1
|
Josic U, Teti G, Ionescu A, Maravic T, Mazzitelli C, Cokic S, Van Meerbeek B, Falconi M, Brambilla E, Mazzoni A, Breschi L. Cytotoxicity and microbiological behavior of universal resin composite cements. Dent Mater 2024; 40:1515-1523. [PMID: 39054113 DOI: 10.1016/j.dental.2024.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 07/08/2024] [Accepted: 07/22/2024] [Indexed: 07/27/2024]
Abstract
OBJECTIVES To investigate the cytotoxicity on human dental pulp cells (HDPCs) and Streptococcus mutans (S.mutans) biofilm formation on universal resin composite cements (UCs). METHODS Three UCs (RelyX Universal, 3 M Oral Care - RXU; Panavia SA Cement Universal, Kuraray Noritake - PSAU; SoloCem, Coltene - SCM) and one 'gold-standard' multi-step cement (Panavia V5, Kuraray Noritake - PV5) were used following two polymerization protocols (light-cured - LC; self-cured - SC). Cytotoxicity (MTT) tests were performed after 1, 3 and 7 days of direct contact. Carboxy-2',7'-dichlorodihydrofluorescein diacetate was used to detect the release of reactive oxygen species (ROS), and interleukin 6 (IL-6) expression was analyzed by IL-6 proquantum high sensitivity immunoassay. S. mutans biofilms were grown on UCs samples in a bioreactor for 24 h, then adherent viable biomass was assessed using MTT assay. For microbiological procedures, half of UCs samples underwent accelerated aging. Data were statistically analyzed (α = 0.05). RESULTS The highest cytotoxicity was observed for PSAU SC, RXU SC, and PV5 SC at day 1, then for SC RXU after 3 days, and SC PSAU, LC PV5 and SCM after 1-week (p < 0.05). There was no increase in IL-6 expression after 1 day, while it increased depending on the group at 3 and 7 days. The highest ROS expression after 12 h was recorded for PSAU SC, PV5 SC and PV5 LC. Biofilm formation was as follows: RXU > > PSAU = PV5 > SCM, while light-curing systematically decreased biofilm formation (≈-33 %). Aging leveled out differences between UCs and between polymerization protocols. SIGNIFICANCE The choice of cement brand, rather than category, and polymerization protocol influence cell viability and microbiological behavior. Light-curing is beneficial for reducing the harmful pulpal effect that UCs may possess.
Collapse
Affiliation(s)
- Uros Josic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Gabriella Teti
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Andrei Ionescu
- Oral Microbiology and Biomaterials Laboratory, Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Tatjana Maravic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Stevan Cokic
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven (UZ Leuven), Dentistry, Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven (UZ Leuven), Dentistry, Leuven, Belgium
| | - Mirella Falconi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Eugenio Brambilla
- Oral Microbiology and Biomaterials Laboratory, Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Annalisa Mazzoni
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Lorenzo Breschi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy.
| |
Collapse
|
2
|
Gonçalves F, Ayala-Perez MD, Reis FCDS, Miranda-Júnior WG, Boaro LCC. Exploring Zirconia Adhesion: Pre and Postsintering Physical Surface Treatment, Chemical Treatment, and Cement Interactions. BIOMED RESEARCH INTERNATIONAL 2024; 2024:5394652. [PMID: 39220997 PMCID: PMC11362578 DOI: 10.1155/2024/5394652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/31/2024] [Indexed: 09/04/2024]
Abstract
Background: Adhesion to zirconia remains a significant dental challenge. This study is aimed at assessing the bond strength of zirconia based on surface treatment with pre or postsintering sandblasting associated with different chemical treatments and resin cements. Methods: Zirconia blocks were divided into 12 experimental groups based on the surface treatment (presintering sandblasting or postsintering sandblasting/tribochemical abrasion treatment), chemical treatment (none, Single Bond Universal, or Signum Zirconia Bond), and choice of cement (Panavia F or RelyX™ U200). The bond strength was measured by shear tests using a universal testing machine. The fracture analysis was performed using stereomicroscopy. Data were analyzed using three-way ANOVA and Tukey's test (α = 5%). Results: Triple and double factor's interactions were not significant (p > 0.05). Regarding the surface treatment factor, the bond strength following postsintering sandblasting treatment associated with tribochemical abrasion (9.15 ± 3.62 MPa) was significantly higher than presintering sandblasting treatment (5.24 ± 3.53 MPa). Concerning the chemical treatment factor, bond strengths were ranked as follows: Signum Zirconia Bond > Single Bond Universal > no treatment. The bond strength of the resin cements did not differ among them. Most fractures (67%) were classified as adhesive, and 32% were categorized as mixed fractures. Conclusion: Surface treatment via postsintering sandblasting combined with tribochemical abrasion demonstrated superior efficacy than in presintering sandblasting. Additionally, chemical treatment with zirconia primer increased the bond strength of zirconia irrespective of the surface physical treatment.
Collapse
Affiliation(s)
- Flávia Gonçalves
- Faculdade de OdontologiaUniversidade Santo Amaro, Av. Prof. Eneas de Siqueira Neto, 340 04829-900, São Paulo, SP, Brazil
| | - Mirko Dennys Ayala-Perez
- Faculdade de OdontologiaUniversidade Santo Amaro, Av. Prof. Eneas de Siqueira Neto, 340 04829-900, São Paulo, SP, Brazil
| | | | - Walter Gomes Miranda-Júnior
- Departamento de Biomateriais e Biologia OralFaculdade de Odontologia da Universidade de São Paulo, Av. Prof. Lineu Prestes, 2222 05508-000, São Paulo, SP, Brazil
| | | |
Collapse
|
3
|
Irie M, Okada M, Maruo Y, Nishigawa G, Matsumoto T. Long-Term Bonding Performance of One-Bottle vs. Two-Bottle Bonding Agents to Lithium Disilicate Ceramics. Polymers (Basel) 2024; 16:2266. [PMID: 39204486 PMCID: PMC11359450 DOI: 10.3390/polym16162266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 08/02/2024] [Accepted: 08/03/2024] [Indexed: 09/04/2024] Open
Abstract
The aim of this study was to compare the long-term bonding performance to lithium disilicate (LDS) ceramic between one-bottle and two-bottle bonding agents. Bonding performance was investigated under these LDS pretreatment conditions: with hydrofluoric acid (HF) only, without HF, with a two-bottle bonding agent (Tokuyama Universal Bond II) only. Shear bond strengths between LDS and nine resin cements (both self-adhesive and conventional adhesive types) were measured at three time periods: after one-day water storage (Base), and after 5000 and 20,000 thermocycles (TC 5k and TC 20k respectively). Difference in degradation between one- and two-bottle bonding agents containing the silane coupling agent was compared by high-performance liquid chromatography. With HF pretreatment, bond strengths were not significantly different among the three time periods for each resin cement. Without HF, ESTECEM II and Super-Bond Universal showed significantly higher values than others at TC 5k and TC 20k when treated with the recommended bonding agents, especially at TC 20k. Difference in degradation between one- and two-bottle bonding agents containing the silane coupling agent was compared by high-performance liquid chromatography (HPLC). For both cements, these values at TC 20k were also not significantly different from pretreatment with only Tokuyama Universal Bond II. For LDS, long-term bond durability could be maintained by pretreatment with Tokuyama Universal Bond II instead of the hazardous HF.
Collapse
Affiliation(s)
- Masao Irie
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan;
| | - Masahiro Okada
- Department of Dental Biomaterials, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan;
| | - Yukinori Maruo
- Department of Prosthodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan; (Y.M.); (G.N.)
| | - Goro Nishigawa
- Department of Prosthodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan; (Y.M.); (G.N.)
| | - Takuya Matsumoto
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan;
| |
Collapse
|
4
|
Chen TA, Lu PY, Lin PY, Chi CW, Cheng HY, Lai YJ, Wang F, Chiang YC. Effects of ceramic thickness, ceramic translucency, and light transmission on light-cured bulk-fill resin composites as luting cement of lithium disilicate based-ceramics. J Prosthodont Res 2024; 68:255-263. [PMID: 37197947 DOI: 10.2186/jpr.jpr_d_22_00304] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
PURPOSE To assess the effects of ceramic thickness, ceramic translucency, and light transmission on restorative composites used as luting cement for lithium disilicate-based ceramics. METHODS Four luting types of cement were tested (n=8); a dual-cured resin cement (Multilink N), a light-cured conventional flowable composite (Tetric N-Flow), and two light-cured bulk-fill flowable composites (Tetric N-Flow Bulk Fill and X-tra base). The 20 s- or 40 s-light (1000 mW/cm2) was transmitted through 1- or 2-mm-thick high- or low-translucency (HT- or LT-) ceramic discs (IPS e.Max press) to reach the 1-mm-thick luting cement. Light transmitted to cement without ceramic served as a control. Vickers hardness number (VHN), flexural strength (FS), fractography, and degree of conversion (DC) were evaluated. One-way and multi-way analysis of variance was conducted to determine the effects of factors on VHN and FS. RESULTS Ceramic thickness, light transmission time, and cement type significantly affected the VHN of the luting cement (P < .000). Only Multilink N (LT- and HT-1mm) and Tetric N-Flow (HT-1mm) reached 90% VHN of corresponding control by 20 s-light transmissions, but Tetric N-Flow exhibited lowest VHN and approximately 1/3-1/2 VHN of Multilink N (P < 0.05). X-tra base expressed superior physicochemical properties to Tetric N-Flow Bulk Fill (P < 0.05) and reached >90% VHN of control in all conditions with 40 s-light transmissions except for LT-2 mm. DC, FS, and fractography supported these findings. CONCLUSIONS The light-cured bulk-fill composite served as a luting cement for lithium-disilicate-based ceramics in a product-dependent manner. Light transmission time is crucial to ensure sufficient luting cement polymerization.
Collapse
Affiliation(s)
- Ting-An Chen
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
| | - Pei-Ying Lu
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
| | - Po-Yen Lin
- Department of Dentistry, School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chih-Wen Chi
- Department of Dentistry, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu City, Taiwan
| | - Hon Yin Cheng
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
| | - Yu-Jung Lai
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
| | - Fajen Wang
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
| | - Yu-Chih Chiang
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
- Molecular Imaging Center, National Taiwan University, Taipei, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
5
|
Fouquet V, Dantagnan CA, Abdel-Gawad S, Dursun E, Attal JP, François P. In vitro shear bond strength over zirconia and titanium alloy and degree of conversion of extraoral compared to intraoral self-adhesive resin cements. BDJ Open 2023; 9:54. [PMID: 38071342 PMCID: PMC10710444 DOI: 10.1038/s41405-023-00178-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 03/18/2025] Open
Abstract
OBJECTIVE Evaluation of the Shear bond strength over zirconia and titanium alloy and degree of conversion of extraoral compared to intraoral self-adhesive resin cements. MATERIALS AND METHODS Nine bonding protocols were carried out on zirconia 4Y-TZP and titanium alloy (Ti-6Al-4V). Seven resin cement (one extraoral and six intraoral) were tested in the shear bond strength test and the degree of conversion measurements. RESULTS The significantly highest value was obtained for Monobond Plus + Multilink Hybrid Abutment, the extraoral resin cement for both titanium alloy (35.1 MPa) and zirconia (32.9 MPa). For each resin, significantly higher DC values were obtained for the dual-cure mode compared with the self-cure mode. Regardless of the cure mode, Nexus Universal reached the highest DC (78.4%). DISCUSSION/CONCLUSIONS In this study, the extraoral self-curing resin cement showed the higher bond strength values on zirconia and titanium alloy when associated with a universal primer. Some intraoral dual-cure resin cements showed closed performances when used with universal primers. There is no direct correlation between the degree of conversion of the resin cement and the shear bond strength obtained on the prosthetic materials tested.
Collapse
Affiliation(s)
- Vincent Fouquet
- Université Paris Cité, Faculté de Santé, UFR d'Odontologie, Paris, France.
- Innovative Dental Materials and Interfaces Research Unit (URP 4462), Montrouge, France.
- Hôpital Louis-Mourier, AP-HP, Colombes, France.
| | - Claire-Adeline Dantagnan
- Université Paris Cité, Faculté de Santé, UFR d'Odontologie, Paris, France
- Innovative Dental Materials and Interfaces Research Unit (URP 4462), Montrouge, France
- Hôpital Pitié-Salpétrière, AP-HP, Paris, France
| | - Sarah Abdel-Gawad
- Université Paris Cité, Faculté de Santé, UFR d'Odontologie, Paris, France
- Innovative Dental Materials and Interfaces Research Unit (URP 4462), Montrouge, France
| | - Elisabeth Dursun
- Université Paris Cité, Faculté de Santé, UFR d'Odontologie, Paris, France
- Innovative Dental Materials and Interfaces Research Unit (URP 4462), Montrouge, France
- Hôpital Henri-Mondor, AP-HP, Créteil, France
| | - Jean-Pierre Attal
- Université Paris Cité, Faculté de Santé, UFR d'Odontologie, Paris, France
- Innovative Dental Materials and Interfaces Research Unit (URP 4462), Montrouge, France
- Hôpital Charles-Foix, AP-HP, Ivry-sur-Seine, France
| | - Philippe François
- Université Paris Cité, Faculté de Santé, UFR d'Odontologie, Paris, France
- Innovative Dental Materials and Interfaces Research Unit (URP 4462), Montrouge, France
- Hôpital Bretonneau, AP-HP, Paris, France
| |
Collapse
|
6
|
Anuntasainont M, Po-Ngam N, Lührs AK, Neoh SP, Pongprueksa P. Fracture resistance of CAD/CAM blocks cemented on dentin using different cementation strategies. J Prosthodont Res 2023; 67:603-609. [PMID: 36792222 DOI: 10.2186/jpr.jpr_d_22_00196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
Abstract
PURPOSE To determine whether the fracture resistance of computer-aided design/computer-aided manufacturing (CAD/CAM) resin-based composites and polymer-infiltrated ceramic network materials cemented on dentin is influenced by the restoration thickness and composite cement application strategy. METHODS Disc-shaped specimens (Ø = 7 mm) of 0.8 mm and 1.5 mm thicknesses were milled from two CAD/CAM materials: resin-based composite (RBC, Cerasmart 270) and polymer-infiltrated ceramic network (PICN, Vita Enamic). The discs (n = 8 per group) were cemented on flattened dentin using three different cementation strategies: 1) self-adhesive composite cement (RelyX U200) in light-curing mode (LC-SAC), 2) universal adhesive (Single Bond Universal) with composite cement (RelyX Ultimate) in auto-curing mode (AC cement), and 3) adhesive and composite cement as in 2) but in light-curing mode (LC cement). The restorative surface was indented perpendicularly with a compressive load using a universal testing machine until fracture. The fracture resistance (N) of RBC and PICN was separately analyzed using two-way ANOVA and Tukey's post-hoc test (α = 0.05). RESULTS The fracture resistance of each material was significantly influenced by the material thickness and cementation strategy (P < 0.05). Irrespective of the material type and cementation strategy, thicker materials exhibit higher fracture resistance. For RBC, the fracture resistance of the LC cement group was significantly higher than that of AC cement only at 0.8 mm thickness. For PICN, the LC-cement cementation strategy produced superior fracture resistance, regardless of the restoration thickness. CONCLUSIONS The fracture resistance of Cerasmart 270 was higher for the thicker material; the fracture resistance of LC cement was higher than that of AC cement at 0.8 mm thickness cemented to dentin. In comparison, LC cement showed the highest fracture resistance for Vita Enamic for both material thicknesses.
Collapse
Affiliation(s)
- Munlika Anuntasainont
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Nanthiphorn Po-Ngam
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Anne-Katrin Lührs
- Department of Conservative Dentistry, Periodontology and Preventive Dentistry, Hannover Medical School, Hannover, Germany
| | - Siew Peng Neoh
- Department of Orthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Pong Pongprueksa
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| |
Collapse
|
7
|
Irie M, Okada M, Maruo Y, Nishigawa G, Matsumoto T. Shear Bond Strength of Resin Luting Materials to Lithium Disilicate Ceramic: Correlation between Flexural Strength and Modulus of Elasticity. Polymers (Basel) 2023; 15:polym15051128. [PMID: 36904369 PMCID: PMC10006982 DOI: 10.3390/polym15051128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 02/16/2023] [Accepted: 02/16/2023] [Indexed: 02/26/2023] Open
Abstract
This study investigates the effect of the curing mode (dual-cure vs. self-cure) of resin cements (four self-adhesive and seven conventional cements) on their flexural strength and flexural modulus of elasticity, alongside their shear bond strength to lithium disilicate ceramics (LDS). The study aims to determine the relationship between the bond strength and LDS, and the flexural strength and flexural modulus of elasticity of resin cements. Twelve conventional or adhesive and self-adhesive resin cements were tested. The manufacturer's recommended pretreating agents were used where indicated. The shear bond strengths to LDS and the flexural strength and flexural modulus of elasticity of the cement were measured immediately after setting, after one day of storage in distilled water at 37 °C, and after 20,000 thermocycles (TC 20k). The relationship between the bond strength to LDS, flexural strength, and flexural modulus of elasticity of resin cements was investigated using a multiple linear regression analysis. For all resin cements, the shear bond strength, flexural strength, and flexural modulus of elasticity were lowest immediately after setting. A clear and significant difference between dual-curing and self-curing modes was observed in all resin cements immediately after setting, except for ResiCem EX. Regardless of the difference of the core-mode condition of all resin cements, flexural strengths were correlated with the LDS surface upon shear bond strengths (R2 = 0.24, n = 69, p < 0.001) and the flexural modulus of elasticity was correlated with them (R2 = 0.14, n = 69, p < 0.001). Multiple linear regression analyses revealed that the shear bond strength was 17.877 + 0.166, the flexural strength was 0.643, and the flexural modulus was (R2 = 0.51, n = 69, p < 0.001). The flexural strength or flexural modulus of elasticity may be used to predict the bond strength of resin cements to LDS.
Collapse
Affiliation(s)
- Masao Irie
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Okayama 700-8525, Japan
- Correspondence: ; Tel.: +81-86-235-6668
| | - Masahiro Okada
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Okayama 700-8525, Japan
| | - Yukinori Maruo
- Department of Prosthodontics, Division of Dentistry, Okayama University, 2-5-1 Shikata-cho, Okayama 700-8525, Japan
| | - Goro Nishigawa
- Department of Prosthodontics, Division of Dentistry, Okayama University, 2-5-1 Shikata-cho, Okayama 700-8525, Japan
| | - Takuya Matsumoto
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Okayama 700-8525, Japan
| |
Collapse
|
8
|
Influence of the activation mode on long-term bond strength and endogenous enzymatic activity of dual-cure resin cements. Clin Oral Investig 2021; 26:1683-1694. [PMID: 34471955 PMCID: PMC8816763 DOI: 10.1007/s00784-021-04141-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 08/11/2021] [Indexed: 11/23/2022]
Abstract
Objective To investigate the long-term microtensile bond strength (µTBS), interfacial nanoleakage expression (NL), and adhesive stability of dual-cure resin cements with/out light activation to dentin. Materials and methods Composite overlays (N = 20) were luted to deep dentin surfaces with RelyX Ultimate (RXU, 3M) or Variolink EstheticDC (VAR, Ivoclar-Vivadent). A universal adhesive was used for bonding procedures (iBond universal, Heraeus Kulzer). The resin cements were either self-cured (SC; 1 h at 37 °C) or dual-cured (DC; 20s light-cure followed by 15 min self-cure at 37 °C). Specimens were submitted to µTBS immediately (T0) or after 1 year of laboratory storage (T12). The fracture pattern was evaluated using scanning electron microscopy (SEM). Data were statistically analyzed with two-way ANOVA/Tukey test. Further, the NL was quantified and analyzed (chi-square test) and in situ zymography was performed to evaluate the endogenous enzymatic activity within the hybrid layer (HL) at T0 and T12 (Mann–Whitney test). The significance level for all statistical tests was set at p = 0.05. Results DC resulted in higher bond strength and decreased fluorescence at the adhesive interface, irrespective of the material and the storage period (p < 0.05). Significantly lower bonding performances (p < 0.05) and higher endogenous enzymatic activity (p < 0.05) were observed within the HL at T12 compared to T0 in all tested groups. Conclusions Light-curing the dual-cure resin cements, more than the cement materials, accounted for good bonding performances and higher HL stability over time when used with a universal adhesive. Clinical significance The curing condition influences the bonding performances of dual-cure resin cements to dentin when used with a universal adhesive.
Collapse
|
9
|
Characterization of Experimental Short-Fiber-Reinforced Dual-Cure Core Build-Up Resin Composites. Polymers (Basel) 2021; 13:polym13142281. [PMID: 34301038 PMCID: PMC8309262 DOI: 10.3390/polym13142281] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/07/2021] [Accepted: 07/08/2021] [Indexed: 12/28/2022] Open
Abstract
As a core build-up material, dual-cured (DC) resin-based composites are becoming popular. The aim of this research was to investigate specific physical and handling properties of new experimental short-fiber-reinforced DC resin composites (SFRCs) in comparison to different commercial, conventional DC materials (e.g., Gradia Core, Rebilda DC, LuxaCore Z, and Visalys® CemCore). Degree of monomer conversion (DC%) was determined by FTIR-spectrometry using either self- or light-curing mode. The flexural strength, modulus, and fracture toughness were calculated through a three-point bending setup. Viscosity was analyzed at room (22 °C) and mouth (35 °C) temperatures with a rotating disk rheometer. The surface microstructure of each resin composite was examined with scanning electron microscopy (SEM). Data were statistically analyzed with analysis of variance ANOVA (p = 0.05). The curing mode showed significant (p < 0.05) effect on the DC% and flexural properties of tested DC resin composites and differences were material dependent. SFRC exhibited the highest fracture toughness (2.3 MPa m1/2) values and LuxaCore showed the lowest values (1 MPa m1/2) among the tested materials (p < 0.05). After light curing, Gradia Core and SFRCs showed the highest flexural properties (p < 0.05), while the other resin composites had comparable values. The novel DC short-fiber-reinforced core build-up resin composite demonstrated super fracture toughness compared to the tested DC conventional resin composites.
Collapse
|