1
|
Factors associated with changes in posterior corneal surface following photorefractive keratectomy. Graefes Arch Clin Exp Ophthalmol 2021; 259:3477-3483. [PMID: 34097113 DOI: 10.1007/s00417-021-05237-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 05/03/2021] [Accepted: 05/05/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE To identify factors associated with changes in the posterior cornea curvature following laser refractive surgery. MATERIALS AND METHODS This retrospective study included myopic astigmatic eyes that underwent PRK between January 2013 and December 2013 at Care-Vision Laser Centers, Tel-Aviv, Israel. The average posterior K was measured with the Sirius device at a radius of 3 mm from the center. The correlations between the surgical induced change in average posterior k and preoperative parameters such as central corneal thickness (CCT), refraction, Baiocchi Calossi Versaci index (BCV), ablation depth, percent tissue altered (PTA), and residual stroma bed (RSB) were analyzed. RESULTS A total of 280 eyes with a mean age of 24.9 ± 6.1 years (range, 18-47 years were included in this study. The mean PTA was 14.8 ± 6.0%. A greater change in posterior K was found in females (p = 0.01), smaller treatment zones of 6.0 mm (p = 0.02) and PTA > 20% (p < 0.001). A lower CCT (r = - 0.24, p < 0.001), higher myopia (r = - 0.34, p < 0.001), higher astigmatism (r = - 0.17, p < 0.001), higher total BCV (r = 0.13, p = 0.03), lower back BCV (r = - 0.12, p = 0.05), higher front BCV (r = 0.16, p = 0.01), higher posterior I-S ratio (r = 0.16, p = 0.01), and a lower RSB (r = - 0.42, p < 0.001) were all significantly correlated with percentage of change in mean posterior K. In ranked stepwise multiple regression analysis, 26.2% of the variance of change in posterior K could be explained by the examined factors. The factors that remained significant were PTA (p < 0.001), CCT (p = 0.001), and posterior I-S ratio (p = 0.001). PTA alone accounted for 15% of the variance in posterior K changes in multivariate analysis. CONCLUSIONS Understanding of factors affecting a change in posterior cornea after refractive surgery may have an important practical value for the prevention of iatrogenic keratectasia. Preoperative CCT, posterior I-S ratio, and PTA were significantly associated with changes in posterior K after PRK. PTA was the strongest predictor of posterior corneal changes (p < 0.001).
Collapse
|
2
|
Jin Y, McAlinden C, Sun Y, Wen D, Wang Y, Yu J, Feng K, Song B, Wang Q, Chen S, Huang J. Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis. EYE AND VISION 2021; 8:5. [PMID: 33602345 PMCID: PMC7891160 DOI: 10.1186/s40662-021-00227-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 01/13/2021] [Indexed: 11/26/2022]
Abstract
Background To compare the difference in central corneal thickness (CCT) measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer (Sirius, CSO, Italy) and ultrasound pachymetry (USP). Methods A systematic literature search was conducted for relevant studies published on PubMed, Medline, EMBASE, and the Cochrane Library and ClinicalTrials.gov from inception to August 1st, 2019. Primary outcome measures were CCT measurements between Sirius and USP. A random effects model was used to pool CCT measurements. Results A total of twelve studies involving 862 eyes were included in this meta-analysis. The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different (P < 0.0001). The mean difference between Sirius and USP was −11.26 μm with a 95% confidence interval (CI) (−16.92 μm, −5.60 μm). The heterogeneity was I2 = 60% (P = 0.004). Conclusion CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP. However, it may be argued that the mean difference of 11.26 μm is not a clinically significant difference.
Collapse
Affiliation(s)
- Yili Jin
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Colm McAlinden
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.,Department of Ophthalmology, Singleton Hospital, Swansea Bay University Health Board, Swansea, UK
| | - Yong Sun
- Shenzhen Hospital of Integrated Traditional and Western Medicine, Shenzhen, China
| | - Daizong Wen
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Yiran Wang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Jinjin Yu
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Ke Feng
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Benhao Song
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Qinmei Wang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.,Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Shihao Chen
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China. .,Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China. .,Eye Hospital of Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, 325027, Zhejiang, China.
| | - Jinhai Huang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China. .,Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China. .,Eye Hospital of Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, 325027, Zhejiang, China.
| |
Collapse
|
3
|
Ozyol E, Özyol P. Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology. Indian J Ophthalmol 2017. [PMID: 28643709 PMCID: PMC5508455 DOI: 10.4103/ijo.ijo_618_16] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Purpose: The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. Materials and Methods: In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-domain OCT (SD-OCT) device with an anterior segment module (Spectralis), and noncontact pachymetry (NCP) device (Topcon TRK-2P). Agreement among the devices was analyzed using mean differences (i.e., bias) and Bland–Altman analysis with 95% limits of agreement (LoA). Results: Mean CCT measurements were 537.5 ± 47.5 μm for SS-OCT optical biometer, 532.3 ± 43.8 μm for Scheimpflug system, 521.3 ± 44.7 μm for SD-OCT device, and 518.0 ± 43.1 μm for NCP (P < 0.001). The SD-OCT device and NCP showed the closest agreement, with a bias of 2.6 μm (95% LoA, −3.6–8.8 μm), whereas the SS-OCT optical biometer and NCP showed the least agreement, with a bias of 18.7 μm (95% LoA, −2.1–39.5 μm). Bias was 16.1 μm (95% LoA, −3.1–35.3 μm) for SS-OCT optical biometer and SD-OCT, 5.1 μm (95% LoA, −6.8–17.0 μm) for SS-OCT optical biometer and Scheimpflug system, 10.9 μm (95% LoA, −15.1–36.9 μm) for SD-OCT device and Scheimpflug system, and 13.6 μm (95% LoA, −5–32.2 μm) for Scheimpflug system and NCP. Conclusions: SS-OCT optical biometer overestimates CCT measurements compared to Scheimpflug system, SD-OCT device, and NCP. Given mean differences and range variations in CCT measurements between devices, SS-OCT optical biometer and Scheimpflug system are interchangeable as are SD-OCT and NCP.
Collapse
Affiliation(s)
- Erhan Ozyol
- Department of Ophthalmology, Mugla Sitki Kocman University Training and Research Hospital, Muğla, Turkey
| | - Pelin Özyol
- Department of Ophthalmology, Faculty of Medicine, Mugla Sitki Kocman University, Muğla, Turkey
| |
Collapse
|
4
|
Applications of Scheimpflug Imaging in Glaucoma Management: Current and Potential Applications. J Ophthalmol 2016; 2016:3062381. [PMID: 28044101 PMCID: PMC5164893 DOI: 10.1155/2016/3062381] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 09/06/2016] [Accepted: 10/04/2016] [Indexed: 11/24/2022] Open
Abstract
Scheimpflug photography is the basis for a variety of imaging devices that are highly versatile. The applications of Scheimpflug imaging are wide in scope, spanning from evaluation of corneal ectasia to quantifying density in nuclear sclerotic cataracts. The potential uses for Scheimpflug-based devices are expanding and a number of them are relevant in glaucoma. In particular, they can provide three-dimensional image reconstruction of the anterior segment which includes assessment of the iridocorneal angle. Photographic analyses allow also for a noncontact method of estimating central corneal thickness (CCT) and intraocular pressure (IOP), as well as the study of various corneal biomechanical properties, which may be useful for stratifying glaucoma risk.
Collapse
|
5
|
Şimşek A, Bilgin B, Çapkın M, Bilak Ş, Güler M, Reyhan AH. Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification. KOREAN JOURNAL OF OPHTHALMOLOGY 2016; 30:251-7. [PMID: 27478351 PMCID: PMC4965599 DOI: 10.3341/kjo.2016.30.4.251] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Accepted: 10/12/2015] [Indexed: 11/23/2022] Open
Abstract
Purpose To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. Methods A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. Results The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm3, 42.09 ± 7.490, 523.87 ± 41.97 microns, 55.37 ± 4.89 mm3, 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm3, 51.46 ± 5.630, 526.21 ± 44.45 microns, 56.23 ± 5.12 mm3, 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p < 0.05). CCT remained stable after surgery. Postoperative PD and IOP were significantly decreased compared to corresponding preoperative values (p < 0.05). Conclusions Preoperative measurements by the Sirius 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a noncontact, noninvasive, and comfortable system for patients that is highly reliable and repeatable for anterior segment measurements.
Collapse
Affiliation(s)
- Ali Şimşek
- Department of Ophthalmology, Adıyaman University School of Medicine, Adiyaman, Turkey
| | - Burak Bilgin
- Department of Ophthalmology, Adıyaman Gozde Hospital, Adiyaman, Turkey
| | - Musa Çapkın
- Department of Ophthalmology, Adıyaman University School of Medicine, Adiyaman, Turkey
| | - Şemsettin Bilak
- Department of Ophthalmology, Adıyaman University School of Medicine, Adiyaman, Turkey
| | - Mete Güler
- Department of Ophthalmology, Adıyaman University School of Medicine, Adiyaman, Turkey
| | - Ali Hakim Reyhan
- Department of Ophthalmology, Adıyaman University School of Medicine, Adiyaman, Turkey
| |
Collapse
|
6
|
Evaluation of Central Corneal Thickness Using Corneal Dynamic Scheimpflug Analyzer Corvis ST and Comparison with Pentacam Rotating Scheimpflug System and Ultrasound Pachymetry in Normal Eyes. J Ophthalmol 2015; 2015:767012. [PMID: 26697213 PMCID: PMC4678087 DOI: 10.1155/2015/767012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Accepted: 11/16/2015] [Indexed: 11/25/2022] Open
Abstract
Purpose. To assess the repeatability and reproducibility of central corneal thickness (CCT) measurements by corneal dynamic Scheimpflug analyzer Corvis ST in normal eyes and compare the agreement with Pentacam rotating Scheimpflug System and ultrasound pachymetry. Methods. 84 right eyes underwent Corvis ST measurements performed by two operators. The test-retest repeatability (TRT), within-subject coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were used to evaluate the intraoperator repeatability and interoperator reproducibility. CCT measurements also were obtained from Pentacam and ultrasound pachymetry by the first operator. The agreement between the three devices was evaluated with 95% limits of agreement (LoA) and Bland-Altman plots. Results. Corvis ST showed high repeatability as indicated by TRT ≤ 13.0 μm, CoV < 0.9%, and ICC > 0.97. The interoperator reproducibility was also excellent. The CoV was <0.9%, and ICC was >0.97. Corvis ST showed significantly lower values than Pentacam and ultrasound pachymetry (P < 0.001). The 95% LoA between Corvis ST and Pentacam or ultrasound pachymetry were −15.8 to 9.5 μm and −27.9 to 12.3 μm, respectively. Conclusions. Corvis ST showed excellent repeatability and interoperator reproducibility of CCT measurements in normal eyes. Corvis ST is interchangeable with Pentacam but not with ultrasound pachymetry.
Collapse
|
7
|
Kuerten D, Plange N, Koch EC, Koutsonas A, Walter P, Fuest M. Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT. Graefes Arch Clin Exp Ophthalmol 2015; 253:1105-9. [PMID: 25896108 DOI: 10.1007/s00417-015-2998-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 03/15/2015] [Accepted: 03/25/2015] [Indexed: 10/23/2022] Open
Abstract
PURPOSE The purpose of this study is to determine the influence of post-surgical corneal edema on the reliability and reproducibility of central corneal thickness (CCT) measurements by a Scheimpflug camera (Pentacam), ultrasound pachymetry (USP), and anterior-segment spectral-domain optical coherence tomography (AS-OCT). METHODS Thirty-two patients planned for cataract surgery (n = 16) or vitrectomy (n = 6) were included in a prospective study. The non-surgery eye was used as control. Two investigators acquired two measurements each, with the Pentacam (Oculus, Germany) and the AS-OCT (Heidelberg Engineering, Germany) in a randomized order, followed by USP (Tomey SP-100, Germany). CCT was evaluated using the apex value for Pentacam, the corneal apex cut in AS-OCT and averaging eight single measurements for USP. Coefficients of variation (COV) and intra-class correlation coefficients (ICC) were determined. RESULTS Post-surgery corneas showed a thickness of (investigators 1 and 2): Pentacam (615.9 ± 58.02 μm and 615.1 ± 60.17 μm), USP (601.4 ± 63.77 μm and 614.5 ± 70.91 μm), AS-OCT (608.8 ± 65.67 μm and 606.9 ± 64.41 μm) ,with no significant difference (ANOVA p > 0.99). The COVs (investigators 1 and 2) for control eyes were: Pentacam (0.78 ± 0.52 and 0.70 ± 0.76), USP (0.66 ± 0.29 and 0.98 ± 0.44), AS-OCT (0.59 ± 0.61 and 0.59 ± 0.40). The COVs (investigators 1 and 2) for post-surgical eyes were: Pentacam (0.98 ± 1.25 and 0.97 ± 0.73), USP (0.73 ± 0.64 and 1.35 ± 0.85), AS-OCT (1.34 ± 1.57 and 1.19 ± 1.18).The ICC was determined in post-surgery corneas (ICC > 0.96) and control corneas (ICC > 0.95). CONCLUSION USP measurements have the highest user dependence. Post-surgical corneal edema leads to higher intraobserver variability. All methods reached a high level of agreement in CCT determination in edematous as well as healthy corneas.
Collapse
Affiliation(s)
- David Kuerten
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany,
| | | | | | | | | | | |
Collapse
|
8
|
Precision of corneal thickness measurements obtained using the scheimpflug-placido imaging and agreement with ultrasound pachymetry. J Ophthalmol 2015; 2015:328798. [PMID: 25810919 PMCID: PMC4355121 DOI: 10.1155/2015/328798] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Accepted: 02/09/2015] [Indexed: 11/18/2022] Open
Abstract
Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by 1 operator using the TMS-5, 3 additional consecutive scans were performed by a second operator, and ultrasound (US) pachymetry measurements were taken. The test-retest repeatability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability and interoperator reproducibility. Agreement among the devices was assessed using Bland-Altman plots and 95% limits of agreement (LoA). Results. The intraoperators TRT and CoV were <19 μm and 2.0%, respectively. The interoperators TRT and CoV were <12 μm and 1.0%, respectively, and ICC was >0.90. The mean CCT and TCT measurements using the TMS-5 were 15.97 μm (95% LoA from −26.42 to −5.52 μm) and 20.32 μm (95% LoA from −30.67 to −9.97 μm) smaller, respectively, than those using US pachymetry. Conclusions. The TMS-5 shows good repeatability and reproducibility for measuring CCT and TCT in normal subjects but only moderate agreement with US pachymetry results. Caution is warranted before using these techniques interchangeably.
Collapse
|
9
|
Evaluation of corneal topography and biomechanical parameters after use of systemic isotretinoin in acne vulgaris. J Ophthalmol 2014; 2014:701361. [PMID: 25525510 PMCID: PMC4265706 DOI: 10.1155/2014/701361] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2014] [Accepted: 11/03/2014] [Indexed: 11/18/2022] Open
Abstract
Purpose. We report the effect of isotretinoin on corneal topography, corneal thickness, and biomechanical parameters in patients with acne vulgaris. Method. Fifty-four eyes of 54 patients who received oral isotretinoin for treatment of acne vulgaris were evaluated. All patients underwent a corneal topographical evaluation with a Scheimpflug camera combined with Placido-disk (Sirius), ultrasonic pachymetry measurements, and corneal biomechanical evaluation with an ocular response analyzer at baseline, in the 1st, 3rd, and 6th months of treatment, and 6 months after isotretinoin discontinuation. Results. The thinnest corneal thickness measured with Sirius differed significantly in the 1st, 3rd, and 6th months compared with the baseline measurement; there was no significant change in ultrasonic central corneal thickness measurements and biomechanical parameters (corneal hysteresis and corneal resistance factor) throughout the study. Average simulated keratometry and surface asymmetry index increased significantly only in the first month of treatment according to the baseline. All changes disappeared 6 months after the end of treatment. Conclusion. Basal tear secretion and corneal morphologic properties were significantly influenced during the systemic isotretinoin treatment and the changes were reversible after discontinuation. No statistical important biomechanical differences were found to be induced by isotretinoin.
Collapse
|
10
|
Correlation analysis between central corneal thickness and intraocular pressure in juveniles in Northern China: the Jinan city eye study. PLoS One 2014; 9:e104842. [PMID: 25148520 PMCID: PMC4141688 DOI: 10.1371/journal.pone.0104842] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Accepted: 07/15/2014] [Indexed: 12/27/2022] Open
Abstract
Purpose To determine the distributions and relation of central corneal thickness (CCT) and intraocular pressure (IOP) by NT-530P in Chinese juveniles, and the effect of gender, age, height, weight and refractive errors on the CTT and IOP. Methods CCT and IOP of 982 eyes in 514 juveniles aged from 7 to 18 years were measured with NT-530P. Multi-linear regression and ANOVA analysis were used to analyze the relation of CCT and IOP, and the effect of gender, age, height, weight, refractive condition on CCT and IOP respectively. Results The mean CCT and IOP were 554.19±35.46 µm and 15.31±2.57 mmHg. There were significant correlations between the CCT and IOP values. Linear regression analysis revealed a positive correlation between CCT and IOP (r = 0.44, P<0.05). Linear regression equation: IOP = −2.35+0.032CCT, which means the IOP will increase 0.32 mm Hg for every 10-µm increase in CCT. The mean of Corrected IOP (CIOP) was 15.32±2.38 mmHg and had no relation with CCT. There was a negative correlation between refraction degree and CCT (P<0.05), but no correlation between refraction degree and IOP. Multi-linear regression model revealed that the height, weight, age and gender have no effect on the distribution of CCT and IOP respectively. Conclusions There is a 0.32 mmHg increase in IOP for every 10-µm increase in CCT. The height, weight, age and gender has no effect on the distribution of CCT and IOP. CCT will become thinner with myopia diopters increases in juveniles. The measurement of CCT is helpful in evaluating the actual IOP correctly.
Collapse
|