1
|
Kopačin V, Brkić H, Ivković A, Kasabašić M, Knežević Ž, Majer M, Nodilo M, Turk T, Faj D. Development and validation of the low-cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy. J Appl Clin Med Phys 2024; 25:e14240. [PMID: 38150580 PMCID: PMC10860449 DOI: 10.1002/acm2.14240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/27/2023] [Accepted: 11/27/2023] [Indexed: 12/29/2023] Open
Abstract
BACKGROUND Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman. PURPOSE In this study, the development of a low-cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom. METHODS Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment. RESULTS Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%. CONCLUSIONS Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.
Collapse
Affiliation(s)
- Vjekoslav Kopačin
- Faculty of MedicineDepartment of RadiologyJ. J. Strossmayer University Osijek, University Hospital Center OsijekDepartment of Diagnostic and Interventional RadiologyOsijekCroatia
| | - Hrvoje Brkić
- Faculty of MedicineDepartment of Biophysics and Medical PhysicsJ. J. Strossmayer University OsijekOsijekCroatia
- Faculty of Dental Medicine and HealthDepartment of BiophysicsBiology and ChemistryJ. J. Strossmayer University OsijekOsijekCroatia
| | - Ana Ivković
- Faculty of MedicineDepartment of Biophysics and Medical PhysicsJ. J. Strossmayer University Osijek, University Hospital Center OsijekDepartment of Medical PhysicsOsijekCroatia
| | - Mladen Kasabašić
- Faculty of MedicineDepartment of Biophysics and Medical PhysicsJ. J. Strossmayer University Osijek, University Hospital Center OsijekDepartment of Medical PhysicsOsijekCroatia
| | - Željka Knežević
- Division of Materials ChemistryRuđer Bošković InstituteZagrebCroatia
| | - Marija Majer
- Division of Materials ChemistryRuđer Bošković InstituteZagrebCroatia
| | - Marijana Nodilo
- Division of Materials ChemistryRuđer Bošković InstituteZagrebCroatia
| | - Tajana Turk
- Faculty of MedicineDepartment of RadiologyJ. J. Strossmayer University Osijek, University Hospital Center OsijekDepartment of Diagnostic and Interventional RadiologyOsijekCroatia
| | - Dario Faj
- Faculty of MedicineDepartment of Biophysics and Medical PhysicsJ. J. Strossmayer University OsijekOsijekCroatia
- Faculty of Dental Medicine and HealthDepartment of BiophysicsBiology and ChemistryJ. J. Strossmayer University OsijekOsijekCroatia
| |
Collapse
|
2
|
Faj D, Bassinet C, Brkić H, De Monte F, Dreuil S, Dupont L, Ferrari P, Gallagher A, Gallo L, Huet C, Knežević Ž, Kralik I, Krstić D, Maccia C, Majer M, Malchair F, O'Connor U, Pankowski P, Sans Merce M, Sage J, Simantirakis G. Management of pregnant or potentially pregnant patients undergoing diagnostic and interventional radiology procedures: Investigation of clinical routine practice. Phys Med 2023; 115:103159. [PMID: 37852021 DOI: 10.1016/j.ejmp.2023.103159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 08/26/2023] [Accepted: 10/01/2023] [Indexed: 10/20/2023] Open
Abstract
It is well known that foetuses are highly sensitive to ionising radiation and special attention to justification and optimisation of radiological procedures involving a pregnant patient is required. A task to review, validate and compare different approaches to managing the pregnant patient and to estimating the associated foetal doses arising from a diagnostic or interventional radiology (DIR) procedure was designed in the framework of EURADOS working group 12. As a first step, a survey of radiation protection practice including dosimetry considerations among EURADOS members was performed using online questionnaire. Then, to evaluate the possible differences in the estimated foetal doses, a comparison of assessed dose values was made for three cases of pregnant patients that underwent different CT procedures. More than 120 professionals from 108 institutions and 17 countries that are involved in managing pregnant patients undergoing DIR procedures answered the questionnaire. Most of the respondents use national or hospital guidelines on the management of pregnant patients undergoing DIR procedures. However, the guidelines differ considerably among respondents. Comparison of foetal dose assessments performed by dosimetry experts showed the variety of methods used as well as large variability of estimated foetal doses in all three cases. Although European and International commission on radiation protection guidelines already exist, they are more than 20 years old and, in some aspects, they are obsolete. This paper shows that there is a need to revise and update these guidelines.
Collapse
Affiliation(s)
- Dario Faj
- Faculty of Medicine, J. J. Strossmayer University of Osijek, J. Huttlera 4, Osijek, Croatia; Faculty of Dental Medicine and Health, J. J. Strossmayer University of Osijek, Crkvena 21, Osijek, Croatia
| | - Céline Bassinet
- Institute for Radiation Protection and Nuclear Safety, 31 avenue de la division Leclerc, Fontenay-aux-Roses, France
| | - Hrvoje Brkić
- Faculty of Medicine, J. J. Strossmayer University of Osijek, J. Huttlera 4, Osijek, Croatia; Faculty of Dental Medicine and Health, J. J. Strossmayer University of Osijek, Crkvena 21, Osijek, Croatia.
| | | | - Serge Dreuil
- Institute for Radiation Protection and Nuclear Safety, 31 avenue de la division Leclerc, Fontenay-aux-Roses, France
| | - Laura Dupont
- University Hospital of Geneva, Geneva, Switzerland
| | | | | | - Lara Gallo
- Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
| | - Christelle Huet
- Institute for Radiation Protection and Nuclear Safety, 31 avenue de la division Leclerc, Fontenay-aux-Roses, France
| | | | - Ivana Kralik
- Dubrava University Hospital, Avenija Gojka Suska 6, Zagreb, Croatia
| | - Dragana Krstić
- University of Kragujevac, Faculty of Science, R. Domanovica 12, 34000 Kragujevac, Serbia
| | | | - Marija Majer
- Ruđer Boškovć Institute, Bijenička 54, Zagreb, Croatia
| | | | - Una O'Connor
- Medical Physics & Bioengineering Dept, St. James's Hospital, Dublin, Ireland
| | - Piotr Pankowski
- Faculty of Physics and Applied Informatics, University of Lodz, Pomorska St. 149/153, 90-236 Lodz, Poland
| | | | - Julie Sage
- Institute for Radiation Protection and Nuclear Safety, 31 avenue de la division Leclerc, Fontenay-aux-Roses, France
| | - George Simantirakis
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| |
Collapse
|