1
|
Kawakami S, Takahashi A, Taniguchi N, Yamada T, Hata T, Nakajima S, Saito S. Physiological Scaffold Remodeling in the Coronary Artery After 30 Months of Bioadaptor Implantation. JACC Case Rep 2025; 30:103089. [PMID: 40054935 PMCID: PMC11911838 DOI: 10.1016/j.jaccas.2024.103089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 10/31/2024] [Accepted: 11/08/2024] [Indexed: 03/20/2025]
Abstract
The DynamX Bioadaptor (Elixir Medical Corporation) is a novel coronary artery scaffold consisting of 3 helical strands connected by a bioabsorbable polymer. After 6 months, the polymer dissolves, restoring the physiological motion of the coronary artery as the interconnected (caged) structure of the scaffold disengages. Here we report the cases of 2 patients treated with the Bioadaptor who underwent intravascular imaging at the time of the index procedure and during follow-up periods of 30 and 36 months, respectively. The cross-sectional images of the scaffold were analyzed and compared with those obtained during the index procedure. At follow-up, the mean cross-sectional area of the scaffold was increased significantly in both cases, regardless of the degree of intimal hyperplasia. Such unique properties of the Bioadaptor make it a promising alternative to contemporary drug-eluting stents.
Collapse
Affiliation(s)
- Shiori Kawakami
- Department of Cardiology, Sakurakai Takahashi Hospital, Kobe, Japan
| | - Akihiko Takahashi
- Department of Cardiology, Sakurakai Takahashi Hospital, Kobe, Japan; Graduate School, Kobe Women's University, Kobe, Japan.
| | | | - Takeshi Yamada
- Department of Cardiology, Sakurakai Takahashi Hospital, Kobe, Japan
| | - Tetsuya Hata
- Department of Cardiology, Sakurakai Takahashi Hospital, Kobe, Japan
| | | | - Shigeru Saito
- Department of Cardiology, Shonan Kamakura General Hospital, Kamakura, Japan
| |
Collapse
|
2
|
Erlinge D, Andersson J, Fröbert O, Törnerud M, Hamid M, Kellerth T, Grimfjärd P, Winnberg O, Jurga J, Wagner H, Zwackman S, Adielsson M, Alström P, Masoe E, Ulvenstam A, Millgård J, Böhm F, Held C, Renlund H, Oldgren J, Smits PC, Elek C, Abizaid A, James S. Bioadaptor implant versus contemporary drug-eluting stent in percutaneous coronary interventions in Sweden (INFINITY-SWEDEHEART): a single-blind, non-inferiority, registry-based, randomised controlled trial. Lancet 2024; 404:1750-1759. [PMID: 39481425 DOI: 10.1016/s0140-6736(24)02227-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2024] [Revised: 10/07/2024] [Accepted: 10/07/2024] [Indexed: 11/02/2024]
Abstract
BACKGROUND Persistent non-plateauing adverse event rates in patients who underwent percutaneous coronary intervention (PCI) remain a challenge. A bioadaptor is a novel implant that addresses this issue by restoring the haemodynamic modulation of the artery, allowing cyclic pulsatility, vasomotion, and adaptative remodelling, by unlocking and providing dynamic support to the artery. We aimed to assess outcomes with the device versus a contemporary drug-eluting stent (DES) in a representative PCI population. METHODS INFINITY-SWEDEHEART is a single-blind, non-inferiority, registry-based, randomised controlled study conducted in 20 hospitals in Sweden. Patients aged 18-85 years, with chronic or acute coronary syndrome ischaemic heart disease, with an indication for PCI, with up to three de novo lesions suitable for implantation with one single device per lesion, and successful pre-dilatation were identified via the Swedish Coronary Angiography and Angioplasty Registry and eligible for enrolment. Participants were randomly assigned (1:1), using block randomisation with random variation in block size and stratified by site, to either the DynamX bioadaptor (Elixir Medical, Milpitas, CA, USA) or a zotarolimus-eluting DES (Resolute Onyx and Onyx Trustar, Medtronic, Minneapolis, MN, USA). The primary endpoint was the device-oriented clinical endpoint of target lesion failure at 12 months (a composite of cardiovascular death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation), assessed in the intention-to-treat (ITT) population (ie, all patients randomly assigned to treatment, regardless of treatment received) who had either experienced an event up to 12 months or completed the trial up to 12 months. Non-inferiority was established if the upper limit of the two-sided 95% CI for the absolute risk difference was less than 4·2%. Powered secondary endpoints were landmark analyses from 6 months onwards for target lesion failure, target vessel failure (composite of cardiovascular death, target vessel myocardial infarction, and ischaemia-driven target vessel revascularisation), and target lesion failure for patients with acute coronary syndrome assessed in the ITT population). This study is registered with ClinicalTrials.gov, NCT04562805, and follow-up to 5 years is ongoing. FINDINGS Between Sept 30, 2020, and July 11, 2023, 2399 patients were randomly assigned to receive the bioadaptor (n=1201) or DES (n=1198; ITT population). Median age was 69·5 years (IQR 61·2-75·6), 575 (24·0%) of 2399 patients were female, and 1824 (76·0%) were male (data on race and ethnicity were not collected), and 1838 (76·6%) patients presented with acute coronary syndrome. The primary endpoint of 12-month target lesion failure occurred in 28 (2·4%) of 1189 assessable patients in the bioadaptor group versus 33 (2·8%) of 1192 assessable patients in the DES group, with a risk difference of -0·41% (95% CI -1·94 to 1·11; pnon-inferiority<0·0001). In the prespecified landmark analysis from 6 months to 12 months, the Kaplan-Meier estimates of target lesion failure were 0·3% (with events in three of 1170 patients) in the bioadaptor group versus 1·7% (with events in 16 of 1176 patients) in the DES group (hazard ratio 0·19 [95% CI 0·06 to 0·65]; p=0·0079), of target vessel failure were 0·8% (events in eight of 1167) versus 2·5% (events in 23 of 1174; 0·35 [0·16 to 0·79]; p=0·011), and of target lesion failure in patients with acute coronary syndrome were 0·3% (events in two of 906) versus 1·8% (events in 12 of 895; 0·17 [0·04 to 0·74]; p=0·018). The rate of definite or probable device thrombosis, which was recorded as a safety outcome, was low and did not differ between groups (eight [0·7%] of 1201 in the bioadaptor group vs six [0·5%] of 1198 in the DES group; difference in event rates of 0·16% [95% CI -0·50 to 0·83]). INTERPRETATION Among patients with coronary artery disease, including those with acute coronary syndrome, treatment with the bioadaptor was non-inferior to contemporary DES, showing potential to mitigate non-plateauing device-related events and improving outcomes in patients undergoing PCI. The additional planned follow-up will help to reinforce the clinical significance of the 1-year findings. FUNDING Elixir Medical.
Collapse
Affiliation(s)
- David Erlinge
- Department of Cardiology, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden.
| | | | - Ole Fröbert
- Department of Cardiology, Faculty of Health, Örebro University, Örebro, Sweden; Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, Denmark
| | - Mattias Törnerud
- Department of Cardiology, Karolinska Institute and Danderyd Hospital, Stockholm, Sweden
| | - Mehmet Hamid
- Department of Cardiology, Mälarsjukhuset, Eskilstuna, Sweden
| | - Thomas Kellerth
- Department of Cardiology, Central Hospital, Karlstad, Sweden
| | - Per Grimfjärd
- Department of Cardiology, Västerås Hospital, Västerås, Sweden; Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden
| | - Oscar Winnberg
- Department of Clinical Science and Education, Södersjukhuset, Karolinska Institute, Stockholm, Sweden; Department of Cardiology, Capio St Göran's Hospital, Stockholm, Sweden
| | - Juliane Jurga
- Department of Cardiology, Karolinska Institutet and Karolinska University Hospital, Stockholm, Sweden
| | - Henrik Wagner
- Department of Cardiology, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden; Department of Cardiology, Helsingborg Lasarett, Helsingborg, Sweden
| | - Sammy Zwackman
- Department of Health, Medicine and Caring Sciences and Department of Cardiology, Linköping University, Linköping, Sweden
| | | | - Patrik Alström
- Department of Clinical Science and Education, Division of Cardiology, Södersjukhuset, Karolinska Institutet, Stockholm, Sweden
| | - Elli Masoe
- Department of Cardiology, Sundsvall Hospital, Sundsvall, Sweden
| | | | - Jonas Millgård
- Department of Cardiology, Sunderby Hospital, Luleå, Sweden
| | - Felix Böhm
- Department of Cardiology, Karolinska Institute and Danderyd Hospital, Stockholm, Sweden
| | - Claes Held
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden; Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| | - Henrik Renlund
- Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| | - Jonas Oldgren
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden; Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| | - Pieter C Smits
- European Cardiovascular Research Center (CERC), Massy, France
| | | | | | - Stefan James
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden; Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| |
Collapse
|
4
|
Saito S, Bennett J, Nef HM, Webster M, Namiki A, Takahashi A, Kakuta T, Yamazaki S, Shibata Y, Scott D, Vrolix M, Menon M, Möllmann H, Werner N, Neylon A, Mehmedbegovic Z, Smits PC, Morice MC, Verheye S. First randomised controlled trial comparing the sirolimus-eluting bioadaptor with the zotarolimus-eluting drug-eluting stent in patients with de novo coronary artery lesions: 12-month clinical and imaging data from the multi-centre, international, BIODAPTOR-RCT. EClinicalMedicine 2023; 65:102304. [PMID: 38106564 PMCID: PMC10725075 DOI: 10.1016/j.eclinm.2023.102304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 10/10/2023] [Accepted: 10/13/2023] [Indexed: 12/19/2023] Open
Abstract
Background The DynamX™ bioadaptor is the first coronary implant technology with a unique mechanism of unlocking the bioadaptor frame after polymer resorption over 6 months, uncaging the vessel while maintaining a dynamic support to the vessel. It aims to achieve the acute performance of drug-eluting stents (DES) with the advantages of restoration of vessel function. Methods This international, single blinded, randomised controlled (1:1) trial compared a sirolimus-eluting bioadaptor with a contemporary zotarolimus-eluting stent (DES) in 34 hospitals in Europe, Japan and New Zealand. Patients with de novo coronary lesions and absence of acute myocardial infarction were enrolled from January 2021 to Feburary 2022. The implantation of the bioadaptor followed the standards of DES. An imaging subset of 100 patients had angiographic and intravascular ultrasound assessments, and 20 patients additionally optical coherence tomography. Data collection will continue through 5 years, we herein report 12-month data based on an intention-to-treat population. This trial is registered at ClinicalTrials.gov (NCT04192747). Findings 445 patients were randomised between January 2021 and February 2022. Device, lesion and procedural success rates, and acute gain were similar amongst the groups. The primary endpoint, 12-month target lesion failure, was 1.8% [95% CI: 0.5; 4.6] (n = 4) versus 2.8% [95% CI: 1.0; 6.0] (n = 6), pnon-inferiority < 0.001 for the bioadaptor and the DES, respectively (Δ-1.0% [95% CI: -3.3; 1.4]). One definite or probable device thrombosis occurred in each group. The 12-month imaging endpoints showed superior effectiveness of the bioadaptor such as in-device late lumen loss (0.09 mm [SD 0.34] versus 0.25 mm [SD 0.39], p = 0.04), and restored compliance and cyclic pulsatility (%mid in-device lumen area change of 7.5% versus 2.7%, p < 0.001). Interpretation This is the first randomised controlled trial comparing the novel bioadaptor technology against a contemporary DES. The bioadaptor demonstrated similar acute performance and 12-month clinical outcomes, and superior imaging endpoints including restoration of vessel function. Funding The study was funded by Elixir Medical.
Collapse
Affiliation(s)
- Shigeru Saito
- Heart Center, Iryohojin Tokushukai Shonan Kamakura General Hospital, Kamakura City, Japan
| | - Johan Bennett
- Department of Cardiovascular Medicine, UZ Leuven, Leuven, Belgium
| | - Holger M. Nef
- Department of Cardiology and Angiology, University of Giessen, Giessen, Germany
| | - Mark Webster
- Cardiac Investigation Unit, Auckland City Hospital, Auckland, New Zealand
| | - Atsuo Namiki
- Department of Cardiology, Kanto Rosai Hospital, Nakahara-ku, Kawasaki-shi, Japan
| | | | - Tsunekazu Kakuta
- Cardiovascular Medicine, Tsuchiura Kyodo Hospital, Tsuchiura City, Japan
| | - Seiji Yamazaki
- Department of Cardiology, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Yoshisato Shibata
- Department of Cardiology, Miyazaki Medical Association Hospital, Miyazaki City, Japan
| | - Douglas Scott
- Department of Cardiology, Middlemore Hospital, Auckland, New Zealand
| | - Mathias Vrolix
- Department of Cardiology, Ziekenhuis Oost-Limburg, Campus Sint Jan, Genk, Belgium
| | - Madhav Menon
- Department of Cardiology, Waikato Hospital, Hamilton, New Zealand
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital Dortmund, Dortmund, Germany
| | - Nikos Werner
- Department of Cardiology, Krankenhaus der Barmherzigen Brüder Trier, Trier, Germany
| | - Antoinette Neylon
- CERC (Cardiovascular European Research Center) ICPS Ramsay, Massy, France
| | | | - Pieter C. Smits
- CERC (Cardiovascular European Research Center) ICPS Ramsay, Massy, France
| | | | - Stefan Verheye
- Interventional Cardiology, ZNA Cardiovascular Center Middelheim, Antwerp, Belgium
| | - BIOADAPTOR-RCT Collaborators
- Heart Center, Iryohojin Tokushukai Shonan Kamakura General Hospital, Kamakura City, Japan
- Department of Cardiovascular Medicine, UZ Leuven, Leuven, Belgium
- Department of Cardiology and Angiology, University of Giessen, Giessen, Germany
- Cardiac Investigation Unit, Auckland City Hospital, Auckland, New Zealand
- Department of Cardiology, Kanto Rosai Hospital, Nakahara-ku, Kawasaki-shi, Japan
- Department of Cardiology, Takahashi Hospital, Kobe City, Japan
- Cardiovascular Medicine, Tsuchiura Kyodo Hospital, Tsuchiura City, Japan
- Department of Cardiology, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
- Department of Cardiology, Miyazaki Medical Association Hospital, Miyazaki City, Japan
- Department of Cardiology, Middlemore Hospital, Auckland, New Zealand
- Department of Cardiology, Ziekenhuis Oost-Limburg, Campus Sint Jan, Genk, Belgium
- Department of Cardiology, Waikato Hospital, Hamilton, New Zealand
- Department of Cardiology, St. Johannes Hospital Dortmund, Dortmund, Germany
- Department of Cardiology, Krankenhaus der Barmherzigen Brüder Trier, Trier, Germany
- CERC (Cardiovascular European Research Center) ICPS Ramsay, Massy, France
- Interventional Cardiology, ZNA Cardiovascular Center Middelheim, Antwerp, Belgium
| |
Collapse
|