Riveline JP, Teynie J, Belmouaz S, Franc S, Dardari D, Bauwens M, Caudwell V, Ragot S, Bridoux F, Charpentier G, Marechaud R, Hadjadj S. Glycaemic control in type 2 diabetic patients on chronic haemodialysis: use of a continuous glucose monitoring system.
Nephrol Dial Transplant 2009;
24:2866-71. [PMID:
19389864 DOI:
10.1093/ndt/gfp181]
[Citation(s) in RCA: 86] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND
The proportion of diabetic patients undergoing haemodialysis is rapidly increasing. Glucose control among such patients is difficult to assess. We aimed to evaluate the clinical performance of a continuous glucose monitoring system (CGMS) in type 2 diabetic patients on chronic haemodialysis.
METHODS
We used a 4-day CGMS to monitor glucose levels in 19 haemodialysed type 2 diabetic patients (HD T2) including 2 days with and 2 days without dialysis session, and 39 non-HD T2 in a double-centre study.
RESULTS
The glucose concentration according to the glucose meter and CGMS were correlated in HD T2 patients (r = 0.90, P < 0.0001) and in non-HD T2 patients (r = 0.81, P < 0.0001). The relative absolute difference (RAD) between glucose determined by a glucose meter and glucose determined by the CGMS did not differ between HD T2 and non-HD T2 patients (9.2 +/- 10.5 vs. 8.2 +/- 7.6%; P = 0.165). Glycated haemoglobin (A1c) and mean glucose concentration were strongly correlated in non-HD T2 patients (r = 0.71; P < 0.0001) but weakly correlated in HD T2 patients (r = 0.47; P = 0.042). Fructosamine was correlated with the mean glucose concentration in non-HD T2 (r = 0.67; P < 0.0001) but not in HD T2 patients (r = 0.04; P = 0.88).
CONCLUSION
CGM is a validated marker of glycaemic control in HD diabetic patients. This tool showed that A1c and fructosamine, despite being good markers of glycaemic control in non-HD diabetic patients, are of poor value in HD diabetic patients.
Collapse