1
|
Guo Y, Sivakumar M, Jiang G. Decay of four enteric pathogens and implications to wastewater-based epidemiology: Effects of temperature and wastewater dilutions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 819:152000. [PMID: 34843787 DOI: 10.1016/j.scitotenv.2021.152000] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 06/13/2023]
Abstract
Measurement of pathogens in raw wastewater from a population within certain sewer catchments can provide quantitative information on public health status within the sampled urban area. This so-called wastewater-based epidemiology (WBE) approach has the potential of becoming a powerful tool to monitor pathogen circulation and support timely intervention during outbreaks. However, many WBE studies failed to account for the pathogen decay during wastewater transportation in back calculating the disease prevalence. Various sewer process factors, including water temperature and infiltration/inflow, can lead to the variation of pathogen decay rates. This paper firstly reviewed the effects of temperature and types of water, i.e., wastewater, freshwater, and saline water, on the decay of four selected enteric pathogens, i.e., Campylobacter, Salmonella, Norovirus, and Adenovirus. To elucidate the importance of the pathogen decay rates (measured by culture and molecular methods) to WBE, a sensitivity analysis was conducted on the back-calculation equation for infection prevalence with decay rates collected from published literature. It was found that WBE back-calculation is more sensitive to decay rates under the condition of high wastewater temperature (i.e., over 25 °C) or if wastewater is diluted by saline water (i.e., sewer infiltration or use of seawater as an alternative source of freshwater constituting around 1/3 household water demand in some cities). Stormwater dilution of domestic wastewater (i.e., sewer inflow might achieve 10 times volumetric dilution) was shown to play a role in increasing the sensitivity of WBE back-calculation to bacterial pathogens, but not viral pathogens. Hence, WBE back-calculation in real sewers should account for in-sewer decay of specific pathogen species under different wastewater temperatures and dilutions. Overall, this review contributes to a better understanding of pathogen decay in wastewater which can lead to improved accuracy of WBE back-calculation.
Collapse
Affiliation(s)
- Ying Guo
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, Australia
| | - Muttucumaru Sivakumar
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, Australia
| | - Guangming Jiang
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, Australia; Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia.
| |
Collapse
|
2
|
Automated Targeted Sampling of Waterborne Pathogens and Microbial Source Tracking Markers Using Near-Real Time Monitoring of Microbiological Water Quality. WATER 2021. [DOI: 10.3390/w13152069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Waterborne pathogens are heterogeneously distributed across various spatiotemporal scales in water resources, and representative sampling is therefore crucial for accurate risk assessment. Since regulatory monitoring of microbiological water quality is usually conducted at fixed time intervals, it can miss short-term fecal contamination episodes and underestimate underlying microbial risks. In the present paper, we developed a new automated sampling methodology based on near real-time measurement of a biochemical indicator of fecal pollution. Online monitoring of β-D-glucuronidase (GLUC) activity was used to trigger an automated sampler during fecal contamination events in a drinking water supply and at an urban beach. Significant increases in protozoan parasites, microbial source tracking markers and E. coli were measured during short-term (<24 h) fecal pollution episodes, emphasizing the intermittent nature of their occurrence in water. Synchronous triggering of the automated sampler with online GLUC activity measurements further revealed a tight association between the biochemical indicator and culturable E. coli. The proposed event sampling methodology is versatile and in addition to the two triggering modes validated here, others can be designed based on specific needs and local settings. In support to regulatory monitoring schemes, it should ultimately help gathering crucial data on waterborne pathogens more efficiently during episodic fecal pollution events.
Collapse
|
3
|
Hinojosa J, Green J, Estrada F, Herrera J, Mata T, Phan D, Pasha ABMT, Matta A, Johnson D, Kapoor V. Determining the primary sources of fecal pollution using microbial source tracking assays combined with land-use information in the Edwards Aquifer. WATER RESEARCH 2020; 184:116211. [PMID: 32721766 DOI: 10.1016/j.watres.2020.116211] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 07/18/2020] [Accepted: 07/20/2020] [Indexed: 06/11/2023]
Abstract
The Edwards Aquifer serves as a primary source of drinking water to more than 2 million people in south-central Texas, and as a karst aquifer, is vulnerable to human and animal fecal contamination which poses a serious risk to human and environmental health. A one-year study (Jan 2018 - Feb 2019) was conducted to determine the primary sources of fecal pollution along the Balcones and Leon Creek within the Edwards Aquifer recharge and contributing zones using general (E. coli, enterococci, and universal Bacteriodales) and host-associated (human-, dog-, cow- and chicken/duck-associated Bacteriodales) microbial source tracking (MST) assays. Additionally, sites were classified based on surrounding land use as a potential source predictor and marker levels were correlated with rain events and water quality parameters. Levels for the three general indicators were highest and exhibited similar trends across the sampling sites, suggesting that the sole use of these markers is not sufficient for specific fecal source identification. Among the host-associated markers, highest concentrations were observed for the dog marker (BacCan) in the Leon Creek area and the cow marker (BacCow) in the Balcones Creek area. Additionally, Chicken/Duck-Bac, BacCan and BacCow all exhibited higher concentrations during the spring season and the end of fall/early winter. Relatively lower concentrations were observed for the human-associated markers (HF183 and BacHum), however, levels were higher in the Leon Creek area and highest following rainfall events. Additionally, relatively higher levels in HF183 and BacHum were observed at sites having greater human population and septic tank density and may be attributed to leaks or breaks in these infrastructures. This study is the first to examine and compare fecal contamination at rural and urban areas in the recharge and contributing zones of the Edwards Aquifer using a molecular MST approach targeting Bacteroidales 16S rRNA gene-based assays. The Bacteroidales marker assays, when combined with land use and weather information, can allow for a better understanding of the sources and fluxes of fecal contamination, which can help devise effective mitigation measures to protect water quality.
Collapse
Affiliation(s)
- Jessica Hinojosa
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Jemima Green
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Fabiola Estrada
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Jonathan Herrera
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Troy Mata
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Duc Phan
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - A B M Tanvir Pasha
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Akanksha Matta
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Drew Johnson
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Vikram Kapoor
- Department of Civil and Environmental Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA.
| |
Collapse
|
4
|
Nilsen V. Some aspects of deep-bed filtration dynamics in QMRA for drinking water. WATER RESEARCH 2020; 170:115365. [PMID: 31830654 DOI: 10.1016/j.watres.2019.115365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 11/17/2019] [Accepted: 12/01/2019] [Indexed: 06/10/2023]
Abstract
Unlike most unit processes in drinking water treatment, the performance of deep-bed filtration processes vary systematically on short time-scales; the particle removal capacity changes with time since the previous backwash, even when the influent water quality is stable. For microorganisms, the removal efficiency may vary by orders of magnitude. In this note, the potential impact of such dynamics on microbial risk estimates is studied, using representative experimental filtration data for viruses and bacteria in conjunction with single-hit dose-response models for microbial infection. Assuming that filtration is the only source of variation in pathogen concentrations on the time-scale of a single filter cycle, it is concluded that such variations are unlikely to substantially affect risk estimates, except possibly in an outbreak situation with extremely high pathogen concentrations; it is generally sufficient to know the mean pathogen concentrations. Future studies should include concurrent variation in the performance of other unit processes and raw water pathogen concentrations. Experimental work should focus on capturing the variation in filtration performance in order to correctly estimate mean removal rates.
Collapse
Affiliation(s)
- Vegard Nilsen
- Norwegian University of Life Sciences, Faculty of Science and Technology, P.O.Box 5003, N-1432, Ås, Norway.
| |
Collapse
|
5
|
Nappier SP, Hong T, Ichida A, Goldstone A, Eftim SE. Occurrence of coliphage in raw wastewater and in ambient water: A meta-analysis. WATER RESEARCH 2019; 153:263-273. [PMID: 30735956 PMCID: PMC7169987 DOI: 10.1016/j.watres.2018.12.058] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 12/21/2018] [Accepted: 12/22/2018] [Indexed: 05/20/2023]
Abstract
Coliphage have been proposed as indicators of fecal contamination in recreational waters because they better reflect the persistence of pathogenic viruses in the environment and through wastewater treatment than traditional fecal indicator bacteria. Herein, we conducted a systematic literature search of peer-reviewed publications to identify coliphage density data (somatic and male-specific, or MSC) in raw wastewater and ambient waters. The literature review inclusion criteria included scope, study quality, and data availability. A non-parametric two-stage bootstrap analysis was used to estimate the coliphage distributions in raw wastewater and account for geographic region and season. Additionally, two statistical methodologies were explored for developing coliphage density distributions in ambient waters, to account for the nondetects in the datasets. In raw wastewater, the analysis resulted in seasonal density distributions of somatic coliphage (SC) (mean 6.5 log10 plaque forming units (PFU)/L; 95% confidence interval (CI): 6.2-6.8) and MSC (mean 5.9 log10 PFU/L; 95% CI: 5.5-6.1). In ambient waters, 49% of MSC samples were nondetects, compared with less than 5% for SC. Overall distributional estimates of ambient densities of coliphage were statistically higher for SC than for MSC (mean 3.4 and 1.0 log10 PFU/L, respectively). Distributions of coliphage in raw wastewater and ambient water will be useful for future microbial risk assessments.
Collapse
Affiliation(s)
- Sharon P Nappier
- U.S. Environmental Protection Agency, Office of Water, Office of Science and Technology, 1200 Pennsylvania Avenue, NW, Washington, DC, 20460, USA.
| | - Tao Hong
- ICF, LLC, 9300 Lee Highway, Fairfax, VA, 22031, USA
| | | | | | | |
Collapse
|
6
|
Petterson SR, Ashbolt NJ. QMRA and water safety management: review of application in drinking water systems. JOURNAL OF WATER AND HEALTH 2016; 14:571-589. [PMID: 27441853 DOI: 10.2166/wh.2016.262] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Quantitative microbial risk assessment (QMRA), the assessment of microbial risks when model inputs and estimated health impacts are explicitly quantified, is a valuable tool to support water safety plans (WSP). In this paper, research studies undertaken on the application of QMRA in drinking water systems were reviewed, highlighting their relevance for WSP. The important elements for practical implementation include: the data requirements to achieve sufficient certainty to support decision-making; level of expertise necessary to undertake the required analysis; and the accessibility of tools to support wider implementation, hence these aspects were the focus of the review. Recommendations to support the continued and growing application of QMRA to support risk management in the water sector are provided.
Collapse
Affiliation(s)
- S R Petterson
- Water & Health Pty Ltd, PO Box 648, Salamander Bay 2317, Australia E-mail:
| | - N J Ashbolt
- School of Public Health, University of Alberta, Alberta, Canada T6G 2G7
| |
Collapse
|
7
|
Åström J, Pettersson TJR, Reischer GH, Norberg T, Hermansson M. Incorporating expert judgments in utility evaluation of bacteroidales qPCR assays for microbial source tracking in a drinking water source. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:1311-8. [PMID: 25545113 PMCID: PMC5509012 DOI: 10.1021/es504579j] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Several assays for the detection of host-specific genetic markers of the order Bacteroidales have been developed and used for microbial source tracking (MST) in environmental waters. It is recognized that the source-sensitivity and source-specificity are unknown and variable when introducing these assays in new geographic regions, which reduces their reliability and use. A Bayesian approach was developed to incorporate expert judgments with regional assay sensitivity and specificity assessments in a utility evaluation of a human and a ruminant-specific qPCR assay for MST in a drinking water source. Water samples from Lake Rådasjön were analyzed for E. coli, intestinal enterococci and somatic coliphages through cultivation and for human (BacH) and ruminant-specific (BacR) markers through qPCR assays. Expert judgments were collected regarding the probability of human and ruminant fecal contamination based on fecal indicator organism data and subjective information. Using Bayes formula, the conditional probability of a true human or ruminant fecal contamination given the presence of BacH or BacR was determined stochastically from expert judgments and regional qPCR assay performance, using Beta distributions to represent uncertainties. A web-based computational tool was developed for the procedure, which provides a measure of confidence to findings of host-specific markers and demonstrates the information value from these assays.
Collapse
Affiliation(s)
- Johan Åström
- Tyréns AB, Lilla Badhusgatan 2, SE-411 21 Gothenburg, Sweden
| | - Thomas J. R. Pettersson
- Water Environment Technology, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden
| | - Georg H. Reischer
- Interuniversity Center Water & Health, Institute of Chemical Engineering, Vienna University of Technology, Gumpendorfer Straße 1a/166-5-2, A-1060 Vienna, Austria
| | - Tommy Norberg
- Department of Mathematical Sciences, University of Gothenburg and Chalmers University of Technology, SE-412 96 Gothenburg, Sweden
| | - Malte Hermansson
- Department of Chemistry and Molecular Biology, Microbiology, University of Gothenburg, SE-405 30 Gothenburg, Sweden
- Corresponding Author Phone +46(0)31 786 2575; fax +46(0)31 786 2599; .
| |
Collapse
|