1
|
Hengerer FH, Auffarth GU, Conrad-Hengerer I. 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. Adv Ther 2024; 41:1481-1495. [PMID: 38363465 PMCID: PMC10960914 DOI: 10.1007/s12325-024-02788-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/17/2024] [Indexed: 02/17/2024]
Abstract
INTRODUCTION This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.
Collapse
Affiliation(s)
- Fritz H Hengerer
- David J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany.
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ina Conrad-Hengerer
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
2
|
Morita S, Sakanishi Y, Riyu I, Watanabe S, Ebihara N. Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma. PLoS One 2024; 19:e0297514. [PMID: 38315707 PMCID: PMC10843132 DOI: 10.1371/journal.pone.0297514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 12/29/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE The study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma. METHODS This single-center, retrospective comparative case series evaluated the medical records of patients who underwent iStent (comprising 1 stent) or inject W (comprising 2 stents) implantation with cataract surgery for primary open-angle glaucoma and normal tension glaucoma between January 2019 and March 2022. The 12-month post-operative efficacy outcomes included intraocular pressure (IOP), glaucoma medications, and survival analysis of the probability of success. "Failure" was defined as any of the following conditions compared to baseline: 1) IOP elevation, 2) increased glaucoma medication, or 3) IOP decline not exceeding 20% when glaucoma medication scores were comparable, and 4) need for additional glaucoma surgery. The safety outcomes included intra- and post-operative adverse events and changes in the best-corrected visual acuity and visual field. RESULTS The study comprised 55 eyes in the iStent and 105 in the inject W groups. At 12 months, treatment success was achieved in 66.0% of iStent and 78.4% of inject W eyes. The mean IOP was lower, and the percent reduction from baseline was equal in iStent-treated eyes (8.0% reduction, 14.8 mmHg to 13.7 mmHg, P<0.01) and inject W-treated eyes (11.9% reduction, 15.0 mmHg to 13.8 mmHg, P<0.01) (between-group comparison, P = 0.23). The mean medication burden decreased significantly from 2.5 to 1.1 for iStent (55.0% reduction, P<0.01) and 2.9 to 1.7 for iStent inject (46.8% reduction, P<0.01), with no significant differences between the two groups (P = 0.17). Both devices exhibited excellent safety. CONCLUSIONS Both devices significantly reduced IOP and glaucoma medication 12 months post-operatively. The outcome measures did not differ significantly between the two groups, and lower baseline IOP was predictive of surgical failure.
Collapse
Affiliation(s)
- Shuu Morita
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Yoshihito Sakanishi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Ikari Riyu
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Satoshi Watanabe
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Nobuyuki Ebihara
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| |
Collapse
|
3
|
Asaoka R, Nakakura S, Mochizuki T, Ishida A, Fujino Y, Ishii K, Obana A, Tanito M, Kiuchi Y. Which is More Effective and Safer? Comparison of Propensity Score-Matched Microhook Ab Interno Trabeculotomy and iStent Inject. Ophthalmol Ther 2023; 12:2757-2768. [PMID: 37548906 PMCID: PMC10441850 DOI: 10.1007/s40123-023-00777-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 07/17/2023] [Indexed: 08/08/2023] Open
Abstract
INTRODUCTION The purpose of this study was to compare the surgical outcomes between ab interno trabeculotomy (LOT) and iStent inject W implantation (iStent) both combined with cataract surgery, matching the background factors including age, intraocular pressure (IOP), medication score, central corneal thickness (CCT), and axial length. METHODS A total of 100 eyes from 75/79 patients with primary open-angle glaucoma were included in the LOT/iStent groups. The background factors were matched between the two groups using the propensity score. RESULTS There were no significant differences in age, IOP, medication score, CCT, and axial length, preoperatively. The postoperative medication scores were 1.3 ± 1.2 and 1.2 ± 1.2 in the LOT and iStent groups. The postoperative IOPs were 12.8 ± 2.8 and 13.1 ± 2.4 mmHg in the LOT and iStent groups, respectively. The changes in the medication score were - 0.64 ± 1.4 and - 0.44 ± 1.6 in the LOT and iStent groups, respectively. The changes in the IOP were - 2.1 ± 3.3 and - 1.5 ± 3.0 mmHg in the LOT and iStent groups, respectively. These values were not significantly different between the two groups. The postoperative IOP and changes in the IOP were significantly associated with preoperative IOP and CCT. There was no significant difference in the occurrence of postoperative complications (hyphema, 11.0% and 6.0%, and transient ocular hypertension, 8.0% and 5.0%, in the LOT and iStent groups, respectively). CONCLUSION LOT and iStent have similar surgical outcomes with sufficient safety. Postoperative IOP was significantly associated with preoperative IOP and CCT in both groups.
Collapse
Grants
- 19H01114 Ministry of Education, Science, Techonology, Sports and Cultrue of Japan
- 18KK0253 Ministry of Education, Science, Techonology, Sports and Cultrue of Japan
- 20K09784 Ministry of Education, Science, Techonology, Sports and Cultrue of Japan
- 20K18337 Ministry of Education, Science, Techonology, Sports and Cultrue of Japan
- Japan Glaucoma Society
Collapse
Affiliation(s)
- Ryo Asaoka
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-Ku, Hamamatsu City, Shizuoka, Japan.
- Seirei Christopher University, Shizuoka, Japan.
| | - Shunsuke Nakakura
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, Hyogo, Japan
| | - Tsukasa Mochizuki
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan
| | - Akiko Ishida
- Department of Ophthalmology, Faculty of Medicine, Shimane University, Shimane, Japan
| | - Yuri Fujino
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-Ku, Hamamatsu City, Shizuoka, Japan
- Department of Ophthalmology, Faculty of Medicine, Shimane University, Shimane, Japan
| | - Kaori Ishii
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-Ku, Hamamatsu City, Shizuoka, Japan
| | - Akira Obana
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-Ku, Hamamatsu City, Shizuoka, Japan
| | - Masaki Tanito
- Department of Ophthalmology, Faculty of Medicine, Shimane University, Shimane, Japan
| | - Yoshiaki Kiuchi
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
4
|
Kanda S, Fujishiro T, Karakawa A, Nakagawa S, Ishii K. Clinical Outcomes of Phacoemulsification in Japanese Patients Receiving First and Revised Second-Generation Trabecular Microbypass Stents. Asia Pac J Ophthalmol (Phila) 2023; 12:279-283. [PMID: 37171124 DOI: 10.1097/apo.0000000000000611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 03/28/2023] [Indexed: 05/13/2023] Open
Abstract
PURPOSE This study evaluated the effectiveness and safety of first and revised second-generation trabecular microbypass stent insertion [iStent (IS) and iStent inject W (IW)] in cataract surgery. DESIGN Single-center, retrospective, cohort study. METHODS The study included 176 eyes that received trabecular microbypass stents combined with cataract surgery at the Saitama Red Cross Hospital between September 2017 and September 2021. Patients were divided into IS and IW groups depending on the implant type. Demographic characteristics, intraocular pressure (IOP), and the number of antiglaucoma medications (Med) were analyzed preoperatively and 12 months postoperatively. In addition, postoperative complications were compared between the groups. RESULTS IS and IW were implanted in 86 eyes and 90 eyes, respectively. IOP and Med at 1, 3, 6, 9, and 12 months decreased significantly from baseline in both groups ( P = 0.04, P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, for IOP in the IS group; P = 0.02, P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, for IOP in the IW group; P = 0.03, P = 0.002, P < 0.001, P < 0.001, and P < 0.001, respectively, for Med in the IS group; and P < 0.001 for all time points for Med in the IW group). IOP did not vary significantly between the groups at 1, 3, 6, 9, and 12 months postoperatively. Med was significantly lower in IW than IS at 1, 3, 6, 9, and 12 months postoperatively ( P < 0.001, P < 0.001, P = 0.002, P = 0.002, and P = 0.002, respectively). Hyphema and IOP >30 mm Hg (spike) occurred in 1.2% and 4.4%, and 1.2% and 3.3% of patients in the IS and IW groups, respectively. The probability of successful discontinuation of medications at 12 months postoperatively was 10.5% and 41.1%, respectively ( P < 0.001). CONCLUSIONS Postoperative Med was significantly lower in the IW group. Simultaneous insertion of IW in patients with glaucoma requiring cataract surgery may be preferred to IS because it reduces the burden of Med.
Collapse
Affiliation(s)
- Satoru Kanda
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo, Tokyo, Japan
| | - Takashi Fujishiro
- The University of Tokyo Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Ayako Karakawa
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Suguru Nakagawa
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Kiyoshi Ishii
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
5
|
Deitz GA, Patnaik JL, Young CEC, Ertel MK, SooHoo JR, Seibold LK, Kahook MY, Pantcheva MB. Comparison of Outcomes of Phacoemulsification Combined with Endoscopic Cyclophotocoagulation, iStent, or Both in the Management of Open-Angle Glaucoma. Adv Ther 2023; 40:1444-1455. [PMID: 36692680 DOI: 10.1007/s12325-022-02409-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 12/15/2022] [Indexed: 01/25/2023]
Abstract
INTRODUCTION To compare outcomes of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco/ECP), first generation iStent implantation (phaco/iStent), or both (phaco/iStent/ECP) in patients with open-angle glaucoma. METHODS A retrospective chart review was performed on patients at the University of Colorado Department of Ophthalmology. Outcomes included intraocular pressure (IOP), medication use, best corrected visual acuity (BCVA), and surgical complications were analyzed. Success was defined as IOP reduction of ≥ 20% and/or reduction by at least one glaucoma medication. RESULTS A total of 394 eyes were included in the study. There were 170 eyes (43.1%) in the phaco/ECP group, 175 eyes (44.4%) in the phaco/iStent group, and 49 eyes (12.4%) in the phaco/iStent/ECP group. The mean pre-operative IOP was 15.9 mmHg for phaco/ECP, 15.8 mmHg for phaco/iStent, and 15.2 mmHg for phaco/iStent/ECP. At 24 months, the mean IOP was 13.7 mmHg (p < 0.0001), 14.2 mmHg (p = 0.0001), and 13.0 mmHg (p = 0.0007), respectively. The mean pre-operative number of glaucoma medications was 2.0 for phaco/ECP, 1.4 for phaco/iStent, and 2.2 for phaco/iStent/ECP and at 24 months post-surgery decreased to, 1.8 (p = 0.011), 0.9 (p < 0.0001), and 1.7 (p = 0.01), respectively. The success rate at 24 months was 54.4% for phaco/ECP, 75.3% for phaco/iStent, and 55.6% for phaco/iStent/ECP. CONCLUSION Phacoemulsification when combined with ECP, iStent, or both, lowered IOP and glaucoma medication reliance at 24 months. The success rate for phaco/iStent was significantly higher than phaco/ECP. When iStent was added to phaco/ECP, the success rate was higher at earlier postoperative visits compared to the phaco/ECP alone.
Collapse
Affiliation(s)
- Galia A Deitz
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA.
| | - Jennifer L Patnaik
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| | - Cara E Capitena Young
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| | - Monica K Ertel
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| | - Jeffrey R SooHoo
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| | - Leonard K Seibold
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| | - Malik Y Kahook
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| | - Mina B Pantcheva
- Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, 1675 Aurora Court, Aurora, CO, 80045, USA
| |
Collapse
|
6
|
Cantor L, Lindfield D, Ghinelli F, Świder AW, Torelli F, Steeds C, Dickerson Jr JE, Nguyen DQ. Systematic Literature Review of Clinical, Economic, and Humanistic Outcomes Following Minimally Invasive Glaucoma Surgery or Selective Laser Trabeculoplasty for the Treatment of Open-Angle Glaucoma with or Without Cataract Extraction. Clin Ophthalmol 2023; 17:85-101. [PMID: 36636619 PMCID: PMC9831079 DOI: 10.2147/opth.s389406] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/23/2022] [Indexed: 01/07/2023] Open
Abstract
Introduction Selective laser trabeculoplasty (SLT) and minimally invasive glaucoma surgery (MIGS) are increasingly used options for mild-to-moderate open-angle glaucoma (OAG) care. While most MIGS devices are indicated for use in combination with cataract surgery only, with phacoemulsification playing a role in lowering IOP, newer technologies can also be used as standalone glaucoma surgery. Methods This systematic literature review (SLR) aimed to assess the clinical, economic, and humanistic outcomes of MIGS and SLT for the treatment of OAG and was conducted according to PRISMA guidelines. Studies that assessed MIGS or SLT in at least one treatment arm versus any other glaucoma treatment in adults with mild-to-moderate OAG were included. Clinical, humanistic (health-related quality of life [HRQoL] and patient burden), and economic data were extracted, and the methodological quality of included studies was evaluated. Results A total of 2720 articles were screened, and 81 publications were included. Fifty-eight reported clinical outcomes. The majority assessed iStent or iStent inject (n=41), followed by OMNI (n=9), gonioscopy-assisted transluminal trabeculotomy (GATT) or the Kahook Dual Blade (KDB) (n=7), Hydrus (n=6), SLT (n=5), Xen Gel Stent (n=2), PreserFlo (n=1), and iTrack (n=1). IOP reduction was observed across prospective studies, varying from -31% to -13.7% at month 6 and from -39% to -11.4% at year 1 versus baseline. Most adverse events were transient and non-serious. Limited humanistic and economic data were identified. Conclusion Given their established efficacy and safety, there is a rationale for wider use of MIGS in mild-to-moderate OAG. Of the MIGS devices, iStent and OMNI have the largest clinical evidence base supporting their sustained effectiveness.
Collapse
Affiliation(s)
- Louis Cantor
- Eugene and Marilyn Glick Eye Institute, Indiana School of Medicine, Indianapolis, IN, USA
| | - Dan Lindfield
- Royal Surrey County Hospital, Guildford, England, UK
| | | | | | - Francesca Torelli
- Valid Insight, Macclesfield, England, UK,Correspondence: Francesca Torelli, Valid Insight, Ropewalks, Newton St, Macclesfield, SK11 6QJ, UK, Tel +44 203 750 9833 Ext 703, Email
| | | | - Jaime E Dickerson Jr
- Sight Sciences, Menlo Park, CA, USA,North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, USA
| | - Dan Q Nguyen
- Mid-Cheshire Hospitals NHS Foundation Trust, Crewe, UK
| |
Collapse
|
7
|
Effectiveness and Safety of iStent Infinite Trabecular Micro-Bypass for Uncontrolled Glaucoma. J Glaucoma 2023; 32:9-18. [PMID: 36260288 PMCID: PMC9722368 DOI: 10.1097/ijg.0000000000002141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 10/07/2022] [Indexed: 01/24/2023]
Abstract
PRCIS The iStent Infinite Trabecular Micro-Bypass System implanted in patients with open angle glaucoma (OAG) (uncontrolled by prior surgical or medical therapy) was effective in reducing mean diurnal intraocular pressure with a favorable safety profile. PURPOSE The purpose of this study is to evaluate safety and effectiveness of the iStent infinite Trabecular Micro-Bypass System in patients with OAG uncontrolled by prior surgical or medical therapy. DESIGN Prospective, multicenter, single-arm, open-label clinical trial. METHODS Implantation of iStent infinite (3 iStent inject W stents) was performed as a stand-alone surgical procedure in eyes with OAG uncontrolled by prior incisional or cilioablative surgeries or maximum tolerated medical therapy (MTMT). Prospectively declared effectiveness endpoints were proportion of eyes achieving ≥20% mean diurnal intraocular pressure (MDIOP) reduction from baseline at month 12 on the same or fewer intraocular pressure (IOP)-lowering medication classes (responder endpoint) and mean change in MDIOP from baseline at month 12. Safety parameters included visual acuity, slit-lamp and fundus examinations, gonioscopy, perimetry, surgical complications, and adverse events. RESULTS Seventy-two eyes of 72 patients (mean age 71.9 y) with preoperative mean medicated MDIOP of 23.4±2.8 mm Hg on a mean of 3.1±0.9 IOP-lowering medication classes were enrolled: 61 eyes with failed prior surgery/ies (Failed-Surgery subgroup) and 11 eyes uncontrolled on MTMT (MTMT subgroup). A total of 76.1% of all enrolled patients met the responder endpoint (73.4% Failed-Surgery, 90.9% MTMT), with mean reduction (SE) in MDIOP at month 12 of 5.9(0.6) mm Hg [5.5(0.7) mm Hg Failed-Surgery subgroup, 8.1(0.9) mm Hg MTMT subgroup]. For patients on the same or fewer medication(s) as baseline, 53.0% achieved ≥30% MDIOP reduction without surgical interventions/other events. Safety was favorable, with no explants, infection, or device-related interventions or hypotony. CONCLUSIONS iStent infinite stand-alone surgery achieved clinically significant IOP reduction and favorable safety in patients with OAG uncontrolled by prior therapy.
Collapse
|
8
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
9
|
Inatani M, Kohama I, Chu A. iStent Trabecular Micro-bypass Stent Implantation Combined with Phacoemulsification for Open-Angle Glaucoma: A 2-Year Post-marketing Surveillance Study in Japan. Adv Ther 2022; 39:4076-4093. [PMID: 35790641 PMCID: PMC9402767 DOI: 10.1007/s12325-022-02207-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/24/2022] [Indexed: 11/18/2022]
Abstract
Introduction We report 2-year outcomes after implantation of iStent trabecular micro-bypass stent with phacoemulsification, in Japanese patients with mild–moderate open-angle glaucoma (OAG). Methods This was a 24-month, prospective, longitudinal, observational, post-marketing study conducted between July 2017 and September 2020. Patients consisted of adults with OAG on antiglaucoma medications who had cataract surgery combined with one iStent implantation. Outcome measures included intraocular pressure (IOP), antiglaucoma medications, treatment success rates (defined as eyes having lower IOP with same or reduced number of medications from baseline, or same IOP with reduced number of medications from baseline, and not requiring secondary glaucoma surgeries postoperatively), and safety. Outcomes were analyzed in the overall cohort and in glaucoma subtypes: primary OAG, normal-tension glaucoma, and exfoliative glaucoma. Results Overall, 232 eyes were enrolled. At 24 months, mean ± standard deviation IOP decreased from 17.6 ± 4.0 mmHg preoperatively to 14.3 ± 3.0 mmHg (p < 0.05), and mean number of medications reduced from 2.2 ± 1.2 preoperatively to 0.7 ± 1.2 (p < 0.05). Similar trends were observed across glaucoma subtypes. In the overall cohort, 96.7%, 95.3%, and 93.7% of patients achieved treatment success at 6, 12, and 24 months, respectively. There were 67.6% medication-free eyes at 24 months compared to 3.2% medication-free eyes preoperatively (p < 0.0001). Safety profile was favorable over the 2-year period. Conclusions Following iStent implantation with phacoemulsification, clinically relevant and statistically significant reductions in IOP and number of medications were observed in Japanese eyes with OAG over 2 years, with favorable safety profile. These reductions were observed across all glaucoma subtypes. Supplementary Information The online version contains supplementary material available at 10.1007/s12325-022-02207-0.
Collapse
Affiliation(s)
- Masaru Inatani
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Eiheiji, Yoshida, Fukui, 910-1193, Japan.
| | | | - Alice Chu
- Glaukos Corporation, Singapore, Singapore
| |
Collapse
|
10
|
iStent inject Trabecular Micro-Bypass with or Without Cataract Surgery Yields Sustained 5-Year Glaucoma Control. Adv Ther 2022; 39:1417-1431. [PMID: 35113323 PMCID: PMC8918186 DOI: 10.1007/s12325-021-02039-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 12/23/2021] [Indexed: 11/05/2022]
Abstract
Introduction This study evaluated the 5-year effectiveness and safety of iStent inject® trabecular micro-bypass with or without cataract surgery (Combined or Standalone, respectively) in patients with open-angle glaucoma (OAG). Methods This prospective longitudinal case series included consecutive iStent inject cases from a single surgeon at a large German academic hospital. Intraocular pressure (IOP), medications, safety, and indicators of disease stability through 5 years were assessed in the Overall cohort and in subgroup analyses stratified by usage (Combined or Standalone). Results Preoperative mean IOP in the Overall cohort (n = 125) was 23.5 ± 6.2 mmHg on 2.68 ± 1.02 mean medications, reducing to 14.1 ± 1.8 mmHg on 0.77 ± 0.82 medications at 5 years (40% and 71% reductions, respectively; both p < 0.001). All but 1 eye (> 99%) were on medication(s) preoperatively, but 46% were medication-free at 5 years (p < 0.001). In Combined eyes (n = 81), mean IOP decreased by 39% (22.6 mmHg to 13.8 mmHg, p < 0.001) and medications by 69% (2.52 to 0.78, p < 0.001). In Standalone eyes, mean IOP reduced by 42% (25.3 mmHg to 14.6 mmHg, p < 0.001) and medications by 75% (2.98 to 0.74, p < 0.001). At final follow-up, 83% of eyes had achieved ≥ 20% IOP reduction, and all but 1 eye (> 99%) had the same or lower IOP versus preoperative; all eyes (100%) maintained or reduced their medication burden versus preoperative. Favorable safety included 0 intraoperative complications and 0 filtration surgeries through 5 years. Long-term indicators of disease stability (visual fields, retinal nerve-fiber layer thickness, and cup:disc ratio) were unchanged over the course of 5-year follow-up. Conclusions iStent inject produced significant and durable 5-year reductions in IOP (nearly 10-mmHg reduction) and medications (nearly 2-medication reduction), with stable disease parameters over time. Combined and Standalone subgroups had similar outcomes.
Collapse
|
11
|
Paletta Guedes RA, Gravina DM, Paletta Guedes VM, Chaoubah A. Standalone Implantation of 2-3 Trabecular Micro-Bypass Stents (iStent inject ± iStent) as an Alternative to Trabeculectomy for Moderate-to-Severe Glaucoma. Ophthalmol Ther 2022; 11:271-292. [PMID: 34825352 PMCID: PMC8770764 DOI: 10.1007/s40123-021-00424-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 11/01/2021] [Indexed: 12/04/2022] Open
Abstract
INTRODUCTION This retrospective consecutive study compared standalone implantation of multiple (2-3) trabecular micro-bypass stents (iStent inject ± iStent) (Multi-Stent group) vs trabeculectomy + mitomycin C (Trab group) in moderate to severe open-angle glaucoma (OAG). METHODS Eligible patients underwent Multi-Stent or Trab surgery from 2018 to 2020 and had at least 3-month follow-up; visual field mean deviation (VF MD) - 6 dB or worse; inadequate prior response to maximum medications ± laser procedures; and had trabeculectomy as their next planned intervention. Primary effectiveness, safety-adjusted treatment success, was defined as ≥ 20% intraocular pressure (IOP) reduction on the same or fewer medications, without clinically significant safety events (severe complications, secondary surgeries, reinterventions). Secondary effectiveness included mean IOP and medications; qualified and complete attainment of target IOP (≤ 21/18/15/12 mmHg and > 6 mmHg); health-economic and quality-of-life (QoL) measures; and 2-vs-3-stent subgroup analysis. RESULTS The baseline groups (n = 70 Multi-Stent/40 Trab) were similar: mean IOP (21.1 mmHg/22.3 mmHg); medications (2.87/3.10 medications); disease stage (30%/35% severe); VF MD (- 10.1 dB/- 10.4 dB); and mean last follow-up (LFU, 13.1 months/15.7 months) (all differences non-significant). Primary effectiveness: treatment success at LFU was 62.9% vs 30.0% in Multi-Stent vs Trab eyes, respectively (p = 0.001). Secondary effectiveness: At LFU in Multi-Stent vs Trab groups, respectively: mean IOP decreased by 31% to 14.2 mmHg (p < 0.001) vs by 43% to 12.5 mmHg (p < 0.001); mean medications decreased by 51% to 1.31 medications (p < 0.001) vs by 84% to 0.43 medications (p < 0.001). Multi-Stent eyes, compared to Trab eyes, had fewer visits ± reinterventions within 3 months (3.6 vs 6.1, p < 0.001); longer time to first reintervention (12.2 months vs 4.5 months, p = 0.01); fewer total reinterventions (0.26 vs 0.75, p = 0.006); and earlier lifting of postoperative restrictions (12.6 vs 32.1 days, p < 0.001). In 2-vs-3-stent analysis, there was a trend toward more 3-stent eyes achieving target IOP than 2-stent eyes. Visual fields remained stable in both Multi-Stent and Trab eyes. CONCLUSION Implanting 2-3 trabecular micro-bypass stents was a viable alternative to trabeculectomy for moderate-to-severe OAG, with clinically appropriate IOP/medication reductions and higher safety-adjusted treatment success vs trabeculectomy.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Brazil.
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil.
| | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil
| |
Collapse
|
12
|
Salimi A, Watt H, Harasymowycz P. Long-term outcomes of two first-generation trabecular micro-bypass stents (iStent) with phacoemulsification in primary open-angle glaucoma: eight-year results. EYE AND VISION 2021; 8:43. [PMID: 34782017 PMCID: PMC8594216 DOI: 10.1186/s40662-021-00263-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 10/11/2021] [Indexed: 02/06/2023]
Abstract
Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up. Methods This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events. Results A total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease. Conclusions Implantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression. Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00263-1.
Collapse
Affiliation(s)
- Ali Salimi
- Department of Ophthalmology, Faculty of Medicine, McGill University, Montreal, QC, Canada.,Montreal Glaucoma Institute, Montreal, QC, Canada
| | - Harrison Watt
- Faculty of Medicine, McGill University, Montreal, QC, Canada
| | - Paul Harasymowycz
- Montreal Glaucoma Institute, Montreal, QC, Canada. .,Department of Ophthalmology, University of Montreal, 4135 de Rouen, Montreal, QC, H1V1G5, Canada.
| |
Collapse
|