1
|
Reiffel JA. Selected Advances in the Anti-arrhythmic Management of Atrial Fibrillation: 2023. J Innov Card Rhythm Manag 2024; 15:5728-5734. [PMID: 38304092 PMCID: PMC10829416 DOI: 10.19102/icrm.2024.15014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2024] Open
|
2
|
Boriani G, Imberti JF, Leyva F, Casado-Arroyo R, Chun J, Braunschweig F, Zylla MM, Duncker D, Farkowski MM, Pürerfellner H, Merino JL. Length of hospital stay for elective electrophysiological procedures: a survey from the European Heart Rhythm Association. Europace 2023; 25:euad297. [PMID: 37789664 PMCID: PMC10563655 DOI: 10.1093/europace/euad297] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 09/24/2023] [Indexed: 10/05/2023] Open
Abstract
AIMS Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.
Collapse
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo, 71, Modena 41124, Italy
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
| | - Jacopo F Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo, 71, Modena 41124, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Francisco Leyva
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Cardiology, Aston Medical Research Institute, Aston Medical School, Aston University, Aston Triangle, Birmingham B4 7ET, UK
| | - Ruben Casado-Arroyo
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Cardiology, H.U.B.-Hôpital Erasme, Université Libre de Bruxelles, Brussels 1070, Belgium
| | - Julian Chun
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Frieder Braunschweig
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Medicine; Solna, Karolinska Institutet and ME Cardiology, Karolinska University Hospital, Norrbacka S1:02, Eugeniavagen 27, Stockholm 171 77, Sweden
| | - Maura M Zylla
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
| | - David Duncker
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover 30625, Germany
| | - Michał M Farkowski
- Department of Cardiology, Ministry of Interior and Administration National Medical Institute, Warsaw, Poland
| | - Helmut Pürerfellner
- Ordensklinikum Linz Elisabethinen, Interne II/Kardiologie und Interne Intensivmedizin, Fadingerstraße 1, 4020 Linz, Austria
| | - José L Merino
- Arrhythmia-Robotic Electrophysiology Unit, La Paz University Hospital, IdiPAZ, Universidad Autonoma, Madrid, Spain
| |
Collapse
|
3
|
AlKassas A, Fouda M, Fassini G, Sanhoury M. Pre-procedural high serum visfatin and tumor necrosis factor-α might predict recurrent atrial fibrillation after catheter ablation. Egypt Heart J 2023; 75:63. [PMID: 37466800 DOI: 10.1186/s43044-023-00383-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 06/25/2023] [Indexed: 07/20/2023] Open
Abstract
BACKGROUND Many patients would require repeated ablation procedures owing to recurrent atrial fibrillation with its associated symptoms. Identifying those who are at risk of recurrent AF could assist us to develop preventive strategies and to properly select those who will benefit more from catheter ablation. Our aim is to study the role of preprocedural serum level of certain biomarkers in the prediction of AF recurrence after catheter ablation. RESULTS The present study included 117 patients: 26 patients with persistent and 91 patients with paroxysmal AF. Blood samples for estimation of serum levels of studied cytokines were obtained prior to the procedure. Pulmonary vein isolation was performed in all patients through point-by point radiofrequency ablation guided by 3D electroanatomical mapping system. Patients were followed for 12 months for AF recurrence. Forty-one (35%) patients developed AF recurrence. Those patients were significantly older, had significantly higher BMI, lower ejection fraction, and wider maximal left atrial diameter (LAD). Serum hs-CRP, IL-6, TNF-α, visfatin, and adiponectin levels were significantly higher compared to those who did not develop AF recurrence. Correlation analysis showed positive correlations between the incidence of RAF and patients' age, BMI, and maximum LAD and elevated cytokine levels and maximal LAD showed significant correlations with the type of AF and elevated serum TNF-α, visfatin, and adiponectin. Statistical analyses defined elevated serum levels of TNF-α, visfatin, and adiponectin as positive predictors for RAF, and automatic linear modeling analysis showed that elevated serum visfatin, TNF-α, and adiponectin can predict RAF by accuracy rates of 50%, 34%, and 16%, respectively. CONCLUSIONS RAF is most probably an outcome of the interplay between patients' clinical data, obesity, and inflammation. Pre-procedural estimation of serum levels of visfatin and TNF-α might determine patients with probability for RAF.
Collapse
Affiliation(s)
- Amr AlKassas
- Cardiology Department, Faculty of Medicine, Tanta University, Tanta, Egypt
| | - Mohamed Fouda
- Clinical Pathology Department, Faculty of Medicine, Tanta University, Tanta, Egypt
| | - Gaetano Fassini
- Cardiac Arrhythmia Research Centre, Department of Cardiovascular Sciences, Centro Cardiologico Monzino, University of Milan, Milan, Italy
| | - Mohamed Sanhoury
- Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt.
| |
Collapse
|
4
|
Cecchini F, Mugnai G, Kazawa S, Bolzan B, Iacopino S, Maj R, Placentino F, Ribichini F, Sieira J, Sofianos D, Sorgente A, Tomasi L, de Asmundis C, Chierchia GB. Cryoballoon ablation for atrial fibrillation in octogenarians: a propensity score-based analysis with a younger cohort. J Cardiovasc Med (Hagerstown) 2023; 24:441-452. [PMID: 37285275 DOI: 10.2459/jcm.0000000000001486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
BACKGROUND In terms of safety and efficacy, cryoballoon ablation (CB-A) has become a valid option for achieving pulmonary vein isolation (PVI) in patients affected by symptomatic atrial fibrillation. However, CB-A data in octogenarians are still scarce and limited to single-centre experiences. The present multicentre study aimed to compare the outcomes and complications of index CB-A in patients older than 80 years with a cohort of younger patients. METHODS AND RESULTS We retrospectively enrolled 97 consecutive patients aged ≥80 years who underwent PVI using the second-generation CB-A. This group was compared with a younger cohort of patients using a 1:1 propensity score matching. After the matching, 70 patients from the elderly group were analysed and compared with 70 younger patients (control group). The mean age was 81.4 ± 1.9 years among octogenarians and 65.2 ± 10.2 years in the younger cohort. The global success rate after a median follow-up of 23 [18-32.5] months was 60.0% in the elderly group and 71.4% in the control group (P = 0.17). Phrenic nerve palsy was the most common complication occurring in a total of 11 patients (7.9%): in 6 (8.6%) patients in the elderly group and in 5 patients (7.1%) in the younger group (P = 0.51). Only two (1.4%) major complications occurred: one (1.4%) femoral artery pseudoaneurysm in the control group, which resolved with a tight groin bandage, and one (1.4%) case of urosepsis in the elderly group. Arrhythmia recurrence during the blanking period and the need for electrical cardioversion to restore sinus rhythm after PVI were found to be the only independent predictors of late arrhythmia relapses. CONCLUSIONS The present study showed that CB-A PVI is as feasible, safe and effective among appropriately selected octogenarians as it is in younger patients.
Collapse
Affiliation(s)
- Federico Cecchini
- Electrophysiology Unit, Maria Cecilia Hospital, Cotignola, RA, Italy
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Giacomo Mugnai
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Shuichiro Kazawa
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Bruna Bolzan
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Saverio Iacopino
- Electrophysiology Unit, Maria Cecilia Hospital, Cotignola, RA, Italy
| | - Riccardo Maj
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | | | - Flavio Ribichini
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Juan Sieira
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Dimitrios Sofianos
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Luca Tomasi
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Carlo de Asmundis
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| |
Collapse
|
5
|
Zucchelli G, Chun KRJ, Khelae SK, Földesi C, Kueffer FJ, van Bragt KA, Scazzuso F, On YK, Al-Kandari F, Okumura K. Impact of first-line cryoablation for atrial fibrillation on healthcare utilization, arrhythmia disease burden and efficacy outcomes: real-world evidence from the Cryo Global Registry. J Interv Card Electrophysiol 2023; 66:711-722. [PMID: 36331681 DOI: 10.1007/s10840-022-01388-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 09/29/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Cryoballoon ablation (CBA) is an effective first-line treatment for symptomatic atrial fibrillation (AF), as recently demonstrated by three randomized trials. This sub-analysis of the Cryo Global Registry aims to examine current clinical practices of first-line CBA. METHODS AF patients treated with first-line CBA were compared to CBA in antiarrhythmic drug (AAD)-refractory patients at 12 months. Efficacy was examined using time-to-first atrial arrhythmia recurrence following a 90-day blanking period. Healthcare utilization was evaluated by repeat ablations and hospitalizations. Disease burden was examined by assessing quality of life (QOL) and patients' reporting of symptoms. RESULTS Of 1394 patients, 433 (31.1%) were treated with first-line CBA, which was more frequent in high-volume centers. Serious procedure-related adverse event rates were similar. Efficacy at 12 months was higher in the first-line group (87.8 vs. 81.6%, HRunadj 0.64 (95% CI 0.47-0.88); p < 0.01) regardless of the centers' CBA experience; when controlling for baseline characteristics, the difference was not significant (HRadj 0.87 (95% CI 0.56-1.37); p = 0.55). No difference was observed in repeat ablations and hospitalizations between cohorts. First-line patients experienced a larger mean reduction in symptoms and were prescribed AADs at a lower rate at 12-month follow-up (9.7 vs. 29.9%). QOL improved in both cohorts from baseline to 12 months with no significant difference between groups (p = 0.29). CONCLUSIONS In this global real-world experience, first-line CBA in patients with symptomatic AF is effective, with a larger symptom reduction compared with CBA after AAD failure and without a difference in healthcare utilization at mid-term follow-up. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov/ct2/show/NCT02752737.
Collapse
Affiliation(s)
- Giulio Zucchelli
- Second Division of Cardiology, Azienda Ospedaliero Universitaria Pisana, Via Roma, 67, 56126, Pisa, Italy.
| | | | | | - Csaba Földesi
- Gottsegen György Országos Kardiovaszkuláris Intézet, Budapest, Hungary
| | | | | | | | - Young-Keun On
- Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | | | - Ken Okumura
- Saiseikai Kumamoto Hospital, Kumamoto, Japan
| |
Collapse
|
6
|
Boriani G, Bonini N, Imberti JF, Vitolo M. New Perspectives on Risk Stratification and Treatment in Patients with Atrial Fibrillation: An Analysis of Recent Contributions on the Journal of Cardiovascular Disease and Development. J Cardiovasc Dev Dis 2023; 10:61. [PMID: 36826557 PMCID: PMC9965336 DOI: 10.3390/jcdd10020061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 01/10/2023] [Accepted: 01/16/2023] [Indexed: 02/05/2023] Open
Abstract
The medical approach to atrial fibrillation (AF) underwent a paradigm shift over time, evolving from considering AF as a simple arrhythmic phenomenon to a complex nosological entity [...].
Collapse
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| | - Niccolò Bonini
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41124 Modena, Italy
| | - Jacopo Francesco Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41124 Modena, Italy
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41124 Modena, Italy
| |
Collapse
|
7
|
Boriani G, Imberti JF, Vitolo M. Dronedarone in the treatment of atrial fibrillation with concomitant heart failure and preserved or mildly reduced ejection fraction: closer to Ithaca after a long Odyssey? Eur J Heart Fail 2022; 24:1102-1105. [PMID: 35481867 DOI: 10.1002/ejhf.2519] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 04/22/2022] [Indexed: 11/05/2022] Open
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Jacopo Francesco Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom
| |
Collapse
|
8
|
Boriani G, Iacopino S, Arena G, Pieragnoli P, Verlato R, Manfrin M, Molon G, Rovaris G, Curnis A, Perego GB, Dello Russo A, Landolina M, Vitolo M, Tondo C. Chronic Kidney Disease with Mild and Mild to Moderate Reduction in Renal Function and Long-Term Recurrences of Atrial Fibrillation after Pulmonary Vein Cryoballoon Ablation. J Cardiovasc Dev Dis 2022; 9:126. [PMID: 35621837 PMCID: PMC9147782 DOI: 10.3390/jcdd9050126] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 04/01/2022] [Accepted: 04/14/2022] [Indexed: 02/01/2023] Open
Abstract
The aim of this research was to evaluate if patients with chronic kidney disease (CKD) and mild or mild to moderate depression of renal function have an increased risk of atrial fibrillation (AF) recurrences after cryoballoon (CB) ablation. We performed a retrospective analysis of AF patients undergoing pulmonary vein isolation (PVI) by CB. The cohort was divided according to the KDIGO CKD-EPI classification into a (1) normal, (2) mildly decreased, or (3) mild to moderate reduction in estimated glomerular filtration rate (eGFR). Freedom from AF recurrences was the primary endpoint. A total of 1971 patients were included (60 ± 10 years, 29.0% females, 73.6% paroxysmal AF) in the study. Acute success and complication rates were 99.2% and 3.7%, respectively, with no significant differences among the three groups. After a follow-up of 24 months, AF recurrences were higher in the mildly and mild to moderate CKD groups compared to the normal kidney function group (23.4% vs. 28.3% vs. 33.5%, p < 0.05). Mild to moderate CKD was an independent predictor of AF recurrences after the blanking period (hazard ratio:1.38, 95% CI 1.02−1.86, p = 0.037). In conclusion, a multicenter analysis of AF patients treated with cryoablation revealed mild to moderate reductions in renal functions were associated with a higher risk of AF recurrences. Conversely, the procedural success and complication rates were similar in patients with normal, mildly reduced, or mild to moderate reduction in eGFR.
Collapse
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41121 Modena, Italy;
| | - Saverio Iacopino
- Electrophysiology Unit, Maria Cecilia Hospital, GVM Care & Research, 48033 Cotignola, Italy;
| | | | | | - Roberto Verlato
- ULSS 6 Euganea, Ospedale di Camposampiero-Cittadella, 35013 Cittadella, Italy;
| | | | - Giulio Molon
- IRCCS Sacro Cuore don Calabria, 37024 Negrar, Italy;
| | | | | | | | | | | | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41121 Modena, Italy;
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41121 Modena, Italy
| | - Claudio Tondo
- Department of Clinical Electrophysiology & Cardiac Pacing, Heart Rhythm Center, Monzino Cardiac Center IRCCS, 20122 Milan, Italy;
- Department of Biochemical, Surgical and Dentist Sciences, University of Milan, 20122 Milan, Italy
| | | |
Collapse
|
9
|
Mugnai G, de Asmundis C, Sorgente A, Chierchia GB. Cryoballoon ablation as initial treatment for paroxysmal atrial fibrillation: time to change the standard approach? J Cardiovasc Med (Hagerstown) 2021; 22:624-625. [PMID: 34196624 DOI: 10.2459/jcm.0000000000001206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Giacomo Mugnai
- Heart Rhythm Management Center, UZ Brussel-VUB, Brussels, Belgium
| | | | | | | |
Collapse
|