoperative UDVA (P=0.94), CS (P>0.05), or refraction (P=0.64) between eyes that received the Clareon® and AcrySof® IQ lenses. Clareon® eyes had a higher incidence of glare/haloes and positive dysphotopsia while AcrySof® IQ eyes had a higher incidence of negative dysphotopsia. Patient satisfaction was similar between the groups (P=0.86), although 25% of patients reported more clarity in the eye that received the Clareon® lens. The incidence of posterior capsular opacification was low for both groups.
Conclusion:
Clareon® and AcrySof® IQ lenses perform similarly, providing good refractive, visual, and subjective outcomes. Clareon® is available as a preloaded lens option and may reduce PCO and the need for Nd: YAG capsulotomy.
Collapse
|
12
|
Almenara C, Bartol-Puyal FDA, Soriano D, Idoipe M, Chacón M, Méndez-Martínez S, Giménez G, Polo V. Comparison of posterior capsule opacification between Clareon CNA0T0 and Tecnis ZCB00 intraocular lenses. Eur J Ophthalmol 2021; 31:3355-3366. [PMID: 33522302 DOI: 10.1177/1120672121991718] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
INTRODUCTION The purpose is to compare posterior capsule opacification (PCO) and its impact on vision between Clareon CNA0T0 (Alcon) and Tecnis ZCB00 intraocular lenses (IOLs) (Johnson&Johnson) 1, 6, and 12 months after implantation. METHODS A prospective observational study was performed at the Nuestra Señora de Gracia Hospital (Zaragoza, Spain). Fifty eyes (50 patients) with Tecnis IOL (group 1) and 60 eyes (60 patients) with Clareon IOL (group 2) were enrolled. One, 6, and 12 months after age-related cataract surgery by five different surgeons, the following tests were performed: mesopic corrected distance visual acuity (CDVA), CSV1000-E test, KR-1W wavefront analyzer, OQAS II, Catquest-9SF questionnaire and mydriatic slit-lamp pictures. PCO intensity was quantified and the area of opacification was measured using ImageJ (NIH). RESULTS Mean age was 71.20 ± 6.79 years in group 1, and 71.73 ± 8.17 years in group 2 (p = 0.72); mean axial length was 23.46 ± 1.14 and 23.53 ± 0.91 mm, respectively (p = 0.72); mean IOL power was 21.69 ± 2.26 D and 21.28 ± 2.44 D, respectively (p = 0.37). One month after surgery there were differences in intensity of PCO (0.73 ± 0.60 and 1.05 ± 0.71, respectively, p = 0.02). Six months after surgery statistical differences were found in VA with 20% CS in mydriatic conditions (0.26 ± 0.21 logMAR (20/36) and 0.18 ± 0.17 logMAR (20/30), respectively, p = 0.04). Twelve months after surgery, no differences were detected between groups. As for the evolution of PCO within the Clareon group, high order aberrations (p < 0.05) and the Strehl ratio (p = 0.02) decreased. CONCLUSION There are no differences in slit-lamp pictures or visual function between both IOLs during the first 12 months after implantation.
Collapse
Affiliation(s)
- Cristina Almenara
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain
| | - Francisco de Asís Bartol-Puyal
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain
| | - Diana Soriano
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain
| | - Miriam Idoipe
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain
| | - María Chacón
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain
| | - Silvia Méndez-Martínez
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain
| | - Galadriel Giménez
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain
| | - Vicente Polo
- Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.,Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.,Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain.,Biotech Vision SLP, Spin-off Company, University of Zaragoza, Spain
| |
Collapse
|
13
|
Chen X, Yan H, Chen Y, Li G, Bin Y, Zhou X. Moderate oxidative stress promotes epithelial-mesenchymal transition in the lens epithelial cells via the TGF-β/Smad and Wnt/β-catenin pathways. Mol Cell Biochem 2021; 476:1631-1642. [PMID: 33417163 DOI: 10.1007/s11010-020-04034-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Accepted: 12/22/2020] [Indexed: 12/20/2022]
Abstract
The epithelial-mesenchymal transition (EMT) plays a significant role in fibrosis and migration of lens epithelial cells (LECs), and eventually induces posterior capsule opacification (PCO). In the past, it was generally believed that the TGF-β/Smad pathway regulates lens EMT. A recent study found that attenuated glutathione level promotes LECs EMT via the Wnt/β-catenin pathway, which suggests a more complex pathogenesis of PCO. To test the hypothesis, we used the mouse cataract surgery PCO model and tested both canonical Wnt/β-catenin and TGF-β/Smad signaling pathways. The results showed that both TGF-β/Smad and Wnt/β-catenin pathways were activated during the lens capsule fibrosis. Compared with the freshly isolated posterior capsule, the expression level of phosphorylated Smad2 was highest at day3 and then slightly decreased, but the expression level of Wnt10a gradually increased from day0 to day7. It shows that these two pathways are involved in the lens epithelium's fibrotic process and may play different roles in different periods. Subsequently, we established oxidative stress-induced EMT model in primary porcine lens epithelial cells and found that both the TGF-β/Smad and Wnt/β-catenin pathways were activated. Further study suggests that block Wnt/β-catenin pathway using XAV939 alone or block TGF-β/Smad pathway using LY2109761 could partially block pLECs fibrosis, but blocking Wnt/β-catenin and TGF-β/Smad pathway using combined XAV939 and LY2109761 could completely block pLECs fibrosis. In conclusion, this study demonstrates that both TGF-β/Smad and canonical Wnt/β-catenin pathways play a significant role in regulating epithelial-mesenchymal transformation of lens epithelial cells but might be in a different stage.
Collapse
Affiliation(s)
- Xi Chen
- Department of Ophthalmology, Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, China
| | - Hong Yan
- Shaanxi Eye Hospital, Affiliated Xi'an Fourth Hospital, Northwestern Polytechnical University, Xi'an, 710004, Shaanxi Province, China
| | - Ying Chen
- Shaanxi Eye Hospital, Affiliated Xi'an Fourth Hospital, Northwestern Polytechnical University, Xi'an, 710004, Shaanxi Province, China
| | - Guo Li
- Department of Ophthalmology, Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, China
| | - Yue Bin
- Department of Ophthalmology, First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Xiyuan Zhou
- Department of Ophthalmology, Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, China.
| |
Collapse
|
14
|
Negishi K, Masui S, Torii H, Nishi Y, Tsubota K. Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system. PLoS One 2020; 15:e0238366. [PMID: 32877454 PMCID: PMC7467255 DOI: 10.1371/journal.pone.0238366] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 08/15/2020] [Indexed: 01/11/2023] Open
Abstract
PURPOSE To investigate refractive stability and characterize corneal incision repair up to 3 months after implantation of a new hydrophobic acrylic intraocular lens (IOL) with hydroxyethylmethacrylate using a new automated IOL delivery system. METHODS This prospective case series included 50 eyes of 50 patients undergoing phacoemulsification and implantation of the Clareon® CNA0T0 IOL using the AutonoMe® automated delivery system in the Department of Ophthalmology, Keio University School of Medicine. The clinical data were collected from 46 eyes of 46 patients preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. Endothelial-side incision gaping, posterior incision retraction, and Descemet's membrane detachment were recorded as present or absent using anterior-segment optical coherence tomography postoperatively. RESULTS The uncorrected distance and corrected distance visual acuities improved and stabilized 1 week postoperatively. The anterior chamber depth was stable from 1 week postoperatively. The subjective refraction was stable from 1 day postoperatively. Descemet's membrane detachments and endothelial-side wound gaping were seen in 19 (41.3%) eyes and 34 (73.9%) eyes 1 day postoperatively and decreased gradually. Posterior incision retraction was seen in eight eyes (17.4%) on day 1 and increased to 19 eyes (41.3%) 3 months postoperatively. CONCLUSIONS The Clareon IOL had excellent refractive stability from day 1 postoperatively. The AutonoMe automated delivery system enables safe IOL implantation through a 2.4-mm corneal incision, although the wound required longer than 1 month to heal postoperatively.
Collapse
Affiliation(s)
- Kazuno Negishi
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- * E-mail:
| | - Sachiko Masui
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Hidemasa Torii
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Yasuyo Nishi
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
15
|
Bedar MS, Kellner U. [Clinical experience with the Clareon® IOL and the AutonoMe® implantation system]. Ophthalmologe 2020; 117:1100-1104. [PMID: 32112221 DOI: 10.1007/s00347-020-01075-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND The AutonoMe® implantation system with a preloaded, monofocal, aspherical, hydrophobic Clareon® intraocular lens (IOL) has recently become available. The aim of this analysis was the most comprehensive review of intraoperative and postoperative outcomes to date. METHODS Prospective evaluation of intraoperative features in all eyes scheduled to have cataract surgery with Clareon® IOL implantation using the AutonoMe® implantation system between December 2017 and September 2018 with follow-up at 4-6 weeks. Inclusion of all patients, regardless of comorbidities and accompanying ocular surgery. RESULTS A total of 391 eyes were evaluated for the intraoperative analysis and 144 eyes were evaluated for postoperative follow-up. There was one IOL-associated intraoperative complication in which the posterior haptic was not correctly loaded and should not have been implanted. The best corrected distance visual acuity (BCDVA) increased from a mean of 0.33 logMAR (SD 0.21) preoperatively to 0.09 logMAR (SD 0.21) postoperatively, independent of ocular comorbidities. The BCDVA in patients without ocular comorbidities increased from 0.27 logMAR (SD 0.13) preoperatively to 0.03 logMAR (SD 0.05) postoperatively. Using the SRK®/T formula 87.5% of all eyes had a refractive error of ≤0.5 D and 98.0% had a refractive error of ≤1 D 4-6 weeks after surgery. CONCLUSION This study showed that using the recommended safety guidelines, the AutonoMe® system enables safe implantation of the IOL. The Clareon® IOL showed good postoperative visual outcomes and refraction results using the SRK®/T formula.
Collapse
Affiliation(s)
- Mohammad Seleman Bedar
- AugenZentrum Siegburg, MVZ Augenärztliches Diagnostik & Therapiecentrum Siegburg GmbH, Europaplatz 3, 53721, Siegburg, Deutschland.
| | - Ulrich Kellner
- AugenZentrum Siegburg, MVZ Augenärztliches Diagnostik & Therapiecentrum Siegburg GmbH, Europaplatz 3, 53721, Siegburg, Deutschland
- RetinaScience, Bonn, Deutschland
| |
Collapse
|
16
|
Hillenmayer A, Wertheimer CM, Kassumeh S, von Studnitz A, Luft N, Ohlmann A, Priglinger S, Mayer WJ. Evaluation of posterior capsule opacification of the Alcon Clareon IOL vs the Alcon Acrysof IOL using a human capsular bag model. BMC Ophthalmol 2020; 20:77. [PMID: 32103739 PMCID: PMC7045627 DOI: 10.1186/s12886-020-01349-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 02/18/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Posterior capsule opacification (PCO) after cataract surgery is influenced by intraocular lens (IOL) design and material. The following is an ex vivo comparison of PCO between the Clareon vs. the AcrySof IOL in human capsular bags. METHODS Twenty cadaver capsular bags from 10 human donors were used, with the novel hydrophobic IOL (Clareon, CNA0T0) being implanted in one eye and the other eye of the same donor receiving the AcrySof IOL (SN60WF) following phacoemulsification cataract surgery. Five capsular bags of 3 donors served as controls without IOL. Cellular growth of lens epithelial cells was photo-documented daily. The primary endpoint was the time until full coverage of the posterior capsule by cells. Furthermore, immunofluorescence staining of capsular bags for the fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were performed. RESULTS The new Clareon IOL did not show any disadvantages in terms of days until full cell coverage of the posterior capsule in comparison to the AcrySof (p > 0.99). Both, the Clareon (p = 0.01, 14.8 days) and the AcrySof IOL (p = 0.005, 15.7 days) showed a slower PCO development in comparison to the control (8.6 days). The fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were equally distributed between the two IOLs and differed from the control. CONCLUSIONS A comparable performance has been found in the ex vivo formation of PCO between the two IOLs. Long-term clinical studies are necessary to reach final conclusions.
Collapse
Affiliation(s)
- Anna Hillenmayer
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Christian M Wertheimer
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Stefan Kassumeh
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Annabel von Studnitz
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Nikolaus Luft
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Andreas Ohlmann
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Siegfried Priglinger
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany
| | - Wolfgang J Mayer
- Cell and molecular biology research laboratory, Division of Ophthalmology, Ludwig-Maximilians-University Munich, Mathildenstrasse 8, 80336, Munich, Germany.
| |
Collapse
|