1
|
Effect of incorporation of calcium polyphosphate sub-microparticles in low-concentration bleaching gels on physical properties of dental enamel. Odontology 2023:10.1007/s10266-023-00875-0. [PMID: 38148447 DOI: 10.1007/s10266-023-00875-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Accepted: 11/14/2023] [Indexed: 12/28/2023]
Abstract
AIM To evaluate the bleaching efficacy and effects on enamel properties of experimental gels with carbamide peroxide (CP; 10%) or hydrogen peroxide (HP; 6%) containing calcium polyphosphate sub-microparticles (CaPPs). METHODS A total of 216 bovine tooth specimens were divided for microhardness and color analyses (n = 108) and block randomized into nine groups (n = 12): (G1) commercial CP (Whiteness Perfect, FGM; Brazil); (G2) experimental CP; (G3) CP-0.5%CaPPs; (G4) CP-1.5%CaPPs; (G5) commercial HP (Potenza Bianco, PHS; Brazil); (G6) experimental HP; (G7) HP-0.5%CaPPs; (G8) HP-1.5%CaPPs; (G9) artificial saliva. The gels' pH values were determined with a bench pH meter. Color (ΔE, ΔE00, ΔWID) and microhardness variation were evaluated before and after the therapy. Part of the specimens used for microhardness was submitted to the scanning electron microscopy (SEM) (n = 3) and energy-dispersive X-ray spectroscopy EDX (n = 3) analyses. Statistical analyses were performed in the R statistical software (α = 0.05). Linear mixed models for repeated measures in time were used to analyze microhardness and L* values. Generalized linear models were used to analyze the a*, b*, ΔE, ΔE00, and ΔWID, considering a group effect. The EDX data were analyzed using a one-way ANOVA with Tukey's test. RESULTS The gels' pH remained over 6,0. All gels effectively bleached the specimens and did not differ significantly. When compared to the control group, the hardness was significantly lower in the G1, G2, G6, and G7 groups. The G3, G4, G5, and G8 groups did not differ significantly (p > 0.05). CONCLUSION The incorporation of CaPPs in low-concentration whitening gels reduces its negative effects on microhardness without interfering with their bleaching efficacy.
Collapse
|
2
|
Evaluation of at-home bleaching protocol with application on different surfaces: bleaching efficacy and hydrogen peroxide permeability. Restor Dent Endod 2023; 48:e33. [PMID: 38053778 PMCID: PMC10695734 DOI: 10.5395/rde.2023.48.e33] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 08/04/2023] [Accepted: 08/08/2023] [Indexed: 12/07/2023] Open
Abstract
Objectives This study aimed to evaluate the bleaching efficacy and hydrogen peroxide permeability in the pulp chamber by the at-home bleaching gel in protocols applied on different dental surfaces. Materials and Methods Forty premolars were randomly into 4 groups: control group no bleaching, only application on the buccal surface (OB), only application on the lingual surface (OL) and application in buccal and lingual surfaces, simultaneously (BL). At-home bleaching gel (White Class 7.5%) was used for the procedure. The bleaching efficacy was evaluated with a digital spectrophotometer (color change in CIELAB [ΔE ab] and CIEDE 2000 [ΔE 00] systems and Whitening Index for Dentistry [ΔWID]). The hydrogen peroxide permeability in the pulp chamber (µg/mL) was assessed using UV-Vis spectrophotometry and data were analyzed for a 1-way analysis of variance and Tukey's test (α = 0.05). Results All groups submitted to bleaching procedure showed bleaching efficacy when measured with ΔE ab and ΔE 00 (p > 0.05). Therefore, when analyzed by ΔWID, a higher bleaching efficacy were observed for the application on the groups OB and BL (p = 0.00003). Similar hydrogen peroxide permeability was found in the pulp chambers of the teeth undergoing different protocols (p > 0.05). Conclusions The application of bleaching gel exclusively on the OB is sufficient to achieve bleaching efficacy, when compared to BL. Although the OL protocol demonstrated lower bleaching efficacy based on the ΔWID values, it may still be of interest and relevant in certain clinical scenarios based on individual needs, requiring clinical trials to better understand its specificities.
Collapse
|
3
|
Whitening efficacy and tooth sensitivity in a combined in-office and at-home whitening protocol: A randomized controlled clinical trial. J ESTHET RESTOR DENT 2023; 35:821-833. [PMID: 36883730 DOI: 10.1111/jerd.13033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 02/09/2023] [Accepted: 02/25/2023] [Indexed: 03/09/2023]
Abstract
OBJECTIVE This controlled randomized clinical trial determined the whitening efficacy and the intensity and absolute risk of tooth sensitivity in dual whitening when prefilled at-home whitening trays were used between in-office whitening intervals. MATERIALS AND METHODS An in-office whitening agent containing 35% hydrogen peroxide was used. A prefilled tray with a whitening agent containing 6% hydrogen peroxide was used for at-home whitening. Sixty-six subjects were randomly assigned to three groups. Group I: at-home whitening was performed 10 times between the in-office whitening treatments. Group II: at-home whitening was performed five times between the in-office whitening treatments. Group III: only in-office whitening was performed. The tooth color changes were evaluated using a spectrophotometer. A visual analog scale was used to express the pain intensity. RESULTS All the groups showed increased ΔE*ab, ΔE00 , and ΔWID with increased whitening sessions. Group I at the 3rd whitening session showed significantly higher ΔE*ab, ΔE00 , and ΔWID than group III. Tooth sensitivity showed higher values up to 24 h after whitening. CONCLUSIONS Although dual whitening with the prefilled tray and in-office whitening had higher whitening ability than in-office whitening alone, the intensity and absolute risk of tooth sensitivity was similar. CLINICAL RELEVANCE The dual whitening might produce faster and stronger whitening effects than in-office whitening alone.
Collapse
|
4
|
Does simultaneous versus individual-arch at-home dental bleaching regimen influence patient satisfaction? A randomized clinical trial. J ESTHET RESTOR DENT 2022; 34:1263-1271. [PMID: 36125103 DOI: 10.1111/jerd.12962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 08/26/2022] [Accepted: 08/29/2022] [Indexed: 12/01/2022]
Abstract
OBJECTIVE Our randomized, parallel and single-blinded clinical trial evaluated patient level of discomfort during at-home bleaching testing the equivalence between two different protocols for the use of bleaching trays (simultaneous vs. single arch), as well as tooth sensitivity (TS), gingival irritation, (GI) and bleaching efficacy (BE). MATERIALS AND METHODS We randomized 100 patients into: simultaneous (n = 50) and single arch (n = 50). At-home bleaching was performed with 10% hydrogen peroxide (HP) for 2 weeks for simultaneous group and 4 weeks for single arch group. We assessed patient level of discomfort using 9-item questionnaire. The TS and GI, as well as BE using spectrophotometer and color guide were assessed using the visual analog scale (0-10). Data from level of discomfort and BE were evaluated by Student's t test. The TS and GI were compared using the relative risk and confidence interval (α = 0.05). RESULTS Only tray adaptation showed a significant effect after the second week (p < 0.002). There was equivalence between groups for level of discomfort (p < 0.01). We found no significant intergroup differences for the risk of TS or GI, nor for intensity. We observed no significant differences between them regarding bleaching efficacy (p > 0.21). CONCLUSIONS A simultaneous-use protocol for customized at-home dental bleaching trays proved to be equivalent to using single arch for patient level of discomfort and bleaching efficacy, with no significant increase in adverse effects. CLINICAL SIGNIFICANCE Clinicians may decide whether to use a simultaneous or single arch protocol for tray usage; however, bleaching was achieved more quickly when the trays were worn simultaneously.
Collapse
|
5
|
|
6
|
Combined Bleaching Technique Versus At-home Bleaching-A Single-blind Randomized Controlled Trial. Oper Dent 2022; 47:247-257. [PMID: 35653595 DOI: 10.2341/20-283-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/18/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To compare the efficacy, color stability, and tooth sensitivity (TS) of combined bleaching, using a modified protocol with at-home bleaching. METHODS Eighty participants were randomized into two groups. In the combined group, a desensitizing gel was applied (10 minutes) prior to in-office bleaching (35% hydrogen peroxide (H2O2), 2×15 minute applications) and at-home bleaching (4% H2O2, 2×30 minutes for 21 days) started the next day. In the at-home group, only the at-home bleaching was performed. Color was recorded at the beginning and postbleaching with two scales (VITA Classical and Bleachedguide) and Easyshade spectrophotometer. The TS was recorded daily with a 0-10 visual analogue scale (VAS) and five-point numeric rating scale (NRS). RESULTS A 40% lower risk (RR=1.4; 95% CI 1.1-1.9) was observed in the at-home group. Higher color change and intensity of TS [mean difference 2.3 (95% CI 1.3-3.3) in the VAS] was observed in the first week for the combined group. After the end of the protocol, a bleaching degree was detected for both groups, with no significant difference between both groups (p>0.05). CONCLUSION The combined group produced a slightly higher degree of color change than at-home bleaching but with a higher risk and intensity of TS.
Collapse
|
7
|
Effects of microabrasion association to at-home bleaching on hydrogen peroxide penetration and color change. J ESTHET RESTOR DENT 2022; 34:335-341. [PMID: 34723443 DOI: 10.1111/jerd.12830] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 09/28/2021] [Accepted: 10/18/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE This study aimed to quantify the penetration of hydrogen peroxide (HP) inside the pulp cavity and color change with two different concentrations of HP to at-home bleaching associated or not with enamel microabrasion (MA). METHODS Forty healthy premolars were randomly divided in four groups (n = 10): only HP4%, MA + HP4%, only HP10%, MA + HP10%. The concentration (μg/ml) of HP was assessed using UV-Vis spectrophotometry. The color change (ΔEab , ΔE00 and WID ) was evaluated before and one-week after bleaching. Data were evaluated for a two-way ANOVA and the Tukey's test (α = 0.05). RESULTS The application of MA increased the amounts of HP inside the pulp chamber when compared to without MA, as well as PH10% when compared to PH4% (p < 0.0001). PH10% showed higher WID when compared to PH4%. No significant difference was observed when ΔEab , and ΔE00 were used. CONCLUSIONS The enamel MA before at-home bleaching promotes greater penetration of HP, although this procedure did not significantly affect the color change. CLINICAL SIGNIFICANCE Since greater penetration of HP into the pulp chamber was detected when home bleaching was applied immediately after MA, the clinician should not apply home bleaching gels in the same session when MA was performed.
Collapse
|
8
|
Gingival irritation in patients submitted to at-home bleaching with different cutouts of the bleaching tray: a randomized, single-blind clinical trial. Clin Oral Investig 2022; 26:4381-4390. [DOI: 10.1007/s00784-022-04401-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 02/01/2022] [Indexed: 11/03/2022]
|
9
|
Triple-blinded randomized clinical trial comparing efficacy and tooth sensitivity of in-office and at-home bleaching techniques. J Appl Oral Sci 2021; 29:e20200794. [PMID: 34614118 PMCID: PMC8523096 DOI: 10.1590/1678-7757-2020-0794] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 06/29/2021] [Indexed: 11/22/2022] Open
Abstract
Objective Our study aims to compare the efficacy and tooth sensitivity following in-office (35% hydrogen peroxide) or at-home (10% carbamide peroxide) bleaching treatments both preceded by 2% potassium nitrate (2%KF) desensitizing gel. Methodology 130 volunteers were randomly allocated to a) in-office bleaching and a placebo at-home protocol; or b) in-office placebo and at-home bleaching treatment. 2% KF was applied for 10 min before both treatments. Objective color evaluation was performed (spectrophotometer CIEL*a*b* system and CIEDE2000) to calculate the color change (ΔE00). Subjective evaluation was performed using the VITA classical shade guide followed by shade variation (ΔSGU) at the beginning and end of bleaching treatment and 2 weeks post-bleaching. Tooth sensitivity was daily recorded using a Likert scale varying from 1 (no sensitivity) to 5 (severe sensitivity). Analysis was carried out using non-parametric tests. Results Regarding the color change, at-home bleaching resulted in significant color improvement compared to in-office treatment for the parameters Δb* (p=0.003) and Δa* (p=0.014). Two weeks post-bleaching, the at-home treatment resulted in significant color improvement compared to in-office treatment for the parameters Δb* (p=0.037) and ΔE00 (p=0.033). No differences were observed in either ΔSGU parameters. Concerning sensitivity, patients treated with in-office bleaching reported more tooth sensitivity than the at-home group only on the first day after bleaching started, without significant differences in the other periods evaluated (p>0.05). Conclusions At-home and in-office bleaching, preceded by a desensitizing agent, were effective for vital teeth bleaching and 10% carbamide peroxide produced a higher whitening effect than 35% hydrogen peroxide in the short time evaluation. Tooth sensitivity rates were similar for the two techniques tested.
Collapse
|
10
|
Is the at-home bleaching treatment applied only on the lingual surface as effective as that on the buccal surface? A randomized clinical trial. Clin Oral Investig 2021; 26:1551-1560. [PMID: 34410498 DOI: 10.1007/s00784-021-04128-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 08/03/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVES This double-blind randomized clinical trial compared the effectiveness and bleaching sensitivity (BS) of at-home dental bleaching performed on the buccal surface and on the lingual surface. METHODS Using a split-mouth design, 25 patients were assigned to two bleaching groups: 10% hydrogen peroxide (White Class 10%, FGM) applied once daily for 60 min to the buccal surface (BSB) and 10% hydrogen peroxide (White Class 10%, FGM) applied once daily for 60 min to the lingual surface (LSB), both for 14 days. The color was evaluated before bleaching, after the first and second weeks, and 1 month after the bleaching using Vita Classical and Vita Bleachedguide scales and a Vita Easyshade spectrophotometer. BS was recorded daily using a 0-4 numerical rating scale and a 0-10 visual analogue scale. The following statistical tests were used: color changes (Mann-Whitney), absolute risk of BS (McNemar's exact), and the intensity of BS (Mann-Whitney). In all statistical tests, the significance level was 5%. RESULTS Significant bleaching was observed after the end of bleaching in both groups, with higher bleaching effectiveness for BSB when compared to LSB (p < 0.05). Regarding BS, no significant difference was observed between groups (p = 1.00). CONCLUSIONS The 10% hydrogen peroxide (White Class 10%, FGM) applied in at-home bleaching performed on the lingual surface did not promote a similar result of color change compared to on the buccal surface. Regarding BS, there was no significant difference between the groups. CLINICAL RELEVANCE The at-home bleaching performed on the lingual surface promotes a lower result in the color change. BS is similar between the groups. CLINICAL TRIAL REGISTRATION NUMBER RBR-283byt.
Collapse
|
11
|
Efficacy and tooth sensitivity of at-home bleaching in patients with esthetic restorations: a randomized clinical trial. Clin Oral Investig 2021; 26:565-573. [PMID: 34383143 DOI: 10.1007/s00784-021-04035-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 06/10/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES This study aims to evaluate the color change and tooth sensitivity (TS) caused by at-home bleaching in patients with sound and with restored teeth. METHODS Forty patients were selected according to the inclusion and exclusion criteria and divided into two groups: So (patients with six caries-free maxillary anterior teeth) and Re (patients with at least one restoration in the six maxillary anterior teeth). Both groups were bleached with 10% carbamide peroxide (CP) at-home bleaching. The color change (CIELab [ΔE*ab], CIEDE00 [ΔE00], and whiteness index [∆WID]) were assessed using a spectrophotometer at baseline, 2 weeks, and 1 and 3 months after bleaching. Patients recorded their TS using a numeric rating scale (0-4). Data of color change were submitted to Student's T-test. The absolute risk and intensity of TS were compared using Fisher's and the Mann-Whitney tests, respectively (α = 0.05). RESULTS Higher ΔE*ab, ΔE00, and ∆WID values were observed for So in relation to Re after all recall rate (p < 0.0001). No significant differences were observed regarding of bleaching-induced TS (p > 0.9). CONCLUSIONS At-home dental bleaching with 10% CP generated the same pattern of TS in patients with or without restorations. However, in patients with restored teeth, it produced a lower color change after 2 weeks of bleaching. CLINICAL SIGNIFICANCE After 2 weeks of at-home bleaching, a lower whitening effect was observed in patients with anterior restorations when compared with patients with sound teeth. TRIAL REGISTRATION ClinicalTrials.gov identifier RBR-52j6gmg.
Collapse
|
12
|
Evaluation of At-home Bleaching Times on Effectiveness and Sensitivity with 10% Hydrogen Peroxide: A Randomized Controlled Double-blind Clinical Trial. Oper Dent 2021; 46:385-394. [PMID: 34370025 DOI: 10.2341/20-104-c] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The aim of this randomized double-blind controlled clinical trial was to evaluate different protocols for at-home use of 10% hydrogen peroxide in whitening effectiveness and tooth sensitivity. METHODS Seventy-two patients were selected according to the inclusion and exclusion criteria, with the upper central incisors having color A2 or darker according to the Vita Classical scale (VITA Zahnfabrik, Bad Säckingen, Germany) and randomized into two groups: 10% hydrogen peroxide applied once daily for 15 minutes (HP 15) or applied once daily for 30 minutes (HP 30). Bleaching was performed for 14 days in both groups. The color was evaluated before bleaching, during bleaching (1st and 2nd weeks), and 1 month after the bleaching treatment using the Vita Classical, Vita Bleachedguide 3D-MASTER, and Vita Easyshade spectrophotometer (VITA Zahnfabrik). Dental sensitivity was recorded by the patients using the numerical rating scale (0-4) and visual analogue scale (0-10 cm). Color data were evaluated by two-way analysis of variance (ANOVA) of repeated measures (group vs. treatment time). The Mann-Whitney test was performed to contrast the means (α=0.05). Tooth sensitivity was assessed by Fisher's exact test (p=1.00) and intensity of tooth sensitivity was evaluated by the Mann-Whitney test (α=0.05) for both scales. RESULTS A significant whitening effect was observed after 2 weeks of bleaching for all color measurements (p=0.01), with no difference between HP 15 and HP 30 (p>0.05). Also, the absolute risk and intensity of tooth sensitivity were similar (47%; p>0.05). CONCLUSIONS The effectiveness and tooth sensitivity of at-home bleaching carried out with 10% hydrogen peroxide applied for 15 minutes or 30 minutes are similar.
Collapse
|
13
|
One-year follow-up evaluation of reservoirs in bleaching trays for at-home bleaching. J ESTHET RESTOR DENT 2021; 33:992-998. [PMID: 34212493 DOI: 10.1111/jerd.12797] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 05/05/2021] [Accepted: 06/14/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the color change stability and patient satisfaction after one-year of at-home bleaching with 10% carbamide peroxide (CP) in trays with or without reservoirs. MATERIALS AND METHODS Forty-six patients were subjected to bleaching with CP (3 h/daily; 21 days) with a bleaching tray with or without reservoirs. The color was measured one-month and one-year after the completion of bleaching using the spectrophotometer (ΔEab, Δ00 and ΔWi), and shade guide units (ΔSGU). Patients' satisfaction were assessed using a 5-point Likert Scale questionnaire. Data were submitted to paired t-test (α = 0.05). RESULTS No significant difference between color change after one-month and one-year was observed (VITA Classical shade guide unit and the ΔWi; p > 0.53). Significant differences were observed for the VITA Bleachedguide 3D-MASTER shade guide, ΔEab and ΔE00 (p < 0.03). The level of patient satisfaction was similar between groups (p = 1.00). CONCLUSIONS Bleaching tray design did not have any influence on the bleaching stability for the 10% CP (Opalescence PF, Ultradent). Patients were very satisfied with the bleaching outcomes regardless of the bleaching tray design. CLINICAL RELEVANCE Placement of reservoirs in bleaching trays does not increase longevity of dental bleaching. No clinically important color rebound was observed 1 year after bleaching with 10% CP.
Collapse
|
14
|
Effect of Daily Usage Time of 4% Hydrogen Peroxide on the Efficacy and Bleaching-induced Tooth Sensitivity: A Single-blind Randomized Clinical Trial. Oper Dent 2021; 46:395-405. [PMID: 34425585 DOI: 10.2341/20-058-c] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/19/2019] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Compare the risk/intensity of tooth sensitivity (TS) and color change of a 30-minute vs. the recommended 120-minute application time of 4% hydrogen peroxide (HP) for at-home bleaching. METHODS A single-blind, parallel, randomized clinical trial was conducted with 92 adult patients with caries and restoration-free anterior teeth A2 or darker, randomly allocated to two groups. Bleaching trays containing 4% HP were used for three-weeks. A four-week regimen was also offered to the patients for the 30-min group after the end of the 3-week protocol. The color change was assessed with the Vita Classical (VITA Zahnfabrik, Bad Säckingen, Germany) and Vita Bleachedguide shade guides (VITA Zahnfabrik) and the Vita Easyshade spectrophotometer (VITA Zahnfabrik) at baseline, weekly, and 30 days after the bleaching. The absolute risk and the intensity of TS were assessed daily using the 0-10 visual analogue scale (VAS) and 5-point Numerical Rating Scale (NRS) scale, and patient satisfaction was recorded with a Likert 0-7 scale. Risk of TS (Fisher's test), intensity of TS in NRS scale (Mann-Whitney test), VAS scale (t-test), and a color change (t-test) were compared. RESULTS The 30-minute group saw color change of around 1 SGU inferior to the 120-minute group in all-time assessments (p<0.05). After an extra week of bleaching, mean color change was similar (p>0.05). Patient satisfaction was high for both groups (p>0.05). CONCLUSIONS A four-week protocol of at-home dental bleaching with 4% HP for 30 minutes/day whitened teeth similarly to the 120 minutes/day protocol, with low intensity of dental sensitivity and high patient satisfaction.
Collapse
|
15
|
In vitro analysis of the pH stability of dental bleaching gels during in-office procedures. J Clin Exp Dent 2021; 13:e22-e29. [PMID: 33425227 PMCID: PMC7781220 DOI: 10.4317/jced.57367] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 09/23/2020] [Indexed: 11/05/2022] Open
Abstract
Background Previous studies have shown that acidic bleaching gels could lead to worse collateral effects during an in-office bleaching procedure, while neutral or basic products leads towards a better experience. Considering this fact, the main purpose of this study was to evaluate the pH behavior of 6 in-office bleaching gels, compared to the information provided by their manufacturers.
Material and Methods Thirty enamel discs of bovine teeth were prepared, the initial colors of which were measured by a spectrophotometer and then divided into 6 groups. A pH meter was used to measure the pH every 30 seconds until the end of each procedure, when a new color evaluation was then made. The Tukey test was used for statistical analysis of the results.
Results There was no difference in the color variation (ΔE) between the groups (p> 0.05). In two groups, the pH variation (ΔpH) showed neutral stability, with initial and final pH averages of 7.04 and 7.11 (p = 0.08) and 7.21 and 7.19 (p = 0.55), respectively; in another, there was alkaline stability, with an initial and final pH average of 8.54 and 8.37 (p = 0.14). In the other three brands, however, the results showed acidification, with initial and final pH averages of 6.14 and 5.22 (p = 0.001), 6.05 and 5.16 (p = 0.001) and 7.14 and 5.83 (p = 0.001), respectively.
Conclusions In 3 of the evaluated gels, a discrepancy existed between the manufacturer’s information and the data obtained, which could lead, considering previous studies discussed throughout this article, to unexpected collateral effects on the patients, especially dental sensitivity. Thus, clinicians and researchers should be aware about pH stability studies of in-office bleaching gels for better predictability and safety on their clinical usage. Key words:Tooth bleaching, Bleaching agents, Hydrogen-ion concentration, Dentin sensitivity, Hydrogen peroxide.
Collapse
|
16
|
A novel carbamide peroxide polymeric nanoparticle bleaching gel: Color change and hydrogen peroxide penetration inside the pulp cavity. J ESTHET RESTOR DENT 2020; 33:277-283. [PMID: 32949453 DOI: 10.1111/jerd.12652] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 08/17/2020] [Accepted: 08/25/2020] [Indexed: 12/23/2022]
Abstract
OBJECTIVE This study evaluated the hydrogen peroxide (HP) penetration inside the pulp cavity and the color change of teeth submitted to the 15% carbamide peroxide (CP) nanoparticle bleaching gel at several application times. MATERIALS AND METHODS Premolars were divided into nine groups (n = 6) according to 15% CP bleaching agents (nanoparticle and commercial) and to application times (15, 30, 45, and 60 minutes). A negative control was exposed to ultra-purified water. After a whitening procedure, the HP concentration (μg/mL) inside the pulp cavity was assessed via spectrophotometry. The color change (ΔE* and ΔE00*) was evaluated with a spectrophotometer. Data were analyzed via two-way ANOVA and Tukey (α = 0.05). RESULTS A lower concentration of HP was detected for CP nanoparticle gel after 30 and 45 minutes of whitening procedure (P = .001). The bleaching groups promoted a higher color change (ΔE* and ΔE00*) regardless of the application time (P = .0001). CONCLUSIONS The CP nanoparticle gel reduced HP inside the pulp cavity, and showed effective bleaching compared with CP commercial gel. CLINICAL SIGNIFICANCE Using 15% carbamide peroxide nanoparticle bleaching gel decreased the HP penetration inside the pulp cavity and may decrease bleaching-induced tooth sensitivity in at-home bleaching.
Collapse
|
17
|
The bleaching efficacy of carbamide peroxide gels containing potassium nitrate desensitizer. J Clin Exp Dent 2020; 12:e644-e649. [PMID: 32905070 PMCID: PMC7462381 DOI: 10.4317/jced.56917] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 04/13/2020] [Indexed: 12/02/2022] Open
Abstract
Background To evaluate the bleaching efficacy of at-home carbamide peroxide (CP) gels in two concentrations, containing or not a desensitizing agent.
Material and Methods Forty incisors were divided into four groups (n=10), according to gel concentrations (10% or 22%), and presence or not of 3% potassium nitrate in the gel. A thin layer of gel was applied to the buccal surface of each tooth for 2h/day for 4 weeks. Bleaching efficacy was measured using a spectrophotometer, and ∆E*ab, ∆E00 and ∆WID were calculated. Measurements were performed at baseline, 7, 14, 21, 28, and 35 days following the first gel application. Data were analyzed by two-way RM-ANOVA and Tukey’s test (α=0.05).
Results Regarding gel concentration or potassium nitrate inclusion, both gels resulted in color change above the perceptibility thresholds, which were similar between gels. Regarding time, significant differences were observed between color change values at 7 days and other time periods. ∆WID ranged from 3.8 to 9.6. Significant moderate to strong positive correlation was observed among the parameters.
Conclusions Nor the CP concentration, neither the inclusion of potassium nitrate in the gel, had influence on bleaching efficacy. All gels were effective and showed good results from the first weeks’ application. Key words:Tooth bleaching, carbamide peroxide, desensitizer, potassium nitrate, color.
Collapse
|
18
|
A review on dental whitening. J Dent 2020; 100:103423. [PMID: 32615235 DOI: 10.1016/j.jdent.2020.103423] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Revised: 04/20/2020] [Accepted: 06/27/2020] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVES To provide a narrative review on vital dental whitening chemistry, toxicity and safety, vital dental whitening techniques, whitening systems, potential side effects of whitening and cyclic whitening using products with a range of concentrations and pH values. In addition, new developments and recommendations in the field of vital dental whitening will be presented to help clinicians understand the whitening process, its advantages, limitations, and the impact of whitening concentration and pH on enamel providing guidance in tailoring whitening treatments. DATA Data were gathered using the following keywords: dental whitening, roughness, hardness, sensitivity, hydrogen peroxide, whitening pH, whitening concentration, whitening chemistry, colour, and toxicity. SOURCES An electronic search was performed using PubMed and Scopus databases. Bibliographic material from papers reviewed was then used to find other relevant publications. CONCLUSIONS The effectiveness of vital dental whitening depends on many factors, such as the concentration/pH of the whitening agent, application duration, chemical additives, and re-mineralising agents used. Developing new whitening products and technologies such as nano-additives and alternative carrier systems is showing promising results, and might prove efficient in maximising whitening benefits by accelerating the whitening reaction and/or minimising expected reversible/irreversible enamel structural damage.
Collapse
|
19
|
Abstract
Regardless of the extensive availability of mouth rinses that claim to whiten teeth, evidence of achievement of such effect is still missing. Aim: Therefore, this study assessed in vitro the whitening effectiveness of whitening mouth rinses. Methods: Sixty intact bovine incisors were embedded in acrylic resin and had their buccal surface flattened and polished. Then, the specimens were randomly allocated to three conventional (Colgate Plax, Cepacol and Listerine Cool Mint) and three whitening mouth rinse groups (Colgate Luminous White, Cepacol Whitening and Listerine Whitening Extreme) (n=10). Following, the specimens were immersed twice a day in the mouth rinses for one minute for 28 days. In between each immersion period, the specimens remained in artificial saliva at 37oC. Color was measured at baseline, 7, 14, 21, and 28 days using a portable spectrophotometer (Easyshade, Vita Zahnfabrik, Germany) with a 6 mm of diameter probe. Color change was analyzed considering the parameters of ∆L*, ∆a*, ∆b* and, ultimately, ∆E*. The whitening efficacy of the mouth rinses was analyzed using the Whiteness Index for Dentistry (WID). Data of ∆s was analyzed using two-way ANOVA and Tukey’s test (α=0.05). Results: The type of mouth rinse affected significantly all the ∆ parameters (p<0.05). A non-whitening (conventional) mouth rinse produced the highest ΔE*, followed by the three whitening mouth rinses. The application time also affected ΔE* (p<0.05), with emphasis on the third week of treatment. Only the hydrogen peroxide-containing mouth rinse (Listerine Whitening Extreme) presented a whitening effect, with an increasing trend over time. Conclusion: Although the overall color change was not different when comparing conventional and whitening mouth rinses, the hydrogen peroxide-containing whitening mouth rinse produces an increasing whitening trend over time. Not every mouth rinse that claims to whiten teeth produces the desired effect.
Collapse
|
20
|
Effect of Analgesic Drugs on Tooth Sensitivity Induced by In-office Dental Bleaching: A Systematic Review and Meta-analysis. Oper Dent 2019; 45:E66-E76. [PMID: 31750804 DOI: 10.2341/18-250-l] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This systematic review evaluates the effect of preemptive analgesia on tooth sensitivity induced by in-office tooth bleaching. METHODS The review was structured based on the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) checklist. The methods were recorded at PROSPERO (CRD42018095440). Randomized clinical trials, studies published in English, and studies in which the efficacy of preemptive analgesia with analgesic and anti-inflammatory medications prior to in-office tooth bleaching was compared with that of placebo were included. PubMed/MEDLINE, Scopus, Web of Science, and Cochrane Library were used for searching. The electronic search provided 373 articles, and seven of them were selected based on the inclusion criteria. RESULTS Immediately after time point, a significant reduction of dental sensitivity was observed in the drug group compared to the control group (p=0.02; mean difference [MD]: -0.90; confidence interval [CI]: -1.63 to -0.16), while there was no significant difference at up to one-hour (p=0.22; MD: -0.42; CI: -1.09 to -0.25), at 1-24-hour (p=0.88; MD: -0.05; CI: -0.61 to 0.72), or 24-48-hour (p=0.69; MD: 0.05; CI: -0.21 to 0.32) time points. The incidence of sensitivity during the procedure was not statistically different between the groups (p=0.64; MD: 0.91; CI: 0.92 to 1.15). The nonsteroidal anti-inflammatory drug group showed a statistically significant reduction (p=0.04; MD: -0.69; CI: -1.36 to -0.03) in tooth sensitivity compared with the other groups. CONCLUSIONS This systematic review and meta-analysis demonstrated that the medications analyzed did not interfere with the incidence of sensitivity symptoms. Regarding the intensity, no difference was observed between the drug and placebo groups at the up to one-hour, 1-24-hour, or 24-48-hour time points, and there was a statistically significant difference at the zero-hour time point in favor of the drug group. However, based on the variables that influenced this result, it should be considered with prudence because a small difference was observed.
Collapse
|
21
|
Effects of different discoloration challenges and whitening treatments on dental hard tissues and composite resin restorations. J Dent 2019; 89:103182. [DOI: 10.1016/j.jdent.2019.103182] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 07/12/2019] [Accepted: 08/16/2019] [Indexed: 12/11/2022] Open
|
22
|
Are combined bleaching techniques better than their sole application? A systematic review and meta-analysis. Clin Oral Investig 2019; 23:3673-3689. [PMID: 31468261 DOI: 10.1007/s00784-019-03042-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Accepted: 08/05/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVES A systematic review and meta-analysis were performed to answer this research question: "Does combined in-office (IO) and at-home (AH) bleaching produce improved color change and lower tooth sensitivity (TS) better than solely AH or IO bleaching in adults?" MATERIAL AND METHODS Randomized controlled trials in adults that compared combined versus sole application bleaching were included. The risk of bias (RoB) was evaluated using the Cochrane Collaboration tool. Meta-analyses were conducted for color change in shade guide units (∆SGU) and with a spectrophotometer (∆E*), risk, and intensity of TS, using the random effects model. Heterogeneity was assessed with Cochran's Q test and I2 statistics. GRADE assessed the quality of the evidence. PubMed, Scopus, Web of Science, LILACS, BBO, Cochrane Library, SIGLE, IADR abstracts, unpublished, ongoing trial registries, dissertations, and theses were searched on August 28, 2017 (updated on January 29, 2019). RESULTS Twelve studies remained. Two were considered to have low RoB. For combined vs. IO bleaching, no significant difference for ∆E*, ∆SGU, and risk of TS were observed; data were not available to analyze the intensity of TS. For combined vs. AH bleaching, no significant difference for ∆E*, ∆SGU, but lower TS to risk (RR 1.40, 95% 1.10 to 1.80) and intensity (MD 1.40, 95% CI 0.18 to 2.63) were detected for AH bleaching. Quality of evidence was graded as low or very low in all meta-analyses. CONCLUSION Lower risk and intensity of TS was observed for the solely AH group without jeopardizing color change. However, more studies are still encouraged due to the low quality of evidence for most of the outcomes. CLINICAL RELEVANCE If clinicians are to choose between combined or sole AH bleaching, the solely AH may be preferable; combined bleaching may potentiate the risk of TS without benefits in color change. For combined or sole IO bleaching, no important clinical difference in color change and risk of TS were detected; however, intensity of TS could not be compared due to lack of data. Further studies should be conducted due to the low/very low quality of the evidence.
Collapse
|
23
|
In vitro evaluation of experimental light activated gels for tooth bleaching. Photochem Photobiol Sci 2019; 18:1009-1019. [PMID: 30724960 DOI: 10.1039/c8pp00223a] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Dental bleaching is an important part of aesthetic dentistry. Various strategies have been created to enhance the bleaching efficacy. As one such strategy, light-activated nanoparticles that enable localized generation of reactive oxygen species have been developed. Here, we evaluated the cellular response to experimental gels containing these materials in in vitro models. L-929 cells, 3T3 cells, and gingival fibroblasts were exposed to the gels at 50%, 10%, 2%, 0.4%, 0.08%, 0.016%, and 0.0032%. The gels contained TiO2/Ag nanoparticles, TiO2 nanoparticles, hydrogen peroxide (6% hydrogen peroxide), or no added component and were tested with and without exposure to light. Cells were exposed to gels for 24 h or for 30 min. The latter case mimics the clinical situation of a short bleaching gel exposure. Metabolic activity and cell viability were evaluated with MTT and neutral red assays, respectively. We found a dose-dependent reduction of formazan formation and neutral red staining with gels containing TiO2/Ag nanoparticles or TiO2 nanoparticles in the 24 h setting with and without illumination. The strongest reduction, which was not dose-dependent in the evaluated concentrations, was found for the gel containing hydrogen peroxide. Gels with TiO2 nanoparticles showed a similar response to gel without particles. TiO2/Ag gel showed a slightly higher impact. When the gels were removed by rinsing after 30 min of exposure without light illumination, gel containing TiO2/Ag nanoparticles showed a stronger reduction of formazan formation and neutral red staining than gel containing TiO2 particles. Exposure of cells for 30 min under illumination and consequent rinsing off the gels also showed that Ag-containing particles can have a higher impact on the metabolic activity and viability than particles from TiO2. Overall our results show that experimental bleaching gels containing TiO2/Ag or TiO2 nanoparticles are less cytotoxic than hydrogen peroxide-containing gel. When gels are removed, gel containing TiO2/Ag particles exhibit a stronger reduction of metabolic activity and viability than the gel containing TiO2.
Collapse
|
24
|
Dental Whitening Gels: Strengths and Weaknesses of an Increasingly Used Method. Gels 2019; 5:gels5030035. [PMID: 31277412 PMCID: PMC6787621 DOI: 10.3390/gels5030035] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Accepted: 07/01/2019] [Indexed: 02/07/2023] Open
Abstract
Many people nowadays undergo treatments to improve their aesthetics, often neglecting the general state of health. Aesthetics and appearance have become of prime importance, perhaps correlating with of the advent of social networks and digital photographs. One of the most requested aesthetic treatments for dentists is dental bleaching through the use of whitening gels. Dental bleaching is a treatment which involves an improvement in the chrome of the teeth in a short time, and this treatment appears not invasive for the patients. In-office and at-home bleaching treatments can be found. The purpose of this scientific study is to evaluate all of the advantages and disadvantages of this medical treatment. In this study, were report information and items related to bleaching side effects. Dentists often find themselves in disagreement on this topic. The PICO (Population/Intervention/Comparison/Outcome) question investigated was: Are dental patients who have dental bleaching an increased risk of teeth damage? All of the data in the literature has been collected, and all of the side effects of this treatment were evaluated. 263 studies emerged from initial research; only 14 were screened after screening, as they contained sufficient data to evaluate the side effects of treatment. One certain thing emerged; among the contraindications to the treatment of dental bleaching dentinal hypersensitivity could be cited. In fact, one of the most reported undesirable effects regards this problem. Other studies have evaluated pain, color improvement and duration, or patient satisfaction. Dental bleaching is a treatment that aims to improve the aesthetics of our patients; this is also reflected from a psychological point of view and therefore has effects on general health. However, the whitening treatment is not suitable for everyone and must be carefully evaluated by a specialist. This treatment also entails maintenance by the patient and therefore better compliance to normal oral hygiene procedures.
Collapse
|
25
|
Teeth whitening with 6% hydrogen peroxide and its impact on quality of life: 2 years of follow-up. Odontology 2018; 107:118-125. [DOI: 10.1007/s10266-018-0372-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 06/19/2018] [Indexed: 12/21/2022]
|