1
|
Jiang J, Qiu J, Yin J, Wang J, Jiang X, Yi Z, Chen Y, Zhou X, Sima X. Automated detection of hippocampal sclerosis using real-world clinical MRI images. Front Neurosci 2023; 17:1180679. [PMID: 37255750 PMCID: PMC10225575 DOI: 10.3389/fnins.2023.1180679] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 04/26/2023] [Indexed: 06/01/2023] Open
Abstract
Background Hippocampal sclerosis (HS) is the most common pathological type of temporal lobe epilepsy (TLE) and one of the important surgical markers. Currently, HS is mainly diagnosed manually by radiologists based on visual inspection of MRI, which greatly relies on MRI quality and physician experience. In clinical practice, non-thin MRI scans are often used due to the time and efficiency needed for the acquisition. However, these scans can be difficult for junior physicians to interpret accurately. Thus, the rapid and accurate diagnosis of HS using real-world MRI images in clinical settings is a challenging task. Objective Our aim was to explore the feasibility of using computer vision methods to diagnose HS on real-world clinical MRI images and to provide a reference for future clinical applications of artificial intelligence methods to aid in detecting HS. Methods We proposed a deep learning algorithm called "HS-Net" to discriminate HS using real-world clinical MRI images. First, we delineated and segmented a region of interest (ROI) around the hippocampus. Then, we utilized the fractional differential (FD) method to enhance the textures of the ROIs. Finally, we used a small-sample image classification method based on transfer learning to fine-tune the feature extraction part of a pretrained model and added two fully connected layers and an output layer. In the study, 96 TLE patients with HS confirmed by postoperative pathology and 89 healthy controls were retrospectively enrolled. All subjects were cross-validated, and models were evaluated for performance, robustness, and clinical utility. Results The HS-Net model achieved an area under the curve (AUC) of 0.894, an accuracy of 82.88%, an F1-score of 84.08% in the test cohort based on real, routine, clinical T2-weighted fluid attenuated inversion recovery (FLAIR) sequence MRI images. Additionally, the AUC, accuracy and F1 scores of our model all increased by around 3 percentage points when the inputs were augmented with the ROIs of the textures enhanced using the FD method. Conclusions Our computational model has the potential to be used for the diagnosis of HS in real clinical MRI images, which could assist physicians, particularly junior physicians, in improving the accuracy of discrimination.
Collapse
Affiliation(s)
- Jingwen Jiang
- Department of Neurosurgery and West China Biomedical Big Data Center, West China Hospital of Sichuan University, Chengdu, China
- Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Jiajun Qiu
- Department of Neurosurgery and West China Biomedical Big Data Center, West China Hospital of Sichuan University, Chengdu, China
- Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Jin Yin
- Department of Neurosurgery and West China Biomedical Big Data Center, West China Hospital of Sichuan University, Chengdu, China
- Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Junren Wang
- Department of Neurosurgery and West China Biomedical Big Data Center, West China Hospital of Sichuan University, Chengdu, China
- Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Xinyue Jiang
- Department of Radiology, Chengdu Second People's Hospital, Chengdu, China
| | - Zuo Yi
- Department of Computer Science and Technology, College of Computer Science, Sichuan University, Chengdu, China
| | - Yang Chen
- Department of Neurosurgery and West China Biomedical Big Data Center, West China Hospital of Sichuan University, Chengdu, China
| | - Xiaobo Zhou
- School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, United States
| | - Xiutian Sima
- Department of Neurosurgery, West China Hospital of Sichuan University, Chengdu, China
| |
Collapse
|
2
|
Pemberton HG, Collij LE, Heeman F, Bollack A, Shekari M, Salvadó G, Alves IL, Garcia DV, Battle M, Buckley C, Stephens AW, Bullich S, Garibotto V, Barkhof F, Gispert JD, Farrar G. Quantification of amyloid PET for future clinical use: a state-of-the-art review. Eur J Nucl Med Mol Imaging 2022; 49:3508-3528. [PMID: 35389071 PMCID: PMC9308604 DOI: 10.1007/s00259-022-05784-y] [Citation(s) in RCA: 91] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 03/25/2022] [Indexed: 12/15/2022]
Abstract
Amyloid-β (Aβ) pathology is one of the earliest detectable brain changes in Alzheimer's disease (AD) pathogenesis. The overall load and spatial distribution of brain Aβ can be determined in vivo using positron emission tomography (PET), for which three fluorine-18 labelled radiotracers have been approved for clinical use. In clinical practice, trained readers will categorise scans as either Aβ positive or negative, based on visual inspection. Diagnostic decisions are often based on these reads and patient selection for clinical trials is increasingly guided by amyloid status. However, tracer deposition in the grey matter as a function of amyloid load is an inherently continuous process, which is not sufficiently appreciated through binary cut-offs alone. State-of-the-art methods for amyloid PET quantification can generate tracer-independent measures of Aβ burden. Recent research has shown the ability of these quantitative measures to highlight pathological changes at the earliest stages of the AD continuum and generate more sensitive thresholds, as well as improving diagnostic confidence around established binary cut-offs. With the recent FDA approval of aducanumab and more candidate drugs on the horizon, early identification of amyloid burden using quantitative measures is critical for enrolling appropriate subjects to help establish the optimal window for therapeutic intervention and secondary prevention. In addition, quantitative amyloid measurements are used for treatment response monitoring in clinical trials. In clinical settings, large multi-centre studies have shown that amyloid PET results change both diagnosis and patient management and that quantification can accurately predict rates of cognitive decline. Whether these changes in management reflect an improvement in clinical outcomes is yet to be determined and further validation work is required to establish the utility of quantification for supporting treatment endpoint decisions. In this state-of-the-art review, several tools and measures available for amyloid PET quantification are summarised and discussed. Use of these methods is growing both clinically and in the research domain. Concurrently, there is a duty of care to the wider dementia community to increase visibility and understanding of these methods.
Collapse
Affiliation(s)
- Hugh G Pemberton
- GE Healthcare, Amersham, UK.
- Centre for Medical Image Computing (CMIC), Department of Medical Physics and Bioengineering, University College London, London, UK.
- UCL Queen Square Institute of Neurology, University College London, London, UK.
| | - Lyduine E Collij
- Department of Radiology and Nuclear Medicine, Amsterdam Neurocience, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Fiona Heeman
- Department of Radiology and Nuclear Medicine, Amsterdam Neurocience, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Ariane Bollack
- Centre for Medical Image Computing (CMIC), Department of Medical Physics and Bioengineering, University College London, London, UK
| | - Mahnaz Shekari
- Barcelonaβeta Brain Research Center (BBRC), Pasqual Maragall Foundation, Barcelona, Spain
- Universitat Pompeu Fabra, Barcelona, Spain
- IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain
| | - Gemma Salvadó
- Barcelonaβeta Brain Research Center (BBRC), Pasqual Maragall Foundation, Barcelona, Spain
- Clinical Memory Research Unit, Department of Clinical Sciences, Lund University, Malmö, Sweden
| | - Isadora Lopes Alves
- Department of Radiology and Nuclear Medicine, Amsterdam Neurocience, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Brain Research Center, Amsterdam, The Netherlands
| | - David Vallez Garcia
- Department of Radiology and Nuclear Medicine, Amsterdam Neurocience, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Mark Battle
- GE Healthcare, Amersham, UK
- Clinical Memory Research Unit, Department of Clinical Sciences, Lund University, Malmö, Sweden
| | | | | | | | - Valentina Garibotto
- Division of Nuclear Medicine and Molecular Imaging, University Hospitals of Geneva, Geneva, Switzerland
- NIMTLab, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Frederik Barkhof
- Centre for Medical Image Computing (CMIC), Department of Medical Physics and Bioengineering, University College London, London, UK
- UCL Queen Square Institute of Neurology, University College London, London, UK
- Department of Radiology and Nuclear Medicine, Amsterdam Neurocience, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Juan Domingo Gispert
- Barcelonaβeta Brain Research Center (BBRC), Pasqual Maragall Foundation, Barcelona, Spain
- Universitat Pompeu Fabra, Barcelona, Spain
- IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain
- Centro de Investigación Biomédica en Red Bioingeniería, Biomateriales y Nanomedicina, Madrid, Spain
| | | |
Collapse
|
3
|
Pemberton HG, Zaki LAM, Goodkin O, Das RK, Steketee RME, Barkhof F, Vernooij MW. Technical and clinical validation of commercial automated volumetric MRI tools for dementia diagnosis-a systematic review. Neuroradiology 2021; 63:1773-1789. [PMID: 34476511 PMCID: PMC8528755 DOI: 10.1007/s00234-021-02746-3] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 06/02/2021] [Indexed: 12/22/2022]
Abstract
Developments in neuroradiological MRI analysis offer promise in enhancing objectivity and consistency in dementia diagnosis through the use of quantitative volumetric reporting tools (QReports). Translation into clinical settings should follow a structured framework of development, including technical and clinical validation steps. However, published technical and clinical validation of the available commercial/proprietary tools is not always easy to find and pathways for successful integration into the clinical workflow are varied. The quantitative neuroradiology initiative (QNI) framework highlights six necessary steps for the development, validation and integration of quantitative tools in the clinic. In this paper, we reviewed the published evidence regarding regulatory-approved QReports for use in the memory clinic and to what extent this evidence fulfils the steps of the QNI framework. We summarize unbiased technical details of available products in order to increase the transparency of evidence and present the range of reporting tools on the market. Our intention is to assist neuroradiologists in making informed decisions regarding the adoption of these methods in the clinic. For the 17 products identified, 11 companies have published some form of technical validation on their methods, but only 4 have published clinical validation of their QReports in a dementia population. Upon systematically reviewing the published evidence for regulatory-approved QReports in dementia, we concluded that there is a significant evidence gap in the literature regarding clinical validation, workflow integration and in-use evaluation of these tools in dementia MRI diagnosis.
Collapse
Affiliation(s)
- Hugh G Pemberton
- Centre for Medical Image Computing (CMIC), Department of Medical Physics and Bioengineering, University College London, London, UK.
- UCL Queen Square Institute of Neurology, University College London, London, UK.
- Dementia Research Centre, UCL Queen Square Institute of Neurology, University College London, London, UK.
| | - Lara A M Zaki
- Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Olivia Goodkin
- Centre for Medical Image Computing (CMIC), Department of Medical Physics and Bioengineering, University College London, London, UK
- UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Ravi K Das
- Clinical, Educational and Health Psychology, University College London, London, UK
| | - Rebecca M E Steketee
- Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Frederik Barkhof
- Centre for Medical Image Computing (CMIC), Department of Medical Physics and Bioengineering, University College London, London, UK
- UCL Queen Square Institute of Neurology, University College London, London, UK
- Radiology & Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| | - Meike W Vernooij
- Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
- Department of Epidemiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
4
|
Mettenburg JM. Notification of a Voluntary Product Recall for Software Used in a Prior Published Article. AJNR Am J Neuroradiol 2021; 42:E34. [PMID: 33707280 DOI: 10.3174/ajnr.a7063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- J M Mettenburg
- Department of RadiologyUniversity of Pittsburgh School of MedicinePittsburgh, Pennsylvania
| |
Collapse
|
5
|
Meysami S, Raji CA, Merrill DA, Porter VR, Mendez MF. MRI Volumetric Quantification in Persons with a History of Traumatic Brain Injury and Cognitive Impairment. J Alzheimers Dis 2020; 72:293-300. [PMID: 31561375 DOI: 10.3233/jad-190708] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
BACKGROUND While traumatic brain injury (TBI) is recognized as a risk factor for dementia, there is lack of clinical tools to identify brain changes that may confer such vulnerability. Brain MRI volumetric quantification can sensitively identify brain atrophy. OBJECTIVE To characterize regional brain volume loss in persons with TBI presenting with cognitive impairment. METHODS IRB approved review of medical records in patients with cognitive decline focused on those who had documented TBI histories and brain MRI scans after TBI (n = 40, 67.7±14.5 years) with volumetric quantification by applying an FDA cleared software program. TBI documentation included head trauma mechanism. Brain volumes were compared to a normative database to determine the extent of atrophy. Correlations between these regions and global tests of cognition (MMSE in n = 17, MoCA in n = 27, n = 14 in both) were performed. RESULTS Multiple regions demonstrated volume loss in TBI, particularly ventral diencephalon, putamen, and pallidum with smaller magnitude of atrophy in temporal lobes and brainstem. Lobar structures showed strongest correlations between atrophy and lower scores on MMSE and MoCA. The hippocampus, while correlated to tests of cognitive function, was the least atrophic region as a function of TBI history. CONCLUSION Persons with TBI history exhibit show regional brain atrophy. Several of these areas, such as thalamus and temporal lobes, also correlate with cognitive function. Alzheimer's disease atrophy was less likely given relative sparing of the hippocampi. Volumetric quantification of brain MRI in TBI warrants further investigation to further determine its clinical potential in TBI and differentiating causes of cognitive impairment.
Collapse
Affiliation(s)
- Somayeh Meysami
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | - Cyrus A Raji
- Mallinckrodt Institute of Radiology, Division of Neuroradiology, Washington University, St. Louis, MO, USA
| | - David A Merrill
- Department of Psychiatry and Biobehavioral Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,The John Wayne Cancer Institute and Pacific Neuroscience Institute, Providence and St. Johns Health Center, Santa Monica, CA, USA
| | - Verna R Porter
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,The John Wayne Cancer Institute and Pacific Neuroscience Institute, Providence and St. Johns Health Center, Santa Monica, CA, USA
| | - Mario F Mendez
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,Department of Psychiatry and Biobehavioral Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,V.A. Greater Los Angeles Healthcare System, Los Angeles, CA, USA
| |
Collapse
|
6
|
Goodkin O, Pemberton HG, Vos SB, Prados F, Das RK, Moggridge J, De Blasi B, Bartlett P, Williams E, Campion T, Haider L, Pearce K, Bargallό N, Sanchez E, Bisdas S, White M, Ourselin S, Winston GP, Duncan JS, Cardoso J, Thornton JS, Yousry TA, Barkhof F. Clinical evaluation of automated quantitative MRI reports for assessment of hippocampal sclerosis. Eur Radiol 2020; 31:34-44. [PMID: 32749588 PMCID: PMC7755617 DOI: 10.1007/s00330-020-07075-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 05/07/2020] [Accepted: 07/15/2020] [Indexed: 02/07/2023]
Abstract
OBJECTIVES Hippocampal sclerosis (HS) is a common cause of temporal lobe epilepsy. Neuroradiological practice relies on visual assessment, but quantification of HS imaging biomarkers-hippocampal volume loss and T2 elevation-could improve detection. We tested whether quantitative measures, contextualised with normative data, improve rater accuracy and confidence. METHODS Quantitative reports (QReports) were generated for 43 individuals with epilepsy (mean age ± SD 40.0 ± 14.8 years, 22 men; 15 histologically unilateral HS; 5 bilateral; 23 MR-negative). Normative data was generated from 111 healthy individuals (age 40.0 ± 12.8 years, 52 men). Nine raters with different experience (neuroradiologists, trainees, and image analysts) assessed subjects' imaging with and without QReports. Raters assigned imaging normal, right, left, or bilateral HS. Confidence was rated on a 5-point scale. RESULTS Correct designation (normal/abnormal) was high and showed further trend-level improvement with QReports, from 87.5 to 92.5% (p = 0.07, effect size d = 0.69). Largest magnitude improvement (84.5 to 93.8%) was for image analysts (d = 0.87). For bilateral HS, QReports significantly improved overall accuracy, from 74.4 to 91.1% (p = 0.042, d = 0.7). Agreement with the correct diagnosis (kappa) tended to increase from 0.74 ('fair') to 0.86 ('excellent') with the report (p = 0.06, d = 0.81). Confidence increased when correctly assessing scans with the QReport (p < 0.001, η2p = 0.945). CONCLUSIONS QReports of HS imaging biomarkers can improve rater accuracy and confidence, particularly in challenging bilateral cases. Improvements were seen across all raters, with large effect sizes, greatest for image analysts. These findings may have positive implications for clinical radiology services and justify further validation in larger groups. KEY POINTS • Quantification of imaging biomarkers for hippocampal sclerosis-volume loss and raised T2 signal-could improve clinical radiological detection in challenging cases. • Quantitative reports for individual patients, contextualised with normative reference data, improved diagnostic accuracy and confidence in a group of nine raters, in particular for bilateral HS cases. • We present a pre-use clinical validation of an automated imaging assessment tool to assist clinical radiology reporting of hippocampal sclerosis, which improves detection accuracy.
Collapse
Affiliation(s)
- Olivia Goodkin
- Centre for Medical Image Computing (CMIC), University College London, London, UK. .,Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.
| | - Hugh G Pemberton
- Centre for Medical Image Computing (CMIC), University College London, London, UK.,Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Sjoerd B Vos
- Centre for Medical Image Computing (CMIC), University College London, London, UK.,Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.,Epilepsy Society MRI Unit, Chalfont St Peter, UK
| | - Ferran Prados
- Centre for Medical Image Computing (CMIC), University College London, London, UK.,Universitat Oberta de Catalunya, Barcelona, Spain
| | - Ravi K Das
- Clinical, Educational and Health Psychology, University College London, London, UK
| | - James Moggridge
- Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.,Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK
| | - Bianca De Blasi
- Department of Medical Physics and Bioengineering, University College London, London, UK
| | - Philippa Bartlett
- Epilepsy Society MRI Unit, Chalfont St Peter, UK.,Department of Clinical and Experimental Epilepsy, University College London, London, UK
| | - Elaine Williams
- Wellcome Trust Centre for Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Thomas Campion
- Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK
| | - Lukas Haider
- Department of Biomedical Imaging and Image Guided Therapy, Medical University of Vienna, Vienna, Austria.,NMR Research Unit, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Kirsten Pearce
- Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK
| | - Nuria Bargallό
- Radiology Department, Hospital Clínic de Barcelona and Magnetic Resonance Image Core Facility, Institut d'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
| | - Esther Sanchez
- Radiology & Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| | - Sotirios Bisdas
- Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.,Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK
| | - Mark White
- Digital Services, University College London Hospital, London, UK
| | - Sebastien Ourselin
- Department of Medical Physics and Bioengineering, University College London, London, UK.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Gavin P Winston
- Epilepsy Society MRI Unit, Chalfont St Peter, UK.,Department of Clinical and Experimental Epilepsy, University College London, London, UK.,Department of Medicine, Division of Neurology, Queen's University, Kingston, Ontario, Canada
| | - John S Duncan
- Epilepsy Society MRI Unit, Chalfont St Peter, UK.,Department of Clinical and Experimental Epilepsy, University College London, London, UK
| | - Jorge Cardoso
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - John S Thornton
- Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.,Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK
| | - Tarek A Yousry
- Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.,Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK
| | - Frederik Barkhof
- Centre for Medical Image Computing (CMIC), University College London, London, UK.,Neuroradiological Academic Unit, UCL Queen Square Institute of Neurology, University College London, London, UK.,Lysholm Department of Neuroradiology, National Hospital for Neurology and Neurosurgery, UCLH NHS Foundation Trust, London, UK.,Radiology & Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
7
|
Damodaran N. Automated Segmentation of Hippocampal Volume: The Next Step in Neuroradiologic Diagnosis of Mesial Temporal Sclerosis. AJNR Am J Neuroradiol 2019; 40:E38. [PMID: 31171519 DOI: 10.3174/ajnr.a6092] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- N Damodaran
- Department of Neurosurgery Mahatma Gandhi Medical College and Research Institute Pondicherry, India
| |
Collapse
|