1
|
Tsutsui S, Matsuda T, Takeda K, Sasaki M, Kubo Y, Setta K, Fujiwara S, Chida K, Ogasawara K. Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI. AJNR Am J Neuroradiol 2022; 43:972-977. [PMID: 35738672 DOI: 10.3174/ajnr.a7561] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Accepted: 05/06/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND PURPOSE Patients with cerebral aneurysms often undergo MR imaging after microsurgical clipping. Ultra-high-field MR imaging at 7T may provide high diagnostic capability in such clinical situations. However, titanium alloy clips have safety issues such as adverse interactions with static magnetic fields and radiofrequency-induced heating during 7T MR imaging. The purpose of this study was to quantitatively assess temperature increases on various types of titanium alloy aneurysm clips during 7T MR imaging. MATERIALS AND METHODS Five types of titanium alloy aneurysm clips were tested, including combinations of short, long, straight, angled, and fenestrated types. Each clip was set in a phantom filled with gelled saline mixed with polyacrylic acid and underwent 7T MR imaging with 3D T1WI with a spoiled gradient recalled acquisition in the steady-state technique. Temperature was chronologically measured at the tips of the clip blade and head, angled part of the clip, and 5 mm from the tip of the clip head using MR imaging-compatible fiber-optic thermometers. RESULTS Temperature increases at all locations for right-angled and short straight clips were <1°C. Temperature increases at the angled part for the 45° angled clip and the tip of the clip head for the straight fenestrated clip were >1°C. Temperature increases at all locations for the long straight clip were >2°C. CONCLUSIONS Temperature increases on the right-angled and short straight clips remained below the regulatory limit during 7T MR imaging, but temperature increases on the 45° angled, straight fenestrated, and long straight clips exceeded this limit.
Collapse
Affiliation(s)
- S Tsutsui
- From the Department of Neurosurgery (S.T., Y.K., K.S., S.F., K.C., K.O.)
| | - T Matsuda
- Division of Ultrahigh Field MRI (T.M., K.T., M.S.), Institute for Biomedical Sciences, Iwate Medical University School of Medicine, Morioka, Japan
| | - K Takeda
- Division of Ultrahigh Field MRI (T.M., K.T., M.S.), Institute for Biomedical Sciences, Iwate Medical University School of Medicine, Morioka, Japan
| | - M Sasaki
- Division of Ultrahigh Field MRI (T.M., K.T., M.S.), Institute for Biomedical Sciences, Iwate Medical University School of Medicine, Morioka, Japan
| | - Y Kubo
- From the Department of Neurosurgery (S.T., Y.K., K.S., S.F., K.C., K.O.)
| | - K Setta
- From the Department of Neurosurgery (S.T., Y.K., K.S., S.F., K.C., K.O.)
| | - S Fujiwara
- From the Department of Neurosurgery (S.T., Y.K., K.S., S.F., K.C., K.O.)
| | - K Chida
- From the Department of Neurosurgery (S.T., Y.K., K.S., S.F., K.C., K.O.)
| | - K Ogasawara
- From the Department of Neurosurgery (S.T., Y.K., K.S., S.F., K.C., K.O.)
| |
Collapse
|
2
|
Jiang D, Lu H. Cerebral oxygen extraction fraction MRI: Techniques and applications. Magn Reson Med 2022; 88:575-600. [PMID: 35510696 PMCID: PMC9233013 DOI: 10.1002/mrm.29272] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/20/2022] [Accepted: 03/29/2022] [Indexed: 12/20/2022]
Abstract
The human brain constitutes 2% of the body's total mass but uses 20% of the oxygen. The rate of the brain's oxygen utilization can be derived from a knowledge of cerebral blood flow and the oxygen extraction fraction (OEF). Therefore, OEF is a key physiological parameter of the brain's function and metabolism. OEF has been suggested to be a useful biomarker in a number of brain diseases. With recent advances in MRI techniques, several MRI-based methods have been developed to measure OEF in the human brain. These MRI OEF techniques are based on the T2 of blood, the blood signal phase, the magnetic susceptibility of blood-containing voxels, the effect of deoxyhemoglobin on signal behavior in extravascular tissue, and the calibration of the BOLD signal using gas inhalation. Compared to 15 O PET, which is considered the "gold standard" for OEF measurement, MRI-based techniques are non-invasive, radiation-free, and are more widely available. This article provides a review of these emerging MRI-based OEF techniques. We first briefly introduce the role of OEF in brain oxygen homeostasis. We then review the methodological aspects of different categories of MRI OEF techniques, including their signal mechanisms, acquisition methods, and data analyses. The strengths and limitations of the techniques are discussed. Finally, we review key applications of these techniques in physiological and pathological conditions.
Collapse
Affiliation(s)
- Dengrong Jiang
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Hanzhang Lu
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| |
Collapse
|