1
|
Oh S, Kim HJ, Kim HJ, Antonson SA, Kim SY. Influence of irradiation distance on the mechanical performances of resin composites polymerized with high-irradiance light curing units. Biomater Res 2022; 26:18. [PMID: 35596228 PMCID: PMC9123695 DOI: 10.1186/s40824-022-00267-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 05/10/2022] [Indexed: 11/10/2022] Open
Abstract
Background The aim of this study was to evaluate the influence of increased irradiation distance on the flexural strength (FS), dentin micro-shear bond strength (μSBS), and the degree of conversion (DC) of bulk-fill flowable, conventional flowable, and packable resin composites. Methods The resin composites tested were Surefil® SDR™ (SDR), Filtek Z350 XT Flowable Restorative A2 shade (Z3F), and Filtek Z350 XT Universal Restorative A2 shade (Z3P). Specimens were cured at four irradiation distances (0, 2, 4, and 8 mm) with an Elipar DeepCure-S LED curing light for 20 s. FS tests were performed (n = 15) using bar-shaped specimens (8 mm × 2 mm × 2 mm) of the resin composites. μSBS tests were performed on the occlusal surfaces of extracted third molars from humans that were ground to expose dentin (n = 15). DC was measured by using Raman spectroscopy on the top and bottom surfaces of disk specimens (2-mm thick) (n = 3). To further investigate whether extended irradiation times could compensate for reduced irradiance, additional Z3P specimens were prepared, which were light-cured at 8-mm distances for 40 and 60 s and subjected to FS tests, μSBS tests, and Raman spectroscopy. Both two-way and one-way ANOVA were used for statistical analyses. Results Both FS and DC of Z3P specimens cured at an 8-mm distance were significantly lower than those cured at shorter distances (p < 0.05), whereas the FS and DC of the Z3F and SDR specimens were not significantly influenced by increasing distances. The μSBSs of the three types of resin composites reduced with increasing irradiation distances. The FS, μSBS, and DC of the Z3P specimen light-cured at 8 mm for 40 s were comparable to those of the Z3P specimen cured at 0 mm for 20 s. Conclusions Increasing the irradiation distance to 8 mm can have a deleterious influence on mechanical performances, including the FS, DC, and dentin μSBS, of the resin composites polymerized with high-irradiance light curing units.
Collapse
Affiliation(s)
- Soram Oh
- Department of Conservative Dentistry, School of Dentistry, Kyung Hee University, 1 Hoe-gi-dong, Dongdaemoon-gu, Seoul, 02447, Korea
| | - Hyun Ju Kim
- Department of Periodontics, Seoul National University Dental Hospital, 101 Daehakno, Jongno-gu, Seoul, 03080, Korea
| | - Hyun-Jung Kim
- Department of Conservative Dentistry, Kyung Hee University Dental Hospital, 1 Hoe-gi-dong, Dongdaemoon-gu, Seoul, 02447, Korea
| | - Sibel A Antonson
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, 3200 S. University Dr., Fort Lauderdale, FL, 33328, USA
| | - Sun-Young Kim
- Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehakno, Jongno-gu, Seoul, 03080, Korea.
| |
Collapse
|
2
|
Altaie A, Hadis MA, Wilson V, German MJ, Nattress BR, Wood D, Palin WM. An Evaluation of the Efficacy of LED Light Curing Units in Primary and Secondary Dental Settings in the United Kingdom. Oper Dent 2021; 46:271-282. [PMID: 34370026 DOI: 10.2341/20-092-lit] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This study aimed to evaluate the irradiance and the quality of LED light curing units (LCUs) in primary and secondary clinics in the UK and to assess the effect of damage, contamination, use of protective sleeves, and distance of light tips to target on the irradiance and performance of LCUs. METHODS The irradiance levels (mW/cm2) of 26 LED LCUs from general dental practices and 207 LED LCUs from two dental hospitals were measured using a digital radiometer (Blue Phase II, Ivoclar, Vivadent, Amherst, NY). Ten LED light guide tips (Satelec Mini, Acteon, Merignac, France) were selected to evaluate the effect of chipping, contamination (tip debris), and use of protective sleeves and tips to sensor distance on irradiance (mW/cm2) using a MARC Resin Calibrator (Blue Light Analytics, Halifax, Canada). Homogeneity of the light output was evaluated using a laser beam profiler (SP620; Ophir-Spiricon, North Longan, UT, USA). Statistical analysis was conducted using a one-way analysis of variance (ANOVA) with post hoc Tukey test (α=0.05) and linear regression with stepwise correlation tests. RESULTS Thirty-three percent of the LCUs delivered irradiance output less than 500 mW/cm2. The condition of the light curing tips was poor, with 16% contaminated with resin debris, 26% damaged, and 10% both contaminated and damaged. The irradiance output was significantly reduced in contaminated (62%) and chipped (50%) light curing tips and when using protective sleeves (24%) (p<0.05). Irradiance was also reduced when increasing the distance with 25% and 34% reduction at 7 mm and 10 mm, respectively (p<0.05). CONCLUSION There remains a lack of awareness of the need for regular monitoring and maintenance of dental LCUs. Damaged and contaminated light curing tips, use of protective sleeves, and increasing the distance from the restoration significantly reduced the irradiance output and the performance of the LCUs.
Collapse
|
3
|
Al-Zain AO, Marghalani HY. Influence of Light-curing Distances on Microflexural Strength of Two Resin-based Composites. Oper Dent 2020; 45:297-305. [DOI: 10.2341/19-001-l] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
Our objective was to investigate the influence of different curing distances on microflexural strength and the microflexural modulus of two resin-based composites.
Methods:
Two nanohybrid composites were used; Filtek Z250 (Z250) and Tetric EvoCeram (TEC). Rectangular specimens were prepared (2-mm wide × 1-mm deep × 6-mm long) light cured according to the manufacturer's instructions at 0-mm, 2-mm, and 8-mm distances (n=10) and were stored wet at 37°C for 24 hours. A microflexural strength test was performed using a universal testing machine at a crosshead speed of 1 mm/min. The microflexural strength and microflexural modulus data were analyzed using a two-way analysis of variance followed by a Tukey multiple comparison post hoc test (α=0.05).
Results:
The TEC composite had a significantly higher microflexural strength at an 8-mm distance compared with the 0-mm distance. The Z250 composite expressed significantly higher microflexural strength, at 2-mm and 8-mm compared with the 0-mm distance. TEC showed a significantly higher microflexural modulus at an 8-mm distance compared with the 0-mm and 2-mm distances. Z250 also exhibited a significantly higher microflexural modulus at the 2-mm distance, compared with the 8-mm distance. In total, Z250 presented a significantly higher microflexural strength and modulus compared with TEC.
Conclusion:
Curing the explored composites at 2-mm or 8-mm distances from the specimen surface did not have a significant influence on microflexural strength but did significantly affect the microflexural modulus.
Collapse
Affiliation(s)
- AO Al-Zain
- Afnan O Al-Zain, BDS, MSD, PhD, Diploma of Professional Development in Teaching and Learning, Operative and Esthetic Dentistry Division, Restorative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - HY Marghalani
- Hanadi Y Marghalani, BDS, MSc, PhD, DRBBA-Research Group, Operative and Esthetic Dentistry Division, Restorative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
4
|
Lima RBW, Murillo-Gómez F, Sartori CG, De Góes MF. Effect of light absence or attenuation on biaxial flexural strength of dual-polymerized resin cements after short- and long-term storage. J ESTHET RESTOR DENT 2018; 31:80-87. [PMID: 30394656 DOI: 10.1111/jerd.12427] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 07/16/2018] [Accepted: 09/05/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate whether biaxial flexural strength (BFS) of dual resin cements is affected by light absence or attenuation, storage time, or cements' chemical nature. MATERIALS AND METHODS One hundred and twenty disk-shaped specimens were made from each cement (non-self-adhesive cement and self-adhesive cement) using Teflon molds on a controlled temperature surface (35°C). Specimens were polymerized as follows (N = 30): self-cured, directly light-cured, light-cured at a distance of 6 mm between the light tip and the specimen, and through a 6-mm thick composite resin barrier (indirectly light-cured). Each group was divided (N = 10) for storage purposes (15 minutes, 24 hours, and 6 months). Specimens were placed into a biaxial-flexure jig and a vertical load was applied until failure. The BFS values were subjected to generalized linear models statistical analysis and Weibull distributions (α = 0.05). RESULTS After 15 minutes aging, neither material achieved enough polymerization to perform the BFS test when polymerized using the self-curing mode. The self-adhesive product demonstrated much lower variation in strength with storage time than did the non-self-curing cement. CONCLUSIONS Attenuated/light-curing reduced BFS values only for 15-minutes storage period for both materials. Flexural strength of the self-adhesive cement was less affected by light absence/attenuation and storage time. CLINICAL SIGNIFICANCE Biaxial flexural strength of a self-adhesive resin cement is less sensitive to variation in light application and storage time than is a non-self-adhesive cement.
Collapse
Affiliation(s)
- Renally B W Lima
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil
| | - Fabián Murillo-Gómez
- Department of Restorative Dentistry, School of Dentistry, University of Costa Rica, San José, Costa Rica
| | - Cristiana G Sartori
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil
| | - Mário F De Góes
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil
| |
Collapse
|
5
|
Photo-calorimetry method optimization for the study of light-initiated radical polymerization of dental resins. POLYMER 2018. [DOI: 10.1016/j.polymer.2017.12.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
6
|
Karaman E, Yazici AR, Aksoy B, Karabulut E, Ozgunaltay G, Dayangac B. Effect of operator variability on microleakage with different adhesive systems. Eur J Dent 2014; 7:S060-S065. [PMID: 24966730 PMCID: PMC4054081 DOI: 10.4103/1305-7456.119075] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Objective: The objective of this study was to evaluate the effect of operator variability on microleakage with different adhesive systems. Materials and Methods: A total of 180 standardized Class V cavities were prepared on facial and lingual of 90 extracted human premolar teeth and randomly assigned to five groups according to the adhesive systems used (n = 36): Prime and Bond NT (PB), Single Bond (SB), Futura Bond NR, Xeno III (XE) and Adper Prompt-L-Pop (LP). The adhesive groups were then further subdivided into three operator groups according to level of clinical experience (n = 12): An undergraduate student, a research assistant and a faculty member. All cavities were restored with same composite resin. The restored teeth were thermocycled (500 cycles, 5-55°C) then immersed in 0.5% basic fuchsin and measured for leakage under a stereomicroscope. Statistical analyses were performed with the Kruskal-Wallis and Mann-Whitney U tests. Results: Significant inter-operator variation was found in the enamel margins in the XE group with significantly higher microleakage when used by the undergraduate student (P < 0.05). Although no significant differences in microleakage were found between adhesive systems for the research assistant and faculty member (P > 0.05), significant differences were observed between PB and LP, PB and XE, SB and LP and SB and XE in the enamel margins for the undergraduate student (P < 0.05). Conclusion: Microleakage of adhesive systems is more dependent on interactions between the operator and adhesive material than on the choice of adhesive material.
Collapse
Affiliation(s)
- Emel Karaman
- Department of Restorative Dentistry, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkiye
| | - A Ruya Yazici
- Department of Restorative Dentistry, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye
| | - Burak Aksoy
- Department of Pediatric Dentistry, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye
| | - Erdem Karabulut
- Department of Biostatistics, Faculty of Medicine, Hacettepe University, Ankara, Turkiye
| | - Gul Ozgunaltay
- Department of Restorative Dentistry, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye
| | - Berrin Dayangac
- Department of Restorative Dentistry, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye
| |
Collapse
|
7
|
FT-Raman spectroscopy: a useful tool in measuring resin composite degradation? Future Med Chem 2013; 5:1599-601. [DOI: 10.4155/fmc.13.119] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
8
|
Leprince JG, Palin WM, Hadis MA, Devaux J, Leloup G. Progress in dimethacrylate-based dental composite technology and curing efficiency. Dent Mater 2013. [PMID: 23199807 DOI: 10.1016/j.dental.2012.11.005] [Citation(s) in RCA: 303] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Julian G Leprince
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium.
| | | | | | | | | |
Collapse
|
9
|
Gomes M, DeVito-Moraes A, Francci C, Moraes R, Pereira T, Froes-Salgado N, Yamazaki L, Silva L, Zezell D. Temperature increase at the light guide tip of 15 contemporary LED units and thermal variation at the pulpal floor of cavities: an infrared thermographic analysis. Oper Dent 2012; 38:324-33. [PMID: 23092145 DOI: 10.2341/12-060-l] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In this study, a comprehensive investigation on the temperature increase at the light guide tip of several commercial light-emitting diode (LED) light-curing units (LCUs) and the associated thermal variation (ΔT) at the pulpal floor of dental cavities was carried out. In total, 15 LEDs from all generations were investigated, testing a quartz-tungsten-halogen (QTH) unit as a reference. The irradiance level was measured with a power meter, and spectral distribution was analyzed using a spectrometer. Temperature increase at the tip was measured with a type-K thermocouple connected to a thermometer, while ΔT at the pulpal floor was measured by an infrared photodetector in class V cavities, with a 1-mm-thick dentin pulpal floor. The relationship among measured irradiance, ΔT at the tip, and ΔT at the pulpal floor was investigated using regression analyses. Large discrepancies between the expected and measured irradiances were detected for some LCUs. Most of the LCUs showed an emission spectrum narrower than the QTH unit, with emission peaks usually between 450 and 470 nm. The temperature increase at the tip followed a logarithmic growth for LCUs with irradiance ≥1000 mW/cm(2), with ΔT at the tip following the measured irradiance linearly (R(2)=0.67). Linear temperature increase at the pulpal floor over the 40-second exposure time was observed for several LCUs, with linear association between ΔT at the pulpal floor and measured irradiance (R(2)=0.39) or ΔT at the tip (R(2)=0.28). In conclusion, contemporary LED units show varied irradiance levels that affect the temperature increase at the light guide tip and, as a consequence, the thermal variation at the pulpal floor of dental cavities.
Collapse
Affiliation(s)
- M Gomes
- School of Dentistry, University of São Paulo, Dental Materials, São Paulo, Brazil
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Feitosa VP, Fugolin APP, Correr AB, Correr-Sobrinho L, Consani S, Watson TF, Sinhoreti MAC, Sauro S. Effects of different photo-polymerization protocols on resin-dentine μTBS, mechanical properties and cross-link density of a nano-filled resin composite. J Dent 2012; 40:802-9. [PMID: 22687576 DOI: 10.1016/j.jdent.2012.05.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2012] [Revised: 05/25/2012] [Accepted: 05/28/2012] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVES To evaluate the effects of four different light-curing protocols on the microtensile bond strength (μTBS), ultimate tensile strength (UTS), Knoop micro-hardness (KH) and cross-link density (CLD) of a nano-filled resin composite. METHODS Filtek Supreme XT (3M-ESPE) was used for the entire experiments following four light-curing approaches: ST, standard irradiance; HI, high irradiance; PD, pulse delay; SS, soft start. The specimens were submitted to different storage periods (24h or 6 months), cut into match-sticks and subsequently submitted to μTBS testing. Hourglass specimens were also prepared for UTS and KH. Cylindrical specimens were prepared for the CLD evaluation after absolute ethanol challenge. The results were statistically analyzed with a two-way ANOVA and Tukey's test (α=0.05). RESULTS For UTS and KH, continuous irradiance (PD and SS) induced statistically higher results (p<0.05) both after 24h and 6 months of water storage compared to ST and HI groups. However, a drop in UTS and KH was obtained after 6 months in all groups. The μTBS was not affected by the different light-curing approaches and, no statistical differences (p>0.05) were observed between 24h and 6 months storage. The CLD evaluation showed a statistical drop in KH after 24h of ethanol storage for PD and SS (step-curing protocols) compared to those attained in continuous mode (ST and HI). CONCLUSION The soft-start mode may improve the UTS and KH of nano-filled resin composites without compromising the resin-dentine μTBS. However, both the step-curing protocols may reduce the cross-link density of the composite polymeric network. CLINICAL SIGNIFICANCE High irradiances photo-polymerization may be adequate for direct aesthetic restorations such as veneers and onlays. Meanwhile, the soft start protocol would seem more appropriate for the photo-polymerization of high c-factors class I and II restorations.
Collapse
Affiliation(s)
- Victor Pinheiro Feitosa
- Department of Restorative Dentistry, Division of Dental Materials, Piracicaba Dental School, State University of Campinas, UNICAMP, Piracicaba, SP, Brazil.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Gaglianone LA, Lima AF, Araújo LSND, Cavalcanti AN, Marchi GM. Influence of different shades and LED irradiance on the degree of conversion of composite resins. Braz Oral Res 2012; 26:165-9. [DOI: 10.1590/s1806-83242012005000002] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2011] [Accepted: 01/04/2012] [Indexed: 11/21/2022] Open
|
12
|
Dennison JB, Sarrett DC. Prediction and diagnosis of clinical outcomes affecting restoration margins. J Oral Rehabil 2011; 39:301-18. [PMID: 22066463 DOI: 10.1111/j.1365-2842.2011.02267.x] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The longevity of dental restorations is largely dependent on the continuity at the interface between the restorative material and adjacent tooth structure (the restoration margin). Clinical decisions on restoration repair or replacement are usually based upon the weakest point along that margin interface. Physical properties of a restorative material, such as polymerisation shrinkage, water sorption, solubility, elastic modulus and shear strength, all have an effect on stress distribution and can significantly affect margin integrity. This review will focus on two aspects of margin deterioration in the oral environment: the in vitro testing of margin seal using emersion techniques to simulate the oral environment and to predict clinical margin failure and the relationship between clinically observable microleakage and secondary caries. The many variables associated with in vitro testing of marginal leakage and the interpretation of the data are presented in detail. The most recent studies of marginal leakage mirror earlier methodology and lack validity and reliability. The lack of standardised testing procedures makes it impossible to compare studies or to predict the clinical performance of adhesive materials. Continual repeated in vitro studies contribute little to the science in this area. Clinical evidence is cited to refute earlier conclusions that clinical microleakage (penetrating margin discoloration) leads to caries development and is an indication for restoration replacement. Margin defects, without visible evidence of soft dentin on the wall or base of the defect, should be monitored, repaired or resealed, in lieu of total restoration replacement.
Collapse
Affiliation(s)
- J B Dennison
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, MI 48109, USA.
| | | |
Collapse
|
13
|
Laegreid T, Gjerdet NR, Vult von Steyern P, Johansson AK. Class II composite restorations: importance of cervical enamel in vitro. Oper Dent 2011; 36:187-95. [PMID: 21777100 DOI: 10.2341/10-126-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This study evaluated the importance of enamel at the cervical margin for support and retention of a class II composite restoration in relation to fracture strength, fracture mode, and leakage. METHODS Sixty-five newly extracted teeth were randomly divided into five groups. Within each group, standardized class II preparations were made at the mesial surface of the tooth with four different preparation designs. Group D (n=15) had the cervical margin placed below the cemento-enamel junction (the dentin group), and in the other three groups (the enamel groups: E1, E2, and E3), the cervical margin was within the enamel (n=15 each). Group E3 had restorations with cuspal coverage, while groups E1 and E2 differed in vertical dimension. Intact teeth without preparation or restoration were tested as controls (n=5). The area of the horizontal part of enamel at the cervical margin of the preparation (available cervical enamel) was calculated. The teeth were restored with a nanofilled composite material and an etch-and-rinse adhesive system. The teeth were subjected to artificial aging consisting of thermocycling and mechanical cyclical loading. The restorations were subsequently loaded until fracture. The teeth were examined microscopically to assess fracture mode and leakage at the interface between the restoration and the tooth substance. RESULTS The fracture strength in group D (without cervical enamel) and E3 (with cuspal coverage and cervical enamel) was lower (p<0.01) than in the other two groups (with cervical enamel). There was a correlation between the area of available cervical enamel and fracture strength (p<0.01). The median fracture strength for the control teeth was not significantly different from groups E1 and E2. Group D exhibited a predominance of adhesive fractures, while the other groups revealed more cohesive fractures. CONCLUSION The results from this study indicate that available cervical enamel has an impact on the performance of class II composite restorations.
Collapse
Affiliation(s)
- Torgils Laegreid
- University of Bergen, Department of Clinical Dentistry – Cariology, Bergen, Norway.
| | | | | | | |
Collapse
|
14
|
Souza-Junior EJ, de Souza-Régis MR, Alonso RCB, de Freitas AP, Sinhoreti MAC, Cunha LG. Effect of the curing method and composite volume on marginal and internal adaptation of composite restoratives. Oper Dent 2011; 36:231-8. [PMID: 21702671 DOI: 10.2341/10-107-l] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of the present study was to evaluate the influence of curing methods and composite volumes on the marginal and internal adaptation of composite restoratives. Two cavities with different volumes (Lower volume: 12.6 mm(3); Higher volume: 24.5 mm(3)) were prepared on the buccal surface of 60 bovine teeth and restored using Filtek Z250 in bulk filling. For each cavity, specimens were randomly assigned into three groups according to the curing method (n=10): 1) continuous light (CL: 27 seconds at 600 mW/cm(2)); 2) soft-start (SS: 10 seconds at 150 mW/cm(2)+24 seconds at 600 mW/cm(2)); and 3) pulse delay (PD: five seconds at 150 mW/cm(2)+three minutes with no light+25 seconds at 600 mW/cm(2)). The radiant exposure for all groups was 16 J/cm(2). Marginal adaptation was measured with the dye staining gap procedure, using Caries Detector. Outer margins were stained for five seconds and the gap percentage was determined using digital images on a computer measurement program (Image Tool). Then, specimens were sectioned in slices and stained for five seconds, and the internal gaps were measured using the same method. Data were submitted to two-way analysis of variance and Tukey test (p<0.05). Composite volume had a significant influence on superficial and internal gap formation, depending on the curing method. For CL groups, restorations with higher volume showed higher marginal gap incidence than did the lower volume restorations. Additionally, the effect of the curing method depended on the volume. Regarding marginal adaptation, SS resulted in a significant reduction of gap formation, when compared to CL, for higher volume restorations. For lower volume restorations, there was no difference among the curing methods. For internal adaptation, the modulated curing methods SS and PD promoted a significant reduction of gap formation, when compared to CL, only for the lower volume restoration. Therefore, in similar conditions of the cavity configuration, the higher the volume of composite, the greater the gap formation. In addition, modulated curing methods (SS and PD) can improve the interfacial quality of composite restorations through the reduction of internal gaps in lower volume composite restoratives.
Collapse
Affiliation(s)
- Eduardo José Souza-Junior
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas-UNICAMP, Piracicaba–SP, Brazil
| | | | | | | | | | | |
Collapse
|