1
|
Marot M, Elter A, Mann P, Schwahofer A, Lang C, Johnen W, Körber SA, Beuthien-Baumann B, Gillmann C. Technical Note: On the feasibility of performing dosimetry in target and organ at risk using polymer dosimetry gel and thermoluminescence detectors in an anthropomorphic, deformable, and multimodal pelvis phantom. Med Phys 2021; 48:5501-5510. [PMID: 34260079 DOI: 10.1002/mp.15096] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 05/28/2021] [Accepted: 06/25/2021] [Indexed: 11/08/2022] Open
Abstract
OBJECTIVE To assess the feasibility of performing dose measurements in the target (prostate) and an adjacent organ at risk (rectum) using polymer dosimetry gel and thermoluminescence detectors (TLDs) in an anthropomorphic, deformable, and multimodal pelvis phantom (ADAM PETer). METHODS The 3D printed prostate organ surrogate of the ADAM PETer phantom was filled with polymer dosimetry gel. Nine TLD600 (LiF:Mg,Ti) were installed in 3 × 3 rows on a specifically designed 3D-printed TLD holder. The TLD holder was inserted into the rectum at the level of the prostate and fixed by a partially inflated endorectal balloon. Computed tomography (CT) images were taken and treatment planning was performed. A prescribed dose of 4.5 Gy was delivered to the planning target volume (PTV). The doses measured by the dosimetry gel in the prostate and the TLDs in the rectum ("measured dose") were compared to the doses calculated by the treatment planning system ("planned dose") on a voxel-by-voxel basis. RESULTS In the prostate organ surrogate, the 3D-γ-index was 97.7% for the 3% dose difference and 3 mm distance to agreement criterium. In the center of the prostate organ surrogate, measured and planned doses showed only minor deviations (<0.1 Gy, corresponding to a percentage error of 2.22%). On the edges of the prostate, slight differences between planned and measured doses were detected with a maximum deviation of 0.24 Gy, corresponding to 5.3% of the prescribed dose. The difference between planned and measured doses in the TLDs was on average 0.08 Gy (range: 0.02-0.21 Gy), corresponding to 1.78% of the prescribed dose (range: 0.44%-4.67%). CONCLUSIONS The present study demonstrates the feasibility of using polymer dosimetry gel and TLDs for 3D and 1D dose measurements in the prostate and the rectum organ surrogates in an anthropomorphic, deformable and multimodal phantom. The described methodology might offer new perspectives for end-to-end tests in image-guided adaptive radiotherapy workflows.
Collapse
Affiliation(s)
- Mathieu Marot
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Medicine, University of Heidelberg, Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Alina Elter
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.,Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Philipp Mann
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.,HQ-Imaging GmbH, Heidelberg, Germany
| | - Andrea Schwahofer
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Clemens Lang
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Wibke Johnen
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Stefan A Körber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Bettina Beuthien-Baumann
- Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Clarissa Gillmann
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| |
Collapse
|
2
|
Garcia J, Compte A, Galan C, Cozar M, Buxeda M, Mourelo S, Piñeiro T, Soler M, Valls E, Bassa P, Santabarbara J. 18F-choline PET/MR in the initial staging of prostate cancer. Impact on the therapeutic approach. Rev Esp Med Nucl Imagen Mol 2021. [DOI: 10.1016/j.remnie.2020.10.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
3
|
18F-choline PET/MRI on initial staging of prostate cancer. Impact on therapy approach. Rev Esp Med Nucl Imagen Mol 2021; 40:72-81. [PMID: 33579662 DOI: 10.1016/j.remn.2020.10.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 09/25/2020] [Accepted: 10/12/2020] [Indexed: 11/20/2022]
Abstract
AIM Evaluate the therapy impact of initial staging in patients diagnosed with prostate cancer by 18 F-choline PET/MRI hybrid technique. MATERIAL A prospective study which included 31 patients diagnosed with prostate cancer; Gleason > 7; mean PSA 13.6 ng/mL (range 6.3-20.6). PET/MRI studies were acquired simultaneously with hybrid equipment (SIGNA.3T, GE) following intravenous injection of 185 ± 18.5MBq of 18F-choline: - Early/prostate imaging: PET emission + multiparametric MR: DIXON-T1-T2-diffusion-gadolinium. - Late/whole-body imaging: PET emission + MR: DIXON-T1-T2-diffusion-STIR sequences. Images were visually evaluated. SUV & ADC & textures were also calculated. Treatment selection was based upon Oncology Committee consensus decision. RESULTS Procedure was well tolerated in all patients, and no artifacts were reported. MRI was superior in T staging in eight patients (25.8%) (Likert: 2-3), whereas PET increased MRI sensitivity in three patients (9.7%) (PIRADS: 3). PROSTATE LESION LOCATION Peripheral 91.4%, transitional 8.6%. SUVmax threshold: 2.95: sensitivity 92.9%, specificity 66.7%. No correlation SUV vs. ADC. Better distinction between stage T2 vs. T3 using the DiscrLin model with NG = 16 (AUC 0.7767 ± 0.3386). PET was superior to T2 in textures analysis (0.588 vs. 0.412). Seventeen patients (54.8%) were staged ≥ T3, with surgical treatment being contraindicated. Fifteen patients (48.4%) presented with extra-prostatic disease: 8/31 oligometastatic and 7/31 multiple metastasis. Therapy approach following PET/MRI was: radical treatment in 24/31 patients (77.4%), 14 radical prostatectomy and 10 MRI-guided radiotherapy; systemic treatment in 7/31 patients (22.6%). CONCLUSION 18F-choline PET/MRI had a complementary role for the T staging, with a high detection rate for NM infiltration. PET/MRI findings allowed patients to be directed either to prostatectomy or MRI-guided radiotherapy, and thus avoiding radicaltreatment in 22.6% of patients.
Collapse
|
4
|
Abstract
The progressive integration of positron emission tomography/computed tomography (PET/CT) imaging in radiation therapy has its rationale in the biological intertumoral and intratumoral heterogeneity of malignant lesions that require the individual adjustment of radiation dose to obtain an effective local tumor control in cancer patients. PET/CT provides information on the biological features of tumor lesions such as metabolism, hypoxia, and proliferation that can identify radioresistant regions and be exploited to optimize treatment plans. Here, we provide an overview of the basic principles of PET-based target volume selection and definition using 18F-fluorodeoxyglucose (18F-FDG) and then we focus on the emerging strategies of dose painting and adaptive radiotherapy using different tracers. Previous studies provided consistent evidence that integration of 18F-FDG PET/CT in radiotherapy planning improves delineation of target volumes and reduces the uncertainties and variabilities of anatomical delineation of tumor sites. PET-based dose painting and adaptive radiotherapy are feasible strategies although their clinical implementation is highly demanding and requires strong technical, computational, and logistic efforts. Further prospective clinical trials evaluating local tumor control, survival, and toxicity of these emerging strategies will promote the full integration of PET/CT in radiation oncology.
Collapse
Affiliation(s)
- Rosa Fonti
- Institute of Biostructures and Bioimages, National Research Council, Naples, Italy
| | - Manuel Conson
- Department of Advanced Biomedical Sciences, University of Naples "Federico II", Naples, Italy
| | - Silvana Del Vecchio
- Department of Advanced Biomedical Sciences, University of Naples "Federico II", Naples, Italy.
| |
Collapse
|