1
|
Insufficient evidence to confirm benefits of custom partial knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc 2022; 30:3968-3982. [PMID: 34792611 DOI: 10.1007/s00167-021-06766-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Accepted: 10/02/2021] [Indexed: 12/25/2022]
Abstract
PURPOSE The purpose of this systematic review was to synthesise the available literature and critically appraise current evidence on the functional and radiographic outcomes as well as reoperation and revision rates of custom partial knee arthroplasty, i.e., unicompartmental knee arthroplasty (UKA), bicompartmental knee arthroplasty (BKA), and patellofemoral arthroplasty (PFA). MATERIAL AND METHODS This systematic review was performed in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), and a protocol was registered with Prospero. On 25 May 2021, two authors independently searched and screened Level I-IV studies that reported on outcomes of custom partial knee arthroplasty using the databases of MEDLINE®, EMBASE®, and the Cochrane Library without restriction on date of publication. Findings from eligible articles were synthesised and tabulated, and quality assessments were done according to the guidelines of the Joanna Briggs Institute (JBI) Checklists. RESULTS Fifteen articles were eligible for data extraction, of which two comparative and four case series were on custom UKA (follow-up, 0-9 months), one comparative and five case series on custom BKA (follow-up, 0.25-72 months), and three case series on custom PFA (follow-up, 2-119 months). Three studies on custom UKA reported mean Knee Society Score (KSS) Knee of 86-94 and mean KSS Function of 94-95, and two studies on custom BKA reported mean KSS Knee of 90-94 and KSS function of 81, whereas one study on custom PFA reported KSS Knee of 91 and KSS Function of 89. Custom implants tended to have less bone-implant mismatch compared to off the shelf (OTS) implants. Revision rates were 3-25% for custom UKA (at 0-109 months), 3-5% for custom BKA (at 12-72 months), and 0-14% for custom PFA (at 2-119 months). CONCLUSION Due to the small number of comparative studies and lack of consistency in reported outcomes, it remains difficult to ascertain the benefits of custom partial knee arthroplasty. Anecdotal evidence suggests that, compared to OTS implants, custom implants result in less bone-implant mismatch and that 78-91% of patients are either satisfied or very satisfied after custom partial knee arthroplasty. LEVEL OF EVIDENCE IV.
Collapse
|
2
|
Koh YG, Lee JA, Chung HS, Kim HJ, Kang KT. Restoration of normal knee kinematics with respect to tibial insert design in mobile bearing lateral unicompartmental arthroplasty using computational simulation. Bone Joint Res 2020; 9:421-428. [PMID: 32864113 PMCID: PMC7437519 DOI: 10.1302/2046-3758.97.bjr-2019-0384.r1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Aims Mobile-bearing unicompartmental knee arthroplasty (UKA) with a flat tibial plateau has not performed well in the lateral compartment, leading to a high rate of dislocation. For this reason, the Domed Lateral UKA with a biconcave bearing was developed. However, medial and lateral tibial plateaus have asymmetric anatomical geometries, with a slightly dished medial and a convex lateral plateau. Therefore, the aim of this study was to evaluate the extent at which the normal knee kinematics were restored with different tibial insert designs using computational simulation. Methods We developed three different tibial inserts having flat, conforming, and anatomy-mimetic superior surfaces, whereas the inferior surface in all was designed to be concave to prevent dislocation. Kinematics from four male subjects and one female subject were compared under deep knee bend activity. Results The conforming design showed significantly different kinematics in femoral rollback and internal rotation compared to that of the intact knee. The flat design showed significantly different kinematics in femoral rotation during high flexion. The anatomy-mimetic design preserved normal knee kinematics in femoral rollback and internal rotation. Conclusion The anatomy-mimetic design in lateral mobile UKA demonstrated restoration of normal knee kinematics. Such design may allow achievement of the long sought normal knee characteristics post-lateral mobile UKA. However, further in vivo and clinical studies are required to determine whether this design can truly achieve a more normal feeling of the knee and improved patient satisfaction. Cite this article: Bone Joint Res 2020;9(7):421–428.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| | - Hyun-Seok Chung
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Hyo-Jeong Kim
- Department of Sport and Healthy Aging, Korea National Sport University, Seoul, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
3
|
Roth KE, Betz S, Schmidtmann I, Maier GS, Ludwig HR, Vogl T, Theisen A, Brochhausen C, Götz H, Drees P, Rompe JD, Kurth AA. Biological responses to individualized small titanium implants for the treatment of focal full-thickness knee cartilage defects in a sheep model. Knee 2020; 27:1078-1092. [PMID: 32307219 DOI: 10.1016/j.knee.2020.03.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 12/21/2019] [Accepted: 03/27/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND The present study aimed to evaluate the functional, radiological and histological outcome of a customized focal implant for the treatment of focal full-thickness cartilage defects in sheep. METHODS The study used magnetic resonance imaging data as the basis for construction of the titanium implant using a three-dimensional printing technique. This was then placed on the medial condyle of the knee joint in eight sheep and left in place in vivo over a period of six months. Following euthanasia, the local biological response was analyzed using micro-computed tomography, light microscopy and histological evaluation (International Cartilage Repair Society (ICRS) score). The variables were analyzed using a generalized linear mixed model. Odds ratios were given with 95% confidence intervals. RESULTS The osseointegration rate was 62.1% (SD 3.9%). All implants were prone to the neighboring cartilage bed (4.4-1096.1 μm). Using the IRCS score, the elements 'surface', 'matrix', 'cell distribution' and 'cell population' all showed pathological changes on the operated side, although these did not correlate with implant elevation. On average, a difference of 0.7 mm (±2 mm) was found between the digitally planned implant and the real implant. CONCLUSIONS As a result of imprecise segmentation and difficult preparation conditions at the prosthesis bed, as well as changes at the surface of the implant over the operational lifetime of the prosthesis, it must be stated that the approach implemented here of using a customized implant for the treatment of focal full-thickness cartilage defects at the knee did not meet our expectations.
Collapse
Affiliation(s)
- Klaus Edgar Roth
- Centre of Orthopedic and Trauma Surgery, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany.
| | - Simon Betz
- University of Applied Sciences, Computer Science and Engineering, Frankfurt, Germany
| | - Irene Schmidtmann
- Institute for Medical Biometry, Epidemiology and Computer Science, Johannes Gutenberg University, Mainz, Germany
| | - Gerrit Steffen Maier
- Centre of Orthopedic and Trauma Surgery, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany
| | - Hans-Reiner Ludwig
- University of Applied Sciences, Computer Science and Engineering, Frankfurt, Germany
| | - Thomas Vogl
- Institute for diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Alf Theisen
- Ernst Struengmann Institute (ESI) for Neuroscience, Frankfurt, Germany
| | - Christoph Brochhausen
- Institute for Pathology, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany
| | - Hermann Götz
- Platform for Biomaterial Research, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany
| | - Philipp Drees
- Centre of Orthopedic and Trauma Surgery, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany
| | | | - Andreas Alois Kurth
- Centre of Orthopedic and Trauma Surgery, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany
| |
Collapse
|
4
|
Lee JA, Koh YG, Kang KT. Biomechanical and Clinical Effect of Patient-Specific or Customized Knee Implants: A Review. J Clin Med 2020; 9:jcm9051559. [PMID: 32455733 PMCID: PMC7290390 DOI: 10.3390/jcm9051559] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 05/13/2020] [Accepted: 05/15/2020] [Indexed: 01/22/2023] Open
Abstract
(1) Background: Although knee arthroplasty or knee replacement is already an effective clinical treatment, it continues to undergo clinical and biomechanical improvements. For an increasing number of conditions, prosthesis based on an individual patient's anatomy is a promising treatment. The aims of this review were to evaluate the clinical and biomechanical efficacy of patient-specific knee prosthesis, explore its future direction, and summarize any published comparative studies. (2) Methods: We searched the PubMed, MEDLINE, Embase, and Scopus databases for articles published prior to February 1, 2020, with the keywords "customized knee prosthesis" and "patient-specific knee prosthesis". We excluded patient-specific instrument techniques. (3) Results: Fifty-seven articles met the inclusion criteria. In general, clinical improvement was greater with a patient-specific knee prosthesis than with a conventional knee prosthesis. In addition, patient-specific prosthesis showed improved biomechanical effect than conventional prosthesis. However, in one study, patient-specific unicompartmental knee arthroplasty showed a relatively high rate of aseptic loosening, particularly femoral component loosening, in the short- to medium-term follow-up. (4) Conclusions: A patient-specific prosthesis provides a more accurate resection and fit of components, yields significant postoperative improvements, and exhibits a high level of patient satisfaction over the short to medium term compared with a conventional prosthesis. However, the tibial insert design of the current patient-specific knee prosthesis does not follow the tibial plateau curvature.
Collapse
Affiliation(s)
- Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea;
| | - Yong-Gon Koh
- Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, Korea;
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea;
- Correspondence: ; Tel.: +82-2-588-1006
| |
Collapse
|
5
|
Koh YG, Lee JA, Lee HY, Chun HJ, Kim HJ, Kang KT. Anatomy-mimetic design preserves natural kinematics of knee joint in patient-specific mobile-bearing unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:1465-1472. [PMID: 31123794 DOI: 10.1007/s00167-019-05540-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 05/13/2019] [Indexed: 11/26/2022]
Abstract
PURPOSE This study aims to evaluate whether different tibial-femoral conformities for patient-specific mobile-bearing unicompartmental knee arthroplasties (UKAs) preserve natural knee kinematics, using computational simulations. METHODS Different designs for patient-specific mobile-bearing UKAs were evaluated using finite element analysis. Three designs for the identical femoral component were considered: flat (non-conforming design), anatomy-mimetic, and conforming for the tibial insert. RESULTS The conforming design for the patient-specific mobile-bearing UKAs exhibited a 1.2 mm and 0.7° decrease in the translation and rotation, respectively, in the swing phase compared with those of the natural knee. In addition, the femoral rollback and internal rotation were 2.6 mm and 1.2° lower, respectively, than those of the natural knee, for the conforming design under the deep-knee-bend condition. The flat design for the patient-specific mobile-bearing UKAs exhibited a 2.2 mm and 1.4° increase in the femoral rollback and rotation compared with the natural knee under the deep-knee-bend condition. The anatomy-mimetic patient-specific mobile-bearing UKAs best preserved the natural knee kinematics under the gait and deep-knee-bend loading conditions. CONCLUSIONS The kinematics of the loading conditions in patient-specific mobile-bearing UKAs was determined to closely resemble those of a native knee. In additional, by replacing the anatomy-mimetic design with a mobile-bearing, natural knee kinematics during gait and deep-knee-bend motions is preserved. These results confirm the importance of tibiofemoral conformity in preserving native knee kinematics in patient-specific mobile-bearing UKA.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Department of Orthopaedic Surgery, Joint Reconstruction Center, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, South Korea
| | - Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - Hwa-Yong Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - Heoung-Jae Chun
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - Hyo-Jeong Kim
- Department of Sport and Healthy Aging, Korea National Sport University, 1239 Yangjae-dearo, Songpa-gu, Seoul, 05541, South Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea.
| |
Collapse
|
6
|
Finite Element Study on the Preservation of Normal Knee Kinematics with Respect to the Prosthetic Design in Patient-Specific Medial Unicompartmental Knee Arthroplasty. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1829385. [PMID: 32258105 PMCID: PMC7109557 DOI: 10.1155/2020/1829385] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 01/07/2020] [Accepted: 02/13/2020] [Indexed: 11/17/2022]
Abstract
Alterations in native knee kinematics in medial unicompartmental knee arthroplasty (UKA) are caused by the nonanatomic articular surface of conventional implants. Technology for an anatomy mimetic patient-specific (PS) UKA has been introduced. However, there have been no studies on evaluating the preservation of native knee kinematics with respect to different prosthetic designs in PS UKA. The purpose of this study was to evaluate the preservation of native knee kinematics with respect to different UKA designs using a computational simulation. We evaluated three different UKA designs: a nonconforming design, an anatomy mimetic design, and a conforming design for use under gait and squat loading conditions. The results show that the anatomy mimetic UKA design achieves closer kinematics to those of a native knee compared to the other two UKA designs under such conditions. The anatomy memetic UKA design exhibited a 0.39 mm and 0.36° decrease in the translation and rotation, respectively, in the swing phase compared with those of the natural knee. In addition, under the gait and squat loading conditions, the conforming UKA design shows limited kinematics compared to the nonconforming UKA design. Our results show that the conformity of each component in PS UKA is an important factor in knee joint kinematics; however, the anatomy mimetic UKA design cannot restore perfect native kinematics.
Collapse
|
7
|
Koh YG, Park KM, Lee HY, Park JH, Kang KT. Prediction of wear performance in femoral and tibial conformity in patient-specific cruciate-retaining total knee arthroplasty. J Orthop Surg Res 2020; 15:24. [PMID: 31969195 PMCID: PMC6977248 DOI: 10.1186/s13018-020-1548-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 01/06/2020] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Articular surface curvature design is important in tibiofemoral kinematics and the contact mechanics of total knee arthroplasty (TKA). Thus far, the effects of articular surface curvature have not been adequately discussed with respect to conforming, nonconforming, and medial pivot designs in patient-specific TKA. Therefore, this study evaluates the underlying relationship between the articular surface curvature geometry and the wear performance in patient-specific TKA. METHODS We compare the wear performances between conventional and patient-specific TKA under gait loading conditions using a computational simulation. Patient-specific TKAs investigated in the study are categorized into patient-specific TKA with conforming articular surfaces, medial pivot patient-specific TKA, and bio-mimetic patient-specific TKA with a patient's own tibial and femoral anatomy. The geometries of the femoral components in patient-specific TKAs are identical. RESULTS The anterior-posterior and internal-external kinematics change with respect to different TKA designs. Moreover, the contact pressure and area did not directly affect the wear performance. In particular, conforming patient-specific TKAs exhibit the highest volumetric wear and wear rate. The volumetric wear in a conforming patient-specific TKA is 29% greater than that in a medial pivot patient-specific TKA. CONCLUSION The findings in this study highlight that conformity changes in the femoral and tibial inserts influence the wear performance in patient-specific TKA. Kinematics and contact parameters should be considered to improve wear performance in patient-specific TKA. The conformity modification in the tibiofemoral joint changes the kinematics and contact parameters, and this affects wear performance.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Kyoung-Mi Park
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Hwa-Yong Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Joon-Hee Park
- Department of Anesthesiology & Pain Medicine, Hallym University College of Medicine and Kangdong Sacred Heart Hospital, 150 Seongan-ro, Gangdong-gu, Seoul, 05355, Republic of Korea.
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
8
|
Influence of Preservation of Normal Knee Contact Stress on Other Compartments with respect to the Tibial Insert Design for Unicompartmental Knee Arthroplasty. Appl Bionics Biomech 2019; 2019:9246379. [PMID: 31827605 PMCID: PMC6885156 DOI: 10.1155/2019/9246379] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 08/02/2019] [Accepted: 10/11/2019] [Indexed: 12/05/2022] Open
Abstract
Recent advances in imaging technology and additive manufacturing have led to the introduction of customized unicompartmental knee arthroplasty (UKA) that can potentially improve functional performance due to customized geometries, including customized sagittal and coronal curvature and enhanced bone preservation. The purpose of this study involved evaluating the biomechanical effect of the tibial insert design on the customized medial UKA using computer simulations. We developed sagittal and coronal curvatures in a native knee mimetic femoral component design. We utilized three types of tibial insert design: flat, anatomy mimetic, and conforming design. We evaluated contact stress on the tibial insert and other compartments, including the lateral meniscus and articular cartilage, under gait and squat loading conditions. For the conforming UKA design, the tibial insert and lateral meniscus exhibited the lowest contact stress under stance phase gait cycle. However, for the conforming UKA design, the tibial insert and lateral meniscus exhibited the highest contact stress under swing phase gait cycle. For the flat UKA design, the articular cartilage exhibited the lowest contact stress under gait and squat loading conditions. The anatomy mimetic UKA design exhibited the most normal-like contact stress on the other compartments under gait and squat loading conditions. The results reveal the importance of conformity between the femoral component and the tibial insert in the customized UKA. Based on the results on the femoral component as well as the tibial insert in the customized UKA, the anatomy mimetic design preserves normal knee joint biomechanics and thus may prevent progressive osteoarthritis of the other knee compartments.
Collapse
|
9
|
Koh YG, Lee JA, Lee HY, Kim HJ, Chung HS, Kang KT. Reduction in tibiofemoral conformity in lateral unicompartmental knee arthroplasty is more representative of normal knee kinematics. Bone Joint Res 2019; 8:593-600. [PMID: 31934330 PMCID: PMC6946914 DOI: 10.1302/2046-3758.812.bjr-2019-0114.r1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
AIMS Commonly performed unicompartmental knee arthroplasty (UKA) is not designed for the lateral compartment. Additionally, the anatomical medial and lateral tibial plateaus have asymmetrical geometries, with a slightly dished medial plateau and a convex lateral plateau. Therefore, this study aims to investigate the native knee kinematics with respect to the tibial insert design corresponding to the lateral femoral component. METHODS Subject-specific finite element models were developed with tibiofemoral (TF) and patellofemoral joints for one female and four male subjects. Three different TF conformity designs were applied. Flat, convex, and conforming tibial insert designs were applied to the identical femoral component. A deep knee bend was considered as the loading condition, and the kinematic preservation in the native knee was investigated. RESULTS The convex design, the femoral rollback, and internal rotation were similar to those of the native knee. However, the conforming design showed a significantly decreased femoral rollback and internal rotation compared with that of the native knee (p < 0.05). The flat design showed a significant difference in the femoral rollback; however, there was no difference in the tibial internal rotation compared with that of the native knee. CONCLUSION The geometry of the surface of the lateral tibial plateau determined the ability to restore the rotational kinematics of the native knee. Surgeons and implant designers should consider the geometry of the anatomical lateral tibial plateau as an important factor in the restoration of native knee kinematics after lateral UKA.Cite this article: Bone Joint Res 2019;8:593-600.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, South Korea
| | - Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, Seoul, South Korea
| | - Hwa-Yong Lee
- Department of Mechanical Engineering, Yonsei University, Seoul, South Korea
| | - Hyo-Jeong Kim
- Department of Sport and Healthy Aging, Korea National Sport University, Seoul, South Korea
| | - Hyun-Seok Chung
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, South Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, Seoul, South Korea
| |
Collapse
|
10
|
Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance. J Clin Med 2019; 8:jcm8112023. [PMID: 31752389 PMCID: PMC6912647 DOI: 10.3390/jcm8112023] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 11/14/2019] [Accepted: 11/18/2019] [Indexed: 11/17/2022] Open
Abstract
Life expectancy is on the rise and, concurrently, the demand for total knee arthroplasty (TKA), which lasts a lifetime, is increasing. To meet this demand, improved TKA designs have been introduced. Recent advances in radiography and manufacturing techniques have enabled the production of patient-specific TKA. Nevertheless, concerns regarding the wear performance, which limit the lifespan of TKA, remain to be addressed. This study aims at reducing the wear in patient-specific TKA using design optimization and parametric three-dimensional (3D) finite-element (FE) modelling. The femoral component design was implemented in a patient-specific manner, whereas the tibial insert conformity remained to be determined by design variables. The gait cycle loading condition was applied, and the optimized model was validated by the results obtained from the experimental wear tests. The wear predictions were iterated for five million gait cycles using the computational model with force-controlled input. Similar patterns for internal/external rotation and anterior/posterior translation were observed in both initial and optimal models. The wear rates for initial and optimal models were recorded as 23.2 mm3/million cycles and 16.7 mm3/million cycles, respectively. Moreover, the experimental wear rate in the optimal design was 17.8 mm3/million cycles, which validated our optimization procedure. This study suggests that tibial insert conformity is an important factor in influencing the wear performance of patient-specific TKA, and it is capable of providing improved clinical results through enhanced design selections. This finding can boost the future development of patient-specific TKA, and it can be extended to other joint-replacement designs. However, further research is required to explore the potential clinical benefits of the improved wear performance demonstrated in this study.
Collapse
|
11
|
Koh YG, Park KM, Kang KT. The biomechanical effect of tibiofemoral conformity design for patient-specific cruciate retainging total knee arthroplasty using computational simulation. J Exp Orthop 2019; 6:23. [PMID: 31161463 PMCID: PMC6546798 DOI: 10.1186/s40634-019-0192-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Accepted: 05/23/2019] [Indexed: 11/28/2022] Open
Abstract
Background Alterations to normal knee kinematics performed during conventional total knee arthroplasty (TKA) focus on the nonanatomic articular surface. Patient-specific TKA was introduced to provide better normal knee kinematics than conventional TKA. However, no study on tibiofemoral conformity has been performed after patient-specific TKA. The purpose of this study was to compare the biomechanical effect of cruciate-retaining (CR) implants after patient-specific TKA and conventional TKA under gait and deep-knee-bend conditions. Methods The examples of patient-specific TKA were categorized into conforming patient-specific TKA, medial pivot patient-specific TKA and anatomy mimetic articular surface patient-specific TKA. We investigated kinematics and quadriceps force of three patient-specific TKA and conventional TKA using validated computational model. The femoral component designs in patient specific TKA were all identical. Results The anatomy mimetic articular surface patient-specific TKA provided knee kinematics that was closer to normal than the others under the gait and deep-knee-bend conditions. However, the other two patient-specific TKA designs could not preserve the normal knee kinematics. In addition, the closest normal quadriceps force was found for the anatomic articular surface patient-specific TKA. Conclusions Our results showed that the anatomy mimetic articular surface patient-specific TKA provided close-to-normal knee mechanics. Other clinical and biomechanical studies are required to determine whether anatomy mimetic articular surface patient-specific TKA restores more normal knee mechanics and provides improved patient satisfaction.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Kyoung-Mi Park
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
12
|
Koh YG, Park KM, Lee HY, Kang KT. Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis. Bone Joint Res 2019; 8:156-164. [PMID: 30997041 PMCID: PMC6444019 DOI: 10.1302/2046-3758.83.bjr-2018-0193.r1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Objectives Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty for patients who require treatment of single-compartment osteoarthritis, especially for young patients. To satisfy this requirement, new patient-specific prosthetic designs have been introduced. The patient-specific UKA is designed on the basis of data from preoperative medical images. In general, knee implant design with increased conformity has been developed to provide lower contact stress and reduced wear on the tibial insert compared with flat knee designs. The different tibiofemoral conformity may provide designers the opportunity to address both wear and kinematic design goals simultaneously. The aim of this study was to evaluate wear prediction with respect to tibiofemoral conformity design in patient-specific UKA under gait loading conditions by using a previously validated computational wear method. Methods Three designs with different conformities were developed with the same femoral component: a flat design normally used in fixed-bearing UKA, a tibia plateau anatomy mimetic (AM) design, and an increased conforming design. We investigated the kinematics, contact stress, contact area, wear rate, and volumetric wear of the three different tibial insert designs. Results Conforming increased design showed a lower contact stress and increased contact area. In addition, increased conformity resulted in a reduction of the wear rate and volumetric wear. However, the increased conformity design showed limited kinematics. Conclusion Our results indicated that increased conformity provided improvements in wear but resulted in limited kinematics. Therefore, increased conformity should be avoided in fixed-bearing patient-specific UKA design. We recommend a flat or plateau AM tibial insert design in patient-specific UKA. Cite this article: Y-G. Koh, K-M. Park, H-Y. Lee, K-T. Kang. Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis. Bone Joint Res 2019;8:156–164. DOI: 10.1302/2046-3758.83.BJR-2018-0193.R1.
Collapse
Affiliation(s)
- Y-G Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, South Korea
| | - K-M Park
- Department of Mechanical Engineering, Department of Mechanical Engineering, Yonsei University, Seoul, South Korea
| | - H-Y Lee
- Department of Mechanical Engineering, Department of Mechanical Engineering, Yonsei University, Seoul, South Korea
| | - K-T Kang
- Department of Mechanical Engineering, Department of Mechanical Engineering, Yonsei University, Seoul, South Korea
| |
Collapse
|
13
|
Koh YG, Son J, Kwon OR, Kwon SK, Kang KT. Tibiofemoral conformity variation offers changed kinematics and wear performance of customized posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2019; 27:1213-1223. [PMID: 29974167 DOI: 10.1007/s00167-018-5045-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 06/27/2018] [Indexed: 01/17/2023]
Abstract
PURPOSE Posterior-stabilized (PS)-total knee arthroplasty (TKA) can be applied in any of several variations in terms of the tibiofemoral conformity and post-cam mechanism. However, previous studies have not evaluated the effect of the condylar surface radii (tibiofemoral conformity) on wear in a customized PS-TKA. The present study involved evaluating the wear performance with respect to three different conformities of the tibiofemoral articular surface in a customized PS-TKA by means of a computational simulation. METHODS An adaptive computational simulation method was developed that conduct wear simulation for tibial insert to predict kinematics, weight loss due to wear, and wear contours to results. Wear predictions using computational simulation were performed for 5 million gait cycles with force-controlled inputs. Customized PS-TKA designs were developed and categorized as conventional conformity (CPS-TKA), medial pivot conformity (MPS-TKA), and anatomical conformity (APS-TKA). The post-cam design in the customized PS-TKA is identical. We compared the kinematics, contact mechanics, and wear performance. RESULTS The findings revealed that APS-TKA exhibited the highest internal tibial rotation relative to other TKA designs. Additionally, the higher contact area led to there being less contact stress although it did not directly affect the wear performance. Specifically, MPS-TKA exhibited the lowest volumetric wear. CONCLUSIONS The results of the present study showed that tibiofemoral articular surface conformity should be considered carefully in customized PS-TKA design. Different wear performances were observed with respect to different tibiofemoral conformities. Even though APS-TKA exhibited an inferior wear performance compared to MPS-TKA, it proved to be better in terms of kinematics so its functionality may be improved through the optimization of the tibiofemoral articular surface conformity. Additionally, it should be carefully designed since any changes may affect the post-cam mechanism.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Juhyun Son
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Oh-Ryong Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Sae Kwang Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
14
|
Koh YG, Nam JH, Kang KT. Effect of geometric variations on tibiofemoral surface and post-cam design of normal knee kinematics restoration. J Exp Orthop 2018; 5:53. [PMID: 30578465 PMCID: PMC6303222 DOI: 10.1186/s40634-018-0167-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 11/29/2018] [Indexed: 11/29/2022] Open
Abstract
Background Restoration of natural knee kinematics for a designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty (TKA). In different posterior-stabilized TKAs, there are wide variations in tibiofemoral surfaces and post-cam design. However, it is not known whether these design variations preserve natural knee kinematics. The purpose of this study was to determine the most appropriate tibiofemoral surface and post-cam designs to restore natural knee kinematics of the TKA. Methods A subject-specific finite element knee modal was used to evaluate tibiofemoral surface and post-cam design. Three different posts in convex, straight, and concave geometries were considered with a fixed circular cam design in this study. In addition, this post-cam design was applied to three different surface conformities for conforming, medial pivot, and subject anatomy mimetic tibiofemoral surfaces. We evaluated the femoral rollback, internal-external rotation, and quadriceps muscle force under a deep-knee-bend condition. Results The three different tibiofemoral conformities showed that the convex post provided the most natural-knee-like femoral rollback. This was also observed in internal rotation. In surface conformity, subject anatomy mimetic tibiofemoral surfaces showed the most natural -knee-like kinematics and quadriceps force. Conclusions This study confirmed that convex post design and subject anatomy mimetic tibiofemoral surfaces provided the most natural-knee-like kinematics. This study suggested that post-cam design and tibiofemoral surface conformity should be considered in conventional and customized TKA.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Ji-Hoon Nam
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
15
|
Koh YG, Lee JA, Chung PK, Kang KT. Computational analysis of customized cruciate retaining total knee arthroplasty restoration of native knee joint biomechanics. Artif Organs 2018; 43:504-514. [PMID: 30375662 DOI: 10.1111/aor.13382] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2018] [Revised: 10/17/2018] [Accepted: 10/25/2018] [Indexed: 01/20/2023]
Abstract
The purpose of this study was to verify if customized prosthesis better preserves the native knee joint kinematics and provides lower contact stress on the polyethylene (PE) insert owing to the wider bone preservation than that of standard off-the-shelf prosthesis in posterior cruciate-retaining type total knee arthroplasty (TKA). Validated finite element (FE) models for were developed to evaluate the knee joint kinematics and contact stress on the PE insert after TKA with customized and standard off-the-shelf (OTS) prostheses as well as in normal healthy knee through FE analysis under dynamic loading conditions. The contact stresses on the customized prosthesis decreased by 18% and 8% under gait cycle loading conditions, and 24% and 9% under deep-knee-bend loading conditions, in the medial and lateral sides of the PE insert, respectively, compared with the standard OTS prosthesis. The anterior-posterior translation and internal-external (IE) rotation in customized TKA were more similar to native knee joint behaviors compared with standard OTS TKA under gait loading conditions. The difference from normal knee kinematics was lower for femoral rollback and IE rotation in customized TKA than in standard OTS TKA in the deep-knee-bend condition. In general, customized prostheses achieve kinematics that are close to those of the native healthy knee joint and have better contact stresses than standard OTS prostheses in gait and deep-knee-bend loading conditions.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| | - Pill Ku Chung
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
16
|
Koh YG, Son J, Kwon OR, Kwon SK, Kang KT. Patient-specific design for articular surface conformity to preserve normal knee mechanics in posterior stabilized total knee arthroplasty. Biomed Mater Eng 2018; 29:401-414. [PMID: 30282339 DOI: 10.3233/bme-180998] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
BACKGROUND Contemporary total knee arthroplasty (TKA) provides remarkable clinical benefits. However, the normal function of the knee is not fully restored. Recent improvements in imaging and manufacturing have utilized the development of customized design to fit the unique shape of individual patients. OBJECTIVE The purpose of the present study is to investigate the preservation of normal knee biomechanics by using specific articular surface conformity in customized posterior stabilized (PS)-TKA. METHODS This includes customized PS-TKA, PS-TKA with conforming conformity (CPS-TKA), medial pivot conformity with PS-TKA (MPS-TKA), and PS-TKA with mimetic anatomy femoral and tibial articular surface (APS-TKA). In this study, kinematics, collateral ligament force and quadriceps force were evaluated using a computational simulation under a deep knee bend condition. RESULTS A conventional TKA did not provide the normal internal tibial rotation with flexion leading to abnormal femoral rollback. The APS-TKA exhibited normal-like femoral rollback kinematics but did not exhibit normal internal tibial rotation. However, APS-TKA exhibited the most normal-like collateral ligament and quadriceps forces. CONCLUSIONS Although the APS-TKA exhibited more normal-like biomechanics, it did not restore normal knee biomechanics owing to the absence of the cruciate ligament and post-cam mechanism.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Juhyun Son
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| | - Oh-Ryong Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Sae Kwang Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
17
|
Effect of Post-Cam Design for Normal Knee Joint Kinematic, Ligament, and Quadriceps Force in Patient-Specific Posterior-Stabilized Total Knee Arthroplasty by Using Finite Element Analysis. BIOMED RESEARCH INTERNATIONAL 2018; 2018:2438980. [PMID: 30327775 PMCID: PMC6169244 DOI: 10.1155/2018/2438980] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 07/22/2018] [Indexed: 11/21/2022]
Abstract
The purpose of this study is to investigate post-cam design via finite element analysis to evaluate the most normal-like knee mechanics. We developed five different three-dimensional computational models of customized posterior-stabilized (PS) total knee arthroplasty (TKA) involving identical surfaces with the exception of the post-cam geometry. They include flat-and-flat, curve-and-curve (concave), curve-and-curve (concave and convex), helical, and asymmetrical post-cam designs. We compared the kinematics, collateral ligament force, and quadriceps force in the customized PS-TKA with five different post-cam designs and conventional PS-TKA to those of a normal knee under deep-knee-bend conditions. The results indicated that femoral rollback in curve-and-curve (concave) post-cam design exhibited the most normal-like knee kinematics, although the internal rotation was the closest to that of a normal knee in the helical post-cam design. The curve-and-curve (concave) post-cam design showed a femoral rollback of 4.4 mm less than the normal knee, and the helical post-cam design showed an internal rotation of 5.6° less than the normal knee. Lateral collateral ligament and quadriceps forces in curve-and-curve (concave) post-cam design, and medial collateral ligament forces in helical post-cam design were the closest to that of a normal knee. The curve-and-curve (concave) post-cam design showed 20% greater lateral collateral ligament force than normal knee, and helical post-cam design showed medial collateral ligament force 14% greater than normal knee. The results revealed the variation in each design that provided the most normal-like biomechanical effect. The present biomechanical data are expected to provide useful information to improve post-cam design to restore normal-like knee mechanics in customized PS-TKA.
Collapse
|
18
|
Kang KT, Son J, Suh DS, Kwon SK, Kwon OR, Koh YG. Patient-specific medial unicompartmental knee arthroplasty has a greater protective effect on articular cartilage in the lateral compartment: A Finite Element Analysis. Bone Joint Res 2018; 7:20-27. [PMID: 29305427 PMCID: PMC5805830 DOI: 10.1302/2046-3758.71.bjr-2017-0115.r2] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient's own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA. METHODS The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs. RESULTS The contact stresses on the PE insert were similar for both the PS and standard UKAs. Compared with the standard UKA, the PS UKA did not show any biomechanical effect on the medial PE insert. However, the contact stresses on the articular cartilage and the meniscus in the lateral compartment following the PS UKA exhibited closer values to the healthy knee joint compared with the standard UKA. CONCLUSION The PS UKA provided mechanics closer to those of the normal knee joint. The decreased contact stress on the opposite compartment may reduce the overall risk of progressive osteoarthritis.Cite this article: K-T. Kang, J. Son, D-S. Suh, S. K. Kwon, O-R. Kwon, Y-G. Koh. Patient-specific medial unicompartmental knee arthroplasty has a greater protective effect on articular cartilage in the lateral compartment: A Finite Element Analysis. Bone Joint Res 2018;7:20-27. DOI: 10.1302/2046-3758.71.BJR-2017-0115.R2.
Collapse
Affiliation(s)
- K-T. Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, South Korea
| | - J. Son
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, South Korea
| | - D-S. Suh
- Department of Orthopaedic Surgery, Joint Reconstruction Center, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - S. K. Kwon
- Department of Orthopaedic Surgery, Joint Reconstruction Center, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - O-R. Kwon
- Department of Orthopaedic Surgery, Joint Reconstruction Center, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - Y-G. Koh
- Department of Orthopaedic Surgery, Joint Reconstruction Center, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| |
Collapse
|
19
|
Khosravipour I, Pejhan S, Luo Y, Wyss UP. Customized surface-guided knee implant: Contact analysis and experimental test. Proc Inst Mech Eng H 2017; 232:90-100. [DOI: 10.1177/0954411917744586] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Contact pressure and stresses on the articulating surface of the tibial component of a total knee replacement are directly related to the joint contact forces and the contact area. These stresses can result in wear and fatigue damage of the ultra-high-molecular-weight polyethylene. Therefore, conducting stress analysis on a newly designed surface-guided knee implant is necessary to evaluate the design with respect to the polyethylene wear. Finite element modeling is used to analyze the design’s performance in level walking, stair ascending and squatting. Two different constitutive material models have been used for the tibia component to evaluate the effect of material properties on the stress distribution. The contact pressure results of the finite element analysis are compared with the results of contact pressure using pressure-sensitive film tests. In both analyses, the average contact pressure remains below the material limits of ultra-high-molecular-weight polyethylene insert. The peak von Mises stresses in 90° of flexion and 120° of flexion (squatting) are 16.28 and 29.55 MPa, respectively. All the peak stresses are less than the fatigue failure limit of ultra-high-molecular-weight polyethylene which is 32 MPa. The average contact pressure during 90° and 120° of flexion in squatting are 5.51 and 5.46 MPa according to finite element analysis and 5.67 and 8.14 MPa according to pressure-sensitive film experiment. Surface-guided knee implants are aimed to resolve the limitations in activities of daily living after total knee replacement by providing close to normal kinematics. The proposed knee implant model provides patterns of motion much closer to the natural target, especially as the knee flexes to higher degrees during squatting.
Collapse
Affiliation(s)
- Ida Khosravipour
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Shabnam Pejhan
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Yunhua Luo
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Urs P Wyss
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada
| |
Collapse
|
20
|
Koh YG, Son J, Kwon SK, Kim HJ, Kwon OR, Kang KT. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017; 6:557-565. [PMID: 28947604 PMCID: PMC5631000 DOI: 10.1302/2046-3758.69.bjr-2016-0250.r1] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Accepted: 06/30/2017] [Indexed: 12/11/2022] Open
Abstract
Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1.
Collapse
Affiliation(s)
- Y-G Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - J Son
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - S-K Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - H-J Kim
- Spine Center and Department of Orthopaedic Surgery, Seoul National University College of Medicine and Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beongil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, South Korea
| | - O-R Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - K-T Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| |
Collapse
|
21
|
Malpositioning of Prosthesis: Patient-specific Total Knee Arthroplasty Versus Standard Off-the-Shelf Total Knee Arthroplasty. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS 2017; 1:e020. [PMID: 30211354 PMCID: PMC6132303 DOI: 10.5435/jaaosglobal-d-17-00020] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Introduction: A recent study has challenged the premise that a patient-specific (PS)–designed total knee arthroplasty (TKA) component has better clinical survival than an off-the-shelf (OTS) prosthesis. Methods: We developed the finite element models for PS TKA and OTS TKA with 5° varus and valgus malalignment and 5° internal and external malrotations. Results: Contact stress on the medial side of the insert increased with internal femoral malrotation and varus tibial malalignment, but it decreased with external femoral malrotation and varus tibial malalignment in both PS TKA and OTS TKA. An increase in ligament force occurred in valgus malalignment and external malrotation, and in particular, the force exerted on the medial collateral ligament increased. However, PS TKA provided better biomechanical effects than did the standard OTS TKA with malpositioning in TKA. Discussion: These results emphasize the importance of precise surgical preservation in regard to the TKA position.
Collapse
|
22
|
Pejhan S, Bohm E, Brandt JM, Wyss U. Design and virtual evaluation of a customized surface-guided knee implant. Proc Inst Mech Eng H 2016; 230:949-61. [PMID: 27574038 DOI: 10.1177/0954411916663839] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Accepted: 07/19/2016] [Indexed: 11/16/2022]
Abstract
Although total knee arthroplasty is generally a successful operation, many studies have shown that it results in significant alterations in the kinematics of the joint, which cause limitations in performing the activities of daily living. This study aimed to define the design features for a customized surface-guided total knee replacement and to evaluate the kinematic outcomes. Magnetic resonance imaging data of the knee joint are used to generate the design features as they relate to the functionality of the implant. The motion is guided by considering a partial ball and socket configuration on the medial condyle and varying radii of curvature on the lateral articulating surface. A virtual simulation of the behavior of the surface-guided total knee replacement was performed to investigate the motion patterns of this total knee replacement under gait and squatting loading conditions. Results of the virtual simulation show that flexion and extension of the knee make the center of the lateral condyle move more naturally in the posterior and anterior directions, in comparison to the center of the medial condyle. Such guidance is achieved as a result of the novel customized designed contact between the articulating surfaces. The proposed customized surface-guided total knee replacement provides patterns of motion close to the expected more natural target, not only during a gait cycle but also as the knee flexes to higher degrees during squatting. Major design features include location and orientation of the flexion and pivoting axes, the trace of the contact points on the tibia, and the radii of the guiding arcs on the lateral condyle.
Collapse
Affiliation(s)
- Shabnam Pejhan
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Eric Bohm
- Orthopaedic Innovation Centre, Winnipeg, MB, Canada Department of Surgery, Section of Orthopedic Surgery, University of Manitoba, Winnipeg, MB, Canada
| | - Jan-Mels Brandt
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Urs Wyss
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada Orthopaedic Innovation Centre, Winnipeg, MB, Canada
| |
Collapse
|