• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4596627)   Today's Articles (33)   Subscriber (49344)
For: Al-Farhan HM, Al-Otaibi WM. Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes. Clin Ophthalmol 2012;6:1037-43. [PMID: 22848145 PMCID: PMC3402126 DOI: 10.2147/opth.s32955] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
Number Cited by Other Article(s)
1
Şimşek C, Kaya C, Karalezli A. Comparison of Central Corneal Thickness Measurements with Four Different New Devices and Ultrasound Pachymetry. Turk J Ophthalmol 2022;52:318-323. [PMID: 36317802 PMCID: PMC9631500 DOI: 10.4274/tjo.galenos.2021.22465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
2
Guresh AM, Horvath SJ, Gemensky-Metzler A, Miller E, Yildiz V, Myers JV, Newbold GM. The effect of central corneal thickness on intraocular pressure values using various tonometers in the dog. Vet Ophthalmol 2021;24 Suppl 1:154-161. [PMID: 33616274 DOI: 10.1111/vop.12873] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 01/27/2021] [Accepted: 01/29/2021] [Indexed: 11/30/2022]
3
Mayali H, Altinisik M, Diri I, Ilker S, Kurt E, Kayikcioglu O. Comparison of Central Corneal Thickness Measurements by Contact and Non-contact Pachymetry Devices. J Curr Glaucoma Pract 2021;15:28-31. [PMID: 34393453 PMCID: PMC8322600 DOI: 10.5005/jp-journals-10078-1295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
4
Comparison of central corneal thickness in dogs measured by ultrasound pachymetry and ultrasound biomicroscopy. Vet J 2017;232:13-14. [PMID: 29428083 DOI: 10.1016/j.tvjl.2017.12.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Revised: 12/01/2017] [Accepted: 12/02/2017] [Indexed: 11/23/2022]
5
Jeong S, Kang S, Park S, Park E, Lim J, Nam T, Seo K. Comparison of corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and digital caliper in frozen canine corneas. Vet Ophthalmol 2017;21:339-346. [DOI: 10.1111/vop.12509] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
6
Wolfel AE, Pederson SL, Cleymaet AM, Hess AM, Freeman KS. Canine central corneal thickness measurements via Pentacam-HR® , optical coherence tomography (Optovue iVue® ), and high-resolution ultrasound biomicroscopy. Vet Ophthalmol 2017;21:362-370. [DOI: 10.1111/vop.12518] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
7
Ramasubramanian V, Glasser A. Distortion Correction of Visante Optical Coherence Tomography Cornea Images. Optom Vis Sci 2016;92:1170-81. [PMID: 26540477 DOI: 10.1097/opx.0000000000000725] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
8
Kim IG, Lee CE, Lee JS, Seo S, Lee KW. Utility of the Swept Source Optical Coherence Tomography for Measurements of Central Corneal Thickness. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2016. [DOI: 10.3341/jkos.2016.57.10.1542] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
9
Garza-León M, de la Parra-Colín P, Barrientos-Gutierrez T. Comparación de la medición del grosor corneal central medido con un nuevo equipo de tomografía con cámara de Scheimpflug y anillos de Plácido (Sirius®) y paquimetría ultrasónica en sujetos sanos. REVISTA MEXICANA DE OFTALMOLOGÍA 2015. [DOI: 10.1016/j.mexoft.2014.11.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]  Open
10
Khaja WA, Grover S, Kelmenson AT, Ferguson LR, Sambhav K, Chalam KV. Comparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan. Clin Ophthalmol 2015;9:1065-70. [PMID: 26109840 PMCID: PMC4472076 DOI: 10.2147/opth.s81376] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
11
Kuerten D, Plange N, Koch EC, Koutsonas A, Walter P, Fuest M. Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT. Graefes Arch Clin Exp Ophthalmol 2015;253:1105-9. [PMID: 25896108 DOI: 10.1007/s00417-015-2998-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 03/15/2015] [Accepted: 03/25/2015] [Indexed: 10/23/2022]  Open
12
Zhao HX, Zhang L, Guan WY. Difference in normal corneal thickness and curvature between Mongolian and Han nationalities. Int J Ophthalmol 2015;8:399-402. [PMID: 25938063 DOI: 10.3980/j.issn.2222-3959.2015.02.33] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Accepted: 07/28/2014] [Indexed: 11/02/2022]  Open
13
Gunay M, Celik G, Gunay BO, Dogru M, Gursoy T, Ovali HF. Central corneal thickness measurements in premature infants. Int J Ophthalmol 2014;7:496-500. [PMID: 24967198 DOI: 10.3980/j.issn.2222-3959.2014.03.20] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2013] [Accepted: 01/10/2014] [Indexed: 11/02/2022]  Open
14
Al Farhan HM. Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth. BMC Ophthalmol 2014;14:20. [PMID: 24564379 PMCID: PMC3936803 DOI: 10.1186/1471-2415-14-20] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Accepted: 02/14/2014] [Indexed: 11/21/2022]  Open
15
Al Farhan HM, Al Otaibi WM, Al Razqan HM, Al Harqan AA. Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy. BMC Ophthalmol 2013;13:73. [PMID: 24274022 PMCID: PMC4222699 DOI: 10.1186/1471-2415-13-73] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 11/22/2013] [Indexed: 11/10/2022]  Open
16
Sutton G, Lawless M, Hodge C. Laser in situ keratomileusis in 2012: a review. Clin Exp Optom 2013;97:18-29. [PMID: 23786377 DOI: 10.1111/cxo.12075] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2012] [Revised: 11/08/2012] [Accepted: 12/14/2012] [Indexed: 11/25/2022]  Open
17
Ursea R, Feng M, Urs R, RoyChoudhury A, Silverman RH. Comparison of artemis 2 ultrasound and Visante optical coherence tomography corneal thickness profiles. J Refract Surg 2012. [PMID: 23205905 DOI: 10.3928/1081597x-20121126-01] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next