1
|
Yamada S, Yassin MA, Torelli F, Hansmann J, Green JBA, Schwarz T, Mustafa K. Unique osteogenic profile of bone marrow stem cells stimulated in perfusion bioreactor is Rho-ROCK-mediated contractility dependent. Bioeng Transl Med 2023; 8:e10509. [PMID: 37206242 PMCID: PMC10189446 DOI: 10.1002/btm2.10509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/28/2023] [Accepted: 03/04/2023] [Indexed: 03/19/2023] Open
Abstract
The fate determination of bone marrow mesenchymal stem/stromal cells (BMSC) is tightly regulated by mechanical cues, including fluid shear stress. Knowledge of mechanobiology in 2D culture has allowed researchers in bone tissue engineering to develop 3D dynamic culture systems with the potential for clinical translation in which the fate and growth of BMSC are mechanically controlled. However, due to the complexity of 3D dynamic cell culture compared to the 2D counterpart, the mechanisms of cell regulation in the dynamic environment remain relatively undescribed. In the present study, we analyzed the cytoskeletal modulation and osteogenic profiles of BMSC under fluid stimuli in a 3D culture condition using a perfusion bioreactor. BMSC subjected to fluid shear stress (mean 1.56 mPa) showed increased actomyosin contractility, accompanied by the upregulation of mechanoreceptors, focal adhesions, and Rho GTPase-mediated signaling molecules. Osteogenic gene expression profiling revealed that fluid shear stress promoted the expression of osteogenic markers differently from chemically induced osteogenesis. Osteogenic marker mRNA expression, type 1 collagen formation, ALP activity, and mineralization were promoted in the dynamic condition, even in the absence of chemical supplementation. The inhibition of cell contractility under flow by Rhosin chloride, Y27632, MLCK inhibitor peptide-18, or Blebbistatin revealed that actomyosin contractility was required for maintaining the proliferative status and mechanically induced osteogenic differentiation in the dynamic culture. The study highlights the cytoskeletal response and unique osteogenic profile of BMSC in this type of dynamic cell culture, stepping toward the clinical translation of mechanically stimulated BMCS for bone regeneration.
Collapse
Affiliation(s)
- Shuntaro Yamada
- Center of Translational Oral Research (TOR)‐Tissue Engineering Group, Department of Clinical Dentistry, Faculty of MedicineUniversity of BergenNorway
| | - Mohammed A. Yassin
- Center of Translational Oral Research (TOR)‐Tissue Engineering Group, Department of Clinical Dentistry, Faculty of MedicineUniversity of BergenNorway
| | - Francesco Torelli
- Center of Translational Oral Research (TOR)‐Tissue Engineering Group, Department of Clinical Dentistry, Faculty of MedicineUniversity of BergenNorway
| | - Jan Hansmann
- Translational Center Regenerative TherapiesFraunhofer Institute for Silicate Research ISCWürzburgGermany
- Chair of Tissue Engineering and Regenerative MedicineUniversity Hospital WürzburgWürzburgGermany
- Department of Electrical EngineeringUniversity of Applied Sciences Würzburg‐SchweinfurtSchweinfurtGermany
| | - Jeremy B. A. Green
- Centre for Craniofacial & Regenerative Biology, Faculty of Dentistry, Oral & Craniofacial SciencesKing's College LondonUK
| | - Thomas Schwarz
- Translational Center Regenerative TherapiesFraunhofer Institute for Silicate Research ISCWürzburgGermany
| | - Kamal Mustafa
- Center of Translational Oral Research (TOR)‐Tissue Engineering Group, Department of Clinical Dentistry, Faculty of MedicineUniversity of BergenNorway
| |
Collapse
|
2
|
Najmina M, Ebara M, Ohmura T, Uto K. Viscoelastic Liquid Matrix with Faster Bulk Relaxation Time Reinforces the Cell Cycle Arrest Induction of the Breast Cancer Cells via Oxidative Stress. Int J Mol Sci 2022; 23:ijms232314637. [PMID: 36498966 PMCID: PMC9736955 DOI: 10.3390/ijms232314637] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/18/2022] [Accepted: 11/20/2022] [Indexed: 11/25/2022] Open
Abstract
The reactivating of disseminated dormant breast cancer cells in a soft viscoelastic matrix is mostly correlated with metastasis. Metastasis occurs due to rapid stress relaxation owing to matrix remodeling. Here, we demonstrate the possibility of promoting the permanent cell cycle arrest of breast cancer cells on a viscoelastic liquid substrate. By controlling the molecular weight of the hydrophobic molten polymer, poly(ε-caprolactone-co-D,L-lactide) within 35-63 g/mol, this study highlights that MCF7 cells can sense a 1000 times narrower relaxation time range (80-290 ms) compared to other studies by using a crosslinked hydrogel system. We propose that the rapid bulk relaxation response of the substrate promotes more reactive oxygen species generation in the formed semi-3D multicellular aggregates of breast cancer cells. Our finding sheds light on the potential role of bulk stress relaxation in a viscous-dominant viscoelastic matrix in controlling the cell cycle arrest depth of breast cancer cells.
Collapse
Affiliation(s)
- Mazaya Najmina
- Research Center for Functional Materials, National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044, Japan
- Graduate School of Science and Engineering, University of Tsukuba, 1-1 Tennodai, Tsukuba 305-8577, Japan
| | - Mitsuhiro Ebara
- Research Center for Functional Materials, National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044, Japan
- Graduate School of Science and Engineering, University of Tsukuba, 1-1 Tennodai, Tsukuba 305-8577, Japan
- Graduate School of Industrial Science, Tokyo University of Science, 1-3 Kagurazaka, Shinjuku, Tokyo 162-8601, Japan
| | - Takahito Ohmura
- Research Center for Structural Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047, Japan
| | - Koichiro Uto
- Research Center for Functional Materials, National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044, Japan
- Correspondence:
| |
Collapse
|
3
|
Wang F, Metzner F, Osterhoff G, Zheng L, Schleifenbaum S. The role of bone marrow on the mechanical properties of trabecular bone: a systematic review. Biomed Eng Online 2022; 21:80. [PMID: 36419171 PMCID: PMC9686043 DOI: 10.1186/s12938-022-01051-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 11/10/2022] [Indexed: 11/26/2022] Open
Abstract
Background Accurate evaluation of the mechanical properties of trabecular bone is important, in which the internal bone marrow plays an important role. The aim of this systematic review is to investigate the roles of bone marrow on the mechanical properties of trabecular bone to better support clinical work and laboratory research. Methods A systematic review of the literature published up to June 2022 regarding the role of bone marrow on the mechanical properties of trabecular bone was performed, using PubMed and Web of Science databases. The journal language was limited to English. A total of 431 articles were selected from PubMed (n = 186), Web of Science (n = 244) databases, and other sources (n = 1). Results After checking, 38 articles were finally included in this study. Among them, 27 articles discussed the subject regarding the hydraulic stiffening of trabecular bone due to the presence of bone marrow. Nine of them investigated the effects of bone marrow on compression tests with different settings, i.e., in vitro experiments under unconfined and confined conditions, and computer model simulations. Relatively few controlled studies reported the influence of bone marrow on the shear properties of trabecular bone. Conclusion Bone marrow plays a non-neglectable role in the mechanical properties of trabecular bone, its contribution varies depending on the different loading types and test settings. To obtain the mechanical properties of trabecular bone comprehensively and accurately, the solid matrix (trabeculae) and fluid-like component (bone marrow) should be considered in parallel rather than tested separately. Supplementary Information The online version contains supplementary material available at 10.1186/s12938-022-01051-1.
Collapse
Affiliation(s)
- Fangxing Wang
- grid.9647.c0000 0004 7669 9786ZESBO - Center for Research on Musculoskeletal Systems, Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Semmelweisstraße 14, 04103 Leipzig, Germany ,grid.9647.c0000 0004 7669 9786Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße 20 Haus 4, 04103 Leipzig, Germany
| | - Florian Metzner
- grid.9647.c0000 0004 7669 9786ZESBO - Center for Research on Musculoskeletal Systems, Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Semmelweisstraße 14, 04103 Leipzig, Germany ,grid.9647.c0000 0004 7669 9786Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße 20 Haus 4, 04103 Leipzig, Germany
| | - Georg Osterhoff
- grid.9647.c0000 0004 7669 9786Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße 20 Haus 4, 04103 Leipzig, Germany
| | - Leyu Zheng
- grid.9647.c0000 0004 7669 9786Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße 20 Haus 4, 04103 Leipzig, Germany
| | - Stefan Schleifenbaum
- grid.9647.c0000 0004 7669 9786ZESBO - Center for Research on Musculoskeletal Systems, Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Semmelweisstraße 14, 04103 Leipzig, Germany ,grid.9647.c0000 0004 7669 9786Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße 20 Haus 4, 04103 Leipzig, Germany
| |
Collapse
|
4
|
Matrix biophysical cues direct mesenchymal stromal cell functions in immunity. Acta Biomater 2021; 133:126-138. [PMID: 34365041 DOI: 10.1016/j.actbio.2021.07.075] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 07/14/2021] [Accepted: 07/30/2021] [Indexed: 12/25/2022]
Abstract
Hydrogels have been used to design synthetic matrices that capture salient features of matrix microenvironments to study and control cellular functions. Recent advances in understanding of both extracellular matrix biology and biomaterial design have shown that biophysical cues are powerful mediators of cell biology, especially that of mesenchymal stromal cells (MSCs). MSCs have been tested in many clinical trials because of their ability to modulate immune cells in different pathological conditions. While roles of biophysical cues in MSC biology have been studied in the context of multilineage differentiation, their significance in regulating immunomodulatory functions of MSCs is just beginning to be elucidated. This review first describes design principles behind how biophysical cues in native microenvironments influence the ability of MSCs to regulate immune cell production and functions. We will then discuss how biophysical cues can be leveraged to optimize cell isolation, priming, and delivery, which can help improve the success of MSC therapy for immunomodulation. Finally, a perspective is presented on how implementing biophysical cues in MSC potency assay can be important in predicting clinical outcomes. STATEMENT OF SIGNIFICANCE: Stromal cells of mesenchymal origin are known to direct immune cell functions in vivo by secreting paracrine mediators. This property has been leveraged in developing mesenchymal stromal cell (MSC)-based therapeutics by adoptive transfer to treat immunological rejection and tissue injuries, which have been tested in over one thousand clinical trials to date, but with mixed success. Advances in biomaterial design have enabled precise control of biophysical cues based on how stromal cells interact with the extracellular matrix in microenvironments in situ. Investigators have begun to use this approach to understand how different matrix biophysical parameters, such as fiber orientation, porosity, dimensionality, and viscoelasticity impact stromal cell-mediated immunomodulation. The insights gained from this effort can potentially be used to precisely define the microenvironmental cues for isolation, priming, and delivery of MSCs, which can be tailored based on different disease indications for optimal therapeutic outcomes.
Collapse
|
5
|
Moore CA, Siddiqui Z, Carney GJ, Naaldijk Y, Guiro K, Ferrer AI, Sherman LS, Guvendiren M, Kumar VA, Rameshwar P. A 3D Bioprinted Material That Recapitulates the Perivascular Bone Marrow Structure for Sustained Hematopoietic and Cancer Models. Polymers (Basel) 2021; 13:480. [PMID: 33546275 PMCID: PMC7913313 DOI: 10.3390/polym13040480] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 01/28/2021] [Accepted: 01/29/2021] [Indexed: 12/11/2022] Open
Abstract
Translational medicine requires facile experimental systems to replicate the dynamic biological systems of diseases. Drug approval continues to lag, partly due to incongruencies in the research pipeline that traditionally involve 2D models, which could be improved with 3D models. The bone marrow (BM) poses challenges to harvest as an intact organ, making it difficult to study disease processes such as breast cancer (BC) survival in BM, and to effective evaluation of drug response in BM. Furthermore, it is a challenge to develop 3D BM structures due to its weak physical properties, and complex hierarchical structure and cellular landscape. To address this, we leveraged 3D bioprinting to create a BM structure with varied methylcellulose (M): alginate (A) ratios. We selected hydrogels containing 4% (w/v) M and 2% (w/v) A, which recapitulates rheological and ultrastructural features of the BM while maintaining stability in culture. This hydrogel sustained the culture of two key primary BM microenvironmental cells found at the perivascular region, mesenchymal stem cells and endothelial cells. More importantly, the scaffold showed evidence of cell autonomous dedifferentiation of BC cells to cancer stem cell properties. This scaffold could be the platform to create BM models for various diseases and also for drug screening.
Collapse
Affiliation(s)
- Caitlyn A. Moore
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
- Department of Medicine, Rutgers School of Graduate Studies, New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA
| | - Zain Siddiqui
- Department of Biomedical Engineering, New Jersey Institute of Technology, 323 Martin Luther King Jr. Blvd, Newark, NJ 07102, USA; (Z.S.); (M.G.); (V.A.K.)
| | - Griffin J. Carney
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
| | - Yahaira Naaldijk
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
| | - Khadidiatou Guiro
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
| | - Alejandra I. Ferrer
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
- Department of Medicine, Rutgers School of Graduate Studies, New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA
| | - Lauren S. Sherman
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
- Department of Medicine, Rutgers School of Graduate Studies, New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA
| | - Murat Guvendiren
- Department of Biomedical Engineering, New Jersey Institute of Technology, 323 Martin Luther King Jr. Blvd, Newark, NJ 07102, USA; (Z.S.); (M.G.); (V.A.K.)
- Department of Chemical, Biological and Pharmaceutical Engineering, New Jersey Institute of Technology, 323 Martin Luther King Jr. Blvd, Newark, NJ 07102, USA
| | - Vivek A. Kumar
- Department of Biomedical Engineering, New Jersey Institute of Technology, 323 Martin Luther King Jr. Blvd, Newark, NJ 07102, USA; (Z.S.); (M.G.); (V.A.K.)
- Department of Chemical, Biological and Pharmaceutical Engineering, New Jersey Institute of Technology, 323 Martin Luther King Jr. Blvd, Newark, NJ 07102, USA
- Department of Restorative Dentistry, Rutgers School of Dental Medicine, 110 Bergen St, Newark, NJ 07103, USA
| | - Pranela Rameshwar
- Department of Medicine, Rutgers New Jersey Medical School, 185 South Orange Avenue, Newark, NJ 07103, USA; (C.A.M.); (G.J.C.); (Y.N.); (K.G.); (A.I.F.); (L.S.S.)
| |
Collapse
|
6
|
The extracellular matrix: A key player in the pathogenesis of hematologic malignancies. Blood Rev 2020; 48:100787. [PMID: 33317863 DOI: 10.1016/j.blre.2020.100787] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 09/10/2020] [Accepted: 11/05/2020] [Indexed: 12/26/2022]
Abstract
Hematopoietic stem and progenitor cells located in the bone marrow lay the foundation for multiple lineages of mature hematologic cells. Bone marrow niches are architecturally complex with specific cellular, physiochemical, and biomechanical factors. Increasing evidence suggests that the bone marrow microenvironment contributes to the pathogenesis of hematological neoplasms. Numerous studies have deciphered the role of genetic mutations and chromosomal translocations in the development hematologic malignancies. Significant progress has also been made in understanding how the cellular components and cytokine interactions within the bone marrow microenvironment promote the evolution of hematologic cancers. Although the extracellular matrix is known to be a key player in the pathogenesis of various diseases, it's role in the progression of hematologic malignancies is less understood. In this review, we discuss the interactions between the extracellular matrix and malignant cells, and provide an overview of the role of extracellular matrix remodeling in sustaining hematologic malignancies.
Collapse
|
7
|
Chen X, Hughes R, Mullin N, Hawkins RJ, Holen I, Brown NJ, Hobbs JK. Mechanical Heterogeneity in the Bone Microenvironment as Characterized by Atomic Force Microscopy. Biophys J 2020; 119:502-513. [PMID: 32668233 PMCID: PMC7401034 DOI: 10.1016/j.bpj.2020.06.026] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 06/19/2020] [Accepted: 06/26/2020] [Indexed: 01/09/2023] Open
Abstract
Bones are structurally heterogeneous organs with diverse functions that undergo mechanical stimuli across multiple length scales. Mechanical characterization of the bone microenvironment is important for understanding how bones function in health and disease. Here, we describe the mechanical architecture of cortical bone, the growth plate, metaphysis, and marrow in fresh murine bones, probed using atomic force microscopy in physiological buffer. Both elastic and viscoelastic properties are found to be highly heterogeneous with moduli ranging over three to five orders of magnitude, both within and across regions. All regions include extremely compliant areas, with moduli of a few pascal and viscosities as low as tens of Pa·s. Aging impacts the viscoelasticity of the bone marrow strongly but has a limited effect on the other regions studied. Our approach provides the opportunity to explore the mechanical properties of complex tissues at the length scale relevant to cellular processes and how these impact aging and disease.
Collapse
Affiliation(s)
- Xinyue Chen
- Department of Physics and Astronomy, University of Sheffield, Sheffield, United Kingdom; Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom; The Krebs Institute, University of Sheffield, Sheffield, United Kingdom
| | - Russell Hughes
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom
| | - Nic Mullin
- Department of Physics and Astronomy, University of Sheffield, Sheffield, United Kingdom; The Krebs Institute, University of Sheffield, Sheffield, United Kingdom
| | - Rhoda J Hawkins
- Department of Physics and Astronomy, University of Sheffield, Sheffield, United Kingdom; The Krebs Institute, University of Sheffield, Sheffield, United Kingdom
| | - Ingunn Holen
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom
| | - Nicola J Brown
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom
| | - Jamie K Hobbs
- Department of Physics and Astronomy, University of Sheffield, Sheffield, United Kingdom; The Krebs Institute, University of Sheffield, Sheffield, United Kingdom.
| |
Collapse
|
8
|
Wong SW, Lenzini S, Cooper MH, Mooney DJ, Shin JW. Soft extracellular matrix enhances inflammatory activation of mesenchymal stromal cells to induce monocyte production and trafficking. SCIENCE ADVANCES 2020; 6:eaaw0158. [PMID: 32284989 PMCID: PMC7141831 DOI: 10.1126/sciadv.aaw0158] [Citation(s) in RCA: 63] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 01/14/2020] [Indexed: 05/17/2023]
Abstract
Mesenchymal stromal cells (MSCs) modulate immune cells to ameliorate multiple inflammatory pathologies. Biophysical signals that regulate this process are poorly defined. By engineering hydrogels with tunable biophysical parameters relevant to bone marrow where MSCs naturally reside, we show that soft extracellular matrix maximizes the ability of MSCs to produce paracrine factors that have been implicated in monocyte production and chemotaxis upon inflammatory stimulation by tumor necrosis factor-α (TNFα). Soft matrix increases clustering of TNF receptors, thereby enhancing NF-κB activation and downstream gene expression. Actin polymerization and lipid rafts, but not myosin-II contractility, regulate mechanosensitive activation of MSCs by TNFα. We functionally demonstrate that human MSCs primed with TNFα in soft matrix enhance production of human monocytes in marrow of xenografted mice and increase trafficking of monocytes via CCL2. The results suggest the importance of biophysical signaling in tuning inflammatory activation of stromal cells to control the innate immune system.
Collapse
Affiliation(s)
- Sing Wan Wong
- Department of Pharmacology and Department of Bioengineering, University of Illinois at Chicago College of Medicine, Chicago, IL, USA
| | - Stephen Lenzini
- Department of Pharmacology and Department of Bioengineering, University of Illinois at Chicago College of Medicine, Chicago, IL, USA
| | - Madeline H. Cooper
- School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - David J. Mooney
- School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Jae-Won Shin
- Department of Pharmacology and Department of Bioengineering, University of Illinois at Chicago College of Medicine, Chicago, IL, USA
| |
Collapse
|
9
|
Curtis KJ, Oberman AG, Niebur GL. Effects of mechanobiological signaling in bone marrow on skeletal health. Ann N Y Acad Sci 2019; 1460:11-24. [PMID: 31508828 DOI: 10.1111/nyas.14232] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 08/09/2019] [Accepted: 08/15/2019] [Indexed: 01/27/2023]
Abstract
Bone marrow is a cellular tissue that forms within the pore space and hollow diaphysis of bones. As a tissue, its primary function is to support the hematopoietic progenitor cells that maintain the populations of both erythroid and myeloid lineage cells in the bone marrow, making it an essential element of normal mammalian physiology. However, bone's primary function is load bearing, and deformations induced by external forces are transmitted to the encapsulated marrow. Understanding the effects of these mechanical inputs on marrow function and adaptation requires knowledge of the material behavior of the marrow at multiple scales, the loads that are applied, and the mechanobiology of the cells. This paper reviews the current state of knowledge of each of these factors. Characterization of the marrow mechanical environment and its role in skeletal health and other marrow functions remains incomplete, but research on the topic is increasing, driven by interest in skeletal adaptation and the mechanobiology of cancer metastasis.
Collapse
Affiliation(s)
- Kimberly J Curtis
- Tissue Mechanics Laboratory, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana.,Advanced Diagnostics and Therapeutics Initiative, University of Notre Dame, Notre Dame, Indiana
| | - Alyssa G Oberman
- Tissue Mechanics Laboratory, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana
| | - Glen L Niebur
- Tissue Mechanics Laboratory, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana.,Harper Cancer Research Institute, University of Notre Dame, Notre Dame, Indiana.,Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, Indiana
| |
Collapse
|
10
|
Discrete particle model for cement infiltration within open-cell structures: Prevention of osteoporotic fracture. PLoS One 2018; 13:e0199035. [PMID: 29898001 PMCID: PMC5999107 DOI: 10.1371/journal.pone.0199035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Accepted: 05/30/2018] [Indexed: 11/19/2022] Open
Abstract
This paper proposes a discrete particle model based on the random-walk theory for simulating cement infiltration within open-cell structures to prevent osteoporotic proximal femur fractures. Model parameters consider the cement viscosity (high and low) and the desired direction of injection (vertical and diagonal). In vitro and in silico characterizations of augmented open-cell structures validated the computational model and quantified the improved mechanical properties (Young's modulus) of the augmented specimens. The cement injection pattern was successfully predicted in all the simulated cases. All the augmented specimens exhibited enhanced mechanical properties computationally and experimentally (maximum improvements of 237.95 ± 12.91% and 246.85 ± 35.57%, respectively). The open-cell structures with high porosity fraction showed a considerable increase in mechanical properties. Cement augmentation in low porosity fraction specimens resulted in a lesser increase in mechanical properties. The results suggest that the proposed discrete particle model is adequate for use as a femoroplasty planning framework.
Collapse
|
11
|
Wong SW, Lenzini S, Shin JW. Perspective: Biophysical regulation of cancerous and normal blood cell lineages in hematopoietic malignancies. APL Bioeng 2018; 2:031802. [PMID: 31069313 PMCID: PMC6324213 DOI: 10.1063/1.5025689] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 05/04/2018] [Indexed: 01/15/2023] Open
Abstract
It is increasingly appreciated that physical forces play important roles in cancer biology, in terms of progression, invasiveness, and drug resistance. Clinical progress in treating hematological malignancy and in developing cancer immunotherapy highlights the role of the hematopoietic system as a key model in devising new therapeutic strategies against cancer. Understanding mechanobiology of the hematopoietic system in the context of cancer will thus yield valuable fundamental insights that can information about novel cancer therapeutics. In this perspective, biophysical insights related to blood cancer are defined and detailed. The interactions with immune cells relevant to immunotherapy against cancer are considered and expounded, followed by speculation of potential regulatory roles of mesenchymal stromal cells (MSCs) in this complex network. Finally, a perspective is presented as to how insights from these complex interactions between matrices, blood cancer cells, immune cells, and MSCs can be leveraged to influence and engineer the treatment of blood cancers in the clinic.
Collapse
Affiliation(s)
- Sing Wan Wong
- Department of Pharmacology, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, USA and Department of Bioengineering, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, USA
| | - Stephen Lenzini
- Department of Pharmacology, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, USA and Department of Bioengineering, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, USA
| | - Jae-Won Shin
- Department of Pharmacology, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, USA and Department of Bioengineering, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, USA
| |
Collapse
|
12
|
Altered architecture and cell populations affect bone marrow mechanobiology in the osteoporotic human femur. Biomech Model Mechanobiol 2016; 16:841-850. [DOI: 10.1007/s10237-016-0856-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Accepted: 11/11/2016] [Indexed: 10/20/2022]
|
13
|
Metzger TA, Kreipke TC, Vaughan TJ, McNamara LM, Niebur GL. The in situ mechanics of trabecular bone marrow: the potential for mechanobiological response. J Biomech Eng 2015; 137:1926231. [PMID: 25363343 DOI: 10.1115/1.4028985] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Accepted: 11/05/2014] [Indexed: 11/08/2022]
Abstract
Bone adapts to habitual loading through mechanobiological signaling. Osteocytes are the primary mechanical sensors in bone, upregulating osteogenic factors and downregulating osteoinhibitors, and recruiting osteoclasts to resorb bone in response to microdamage accumulation. However, most of the cell populations of the bone marrow niche,which are intimately involved with bone remodeling as the source of bone osteoblast and osteoclast progenitors, are also mechanosensitive. We hypothesized that the deformation of trabecular bone would impart mechanical stress within the entrapped bone marrow consistent with mechanostimulation of the constituent cells. Detailed fluid-structure interaction models of porcine femoral trabecular bone and bone marrow were created using tetrahedral finite element meshes. The marrow was allowed to flow freely within the bone pores, while the bone was compressed to 2000 or 3000 microstrain at the apparent level.Marrow properties were parametrically varied from a constant 400 mPas to a power law rule exceeding 85 Pas. Deformation generated almost no shear stress or pressure in the marrow for the low viscosity fluid, but exceeded 5 Pa when the higher viscosity models were used. The shear stress was higher when the strain rate increased and in higher volume fraction bone. The results demonstrate that cells within the trabecular bone marrow could be mechanically stimulated by bone deformation, depending on deformation rate, bone porosity, and bone marrow properties. Since the marrow contains many mechanosensitive cells, changes in the stimulatory levels may explain the alterations in bone marrow morphology with aging and disease, which may in turn affect the trabecular bone mechanobiology and adaptation.
Collapse
|
14
|
Jansen LE, Birch NP, Schiffman JD, Crosby AJ, Peyton SR. Mechanics of intact bone marrow. J Mech Behav Biomed Mater 2015; 50:299-307. [PMID: 26189198 DOI: 10.1016/j.jmbbm.2015.06.023] [Citation(s) in RCA: 114] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Revised: 06/22/2015] [Accepted: 06/23/2015] [Indexed: 01/08/2023]
Abstract
The current knowledge of bone marrow mechanics is limited to its viscous properties, neglecting the elastic contribution of the extracellular matrix. To get a more complete view of the mechanics of marrow, we characterized intact yellow porcine bone marrow using three different, but complementary techniques: rheology, indentation, and cavitation. Our analysis shows that bone marrow is elastic, and has a large amount of intra- and inter-sample heterogeneity, with an effective Young׳s modulus ranging from 0.25 to 24.7 kPa at physiological temperature. Each testing method was consistent across matched tissue samples, and each provided unique benefits depending on user needs. We recommend bulk rheology to capture the effects of temperature on tissue elasticity and moduli, indentation for quantifying local tissue heterogeneity, and cavitation rheology for mitigating destructive sample preparation. We anticipate the knowledge of bone marrow elastic properties for building in vitro models will elucidate mechanisms involved in disease progression and regenerative medicine.
Collapse
Affiliation(s)
- Lauren E Jansen
- Department of Chemical Engineering, University of Massachusetts Amherst, 686 N Pleasant Street, 159 Goessmann Hall, Amherst, MA 01003, USA
| | - Nathan P Birch
- Department of Chemical Engineering, University of Massachusetts Amherst, 686 N Pleasant Street, 159 Goessmann Hall, Amherst, MA 01003, USA
| | - Jessica D Schiffman
- Department of Chemical Engineering, University of Massachusetts Amherst, 686 N Pleasant Street, 159 Goessmann Hall, Amherst, MA 01003, USA
| | - Alfred J Crosby
- Polymer Science and Engineering Department, University of Massachusetts Amherst, 120 Governors Dr., Amherst, MA 01003, USA
| | - Shelly R Peyton
- Department of Chemical Engineering, University of Massachusetts Amherst, 686 N Pleasant Street, 159 Goessmann Hall, Amherst, MA 01003, USA.
| |
Collapse
|
15
|
Vaughan TJ, Voisin M, Niebur GL, McNamara LM. Multiscale Modeling of Trabecular Bone Marrow: Understanding the Micromechanical Environment of Mesenchymal Stem Cells During Osteoporosis. J Biomech Eng 2015; 137:1926230. [DOI: 10.1115/1.4028986] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2014] [Accepted: 11/05/2014] [Indexed: 01/14/2023]
Abstract
Mechanical loading directs the differentiation of mesenchymal stem cells (MSCs) in vitro and it has been hypothesized that the mechanical environment plays a role in directing the cellular fate of MSCs in vivo. However, the complex multicellular composition of trabecular bone marrow means that the precise nature of mechanical stimulation that MSCs experience in their native environment is not fully understood. In this study, we developed a multiscale model that discretely represents the cellular constituents of trabecular bone marrow and applied this model to characterize mechanical stimulation of MCSs in vivo. We predicted that cell-level strains in certain locations of the trabecular marrow microenvironment were greater in magnitude (maximum ε12 = ∼24,000 με) than levels that have been found to result in osteogenic differentiation of MSCs in vitro (>8000 με), which may indicate that the native mechanical environment of MSCs could direct cellular fate in vivo. The results also showed that cell–cell adhesions could play an important role in mediating mechanical stimulation within the MSC population in vivo. The model was applied to investigate how changes that occur during osteoporosis affected mechanical stimulation in the cellular microenvironment of trabecular bone marrow. Specifically, a reduced bone volume (BV) resulted in an overall increase in bone deformation, leading to greater cell-level mechanical stimulation in trabecular bone marrow (maximum ε12 = ∼48,000 με). An increased marrow adipocyte content resulted in slightly lower levels of stimulation within the adjacent cell population due to a shielding effect caused by the more compliant behavior of adipocytes (maximum ε12 = ∼41,000 με). Despite this reduction, stimulation levels in trabecular bone marrow during osteoporosis remained much higher than those predicted to occur under healthy conditions. It was found that compensatory mechanobiological responses that occur during osteoporosis, such as increased trabecular stiffness and axial alignment of trabeculae, would be effective in returning MSC stimulation in trabecular marrow to normal levels. These results have provided novel insight into the mechanical stimulation of the trabecular marrow MSC population in both healthy and osteoporotic bone, and could inform the design three-dimensional (3D) in vitro bioreactor strategies techniques, which seek to emulate physiological conditions.
Collapse
Affiliation(s)
- T. J. Vaughan
- Biomechanics Research Centre (BMEC), Biomedical Engineering, National University of Ireland, Galway, Ireland
| | - M. Voisin
- Biomechanics Research Centre (BMEC), Biomedical Engineering, National University of Ireland, Galway, Ireland
| | - G. L. Niebur
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556
| | - L. M. McNamara
- Biomechanics Research Centre (BMEC), Biomedical Engineering, National University of Ireland, Galway, Ireland e-mail:
| |
Collapse
|
16
|
Janeczek AA, Scarpa E, A. Newman T, Oreffo ROC, S. Tare R, Evans ND. Skeletal Stem Cell Niche of the Bone Marrow. TISSUE-SPECIFIC STEM CELL NICHE 2015. [DOI: 10.1007/978-3-319-21705-5_11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
17
|
Birmingham E, Kreipke TC, Dolan EB, Coughlin TR, Owens P, McNamara LM, Niebur GL, McHugh PE. Mechanical stimulation of bone marrow in situ induces bone formation in trabecular explants. Ann Biomed Eng 2014; 43:1036-50. [PMID: 25281407 DOI: 10.1007/s10439-014-1135-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Accepted: 09/20/2014] [Indexed: 11/25/2022]
Abstract
Low magnitude high frequency (LMHF) loading has been shown to have an anabolic effect on trabecular bone in vivo. However, the precise mechanical signal imposed on the bone marrow cells by LMHF loading, which induces a cellular response, remains unclear. This study investigates the influence of LMHF loading, applied using a custom designed bioreactor, on bone adaptation in an explanted trabecular bone model, which isolated the bone and marrow. Bone adaptation was investigated by performing micro CT scans pre and post experimental LMHF loading, using image registration techniques. Computational fluids dynamic models were generated using the pre-experiment scans to characterise the mechanical stimuli imposed by the loading regime prior to adaptation. Results here demonstrate a significant increase in bone formation in the LMHF loaded group compared to static controls and media flow groups. The calculated shear stress in the marrow was between 0.575 and 0.7 Pa, which is within the range of stimuli known to induce osteogenesis by bone marrow mesenchymal stem cells in vitro. Interestingly, a correlation was found between the bone formation balance (bone formation/resorption), trabecular number, trabecular spacing, mineral resorption rate, bone resorption rate and mean shear stresses. The results of this study suggest that the magnitude of the shear stresses generated due to LMHF loading in the explanted bone cores has a contributory role in the formation of trabecular bone and improvement in bone architecture parameters.
Collapse
Affiliation(s)
- E Birmingham
- Biomechanics Research Centre (BMEC), Mechanical and Biomedical Engineering, College of Engineering and Informatics, National University of Ireland Galway, 2nd Floor Engineering Building, Galway, Ireland,
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Scorza A, Battista L, Silvestri S, Sciuto SA. Design and development of a rheometer for biological fluids of limited availability. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:105105. [PMID: 25362454 DOI: 10.1063/1.4897490] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
From studies on the dynamic characterization of human bones, it is noticed that reference data on the viscous behavior of the bone marrow are quite poor. Dependently from marrow limited availability and its opacity, we have not been able to retrieve a tool of appropriate characteristics able to measure bone marrow viscosity. Therefore, principal techniques for the viscosity measurement have been preliminarily examined, and a device suitable for viscosity measurements of biological fluids has been realized. In particular, a rotational rheometer has been developed: it is a coaxial cylinders system, where the fluid flows dragged by the inner cylinder. The device is an absolute rheometer, that is, particularly useful as nowadays it is not known the classification of the bone as far as it concerns its viscous behavior. In this work a preliminary evaluation of the metrological characteristics of the measurement system has been carried out and its main metrological performances have been evaluated.
Collapse
Affiliation(s)
- A Scorza
- Department of Engineering, Roma TRE University, via della Vasca Navale 79/81, 00146 Roma, Italy
| | - L Battista
- Clinical Engineering Service, Religious General Hospital "F. Miulli," Acquaviva delle Fonti (BA), Italy
| | - S Silvestri
- Unit of Measurements and Biomedical Instrumentation, Center for Integrated Research, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Roma, Italy
| | - S A Sciuto
- Department of Engineering, Roma TRE University, via della Vasca Navale 79/81, 00146 Roma, Italy
| |
Collapse
|
19
|
Bou-Francis A, López A, Persson C, Hall RM, Kapur N. Assessing cement injection behaviour in cancellous bone: An in vitro study using flow models. J Biomater Appl 2014; 29:582-94. [DOI: 10.1177/0885328214537858] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Understanding the cement injection behaviour during vertebroplasty and accurately predicting the cement placement within the vertebral body is extremely challenging. As there is no standardized methodology, we propose a novel method using reproducible and pathologically representative flow models to study the influence of cement properties on injection behaviour. The models, confined between an upper glass window and a lower aluminium plate, were filled with bone marrow substitute and then injected (4, 6 and 8 min after cement mixing) with commercially available bone cements (SimplexP, Opacity+, OsteopalV and Parallax) at a constant flow rate (3 mL/min). A load cell was used to measure the force applied on the syringe plunger and calculate the peak pressure. A camera was used to monitor the cement flow during injection and calculate the following parameters when the cement had reached the boundary of the models: the time to reach the boundary, the filled area and the roundness. The peak pressure was comparable to that reported during clinical vertebroplasty and showed a similar increase with injection time. The study highlighted the influence of cement formulations and model structure on the injection behaviour and showed that cements with similar composition/particle size had similar flow behaviour, while the introduction of defects reduced the time to reach the boundary, the filled area and the roundness. The proposed method provides a novel tool for quick, robust differentiation between various cement formulations through the visualization and quantitative analysis of the cement spreading at various time intervals.
Collapse
Affiliation(s)
| | - Alejandro López
- Department of Engineering Sciences, Uppsala University, Sweden
| | - Cecilia Persson
- Department of Engineering Sciences, Uppsala University, Sweden
| | - Richard M Hall
- School of Mechanical Engineering, University of Leeds, UK
| | - Nikil Kapur
- School of Mechanical Engineering, University of Leeds, UK
| |
Collapse
|
20
|
A Particle Model for Prediction of Cement Infiltration of Cancellous Bone in Osteoporotic Bone Augmentation. PLoS One 2013; 8:e67958. [PMID: 23840794 PMCID: PMC3693961 DOI: 10.1371/journal.pone.0067958] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Accepted: 05/23/2013] [Indexed: 11/25/2022] Open
Abstract
Femoroplasty is a potential preventive treatment for osteoporotic hip fractures. It involves augmenting mechanical properties of the femur by injecting Polymethylmethacrylate (PMMA) bone cement. To reduce the risks involved and maximize the outcome, however, the procedure needs to be carefully planned and executed. An important part of the planning system is predicting infiltration of cement into the porous medium of cancellous bone. We used the method of Smoothed Particle Hydrodynamics (SPH) to model the flow of PMMA inside porous media. We modified the standard formulation of SPH to incorporate the extreme viscosities associated with bone cement. Darcy creeping flow of fluids through isotropic porous media was simulated and the results were compared with those reported in the literature. Further validation involved injecting PMMA cement inside porous foam blocks — osteoporotic cancellous bone surrogates — and simulating the injections using our proposed SPH model. Millimeter accuracy was obtained in comparing the simulated and actual cement shapes. Also, strong correlations were found between the simulated and the experimental data of spreading distance (R2 = 0.86) and normalized pressure (R2 = 0.90). Results suggest that the proposed model is suitable for use in an osteoporotic femoral augmentation planning framework.
Collapse
|
21
|
Computational Modelling of the Mechanics of Trabecular Bone and Marrow Using Fluid Structure Interaction Techniques. Ann Biomed Eng 2012; 41:814-26. [DOI: 10.1007/s10439-012-0714-1] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Accepted: 11/26/2012] [Indexed: 10/27/2022]
|