1
|
Muhi A, Ichikawa T, Motosugi U, Sou H, Nakajima H, Sano K, Sano M, Kato S, Kitamura T, Fatima Z, Fukushima K, Iino H, Mori Y, Fujii H, Araki T. Diagnosis of colorectal hepatic metastases: Comparison of contrast-enhanced CT, contrast-enhanced US, superparamagnetic iron oxide-enhanced MRI, and gadoxetic acid-enhanced MRI. J Magn Reson Imaging 2011; 34:326-35. [DOI: 10.1002/jmri.22613] [Citation(s) in RCA: 123] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
2
|
Muhi A, Ichikawa T, Motosugi U, Sou H, Nakajima H, Sano K, Kitamura T, Faima Z, Fukushima K, Araki T, Iino H, Mori Y, Fujii H. Diagnosis of colorectal hepatic metastases: Contrast-enhanced ultrasonography versus contrast-enhanced computed tomography versus superparamagnetic iron oxide-enhanced magnetic resonance imaging with diffusion-weighted imaging. J Magn Reson Imaging 2010; 32:1132-40. [DOI: 10.1002/jmri.22360] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
3
|
Sugimoto K, Shiraishi J, Moriyasu F, Saito K, Doi K. Improved detection of hepatic metastases with contrast-enhanced low mechanical-index pulse inversion ultrasonography during the liver-specific phase of sonazoid: observer performance study with JAFROC analysis. Acad Radiol 2009; 16:798-809. [PMID: 19394876 DOI: 10.1016/j.acra.2008.12.025] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2008] [Revised: 12/22/2008] [Accepted: 12/24/2008] [Indexed: 12/27/2022]
Abstract
RATIONALE AND OBJECTIVES To compare B-mode ultrasonography (US) alone with the combination of B-mode and contrast-enhanced (Sonazoid) late-phase pulse-inversion US for the detection of hepatic metastases by use of jackknife free-response receiver-operating characteristic (JAFROC) analysis. MATERIALS AND METHODS Twenty-seven patients with 57 hepatic metastases and 6 patients without hepatic metastases underwent B-mode and contrast-enhanced US. We used the diagnoses established by contrast-enhanced computed tomography and contrast-enhanced US as the standard of reference. All ultrasonographic scanning was performed by an experienced radiologist with a routine clinical procedure. All scanning data were archived with digital cine clips. A review system, which can display pairs of cine clips for B-mode and contrast-enhanced US side by side, was developed for off-site observer study. Seven radiologists interpreted each case individually first by B-mode US only, and then by the combination with contrast-enhanced US by identifying locations of possible candidates for hepatic metastasis with their confidence ratings. The figure-of-merit (FOM) values, sensitivity, and false-positives per case were estimated for B-mode US alone, and for the combination of B-mode and contrast-enhanced US. RESULTS The sensitivities of the combined ultrasonographic imaging (mean, 72.2%) were clearly improved from that of B-mode US alone (mean, 41.6%) while reducing the average number of false positives from 1.1 to 0.5 per case. In the jackknife analysis, there was a statistically significant difference between mean FOM values for the combined imaging (0.76) and for B-mode US alone (0.44, P < .00001). CONCLUSION Evaluating cine clips of contrast-enhanced liver US together with B-mode US could improve physicians' accuracy for detection of hepatic metastases.
Collapse
Affiliation(s)
- Katsutoshi Sugimoto
- Kurt Rossmann Laboratories for Radiologic Imaging Research, Department of Radiology, The University of Chicago, 5841 S. Maryland Ave., MC 2026, Chicago, IL 60637, USA.
| | | | | | | | | |
Collapse
|
4
|
Imaging of small hepatic metastases of colorectal carcinoma: how to use superparamagnetic iron oxide-enhanced magnetic resonance imaging in the multidetector-row computed tomography age? J Comput Assist Tomogr 2009; 33:266-72. [PMID: 19346857 DOI: 10.1097/rct.0b013e31817f5c82] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
PURPOSE To compare the accuracy of dynamic contrast-enhanced multidetector-row computed tomography (CT) and superparamagnetic iron oxide-enhanced magnetic resonance imaging (MRI) in the evaluation of small hepatic metastases of colorectal carcinoma. MATERIALS AND METHODS Of 94 patients with colorectal carcinoma analyzed, 76 hepatic metastases (<2 cm) were diagnosed in 17 patients. Superparamagnetic iron oxide (SPIO)-magnetic resonance (precontrast and postcontrast MRI) and dynamic contrast-enhanced multidetector-row CT (dynamic CT [precontrast, arterial, portal-venous, and delayed phase]) were evaluated. The alternative free-response receiver operating characteristic analysis was performed, and the sensitivities and positive predictive values were analyzed. RESULTS The Az values and sensitivities of portal-venous phase CT, dynamic CT, and SPIO-MRI (0.62/59%, 0.69/61%, and 0.67/61%) were identical. The mean positive predictive value of dynamic CT (82%) was inferior to that of SPIO-MRI (91%). CONCLUSIONS The diagnostic ability of dynamic CT is identical to that of SPIO-MRI in Az value and sensitivity. Superparamagnetic iron oxide-MRI should be recommended only if an equivocal lesion is detected by dynamic CT.
Collapse
|
5
|
Power Doppler ultrasonography with time-signal intensity curves in monitoring hepatocellular carcinoma and liver metastases after intralesional therapy. Radiol Med 2008; 114:32-41. [DOI: 10.1007/s11547-008-0324-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2007] [Accepted: 12/10/2007] [Indexed: 12/12/2022]
|
6
|
Song HP, Yu M, Zhang J, Han ZH, Su HL, Ren XL, Wei ZR, Luo W, He JG, Zhou XD. Hemostasis of active bleeding from the liver with percutaneous microwave coagulation therapy under contrast-enhanced ultrasonographic guidance: an experimental study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2008; 27:867-874. [PMID: 18499846 DOI: 10.7863/jum.2008.27.6.867] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE The purpose of this study was to investigate the feasibility of percutaneous microwave coagulation therapy (PMCT) guided by contrast-enhanced ultrasonography (CEUS) for controlling active bleeding in rabbit livers. METHODS Twenty actively bleeding rabbit liver models, produced with an 18-gauge semiautomatic biopsy needle and confirmed with CEUS, were randomly divided into 2 groups: a PMCT group (n=10, with a microwave antenna placed into the bleeding site under ultra-sonographic guidance and worked at 60 W for 30 seconds on average) and a control group (n=10, with the active bleeding site not treated). After therapy procedures were performed, lactated Ringer's solution resuscitation was then performed in both groups to maintain the mean arterial pressure at 70 mm Hg for 1 hour. The intraperitoneal blood loss, total resuscitation volume, mean arterial pressure, and hematocrit value were recorded. Macroscopic and microscopic examinations were performed at the end of the study. RESULTS After PMCT, the former bleeding site appeared on CEUS as a round or an oval area devoid of contrast. The PMCT group had lower blood loss (30.4+/-7.2 versus 101.6 +/- 18.2 mL; P< .05) and a lower total resuscitation volume (56.5+/-10 versus 186+/-36.6 mL; P< .05) than the control group. The mean hematocrit value in the PMCT group was significantly higher than that in the control group (26%+/-4% versus 19%+/-4%; P< .05) at the end of the experiment. CONCLUSIONS Contrast-enhanced ultrasonographically guided PMCT significantly decreased blood loss in a rabbit model of active liver bleeding. It provides a simple and quick method to control blood loss in liver injuries with active bleeding.
Collapse
Affiliation(s)
- Hong-Ping Song
- Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, 17 W Changle Rd, 710032 Xi'an, China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
|
8
|
Luo W, Zderic V, Carter S, Crum L, Vaezy S. Detection of bleeding in injured femoral arteries with contrast-enhanced sonography. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2006; 25:1169-77. [PMID: 16929018 DOI: 10.7863/jum.2006.25.9.1169] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
OBJECTIVE The purpose of this study was to investigate the feasibility of detecting acute arterial bleeding by means of contrast-enhanced sonography. METHODS Puncture injury was produced transcutaneously with an 18-gauge needle in 26 femoral arteries (13 in the control group and 13 in the contrast-enhanced group) of rabbits. A sonographic contrast agent (Optison; Mallinckrodt Inc, St Louis, MO) was administered intravenously at a dose of 0.06 to 0.07 mL/kg. Sonography of the femoral arteries was performed before and after injury, both before and after injection of Optison, with B-mode imaging, color Doppler imaging, and pulse inversion harmonic imaging (PIHI). RESULTS The specific location of active bleeding could not be visualized in B-mode and PIHI scans in the control group (no Optison injection). After administration of Optison, the bleeding site was visualized because of the increased echogenicity of the extravasated blood at the puncture site in both B-mode imaging and PIHI. In color Doppler images, bleeding sites were localized successfully in 84.6% of the cases in the presence of Optison and in 30.8% of the cases without Optison. Histologic examination (light microscopy) of the hematoma confirmed the presence of contrast agent microbubbles in the extravascular space surrounding the artery. CONCLUSIONS Contrast-enhanced sonography may provide an effective method for detecting arterial bleeding.
Collapse
Affiliation(s)
- Wenbo Luo
- Department of Bioengineering, University of Washington, Box 355061, Seattle, 98195, USA.
| | | | | | | | | |
Collapse
|
9
|
Gültekin S, Yücel C, Ozdemir H, Celik H, Oktar SO, Araç M. The role of late-phase pulse inversion harmonic imaging in the detection of occult hepatic metastases. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2006; 25:1139-45. [PMID: 16929014 DOI: 10.7863/jum.2006.25.9.1139] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
OBJECTIVE The purpose of this study was to investigate the efficacy of late-phase pulse inversion harmonic imaging (PIHI) in detecting occult metastases and to compare the results with helical computed tomography (CT) in a group of patients whose fundamental liver sonographic results were normal. METHODS Thirty-two patients (21 women and 11 men; age range, 20-87 years) with a known primary malignancy were enrolled in the study. The patients were evaluated with conventional sonography, unenhanced PIHI, and PIHI 3 minutes after the injection of Levovist (SH U 508A; Schering AG, Berlin, Germany). All patients also underwent triphasic helical CT within 1 week after sonography. In 1 patient, mangafodipir-enhanced magnetic resonance imaging was performed as part of the clinical workup. RESULTS After Levovist injection, in 4 (12.5%) of 32 patients, at least 1 hypoechoic lesion was detected by PIHI; multiple lesions were shown in 1 patient. The mean diameter of newly detected lesions was 12 mm. Triphasic helical CT also showed all of the lesions that were detected by PIHI. The diagnoses were confirmed by biopsy and CT findings in 2 patients and by the typical CT and magnetic resonance imaging findings in 1 patient. For the fourth patient, the diagnosis was confirmed by follow-up and CT. Conclusions. Late-phase PIHI is comparable to helical CT for detecting occult hepatic metastases, but it protects patients from the potentially hazardous effects of radiation and iodinated contrast agents. Further series involving a larger number of patients are needed to determine its place in the evaluation of cancer staging and treatment planning.
Collapse
Affiliation(s)
- Serap Gültekin
- Gazi Universitesi Tip Fakültesi, Radyoloji Anabilim Dali, 06510 Besevler-Ankara, Turkey.
| | | | | | | | | | | |
Collapse
|
10
|
Abstract
Recent advances in contrast material-enhanced ultrasonography (US) mainly include (a) development of low-acoustic-pressure (low-mechanical-index) harmonic software, capable of obtaining real-time images without disrupting contrast material microbubbles, and (b) commercialization of new contrast media ("second-generation" contrast media), capable of producing intense echo signals in this low-mechanical-index setting. With use of low-mechanical-index continuous-mode contrast-enhanced US, the circulatory kinetic models of various focal liver lesions can be displayed dynamically. Hepatic lesions usually have typical perfusion characteristics and enhancement patterns through the various phases of parenchymal enhancement, which helps characterize lesions and, in most cases, allows definitive diagnosis, even among lesions that exhibit very similar baseline appearances. Because of the use of harmonic technologies at low emission frequencies, there is some loss of spatial resolution and overall image quality, typically resulting in a grainy appearance. In addition, lesion depth affects the detectability of vascularity to some degree in that poor signal arises from deep-seated lesions. Moreover, liver attenuation (eg, in patients with steatosis or chronic liver disease) further reduces the sensitivity of contrast-enhanced US. Nevertheless, with its unique capacity to provide images in real time, low-mechanical-index contrast-enhanced US is the dynamic imaging modality of choice in the differential diagnosis of focal liver lesions.
Collapse
|
11
|
Tranquart F, Bleuzen A, Tchuenbou J. [Contrast ultrasound imaging in focal liver lesions: diagnostic value and guidelines]. ACTA ACUST UNITED AC 2005; 85:680-9. [PMID: 15238869 DOI: 10.1016/s0221-0363(04)97649-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The recent introduction of high quality scanners and contrast agents for ultrasound deeply modifies diagnosis strategy in focal liver lesions by using validated criteria. Non-linear imaging methods using low mechanical index (MI<0.2) and second generation contrast agents allow real-time continuous imaging with concomitant limitation in background tIssue signal and also in agent collapse for a high quality contrast imaging giving dramatic improvement in detection and characterization of lesions. Interpretation is based on the presence of contrast agent within the lesion or not (hyper-, hypo- or isosignal) and the delay after injection (arterial, portal or parenchymal or late phase) as previously used by non-ultrasound methods. This allows an easy differentiation of benign from malignant lesions. Moreover, this allows complete characterization in 85 to 95% of all focal liver lesions and 75% in hepatocellular carcinomas. Those results markedly improve ultrasound accuracy compared to conventional sonography and so put contrast-enhanced sonography among recommended non-invasive imaging methods for focal liver lesions with changes in diagnostic strategy according to the lesion type and actual place of US methods. It is recommended to use contrast ultrasound methods in cancer staging for an optimal detection of liver metastases as well as in characterization of lesions detected during conventional sonography with a consecutive decrease of cost-diagnosis ratio.
Collapse
Affiliation(s)
- F Tranquart
- CIT Ultrasons, CHU Bretonneau, 37044 Tours Cedex.
| | | | | |
Collapse
|
12
|
Eyding J, Krogias C, Wilkening W, Meves S, Ermert H, Postert T. Parameters of cerebral perfusion in phase-inversion harmonic imaging (PIHI) ultrasound examinations. ULTRASOUND IN MEDICINE & BIOLOGY 2003; 29:1379-1385. [PMID: 14597334 DOI: 10.1016/s0301-5629(03)01035-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The aim was to evaluate phase-inversion harmonic imaging (PIHI) with respect to brain perfusion imaging using a novel "bilateral approach" (depth of examination: 150 mm) and established unilateral approach (100 mm). After bolus injection of two contrast agents (CA, Optison and SonoVue), perfusion-related parameters (time-to-peak intensity, Itpk, peak intensity, Ipk, and peak width, Wpk) were extracted by fitting a model function to time-intensity curves for different regions-of-interest (ROI) in 14 volunteers. In 207 (92%) of 224 ipsilateral ROIs and in 165 (98%) of 168 contralateral ROIs (372 or 95% of 392 altogether), parameters could be derived. Itpk and Wpk of gray matter ROIs did not vary in or between both CA groups (18.1-21.9 s and 7.9-14.2 s). ROIs within arteries showed significantly shorter Itpk (16.1-16.7 s) and longer Wpk (12.8-28.3 s). Level of significance was 0.05 (two-sided). Newer CAs are usable for nonlinear imaging over a wider range of acoustic intensities, so that sensitivity of PIHI is sufficient to image the brain bilaterally. This approach proves to be reliable in patients with adequate bone windows. For acute stroke patients, this implies that both hemispheres can be compared in one instead of two examinations, reducing time of examination by 50%. Furthermore, evaluation of regions close to the probe becomes possible. Thus, the "bilateral approach" should be considered as a new standard approach of acute ultrasonic perfusion imaging.
Collapse
Affiliation(s)
- Jens Eyding
- Department of Neurology, St. Josef Hospital, Ruhr-University Bochum, Ruhr Center of Competence for Medical Engineering, Bochum, Germany.
| | | | | | | | | | | |
Collapse
|