1
|
Orgil BO, Chintanaphol M, Alberson NR, Letourneau L, Martinez HR, Towbin JA, Purevjav E. Animal Models for Mechanical Circulatory Support: A Research Review. Rev Cardiovasc Med 2024; 25:351. [PMID: 39484122 PMCID: PMC11522838 DOI: 10.31083/j.rcm2510351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 04/25/2024] [Accepted: 06/19/2024] [Indexed: 11/03/2024] Open
Abstract
Heart failure is a clinical syndrome that has become a leading public health problem worldwide. Globally, nearly 64 million individuals are currently affected by heart failure, causing considerable medical, financial, and social challenges. One therapeutic option for patients with advanced heart failure is mechanical circulatory support (MCS) which is widely used for short-term or long-term management. MCS with various ventricular assist devices (VADs) has gained traction in end-stage heart failure treatment as a bridge-to-recovery, -decision, -transplant or -destination therapy. Due to limitations in studying VADs in humans, animal studies have substantially contributed to the development and advancement of MCS devices. Large animals have provided an avenue for developing and testing new VADs and improving surgical strategies for VAD implantation and for evaluating the effects and complications of MCS on hemodynamics and organ function. VAD modeling by utilizing rodents and small animals has been successfully implemented for investigating molecular mechanisms of cardiac unloading after the implantation of MCS. This review will cover the animal research that has resulted in significant advances in the development of MCS devices and the therapeutic care of advanced heart failure.
Collapse
Affiliation(s)
- Buyan-Ochir Orgil
- The Heart Institute, Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN 38103, USA
- Children’s Foundation Research Institute, Le Bonheur Children’s Hospital, Memphis, TN 38103, USA
| | - Michelle Chintanaphol
- College of Medicine, University of Tennessee Health Science Center, Memphis, TN 38103, USA
| | - Neely R. Alberson
- The Heart Institute, Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN 38103, USA
- Children’s Foundation Research Institute, Le Bonheur Children’s Hospital, Memphis, TN 38103, USA
| | | | - Hugo R. Martinez
- The Heart Institute, Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN 38103, USA
- Children’s Foundation Research Institute, Le Bonheur Children’s Hospital, Memphis, TN 38103, USA
| | - Jeffrey A. Towbin
- The Heart Institute, Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN 38103, USA
- Children’s Foundation Research Institute, Le Bonheur Children’s Hospital, Memphis, TN 38103, USA
- Pediatric Cardiology, St. Jude Children's Research Hospital, Memphis, TN 38105, USA
| | - Enkhsaikhan Purevjav
- The Heart Institute, Department of Pediatrics, University of Tennessee Health Science Center, Memphis, TN 38103, USA
- Children’s Foundation Research Institute, Le Bonheur Children’s Hospital, Memphis, TN 38103, USA
| |
Collapse
|
2
|
Hord EC, Hager MP, Bolch CM, Bonugli K, Guo LJ, Tuzun E, Criscione JC. Preclinical Proof-of-Concept of a Minimally Invasive Direct Cardiac Compression Device for Pediatric Heart Support. Cardiovasc Eng Technol 2024; 15:147-158. [PMID: 38110762 PMCID: PMC11116177 DOI: 10.1007/s13239-023-00703-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 11/21/2023] [Indexed: 12/20/2023]
Abstract
PURPOSE For pediatric patients, extracorporeal membrane oxygenation (ECMO) remains the predominant mechanical circulatory support (MCS) modality for heart failure (HF) although survival to discharge rates remain between 50 and 60% for these patients. The device-blood interface and disruption of physiologic hemodynamics are significant contributors to poor outcomes. METHODS In this study, we evaluate the preclinical feasibility of a minimally invasive, non-blood-contacting pediatric DCC prototype for temporary MCS. Proof-of-concept is demonstrated in vivo in an animal model of HF. Hemodynamic pressures and flows were examined. RESULTS Minimally invasive deployment on the beating heart was successful without cardiopulmonary bypass or anticoagulation. During HF, device operation resulted in an immediate 43% increase in cardiac output while maintaining pulsatile hemodynamics. Compared to the pre-HF baseline, the device recovered up to 95% of ventricular stroke volume. At the conclusion of the study, the device was easily removed from the beating heart. CONCLUSIONS This preclinical proof-of-concept study demonstrated the feasibility of a DCC device on a pediatric scale that is minimally invasive and non-blood contacting, with promising hemodynamic support and durability for the initial intended duration of use. The ability of DCC to maintain pulsatile MCS without blood contact represents an opportunity to mitigate the mortality and morbidity observed in non-pulsatile, blood-contacting MCS.
Collapse
Affiliation(s)
- Erica C Hord
- CorInnova, Inc. JLABS @ TMC, 2450 Holcombe Blvd Suite J, Houston, TX, 77021, USA
| | - Melanie P Hager
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building 3120 TAMU, College Station, TX, 77843-3120, USA
- Texas A&M University College of Medicine, 3050 Health Professions Education Building 1359 TAMU, Bryan, TX, 77807-1359, USA
| | - Christina M Bolch
- CorInnova, Inc. JLABS @ TMC, 2450 Holcombe Blvd Suite J, Houston, TX, 77021, USA
| | - Katherine Bonugli
- Texas A&M University Institute for Preclinical Studies, 4478 TAMU, College Station, TX, 77843-4478, USA
| | - Lee-Jae Guo
- Texas A&M University Institute for Preclinical Studies, 4478 TAMU, College Station, TX, 77843-4478, USA
| | - Egemen Tuzun
- Texas A&M University Institute for Preclinical Studies, 4478 TAMU, College Station, TX, 77843-4478, USA
| | - John C Criscione
- CorInnova, Inc. JLABS @ TMC, 2450 Holcombe Blvd Suite J, Houston, TX, 77021, USA.
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building 3120 TAMU, College Station, TX, 77843-3120, USA.
- Texas A&M University College of Medicine, 3050 Health Professions Education Building 1359 TAMU, Bryan, TX, 77807-1359, USA.
| |
Collapse
|
3
|
Kozik D, Alsoufi B. Pediatric mechanical circulatory support - a review. Indian J Thorac Cardiovasc Surg 2023; 39:80-90. [PMID: 37525715 PMCID: PMC10386992 DOI: 10.1007/s12055-023-01499-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 02/23/2023] [Accepted: 02/27/2023] [Indexed: 03/29/2023] Open
Abstract
The history of mechanical circulatory support began in 1953, as the first heart-lung machine enabled surgeons to perform complex open heart surgery. Heart failure is more prevalent in adults than pediatric patients which has led to the development of devices for adults with end-stage heart failure at a faster pace. Pediatric mechanical circulatory support has been derived from adult durable devices and subsequently applied in the adolescent population. The application of adult devices in children is inherently problematic due to size mismatch, especially in smaller patients. There has been an increasing interest in developing durable pumps that are appropriate for children for several reasons, with the primary factor being the number of children with end-stage heart failure far exceeding the number of potential donors. Mechanical circulatory support (MCS) for children can be divided into short-term temporary support and long-term durable support. The goal of this review is to discuss the devices available for the pediatric population and review the options for support in complex patients including single-ventricle anatomy, biventricular support, and total artificial heart options. We will also briefly discuss the Pumps for Kids, Infants, and Neonates (PumpKIN) Trial and MCS registries, including the Advanced Cardiac Therapies Improving Outcomes Network (ACTION).
Collapse
Affiliation(s)
- Deborah Kozik
- Department of Cardiovascular and Thoracic Surgery, Norton Children’s Hospital, University of Louisville School of Medicine, Louisville, KY USA
| | - Bahaaldin Alsoufi
- Department of Cardiovascular and Thoracic Surgery, Norton Children’s Hospital, University of Louisville School of Medicine, Louisville, KY USA
| |
Collapse
|
4
|
Fox CS, Palazzolo T, Hirschhorn M, Stevens RM, Rossano J, Day SW, Tchantchaleishvili V, Throckmorton AL. Development of the Centrifugal Blood Pump for a Hybrid Continuous Flow Pediatric Total Artificial Heart: Model, Make, Measure. Front Cardiovasc Med 2022; 9:886874. [PMID: 35990958 PMCID: PMC9386069 DOI: 10.3389/fcvm.2022.886874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 06/16/2022] [Indexed: 11/13/2022] Open
Abstract
Clinically-available blood pumps and total artificial hearts for pediatric patients continue to lag well behind those developed for adults. We are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). The hybrid TAH design integrates both an axial and centrifugal blood pump within a single, compact housing. The centrifugal pump rotates around the separate axial pump domain, and both impellers rotate around a common central axis. Here, we concentrate our development effort on the centrifugal blood pump by performing computational fluid dynamics (CFD) analysis of the blood flow through the pump. We also conducted transient CFD analyses (quasi-steady and transient rotational sliding interfaces) to assess the pump's dynamic performance conditions. Through modeling, we estimated the pressure generation, scalar stress levels, and fluid forces exerted on the magnetically levitated impellers. To further the development of the centrifugal pump, we also built magnetically-supported prototypes and tested these in an in vitro hydraulic flow loop and via 4-h blood bag hemolytic studies (n = 6) using bovine blood. The magnetically levitated centrifugal prototype delivered 0–6.75 L/min at 0–182 mmHg for 2,750–4,250 RPM. Computations predicted lower pressure-flow performance results than measured by testing; axial and radial fluid forces were found to be <3 N, and mechanical power usage was predicted to be <5 Watts. Blood damage indices (power law weighted exposure time and scalar stress) were <2%. All data trends followed expectations for the centrifugal pump design. Six peaks in the pressure rise were observed in the quasi-steady and transient simulations, correlating to the blade passage frequency of the 6-bladed impeller. The average N.I.H value (n = 6) was determined to be 0.09 ± 0.02 g/100 L, which is higher than desired and must be addressed through design improvement. These data serve as a strong foundation to build upon in the next development phase, whereby we will integrate the axial flow pump component.
Collapse
Affiliation(s)
- Carson S. Fox
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
| | - Thomas Palazzolo
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
| | - Matthew Hirschhorn
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
| | - Randy M. Stevens
- St. Christopher's Hospital for Children, Philadelphia, PA, United States
| | - Joseph Rossano
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Steven W. Day
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, NY, United States
| | | | - Amy L. Throckmorton
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
- *Correspondence: Amy L. Throckmorton
| |
Collapse
|
5
|
Bouhout I, Nguyen SN, Barry OM, Bacha EA, Goldstone AB. Transinnominate Impella 5.5 insertion as a bridge to transplantation in a pediatric patient in refractory cardiogenic shock. JTCVS Tech 2022; 14:201-203. [PMID: 35967222 PMCID: PMC9367200 DOI: 10.1016/j.xjtc.2022.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 06/13/2022] [Indexed: 10/25/2022] Open
Affiliation(s)
- Ismail Bouhout
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic, and Vascular Surgery, New York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Irving Medical Center, New York, NY
| | - Stephanie N Nguyen
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic, and Vascular Surgery, New York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Irving Medical Center, New York, NY
| | - Oliver M Barry
- Division of Pediatric Cardiology, New York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Irving Medical Center, New York, NY
| | - Emile A Bacha
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic, and Vascular Surgery, New York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Irving Medical Center, New York, NY
| | - Andrew B Goldstone
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic, and Vascular Surgery, New York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Irving Medical Center, New York, NY
| |
Collapse
|
6
|
Palazzolo T, Hirschhorn M, Garven E, Day S, Stevens RM, Rossano J, Tchantchaleishvili V, Throckmorton AL. Technology Landscape of Pediatric Mechanical Circulatory Support Devices- A Systematic Review 2010-2021. Artif Organs 2022; 46:1475-1490. [PMID: 35357020 PMCID: PMC9256769 DOI: 10.1111/aor.14242] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 02/17/2022] [Accepted: 03/15/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Mechanical circulatory support (MCS) devices, such as ventricular assist devices (VADs) and total artificial hearts (TAHs), have become a vital therapeutic option in the treatment of end-stage heart failure for adult patients. Such therapeutic options continue to be limited for pediatric patients. Clinicians initially adapted or scaled existing adult devices for pediatric patients; however, these adult devices are not designed to support the anatomical structure and varying flow capacities required for this population and are generally operated "off-design", which risks complications such as hemolysis and thrombosis. Devices designed specifically for the pediatric population that seek to address these shortcomings are now emerging and gaining FDA approval. METHODS To analyze the competitive landscape of pediatric MCS devices, we conducted a systematic literature review. Approximately 27 devices were studied in detail: 8 were established or previously approved designs, and 19 were under development (11 VADs, 5 Fontan assist devices, and 3 TAHs). RESULTS Despite significant progress, there is still no pediatric pump technology that satisfies the unique and distinct design constraints and requirements to support pediatric patients, including the wide range of patient sizes, increased cardiovascular demand with growth, and anatomic and physiologic heterogeneity of congenital heart disease. CONCLUSIONS Forward-thinking design solutions are required to overcome these challenges and to ensure the translation of new therapeutic MCS devices for pediatric patients.
Collapse
Affiliation(s)
- Thomas Palazzolo
- BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Matthew Hirschhorn
- BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Ellen Garven
- BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Steven Day
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, NY, USA
| | - Randy M Stevens
- College of Medicine, St. Christopher's Hospital for Children, Drexel University, Philadelphia, PA, USA
| | - Joseph Rossano
- Division of Pediatric Cardiology, The Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Vakhtang Tchantchaleishvili
- Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| | - Amy L Throckmorton
- BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA
| |
Collapse
|
7
|
A Mechanistic Lumped Parameter Model of the Berlin Heart EXCOR to Analyze Device Performance and Physiologic Interactions. Cardiovasc Eng Technol 2022; 13:603-623. [PMID: 34997556 DOI: 10.1007/s13239-021-00603-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 12/09/2021] [Indexed: 11/02/2022]
Abstract
PURPOSE The Berlin Heart EXCOR (BH) is the only FDA-approved, extracorporeal pulsatile ventricular assist device (VAD) for infants and children with heart failure. Clinicians control four settings on the device-systolic and diastolic drive pressures, device pump rate, and systolic time as a percentage of the pump cycle. However, interactions between BH pneumatics and the native circulation remain poorly understood. Thus, establishing appropriate device size and settings can be challenging on a patient-to-patient basis. METHODS In this study we develop a novel lumped parameter network based on simplified device mechanics. We perform parametric studies to characterize device behavior, study interactions between the left ventricle (LV) and BH across different device settings, and develop patient-specific simulations. We then simulate the impact of changing device parameters for each of three patients. RESULTS Increasing systolic pressure and systolic time increased device output. We identified previously unobserved cycle-to-cycle variations in LV-BH interactions that may impact patient health. Patient-specific simulations demonstrated the model's ability to replicate BH performance, captured trends in LV behavior after device implantation, and emphasized the importance of device rate and volume in optimizing BH efficiency. CONCLUSION We present a novel, mechanistic model that can be readily adjusted to study a wide range of device settings and clinical scenarios. Physiologic interactions between the BH and the native LV produced large variability in cardiac loading. Our findings showed that operating the BH at a device rate greater than the patient's native heart decreases variability in physiological interactions between the BH and LV, increasing cardiac offloading while maintaining cardiac output. Device rates that are close to the resting heart rate may result in unfavorable cardiac loading conditions. Our work demonstrates the utility of our model to investigate BH performance for patient-specific physiologies.
Collapse
|
8
|
Hugenroth K, Neidlin M, Engelmann UM, Kaufmann TAS, Steinseifer U, Heilmann T. Tipless transseptal cannula concept combines improved hemodynamic properties and risk-reduced placement: An in silico proof-of-concept. Artif Organs 2021; 45:1024-1035. [PMID: 33851427 DOI: 10.1111/aor.13964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 03/17/2021] [Accepted: 04/06/2021] [Indexed: 11/30/2022]
Abstract
As a leading cause of death worldwide, heart failure is a serious medical condition in which many critically ill patients require temporary mechanical circulatory support (MCS) as a bridge-to-recovery or bridge-to-decision. In many cases, the TandemHeart system is used to unload the left heart by draining blood from the left atrium (LA) to the femoral artery via a transseptal multistage cannula. However, even though the correct positioning of the cannula is crucial for a safe treatment, the long cannula tip currently used in transseptal cannulas complicates positioning, making the cannula vulnerable to displacement during MCS. To overcome these limitations, we propose the development of a new tipless transseptal cannula with improved hemodynamic properties. We discuss the tipless cannula concept by comparing it to the common multistage cannula concept using computational fluid dynamics simulations and assess the flow field in the LA, the wall shear stresses (WSS), and the pressure loss. Across the two distinct time points of end-systole and end-diastole and two drainage flow rates of 3.5 and 5.0 L/min, we find a more homogeneous inlet flow pattern for the tipless cannula concept, accompanied by a remarkably reduced area of platelet-activating WSS (up to 10-times smaller area compared to the multistage cannula). Moreover, pressure loss is up to 14.5% lower in the tipless cannula concept, confirming overall improved hemodynamic properties of the tipless cannula concept. Finally, a diameter-dependent study reveals that lower WSS and pressure losses can be further reduced by large-lumen designs for any simulation setting. Overall, our results suggest that a tipless cannula concept remedies the crucial disadvantages of a long-tip multistage cannula by reducing the risk of misplacement, and it furthermore promotes optimized hemodynamics. With this successful proof-of-concept, we underscore the potential for and encourage the realization of further experimental investigations regarding the development of a tipless transseptal cannula for MCS.
Collapse
Affiliation(s)
- Kristin Hugenroth
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany.,enmodes GmbH, Aachen, Germany
| | - Michael Neidlin
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany
| | - Ulrich M Engelmann
- enmodes GmbH, Aachen, Germany.,Department of Medical Engineering and Applied Mathematics, FH Aachen University of Applied Sciences, Aachen, Germany
| | - Tim A S Kaufmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany.,enmodes GmbH, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany
| | | |
Collapse
|
9
|
McPherson I, Generali T, Reinhardt Z, Chilvers N, Nassar M, De Rita F, Viganò G, Schueler S, Hasan A. HeartWare Explant After Recovery 6 Years After Implant in a 3-Year-Old Child: Has the Game Changed? Ann Thorac Surg 2021; 112:e37-e39. [PMID: 33412138 DOI: 10.1016/j.athoracsur.2020.10.061] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 10/08/2020] [Accepted: 10/12/2020] [Indexed: 11/30/2022]
Abstract
The use of continuous-flow mechanical circulatory support in preschool children remains anecdotal. This case report describes the sequel to the implantation with a HeartWare HVAD system (Medtronic, Minneapolis, MN) in a 3-year old child. A 3-year-old boy with myocarditis-related cardiomyopathy underwent implantation with a HeartWare device. After an uncomplicated postoperative course, the patient was discharged home. Serial echocardiography showed progressive left ventricular recovery. After 6 months, the device was decommissioned, and the outflow graft was tied off. Six years after insertion, the device was explanted uneventfully. The HeartWare ventricular assist device offers viable long-term mechanical circulatory support in selected children that results in sustainable care and good quality of life.
Collapse
Affiliation(s)
- Iain McPherson
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Tommaso Generali
- Department of Congenital Cardiac Surgery and Cardiopulmonary Transplantation, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom.
| | - Zdenka Reinhardt
- Department of Pediatric Cardiology and Transplantation, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Nicholas Chilvers
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Mohamed Nassar
- Department of Congenital Cardiac Surgery and Cardiopulmonary Transplantation, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Fabrizio De Rita
- Department of Congenital Cardiac Surgery and Cardiopulmonary Transplantation, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Gaia Viganò
- Department of Congenital Cardiac Surgery and Cardiopulmonary Transplantation, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Stephan Schueler
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| | - Asif Hasan
- Department of Congenital Cardiac Surgery and Cardiopulmonary Transplantation, Freeman Hospital, Newcastle-upon-Tyne, United Kingdom
| |
Collapse
|
10
|
Thangappan K, Morales DLS, Vu Q, Lehenbauer D, Villa C, Wittekind S, Hirsch R, Lorts A, Zafar F. Impact of mechanical circulatory support on pediatric heart transplant candidates with elevated pulmonary vascular resistance. Artif Organs 2020; 45:29-37. [PMID: 32530089 DOI: 10.1111/aor.13747] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 06/28/2020] [Accepted: 05/30/2020] [Indexed: 12/31/2022]
Abstract
With the new era of increasing use of mechanical circulatory support (MCS) in children, seemingly more patients with elevated pulmonary vascular resistance (PVR) are having positive outcomes. The purpose of this study was to define the effect of MCS on pediatric patients listed for heart transplant with an elevated PVR. The United Network for Organ Sharing (UNOS) database was used to identify patients aged 0-18 at the time of listing for heart transplant between 2010 and 2019 who had PVR documented (n = 2081). Patients were divided into MCS (LVAD, RVAD, BiVAD, and TAH) and No MCS groups, then divided by PVR (PVR) at the time of listing: <3, 3-6, and >6 Wood units (WU). MCS was used in 20% overall (n = 426); 57% of those with PVR <3, 27% with PVR 3-6, and 16% with PVR >6. MCS, PVR <3 patients had a higher chance of positive waitlist outcome than all No MCS groups (vs. PVR <3, P = .049; vs. PVR 3-6, P = .004; vs. PVR >6, P < .001). MCS, PVR 3-6 patients had a higher chance of positive waitlist outcome than all No MCS groups (vs. PVR <3, P = .048; vs. PVR 3-6, P = .009; vs. PVR >6, P < .001). MCS, PVR >6 patients had a higher chance of positive waitlist outcome than No MCS, PVR >6 patients (P = .012). Within the No MCS group, patients with a PVR >6 had a higher incidence of negative waitlist outcome compared to PVR <3 (17% vs. 10%, P = .002); this was not the case in the MCS group (5% vs. 6%, P = .693). More patients in the MCS group were ventilator dependent (15% vs. 9%, P < .001) at the time of listing and less likely to have a functional status >50% (43% vs. 73%, P < .001). No significant differences in post-transplant survival were found in pairwise comparisons of MCS and No MCS PVR subgroups. Patients supported with MCS had a significantly higher chance of a positive waitlist outcome than those without such support regardless of PVR status. This was most pronounced with a PVR greater than 6 WU. MCS compared to No MCS patients had better waitlist survival and equivalent post-transplant survival. MCS patients, despite being more ill, had better overall survival regardless of PVR.
Collapse
Affiliation(s)
- Karthik Thangappan
- Department of Cardiothoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - David L S Morales
- Department of Cardiothoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Quyen Vu
- Department of Cardiothoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - David Lehenbauer
- Department of Cardiothoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Chet Villa
- Department of Cardiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Samuel Wittekind
- Department of Cardiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Russel Hirsch
- Department of Cardiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Angela Lorts
- Department of Cardiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Farhan Zafar
- Department of Cardiothoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| |
Collapse
|
11
|
Di Candia A, Castaldi B, Bordin G, Cerutti A, Reffo E, Biffanti R, Di Salvo G, Vida VL, Padalino MA. Pulmonary Artery Banding for Ventricular Rehabilitation in Infants With Dilated Cardiomyopathy: Early Results in a Single-Center Experience. Front Pediatr 2020; 8:347. [PMID: 32766180 PMCID: PMC7381108 DOI: 10.3389/fped.2020.00347] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 05/26/2020] [Indexed: 12/28/2022] Open
Abstract
Background: Pulmonary artery banding (PAB) is reported as an innovative strategy for children with end-stage heart failure (ESHF) to bridge to transplantation or recovery. We report our early experience with PAB to evaluate outcomes, indications, and limitations. Materials and Methods: This is a single-center prospective clinical study, including infants and children admitted for ESHF owing to dilated cardiomyopathy (DCM) with preserved right ventricular function after failure of maximal conventional therapy. All patients underwent perioperative anticongestive medical therapy with ACE inhibitor, beta blocker, and spironolactone. Post-operatively, all patients underwent echocardiographic follow-up to assess myocardial recovery. Results: We selected five patients (four males) who underwent PAB at a median age of 8.6 months (range 3.9-42.2 months), with preoperative ejection fraction (EF) <30%. Sternal closure was delayed in all. One patient did not improve after PAB and underwent Berlin Heart implantation after 33 days, followed by heart transplant after 13 months. Four patients were discharged home on full anticongestive therapy. However, 2 months after discharge, one patient experienced severe acute heart failure secondary to pneumonia, which required mechanical circulatory support, and the patient underwent a successful heart transplant after 21 days. The remaining three patients are doing well at home, 22.4, 16.9, and 15.4 months after PAB. They all underwent elective percutaneous de-banding, 18.5, 4.8, and 10.7 months after PAB. EF increased from 17.7 ± 8.5% to 63.3 ± 7.6% (p = 0.03), and they have all been delisted. Conclusion: Use of PAB may be an effective alternative to mechanical support in selected infants for bridging to transplant or recovery. Better results seem to occur in patients aged <12 months. Further experience and research are required to identify responders and non-responders to this approach.
Collapse
Affiliation(s)
- Angela Di Candia
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Biagio Castaldi
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Giulia Bordin
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Alessia Cerutti
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Elena Reffo
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Roberta Biffanti
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Giovanni Di Salvo
- Pediatric Cardiology Unit, Department of Woman and Child's Health, University of Padua, Padua, Italy
| | - Vladimiro L Vida
- Pediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic and Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Massimo A Padalino
- Pediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic and Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|