1
|
Koori N, Yoshida Y, Noda A, Maeda A, Nishikawa F, Yasui M, Kurata K, Suzuki Y, Kamekawa H, Nishikawa H. [Effectiveness of Radiological Technologists in Reporting Computed Tomography Findings in After-hour Emergencies]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:582-592. [PMID: 35569957 DOI: 10.6009/jjrt.2022-1230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE This study investigated the effectiveness of assistive work of radiological technologists (RTs) in conducting computed tomography (CT)/magnetic resonance imaging (MRI) during emergencies. METHODS In total, 2681 examinations in 2294 patients who underwent CT or MRI during our after-hours clinic hours were conducted. The emergency of the diseases was classified into three categories: emergency diseases, semi-emergency diseases, and non-emergency diseases. The reading report of the RTs group, resident physicians (RPs) group, and senior physicians (SPs) group were used to calculate the sensitivity, specificity, and accuracy. RESULTS The RTs group had an accuracy of 87.0% for emergency and semi-emergency diseases. The sensitivity of the combined RTs/RPs/SPs group was higher than that of the RPs and SPs group alone. CONCLUSION After-hours help from RTs for emergency and semi-emergency diseases enhanced sensitivity and thus demonstrated the effectiveness in emergency care.
Collapse
Affiliation(s)
- Norikazu Koori
- Department of Radiology, Komaki City Hospital.,Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University
| | | | - Akari Noda
- Department of Radiology, Komaki City Hospital
| | - Akiko Maeda
- Department of Radiology, Komaki City Hospital
| | | | | | | | | | | | | |
Collapse
|
2
|
Chhetri S, Pendem S, Bharath J, Priyanka. Low kilovoltage and low contrast volume neck CT protocol using iterative reconstruction techniques: A comparison with standard dose protocol. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2021.109935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
3
|
He C, Liu J, Hu S, Qing H, Luo H, Chen X, Liu Y, Zhou P. Improvement of image quality of laryngeal squamous cell carcinoma using noise-optimized virtual monoenergetic image and nonlinear blending image algorithms in dual-energy computed tomography. Head Neck 2021; 43:3125-3131. [PMID: 34268830 DOI: 10.1002/hed.26812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 04/20/2021] [Accepted: 07/07/2021] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Dual-energy computed tomography (DECT) has been used to improve image quality of head and neck squamous cell carcinoma (SCC). This study aimed to assess image quality of laryngeal SCC using linear blending image (LBI), nonlinear blending image (NBI), and noise-optimized virtual monoenergetic image (VMI+) algorithms. METHODS Thirty-four patients with laryngeal SCC were retrospectively enrolled between June 2019 and December 2020. DECT images were reconstructed using LBI (80 kV and M_0.6), NBI, and VMI+ (40 and 55 keV) algorithms. Contrast-to-noise ratio (CNR), tumor delineation, and overall image quality were assessed and compared. RESULTS VMI+ (40 keV) had the highest CNR and provided better tumor delineation than VMI+ (55 keV), LBI, and NBI, while NBI provided better overall image quality than VMI+ and LBI (all corrected p < 0.05). CONCLUSIONS VMI+ (40 keV) and NBI improve image quality of laryngeal SCC and may be preferable in DECT examination.
Collapse
Affiliation(s)
- Changjiu He
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Jieke Liu
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Shibei Hu
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Haomiao Qing
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Hongbing Luo
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Xiaoli Chen
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Ying Liu
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Peng Zhou
- Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
4
|
Usefulness of Virtual Monochromatic Images and Iodine Maps Derived from Dual-Energy Computed Tomography for Diagnosing Deep Neck Abscesses. J Comput Assist Tomogr 2021; 45:625-628. [PMID: 34270481 DOI: 10.1097/rct.0000000000001188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE We aimed to determine whether dual-energy computed tomography (CT) is useful for evaluating deep neck abscesses. METHODS This study included 22 consecutive patients who were clinically suspected of having a deep neck abscess and underwent dual-energy CT. Conventional 120-kVp images, 70- and 40-keV virtual monochromatic images (VMIs), and iodine maps were inspected to calculate the contrast ratio of the abscess rim (AR) to the abscess center (AC) or to the adjacent muscle (M). The diagnostic certainty of abscesses was assessed on these images. RESULTS Twenty (91%) of 22 patients had a definitive diagnosis. The contrast ratio for AR/AC and AR/M was significantly higher on 40-keV VMIs and iodine maps than on 120-kVp images and 70-keV VMIs (P < 0.05). On both 40-keV VMIs and iodine maps, the diagnostic certainty of abscess improved in 3 (15%) cases compared with 120-kVp images and 70-keV VMIs. CONCLUSIONS Dual-energy CT-based 40-keV VMIs and iodine maps are useful for evaluating deep neck abscesses and may improve diagnostic certainty.
Collapse
|
5
|
Yoo J, Lee JM, Yoon JH, Joo I, Lee ES, Jeon SK, Jang S. Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma. Abdom Radiol (NY) 2021; 46:3217-3226. [PMID: 33713160 DOI: 10.1007/s00261-020-02888-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 11/25/2020] [Accepted: 11/27/2020] [Indexed: 01/19/2023]
Abstract
PURPOSE To compare lesion conspicuity and image quality of arterial phase images obtained from low kVp (90-kVp) and dual-energy (DE) scans for the evaluation of hypervascular hepatocellular carcinoma (HCC). METHODS This retrospective study included 229 patients with HCC who underwent either 90 kVp (n = 106) or DE scan (80- and 150-kVp with a tin filter) (n = 123) during the arterial phase. DE scans were reconstructed into a linearly blended image with a mixed ratio of 0.6 (60% 80kVp and 40% 150 kVp) and post-processed for 40 keV and 50 keV images. The contrast-to-noise ratio (CNR) of HCC to the liver and image noise was measured. Lesion conspicuity, liver parenchymal image quality, and overall image preference were assessed qualitatively by three independent radiologists. RESULTS DE 40 keV images had the highest CNR of HCC, and DE blended images had the lowest image noise among four image sets (p = 0.01 and p < 0.001, respectively). There was no significant difference in mean volume CT dose index and dose-length product between DE and low kVp scan (ps > 0.05). For qualitative analyses, DE blended images had the highest scores for image quality and overall image preference (ps < 0.001). CONCLUSION At an equal radiation dose, DE 40 keV showed higher CNR of HCC and DE blended image showed higher image quality and image preference compared with low kVp CT.
Collapse
Affiliation(s)
- Jeongin Yoo
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Daehak-ro 101, Jongno-gu, Seoul, 03080, Korea.
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - Eun Sun Lee
- Department of Radiology, Chung-Ang University Hospital, Seoul, Korea
| | - Sun Kyung Jeon
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Siwon Jang
- Department of Radiology, Seoul National University Boramae Hospital, Seoul, Korea
| |
Collapse
|
6
|
Hsiao CC, Chen PC, Kuo PC, Ho CH, Jao JC. Assessment of image quality and dose in contrast-enhanced head and neck CT angiography of New Zealand rabbit. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020; 28:739-750. [PMID: 32597826 DOI: 10.3233/xst-200669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND Although computed tomography (CT) is a powerful diagnostic imaging modality for diagnosing vascular diseases, it is some what risky to human health due to the high radiation dosage. Thus, CT vendors have developed low dose computed tomography (LDCT) aiming to solve this problem. Nowadays, LDCT has gradually become a main stream of CT examination. OBJECTIVE This study aimed to assess the feasibility of LDCTAin an animal model and compare the imaging features and doses in two clinical scanners. METHODS Twenty-two New Zealand rabbit head and neck CTA images pre- and post-contrast agent injection were performed using256-sliceand 64-slice CT scanners. The tube voltages used in the 256-slice and the 64-slice CTA were 70 kVp and 80 kVp, respectively. Quantitative images indices and radiation doses obtained from CTA in these two scanners were compared. RESULTS More neck arterial vessels could be visualized in multi-planar reconstruction (MPR) CTA on the 256-slice CT scanner than on the 64-slice CT scanner. After contrast agent injection, all observed neck arterial vessels had higher CT numbers in 256-slice CTA than in 64-slice CTA. There was no significant difference in contrast-to-noise (CNR) of CTA images between these two scanners. CT dose index (CTDI) and dose length product (DLP) for the 256-slice CTA were lower than those for the 64-slice CTA. CONCLUSIONS Low dose CTA of rabbits with 70 or 80 kVp is feasible in a 256-slice or a 64-slice CT scanner. The radiation dose from the 256-slice CTA was much lower than that from the 64-slice CTA with comparable SNR and CNR. The technique can be further applied in longitudinal monitoring of an animal stroke model in the future.
Collapse
Affiliation(s)
- Chia-Chi Hsiao
- Department of Radiology, Kaohsiung Veterans General Hospital, Taiwan, R.O.C
| | - Po-Chou Chen
- Department of Biomedical Engineering, I-Shou University, Taiwan, R.O.C
| | - Pei-Chi Kuo
- Department of Biomedical Engineering, I-Shou University, Taiwan, R.O.C
| | - Chih-Hao Ho
- Department of Medical Imaging, Taipei City Hospital (Yangming Branch), Taiwan, R.O.C
| | - Jo-Chi Jao
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Taiwan, R.O.C
| |
Collapse
|
7
|
Chung MS, Choi YJ, Hwang JY, Yoon DH, Seo KJ, Lee JH, Baek JH. Feasibility of reduced-dose CT of the head and neck with iterative reconstruction: a phantom and prospective clinical study. Acta Radiol 2019; 60:1457-1464. [PMID: 30776905 DOI: 10.1177/0284185119830276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Mi Sun Chung
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea
| | - Young Jun Choi
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Jae-Yeon Hwang
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeonsangnam-do, Republic of Korea
| | - Dok Hyun Yoon
- Department of Oncology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Kyeong Jin Seo
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Jeong Hyun Lee
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Jung Hwan Baek
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| |
Collapse
|
8
|
Ultra-Low-Dose Neck CT With Low-Dose Contrast Material for Preoperative Staging of Thyroid Cancer: Image Quality and Diagnostic Performance. AJR Am J Roentgenol 2019; 212:748-754. [PMID: 30900916 DOI: 10.2214/ajr.18.20334] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Although CT has been used as a complementary diagnostic method for the preoperative diagnosis of thyroid cancer, it has the shortcomings of substantial radiation exposure and the use of contrast material (CM). The purpose of this article is to evaluate the image quality and diagnostic performance of 70-kVp thyroid CT with low volumes of CM versus conventional 120-kVp thyroid CT protocol. MATERIALS AND METHODS Eighty patients referred for preoperative thyroid CT were randomly divided into two groups (group A: 40 patients, 70 kVp, 60 mL of CM; group B: 40 patients, 120 kVp, 100 mL of CM). Quantitative and qualitative image quality and radiation doses for the two groups were compared using the Mann-Whitney U and chi-square tests. Degrees of agreement between preoperative CT staging and pathologic results were evaluated and compared using the Wald statistic. RESULTS Calculated signal-to-noise ratios of different anatomic structures, calculated contrast-to-noise ratios, overall image quality, subjective noise, and streak artifacts were not significantly different between the two groups (all p > 0.05), and neither were the accuracies of preoperative CT staging (all p > 0.05). The estimated effective doses were significantly lower in group A (mean [± SD], 0.52 ± 0.14 mSv in group A and 2.28 ± 0.29 mSv in group B; p < 0.001). CONCLUSION Ultra-low-dose 70-kVp CT with a low volume of CM provides sufficient image quality for preoperative staging of thyroid cancer and substantially reduces the radiation dose compared with standard 120-kVp CT.
Collapse
|
9
|
Leithner D, Gruber-Rouh T, Beeres M, Wichmann JL, Mahmoudi S, Martin SS, Lenga L, Albrecht MH, Booz C, Vogl TJ, Scholtz JE. 90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism. Br J Radiol 2018; 91:20180269. [PMID: 29792729 DOI: 10.1259/bjr.20180269] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
OBJECTIVE To evaluate low-tube-voltage 90-kVp CT pulmonary angiography (CTPA) with advanced modeled iterative reconstruction algorithm (Admire) compared to 120-kVp equivalent dual-energy (DE) acquisition with regards to radiation exposure, image quality and diagnostic accuracy for pulmonary embolism (PE) assessment. METHODS CTPA studies of 40 patients with suspected PE (56.7 ± 16.3 years) performed on a third-generation 192-slice dual-source CT scanner were retrospectively included. 120-kVp equivalent linearly-blended (60% 90-kVp, 40% 150-kVp) and 90-kVp images were reconstructed. Attenuation and noise of the pulmonary trunk were measured to calculate contrast-to-noise ratios (CNR). Three radiologists assessed the presence of central and segmental PE and diagnostic confidence. Interobserver agreement was calculated using intraclass correlation coefficient (ICC). Radiation exposure was assessed as effective dose (ED). RESULTS Pulmonary trunk CNR values were significantly increased in 90-kVp compared to linearly-blended series (15.4 ± 6.3 vs 11.3 ± 4.6, p < 0.001). Diagnostic accuracy for PE assessment was similar in both series with excellent interobserver agreement (p = 0.48; ICC, 0.83; p = 0.48). Overall confidence for PE assessment was rated excellent for both series with a significant advantage for linearly-blended series (p < 0.001; 4.1 vs 3.8). ED was reduced by 37.2% with 90-kVp compared to 120-kVp equivalent image series (1.1 ± 0.6 vs 1.7 ± 0.7 mSv, p < 0.001). CONCLUSION 90-kVp CTPA with Admire provided increased quantitative image quality with similar diagnostic accuracy and confidence for PE assessment compared to 120-kVp equivalent acquisition, while radiation dose was reduced by 37.2%. Advances in knowledge: 90-kVp CTPA with an advanced iterative reconstruction algorithm results in excellent image quality and reduction of radiation exposure without limiting diagnostic performance.
Collapse
Affiliation(s)
- Doris Leithner
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany.,2 Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center , New York, NY , USA
| | - Tatjana Gruber-Rouh
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Martin Beeres
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Julian L Wichmann
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Scherwin Mahmoudi
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Simon S Martin
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Lukas Lenga
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Moritz H Albrecht
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Christian Booz
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Thomas J Vogl
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Jan-Erik Scholtz
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany.,3 Department of Radiology, Massachusetts General Hospital, Cardiac MR PET CT Program, Harvard Medical School , Boston, MA , USA
| |
Collapse
|
10
|
Leithner D, Wichmann JL, Mahmoudi S, Martin SS, Albrecht MH, Vogl TJ, Scholtz JE. Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis. Br J Radiol 2018; 91:20170927. [PMID: 29493282 DOI: 10.1259/bjr.20170927] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVE To investigate the impact of low-tube-voltage 90-kVp acquisition combined with advanced modeled iterative reconstruction algorithm (Admire) on radiation exposure, image quality, artifacts, and assessment of stenosis in carotid and intracranial CT angiography (CTA). METHODS Dual-energy CTA studies of 43 patients performed on a third-generation 192-slice dual-source CT were retrospectively evaluated. Intraindividual comparison of 90-kVp and linearly blended 120-kVp equivalent image series (M_0.6, 60% 90-kVp, 40% Sn-150-kVp) was performed. Contrast-to-noise and signal-to-noise ratios of common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery were calculated. Qualitative image analysis included evaluation of artifacts and suitability for angiographical assessment at shoulder level, carotid bifurcation, siphon, and intracranial by three independent radiologists. Detection and quantification of carotid stenosis were performed. Radiation dose was expressed as dose-length product (DLP). RESULTS Contrast-to-noise values of all arteries were significantly increased in 90-kVp compared to M_0.6 (p < 0.001). Suitability for angiographical evaluation was rated excellent with low artifacts for all levels in both image series. Both 90-kVp and M_0.6 showed excellent accordance for detection and grading of carotid stenosis with almost perfect interobserver agreement (carotid stenoses in 32 of 129 segments; intraclass correlation coefficient, 0.94). dose-length product was reduced by 40.3% in 90-kVp (110.6 ± 32.1 vs 185.4 ± 47.5 mGy·cm, p < 0.001). CONCLUSION 90-kVp carotid and intracranial CTA with Admire provides increased quantitative and similarly good qualitative image quality, while reducing radiation exposure substantially compared to M_0.6. Diagnostic performance for arterial stenosis detection and quantification remained excellent. Advances in knowledge: 90-kVp carotid and intracranial CTA with an advanced iterative reconstruction algorithm results in excellent image quality and reduction of radiation exposure without limiting diagnostic performance.
Collapse
Affiliation(s)
- Doris Leithner
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Julian L Wichmann
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Scherwin Mahmoudi
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Simon S Martin
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Moritz H Albrecht
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Thomas J Vogl
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany
| | - Jan-Erik Scholtz
- 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany.,2 Division of Radiology, Massachusetts General Hospital, Harvard Medical School , Boston, MA , USA
| |
Collapse
|
11
|
Computed Tomography of the Head and Neck Region for Tumor Staging—Comparison of Dual-Source, Dual-Energy and Low-Kilovolt, Single-Energy Acquisitions. Invest Radiol 2017; 52:522-528. [DOI: 10.1097/rli.0000000000000377] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
12
|
Forghani R, Mukherji SK. Advanced dual-energy CT applications for the evaluation of the soft tissues of the neck. Clin Radiol 2017; 73:70-80. [PMID: 28476243 DOI: 10.1016/j.crad.2017.04.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 03/28/2017] [Accepted: 04/03/2017] [Indexed: 12/16/2022]
Abstract
There are multiple emerging advanced computed tomography (CT) applications for the evaluation of the neck, many based on dual-energy CT (DECT). DECT is an advanced form of CT in which scan acquisition is performed at two different energies, enabling spectral tissue characterisation beyond what is possible with conventional single-energy CT and potentially providing a new horizon for quantitative analysis and tissue characterisation, particularly in oncological imaging. The purpose of this review is to familiarise the reader with DECT principles and review different clinical applications for the evaluation of the soft tissues of the neck. The article will begin with an overview of DECT scan acquisition, material characterisation, reconstructions, and basic considerations for implementation in the clinical setting. This will then be followed by a review of different clinical applications. The focus will be on oncological imaging, but artefact reduction and other miscellaneous applications will also be discussed.
Collapse
Affiliation(s)
- R Forghani
- Department of Radiology, Jewish General Hospital & McGill University, 3755 Côte-Ste-Catherine Road, Montreal, Quebec, Canada, H3T 1E2; Segal Cancer Centre and Lady Davis Institute for Medical Research, Jewish General Hospital, 3755 Côte-Ste-Catherine Road, Montreal, Quebec, Canada, H3T 1E2.
| | - S K Mukherji
- Department of Radiology, Michigan State University, 846 Service Rd, East Lansing, Michigan 48824, USA
| |
Collapse
|
13
|
Roele ED, Timmer VCML, Vaassen LAA, van Kroonenburgh AMJL, Postma AA. Dual-Energy CT in Head and Neck Imaging. CURRENT RADIOLOGY REPORTS 2017; 5:19. [PMID: 28435761 PMCID: PMC5371622 DOI: 10.1007/s40134-017-0213-0] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE OF REVIEW To explain the technique of Dual-energy CT (DECT) and highlight its applications and advantages in head and neck radiology. RECENT FINDINGS Using DECT, additional datasets can be created next to conventional images. In head and neck radiology, three material decomposition algorithms can be used for improved lesion detection and delineation of the tumor. Iodine concentration measurements can aid in differentiating malignant from nonmalignant lymph nodes and benign posttreatment changes from tumor recurrence. Virtual non-calcium images can be used for detection of bone marrow edema. Virtual mono-energetic imaging can be useful for improved iodine conspicuity at lower keV and for reduction of metallic artifacts and increase in signal-to-noise ratio at higher keV. SUMMARY DECT and its additional reconstructions can play an important role in head and neck cancer patients, from initial diagnosis and staging, to therapy planning, evaluation of treatment response and follow-up. Moreover, it can be helpful in imaging of infections and inflammation and parathyroid imaging as supplementary reconstructions can be obtained at lower or equal radiation dose compared with conventional single energy scanning.
Collapse
Affiliation(s)
- Elise D. Roele
- Department of Radiology, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | - Veronique C. M. L. Timmer
- Department of Cranio and Maxillofacial Surgery, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | - Lauretta A. A. Vaassen
- Department of Cranio and Maxillofacial Surgery, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | | | - A. A. Postma
- Department of Radiology, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| |
Collapse
|
14
|
Schmid AI, Uder M, Lell MM. Reaching for better image quality and lower radiation dose in head and neck CT: advanced modeled and sinogram-affirmed iterative reconstruction in combination with tube voltage adaptation. Dentomaxillofac Radiol 2016; 46:20160131. [PMID: 27540625 DOI: 10.1259/dmfr.20160131] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES The aim of this study was to evaluate image quality and radiation dose in low-dose head and neck CT comparing two different commercially available iterative reconstruction algorithms: sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modeled iterative reconstruction (ADMIRE) with fixed and automated tube voltage adaptation (TVA). METHODS CT examinations of 103 patients were analysed. 58 patients were examined on a single-source CT at fixed tube voltage of 120 kV and reconstructed with filtered back projection (FBP) and SAFIRE (Strength Level 3). 45 patients were examined in a single-source mode on a dual-source CT with automated TVA and reconstructed with FBP and ADMIRE (Strength Levels 2 and 3). Image noise was calculated in seven anatomical volumes of interest. Subjective evaluation of the CT images was performed using a four-grade scale. RESULTS Mean CT numbers of FBP and the corresponding iterative reconstruction did not differ significantly (p = 0.74-0.99). Image noise was lower with both iterative reconstruction techniques than with FBP (SAFIRE 3: -22.3%; ADMIRE 2: -14.9%; ADMIRE 3: -24.2%; all p < 0.05); hence, the signal-to-noise ratio and the contrast-to-noise values were higher. Subjective image quality revealed a more favourable result for the iterative reconstruction. ADMIRE 3 in combination with automated TVA showed 14.4% (p < 0.05) less image noise with a 7.5% lower radiation dose than SAFIRE 3 with fixed tube voltage. CONCLUSIONS Higher image quality at lower radiation dose can be achieved using ADMIRE in combination with automated TVA.
Collapse
Affiliation(s)
- Andrea I Schmid
- 1 Department of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany
| | - Michael Uder
- 1 Department of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany.,2 Imaging Science Institute (ISI) Erlangen, Department of Radiology, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany
| | - Michael M Lell
- 1 Department of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany.,3 Department of Radiology and Nuclear Medicine, Klinikum Nürnberg, Germany, Paracelsus Medical University
| |
Collapse
|
15
|
Langner S. Optimized imaging of the midface and orbits. GMS CURRENT TOPICS IN OTORHINOLARYNGOLOGY, HEAD AND NECK SURGERY 2016; 14:Doc05. [PMID: 26770279 PMCID: PMC4702054 DOI: 10.3205/cto000120] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
A variety of imaging techniques are available for imaging the midface and orbits. This review article describes the different imaging techniques based on the recent literature and discusses their impact on clinical routine imaging. Imaging protocols are presented for different diseases and the different imaging modalities.
Collapse
Affiliation(s)
- Sönke Langner
- Institute for Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Germany
| |
Collapse
|
16
|
Scholtz JE, Kaup M, Hüsers K, Albrecht MH, Bodelle B, Metzger SC, Kerl JM, Bauer RW, Lehnert T, Vogl TJ, Wichmann JL. Advanced Modeled Iterative Reconstruction in Low-Tube-Voltage Contrast-Enhanced Neck CT: Evaluation of Objective and Subjective Image Quality. AJNR Am J Neuroradiol 2016; 37:143-50. [PMID: 26427836 DOI: 10.3174/ajnr.a4502] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Accepted: 06/10/2015] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND PURPOSE Dose-saving techniques in neck CT cause increased image noise that can be counteracted by iterative reconstruction. Our aim was to evaluate the image quality of advanced modeled iterative reconstruction (ADMIRE) in contrast-enhanced low-tube-voltage neck CT. MATERIALS AND METHODS Sixty-one patients underwent 90-kV(peak) neck CT by using third-generation 192-section dual-source CT. Image series were reconstructed with standard filtered back-projection and ADMIRE strength levels 1, 3, and 5. Attenuation and noise of the sternocleidomastoid muscle, internal jugular vein, submandibular gland, tongue, subscapularis muscle, and cervical fat were measured. Signal-to-noise and contrast-to-noise ratios were calculated. Two radiologists assessed image noise, image contrast, delineation of smaller structures, and overall diagnostic acceptability. Interobserver agreement was calculated. RESULTS Image noise was significantly reduced by using ADMIRE compared with filtered back-projection with the lowest noise observed in ADMIRE 5 (filtered back-projection, 9.4 ± 2.4 Hounsfield units [HU]; ADMIRE 1, 8.3 ± 2.8 HU; ADMIRE 3, 6.7 ± 2.0 HU; ADMIRE 5, 5.4 ± 1.7 HU; all, P < .001). Sternocleidomastoid SNR and internal jugular vein-sternocleidomastoid contrast-to-noise ratios were significantly higher for ADMIRE with the best results in ADMIRE 5 (all, P < .001). Subjective image quality and image contrast of ADMIRE 3 and 5 were consistently rated better than those for filtered back-projection and ADMIRE 1 (all, P < .001). Image noise was rated highest for ADMIRE 5 (all, P < .005). Delineation of smaller structures was voted higher in all ADMIRE strength levels compared with filtered back-projection (P < .001). Global interobserver agreement was good (0.75). CONCLUSIONS Contrast-enhanced 90-kVp neck CT is feasible, and ADMIRE 5 shows superior objective image quality compared with filtered back-projection. ADMIRE 3 and 5 show the best subjective image quality.
Collapse
Affiliation(s)
- J-E Scholtz
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - M Kaup
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - K Hüsers
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - M H Albrecht
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - B Bodelle
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - S C Metzger
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - J M Kerl
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - R W Bauer
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - T Lehnert
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - T J Vogl
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany
| | - J L Wichmann
- From the Department of Diagnostic and Interventional Radiology (J.-E.S., M.K., K.H., M.H.A., B.B., S.C.M., J.M.K., R.W.B., T.L., T.J.V., J.L.W.), University Hospital Frankfurt, Frankfurt, Germany Department of Radiology and Radiological Science (J.L.W.), Medical University of South Carolina, Charleston, South Carolina
| |
Collapse
|
17
|
Thaiss WM, Sauter AW, Bongers M, Horger M, Nikolaou K. Clinical applications for dual energy CT versus dynamic contrast enhanced CT in oncology. Eur J Radiol 2015; 84:2368-79. [DOI: 10.1016/j.ejrad.2015.06.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Accepted: 06/02/2015] [Indexed: 12/12/2022]
|
18
|
Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose. Eur Radiol 2015; 26:2623-31. [PMID: 26560726 DOI: 10.1007/s00330-015-4099-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Revised: 10/28/2015] [Accepted: 10/29/2015] [Indexed: 02/03/2023]
|
19
|
|
20
|
Automated tube voltage adaptation in combination with advanced modeled iterative reconstruction in thoracoabdominal third-generation 192-slice dual-source computed tomography: effects on image quality and radiation dose. Acad Radiol 2015; 22:1081-7. [PMID: 26163706 DOI: 10.1016/j.acra.2015.05.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 05/20/2015] [Accepted: 05/25/2015] [Indexed: 12/29/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate image quality and radiation exposure of portal venous-phase thoracoabdominal third-generation 192-slice dual-source computed tomography (DSCT) with automated tube voltage adaptation (TVA) in combination with advanced modeled iterative reconstruction (ADMIRE). MATERIALS AND METHODS Fifty-one patients underwent oncologic portal venous-phase thoracoabdominal follow-up CT twice within 7 months. The initial examination was performed on second-generation 128-slice DSCT with fixed tube voltage of 120 kV in combination with filtered back projection reconstruction. The second examination was performed on a third-generation 192-slice DSCT using automated TVA in combination with ADMIRE. Attenuation and image noise of liver, spleen, renal cortex, aorta, vena cava inferior, portal vein, psoas muscle, and perinephric fat were measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Radiation dose was assessed as size-specific dose estimates (SSDE). Subjective image quality was assessed by two observers using five-point Likert scales. Interobserver agreement was calculated using intraclass correlation coefficients (ICC). RESULTS Automated TVA set tube voltage to 90 kV (n = 8), 100 kV (n = 31), 110 kV (n = 11), or 120 kV (n = 1). Average SSDE was decreased by 34.9% using 192-slice DSCT compared to 128-slice 120-kV DSCT (7.8 ± 2.4 vs. 12.1 ± 3.2 mGy; P < .001). Image noise was substantially lower; SNR and CNR were significantly increased in 192-slice DSCT compared to 128-slice DSCT (all P < .005). Image quality was voted excellent for both acquisition techniques (5.00 vs. 4.93; P = .083). CONCLUSIONS Automated TVA in combination with ADMIRE on third-generation 192-slice DSCT in portal venous-phase thoracoabdominal CT provides excellent image quality with reduced image noise and increased SNR and CNR, whereas average radiation dose is reduced by 34.9% compared to 128-slice DSCT.
Collapse
|
21
|
Evaluation of image quality and dose reduction of 80 kVp neck computed tomography in patients with suspected peritonsillar abscess. Clin Radiol 2015; 70:e67-73. [DOI: 10.1016/j.crad.2015.04.009] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Revised: 04/09/2015] [Accepted: 04/20/2015] [Indexed: 12/12/2022]
|
22
|
Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography. Neuroradiology 2015; 57:645-51. [DOI: 10.1007/s00234-015-1512-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Accepted: 03/13/2015] [Indexed: 11/24/2022]
|
23
|
Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer. Eur Radiol 2015; 25:2493-501. [PMID: 25680727 DOI: 10.1007/s00330-015-3627-1] [Citation(s) in RCA: 118] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 12/05/2014] [Accepted: 01/21/2015] [Indexed: 10/24/2022]
Abstract
OBJECTIVES To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). METHODS DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. RESULTS The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056). CONCLUSIONS Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. KEY POINTS • Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers.
Collapse
|