1
|
Bhatnagar G, Mallett S, Beable R, Greenhalgh R, Ilangovan R, Lambie H, Mainta E, Patel U, Porté F, Sidhu H, Gupta A, Higginson A, Slater A, Tolan D, Zealley I, Halligan S, Taylor SA. Influence of diffusion weighted imaging and contrast enhanced T1 sequences on the diagnostic accuracy of magnetic resonance enterography for Crohn's disease. Eur J Radiol 2024; 175:111454. [PMID: 38598964 DOI: 10.1016/j.ejrad.2024.111454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 03/05/2024] [Accepted: 04/04/2024] [Indexed: 04/12/2024]
Abstract
OBJECTIVES To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease. METHODS Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard. RESULTS 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients. CONCLUSION There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.
Collapse
Affiliation(s)
- Gauraang Bhatnagar
- Centre for Medical Imaging, University College London, Charles Bell House, 43-45 Foley Street W1W 7TS, UK
| | - Sue Mallett
- Centre for Medical Imaging, University College London, Charles Bell House, 43-45 Foley Street W1W 7TS, UK
| | - Richard Beable
- Department of Radiology, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Rebecca Greenhalgh
- Intestinal Imaging Centre, St Mark's Hospital, LNWUH NHS Trust, Harrow, UK
| | | | - Hannah Lambie
- Department of Radiology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Beckett Street, Leeds LS9 7TF, UK
| | - Evgenia Mainta
- Intestinal Imaging Centre, St Mark's Hospital, LNWUH NHS Trust, Harrow, UK
| | - Uday Patel
- Intestinal Imaging Centre, St Mark's Hospital, LNWUH NHS Trust, Harrow, UK
| | - François Porté
- Intestinal Imaging Centre, St Mark's Hospital, LNWUH NHS Trust, Harrow, UK
| | - Harbir Sidhu
- Centre for Medical Imaging, University College London, Charles Bell House, 43-45 Foley Street W1W 7TS, UK
| | - Arun Gupta
- Intestinal Imaging Centre, St Mark's Hospital, LNWUH NHS Trust, Harrow, UK; Department of Surgery and Cancer, Imperial College London, Exhibition Rd, South Kensington, London SW7 2BX, UK
| | - Anthony Higginson
- Department of Radiology, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Andrew Slater
- Department of Radiology, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Damian Tolan
- Department of Radiology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Beckett Street, Leeds LS9 7TF, UK
| | - Ian Zealley
- Department of Radiology, Ninewells Hospital, Dundee DD1 9SY, UK
| | - Steve Halligan
- Centre for Medical Imaging, University College London, Charles Bell House, 43-45 Foley Street W1W 7TS, UK
| | - Stuart A Taylor
- Centre for Medical Imaging, University College London, Charles Bell House, 43-45 Foley Street W1W 7TS, UK.
| |
Collapse
|
2
|
Dillman JR, Anupindi SA, Dane B. Proposal of an Abbreviated Noncontrast MR Enterography Protocol for Patients With Crohn Disease. AJR Am J Roentgenol 2024; 222:e2330422. [PMID: 38054957 DOI: 10.2214/ajr.23.30422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
MR enterography (MRE) protocols used in patients with Crohn disease are burdened by long acquisition time, high cost, and suboptimal patient experience. For several indications, highly diagnostic MRE can be performed in five or fewer sequences, without IV contrast material or antiperistaltic medication and with an examination room time of less than 12 minutes. As such, MRE could be more patient friendly, more frequently performed, and require fewer health care resources.
Collapse
Affiliation(s)
- Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati, 3333 Burnet Ave, Cincinnati, OH 45229
| | - Sudha A Anupindi
- Department of Radiology, Children's Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
| | - Bari Dane
- Department of Radiology, NYU Langone Health, New York, NY
| |
Collapse
|
3
|
Jannatdoust P, Valizadeh P, Razaghi M, Rouzbahani M, Abbasi A, Arian A. Role of abbreviated non-contrast-enhanced MR-enterography in the evaluation of Crohn's disease activity and complications as an alternative for full protocol contrast-enhanced study: A systematic review and meta-analysis. RESEARCH IN DIAGNOSTIC AND INTERVENTIONAL IMAGING 2023; 6:100030. [PMID: 39077544 PMCID: PMC11265495 DOI: 10.1016/j.redii.2023.100030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 04/24/2023] [Indexed: 07/31/2024]
Abstract
Background Crohn's disease (CD) is a chronic disorder that often starts at a young age and involves periods of remission and relapse. Prompt diagnosis of relapses through screening is crucial due to the potential morbid complications of untreated active inflammation. Magnetic resonance enterography (MRE) is a noninvasive technique to screen for active inflammation. The standard protocol involves intravenous injection of contrast agents with potential side effects. Some abbreviated non-contrast-enhanced MRE protocols are proposed as alternatives for conventional MRE to identify active inflammation. Currently, there is controversy regarding the applicability and accuracy of these protocols. This study aims to describe and compare these protocols and evaluate their accuracy in detecting active inflammation and CD complications. Methods Results from a systematic search of three databases in August 2022 were queried and screened by abstract and full text. Eligible studies were qualitatively and quantitatively analyzed by diagnostic test accuracy meta-analysis. Results 59 studies entered the systematic review, and 37 were eligible for meta-analysis. Diffusion-weighted imaging (DWI) and fast T2-weighted (T2w) sequences were most frequently used in abbreviated protocols and showed non-inferior accuracy compared to the full protocol in detecting active inflammation. ADC and qualitative DWI had pooled sensitivity of 90% (CI: 82-95%) and 89% (CI:82-93%) and pooled specificity of 94% (CI: 88-97%) and 89% (CI: 79-94%), respectively for detecting active inflammation. Moreover, T2w and combined T2w+DWI sequences had pooled sensitivity of 80% (CI: 64-90%) and 76% (CI: 61-86%) and pooled specificity of 90% (CI: 80-95%) and 87% (CI: 74 - 94%), respectively. Unenhanced protocols show relatively poor diagnostic accuracy in detecting penetrating complications of CD. Magnetization transfer imaging (MTI) has demonstrated excellent accuracy in detecting fibrosis. High heterogeneity was observed in all subgroups, and accuracy was reported to be highly operator dependent in most studies. Conclusion An abbreviated protocol consisting of DWI and fast T2w imaging can potentially replace the full protocol MRE. Full protocol MRE will still have its role in identifying penetrating complications. MTI should be indicated in case of suspected fibrostenotic disease.
Collapse
Affiliation(s)
- Payam Jannatdoust
- School of Medicine, Tehran University of Medical Science, Tehran, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Parya Valizadeh
- School of Medicine, Tehran University of Medical Science, Tehran, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahshad Razaghi
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Maedeh Rouzbahani
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Amirbahador Abbasi
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Arvin Arian
- School of Medicine, Tehran University of Medical Science, Tehran, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Blanco Velasco G, Ramos-García J, García-Contreras LF, Solórzano-Pineda OM, Martínez-Camacho C, Murcio-Pérez E, Hernández-Mondragón ÓV. Predictive value of patency capsule and magnetic resonance enterography for capsule endoscopy retention in patients with established Crohn's disease. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2023; 115:110-114. [PMID: 35656921 DOI: 10.17235/reed.2022.8848/2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
INTRODUCTION retention is the most common adverse event of the small bowel capsule endoscopy procedure. Patency capsule (Medtronic, Dublin, Ireland) and magnetic resonance enterography are two diagnostic methods that can prevent small bowel capsule endoscopy retention. The aim of this study was to evaluate the predictive value of these two diagnostic methods. MATERIAL AND METHODS a prospective, comparative and observational study was performed in patients with established Crohn's disease. All patients had undergone magnetic resonance enterography and patency capsule procedures. If the patency capsule was not retained, the patient underwent a small bowel capsule endoscopy; otherwise, double balloon enteroscopy was performed to locate the stenosis. Magnetic resonance enterography predictive criteria for retention were analyzed in all cases. Sensitivity, specificity, positive predictive value and negative predictive value of the patency capsule and magnetic resonance enterography compared to small bowel capsule endoscopy or double balloon enteroscopy were calculated. RESULTS forty patients were included (24 female, 55 ± 13 years old). Retention criteria with capsule endoscopy or double balloon enteroscopy were found in six patients, agreeing in five cases with patency capsule and in three cases with magnetic resonance enterography. Sensitivity, specificity, positive predictive value, negative predictive value and Kappa coefficient for predicting retention with the patency capsule were 83 %, 100 %, 100 % and 97 %, respectively, and 50 %, 91 %, 50 % and 91 %, respectively, with magnetic resonance enterography. CONCLUSIONS patency capsule has a higher sensitivity and positive predictive value than magnetic resonance enterography for preventing small bowel capsule endoscopy retention in Crohn's disease patients.
Collapse
|
5
|
Mezrich JL, Weinreb JC. Financial and medicolegal implications of focused/fast abdominopelvic MRI exams. Abdom Radiol (NY) 2022; 47:471-474. [PMID: 34713311 DOI: 10.1007/s00261-021-03328-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 09/28/2021] [Accepted: 10/18/2021] [Indexed: 02/05/2023]
Abstract
PURPOSE Abbreviated MRI offers significant advantages in terms of MRI throughput, patient tolerance and expediency, and is being utilized for a variety of abdominopelvic imaging applications. However questions abound with respect to financial and medicolegal treatment of these relatively new protocols. METHODS A review of the relevant literature was performed. RESULTS There is no Current Procedural Terminology code for a "limited" MRI study, but it may not be appropriate to bill an abbreviated study the same as a more comprehensive study. With respect to medicolegal concerns, the risk of liability when missing or misinterpreting medically significant findings due to use of an abbreviated scan will turn on whether abbreviated MRI has become the standard of care. CONCLUSION In light of these ambiguities, it would behoove abdominopelvic imagers to advocate for their professional and subspecialty organizations to issue practice parameters/guidelines with respect to the utilization of abbreviated MRI protocols, and for the subspecialty to bill these abbreviated scans at objectively reasonable rates.
Collapse
Affiliation(s)
- Jonathan L Mezrich
- Department of Diagnostic Radiology and Biomedical Imaging, Yale School of Medicine, 333 Cedar Street, TE2, New Haven, CT, 06520, USA.
| | - Jeffrey C Weinreb
- Department of Diagnostic Radiology and Biomedical Imaging, Yale School of Medicine, 333 Cedar Street, TE2, New Haven, CT, 06520, USA
| |
Collapse
|
6
|
Basta Nikolic M, Spasic A, Hadnadjev Simonji D, Stojanović S, Nikolic O, Nikolic D. Imaging of acute pelvic pain. Br J Radiol 2021; 94:20210281. [PMID: 34491817 PMCID: PMC8553212 DOI: 10.1259/bjr.20210281] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 07/04/2021] [Accepted: 08/16/2021] [Indexed: 12/11/2022] Open
Abstract
Acute pelvic pain (APP) requires urgent medical evaluation and treatment. Differential diagnosis of APP is broad, including a variety of gynecologic and non-gynecologic/ urinary, gastrointestinal, vascular and other entities. Close anatomical and physiological relations of pelvic structures, together with similar clinical presentation of different disorders and overlapping of symptoms, especially in the emergency background, make the proper diagnosis of APP challenging. Imaging plays a crucial role in the fast and precise diagnosis of APP. Ultrasonography is the first-line imaging modality, often accompanied by CT, while MRI is utilized in specific cases, using short, tailored protocols. Recognizing the cause of APP in females is a challenging task, due to the wide spectrum of possible origin and overlap of their imaging features. Therefore, the radiologist has to be familiar with the possible causes of APP, and, relying on clinical presentation, together with laboratory findings, choose the best imaging strategy in order to establish a fast and accurate diagnosis.
Collapse
Affiliation(s)
- Marijana Basta Nikolic
- Centre of Radiology, Clinical Centre of Vojvodina, Faculty of Medicine, University of Novi Sad, Vojvodina, Serbia
| | - Aleksandar Spasic
- Centre of Radiology, Clinical Centre of Vojvodina, Faculty of Medicine, University of Novi Sad, Vojvodina, Serbia
| | - Darka Hadnadjev Simonji
- Centre of Radiology, Clinical Centre of Vojvodina, Faculty of Medicine, University of Novi Sad, Vojvodina, Serbia
| | - Sanja Stojanović
- Centre of Radiology, Clinical Centre of Vojvodina, Faculty of Medicine, University of Novi Sad, Vojvodina, Serbia
| | - Olivera Nikolic
- Centre of Radiology, Clinical Centre of Vojvodina, Faculty of Medicine, University of Novi Sad, Vojvodina, Serbia
| | - Dragan Nikolic
- Clinic for Vascular and Endovascular Surgery, Clinical Centre of Vojvodina, Faculty of Medicine, University of Novi Sad, Vojvodina, Serbia
| |
Collapse
|
7
|
Bufman H, Eliakim R, Tau N, Amitai MM. Magnetic resonance enterography in Crohn's disease patients: current state of the art and future perspectives. Expert Rev Med Devices 2021; 18:657-667. [PMID: 34109891 DOI: 10.1080/17434440.2021.1939682] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
INTRODUCTION Crohn's disease (CD) is a major concern due to relatively high incidence and major complications like stricture or fistulas, often requiring surgical treatment. In recent years, magnetic resonance enterography (MRE) became a popular method of diagnosis and disease surveillance. The purpose of this review is to summarize and discuss the major and most recent advances in various aspects of MRE usage in diagnosong Crohn's disease, and to discuss advances in technique, disease activity monitoring and response to treatment. METHODS A literature search was performed and relevant publications were included, with emphasis on articles from the past decade. AREAS COVERED In this review we have presented articles with major advances in the field of MRE of CD patients such as proper sequence selection, recent advances in scoring of disease activity, differentiation between inflammation and fibrosis, response to treatment and technological advances such as the use of AI. EXPERT OPINION The main goal in improving MRE performance will be sequence selection aimed at differenting between inflammation and stricture while shortening the study length adjusted to patient compliance, and developing a standardized scoring system for MRE reporting assisted by artificial intelligence.
Collapse
Affiliation(s)
- Hila Bufman
- Department of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, Israel.,Sackler School of Medicine, Tel Aviv University, Tel-Aviv, Israel
| | - Rami Eliakim
- Sackler School of Medicine, Tel Aviv University, Tel-Aviv, Israel.,Department of Gastroenterology, Sheba Medical Center, Tel Hashomer, Israel
| | - Noam Tau
- Department of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, Israel.,Sackler School of Medicine, Tel Aviv University, Tel-Aviv, Israel
| | - Michal Marianne Amitai
- Department of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, Israel.,Sackler School of Medicine, Tel Aviv University, Tel-Aviv, Israel
| |
Collapse
|
8
|
Dane B, Bearison C, Kim S. Frequency and significance of incidental liver lesions on MR enterography in adult patients. Clin Imaging 2021; 80:6-10. [PMID: 34217035 DOI: 10.1016/j.clinimag.2021.06.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/24/2021] [Accepted: 06/07/2021] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the frequency and significance of incidental liver lesions identified on MR enterography (MRE) examinations to determine if dedicated sequences for liver evaluation are necessary in the routine MRE protocol. METHODS A retrospective departmental database search identified 353 adult (212 women and 141 men; mean [±SD] age, 41.4 [17.0] years; range 18.1-91.9 years) MRE examinations performed in 2017. Radiology reports were reviewed for the presence and characterization of liver lesions, follow-up recommendation, and known malignancy. Follow-up cross-sectional imaging reports were reviewed for liver lesion stability. A senior abdominal radiologist with expertise in liver imaging categorized liver lesions as benign, indeterminate, or malignant and re-characterized indeterminate lesions using follow-up imaging as benign or malignant. RESULTS Seventy-nine MRE (22.4%) described liver lesions and follow-up imaging was recommended in 4/79 (5.1%). Seventy-six liver lesions (96.2%) were characterized as benign (cysts/hemangiomas) on routine interpretation and expert review. One of these was recommended for follow-up imaging on initial report, which was characterized as hemangioma by expert review. The remaining 3 lesions (3.8%) were characterized as indeterminate both by initial report and expert radiologist review but re-characterized as benign after reviewing follow-up examinations. CONCLUSION All incidental liver lesions identified on MRE in our cohort were benign. Therefore, additional sequences evaluating the liver are unnecessary for routine MRE.
Collapse
Affiliation(s)
- Bari Dane
- Department of Radiology, NYU Langone Medical Center, New York, NY 10016, United States of America.
| | - Craig Bearison
- Department of Radiology, NYU Langone Medical Center, New York, NY 10016, United States of America.
| | - Sooah Kim
- Department of Radiology, NYU Langone Medical Center, New York, NY 10016, United States of America.
| |
Collapse
|
9
|
Editor's Notebook: February 2021. AJR Am J Roentgenol 2021; 216:273-274. [PMID: 33476219 DOI: 10.2214/ajr.20.25053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|