1
|
Roser CJ, Rückschloß T, Zenthöfer A, Rammelsberg P, Lux CJ, Rues S. Orthodontic shear bond strength and ultimate load tests of CAD/CAM produced artificial teeth. Clin Oral Investig 2022; 26:7149-7155. [PMID: 35982349 DOI: 10.1007/s00784-022-04676-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 08/10/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To investigate whether artificial CAD/CAM processed (computer-aided design/manufacturing) teeth could be a feasible option for the production of dental in vitro models for biomechanical testing. MATERIAL AND METHODS Disks (n = 10 per group) made from two different CAD/CAM-materials, one fiber-reinforced composite (FRC; Trinia, Bicon) and one polymethylmethacrylate-based resin (PMMA; Telio CAD, Ivoclar Vivadent), as well as bovine teeth (n = 10), were tested for their shear bond strength (SBS) and scored according to the adhesive remnant index (ARI). In addition, CAD/CAM-manufactured lower incisor teeth were tested for their ultimate load (Fu). RESULTS With regard to SBS, both PMMA (17.4 ± 2.2 MPa) and FRC (18.0 ± 2.4 MPa) disks showed no significant difference (p = 0.968) compared to bovine disks (18.0 ± 5.4 MPa). However, the samples differed with regard to their failure mode (PMMA: ARI 4, delamination failure; FRC: ARI 0 and bovine: ARI 1.6, both adhesive failure). With regard to Fu, FRC-based teeth could withstand significantly higher loads (708 ± 126 N) than PMMA-based teeth (345 ± 109 N) (p < 0.01). CONCLUSION Unlike PMMA-based teeth, teeth made from FRC showed sufficiently high fracture resistance and comparable SBS. Thus, FRC teeth could be a promising alternative for the production of dental in vitro models for orthodontic testing. CLINICAL RELEVANCE CAD/CAM-processed teeth made from FRC enable the use of standardized geometry and constant material properties. Using FRC teeth in dental in vitro studies has therefore the potential to identify differences between various treatment options with rather small sample sizes, while remaining close to the clinical situation.
Collapse
Affiliation(s)
- Christoph J Roser
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Thomas Rückschloß
- Department of Oral and Maxillofacial Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Andreas Zenthöfer
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Im Neuenheimer Feld 400, Heidelberg, Germany
| | - Peter Rammelsberg
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Im Neuenheimer Feld 400, Heidelberg, Germany
| | - Christopher J Lux
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Stefan Rues
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Im Neuenheimer Feld 400, Heidelberg, Germany
| |
Collapse
|
2
|
Scribante A, Vallittu PK, Özcan M, Lassila LVJ, Gandini P, Sfondrini MF. Travel beyond Clinical Uses of Fiber Reinforced Composites (FRCs) in Dentistry: A Review of Past Employments, Present Applications, and Future Perspectives. BIOMED RESEARCH INTERNATIONAL 2018; 2018:1498901. [PMID: 30426003 PMCID: PMC6217899 DOI: 10.1155/2018/1498901] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 10/02/2018] [Indexed: 12/17/2022]
Abstract
The reinforcement of resins with short or long fibers has multiple applications in various engineering and biomedical fields. The use of fiber reinforced composites (FRCs) in dentistry has been described in the literature from more than 40 years. In vitro studies evaluated mechanical properties such as flexural strength, fatigue resistance, fracture strength, layer thickness, bacterial adhesion, bonding characteristics with long fibers, woven fibers, and FRC posts. Also, multiple clinical applications such as replacement of missing teeth by resin-bonded adhesive fixed dental prostheses of various kinds, reinforcement elements of dentures or pontics, and direct construction of posts and cores have been investigated. In orthodontics, FRCs have been used also for active and passive orthodontic applications, such as anchorage units, en-masse movement units, and postorthodontic tooth retention. FRCs have been extensively tested in the literature, but today the advances in new technologies involving the introduction of nanofillers or new fibers along with understanding the design principles of FRC devices open new fields of research for these materials both in vitro and in vivo. The present review describes past and present applications of FRCs and introduces some future perspectives on the use of these materials.
Collapse
Affiliation(s)
- Andrea Scribante
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Italy
| | - Pekka K. Vallittu
- Department of Biomaterial Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku, Turku, Finland
- City of Turku, Welfare Division, Turku, Finland
| | - Mutlu Özcan
- University of Zurich, Center for Dental and Oral Medicine, Dental Materials Unit, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, Zurich, Switzerland
| | - Lippo V. J. Lassila
- Department of Biomaterial Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku, Turku, Finland
| | - Paola Gandini
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Italy
| | - Maria Francesca Sfondrini
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Italy
| |
Collapse
|
3
|
Yu OY, Mei ML, Zhao IS, Lo ECM, Chu CH. Effects of Fluoride on Two Chemical Models of Enamel Demineralization. MATERIALS 2017; 10:ma10111245. [PMID: 29077034 PMCID: PMC5706192 DOI: 10.3390/ma10111245] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 10/23/2017] [Accepted: 10/26/2017] [Indexed: 11/16/2022]
Abstract
This study evaluated the effects of fluoride on subsurface enamel demineralization induced by two commonly used chemical models. Forty-eight enamel blocks were demineralized at pH = 5.0 by an acetate buffer (Group 1), a lactate buffer (Group 2), an acetate buffer with 0.02 ppm fluoride (Group 3) and a lactate buffer with 0.02 ppm fluoride (Group 4) at 25 °C for 3 weeks. The surface destruction percentage (SDP), mineral loss and lesion depth of the blocks were studied using micro-computed tomography. An elemental analysis of the enamel surface was evaluated using an energy-dispersive X-ray spectroscopy. Surface micro-hardness was determined by the Knoop Hardness Test. The mean lesion depth of Groups 1 through 4 were 134.1 ± 27.2 μm, 96.1 ± 16.5 μm, 97.5 ± 22.4 μm and 91.1 ± 16.2 μm, respectively (p < 0.001; group 1 > 2, 3 > 4). The SDPs of groups 1 through 4 were 7.8 ± 8.93%, 0.71 ± 1.6%, 0.36 ± 1.70% and 1.36 ± 2.94% (p < 0.001; group 1 > 2, 3, 4). The fluoride in mean weight percentages of groups 1 through 4 were 1.12 ± 0.24%, 1.10 ± 0.20%, 1.45 ± 0.40% and 1.51 ± 0.51%, respectively (p < 0.001; group 3, 4 > 1, 2). The mean Knoop hardness values of groups 1 through 4 were 27.5 ± 13.3, 39.7 ± 19.3, 73.6 ± 44.2 and 91.0 ± 57.2, respectively (p < 0.001; group 4 > 3 > 2 > 1). The chemical model using an acetate buffer solution created significantly deeper zones of subsurface demineralization on enamel than the lactate buffer solution. An acetate buffer may damage the enamel surface, but the surface damage can be prevented by adding fluoride.
Collapse
Affiliation(s)
- Ollie Yiru Yu
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
| | - May Lei Mei
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
| | | | | | - Chun-Hung Chu
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
| |
Collapse
|
4
|
Costa DM, Somacal DC, Borges GA, Spohr AM. Bond Capability of Universal Adhesive Systems to Dentin in Self-etch Mode after Short-term Storage and Cyclic Loading. Open Dent J 2017; 11:276-283. [PMID: 28839476 PMCID: PMC5543700 DOI: 10.2174/1874210601711010276] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Revised: 03/26/2017] [Accepted: 05/15/2017] [Indexed: 11/25/2022] Open
Abstract
Objective: The aim was to evaluate, in vitro, the tensile bond strength to dentin of Scotchbond Universal (SU), All-Bond Universal (AU) and One Coat 7 Universal (OC7) adhesives applied in self-etch mode, after 24 h of storage and after 500,000 loading cycles, using Clearfil SE Bond (SE) as a control. Materials and Methods: The adhesives were applied on the dentin of bovine teeth, followed by the application of a composite resin. Thirty specimens were obtained for each adhesive. Half of the specimens were submitted to cyclic loading for 500,000 cycles. All specimens were submitted to a tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/minute. Results: According to two-way ANOVA and Tukey’s test (α=5%), the interaction between the adhesive and cyclic loading factors was significant (p=0.001). The means followed by the same letter represent no significant difference in the bond strength (MPa) after 24 h: OC7=7.86A (±2.90), SU=6.78AB (±2.03), AU=5.61BC (±2.32), and SE=3.53C (±1.89). After cyclic loading, SE, SU and AU maintained bond strength comparable to 24 h period. There was a significant decrease only for OC7. Conclusion: SU, AU and OC7 had bond strength to dentin comparable to that of SE. Only OC7 had decreased bond strength to dentin after cyclic loading.
Collapse
Affiliation(s)
- Daniele Morosini Costa
- Department of Restorative Dentistry, School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - Deise Caren Somacal
- Department of Restorative Dentistry, School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | | | - Ana Maria Spohr
- Department of Dental Materials, School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| |
Collapse
|
5
|
Orthodontic Metallic Lingual Brackets: The Dark Side of the Moon of Bond Failures? J Funct Biomater 2017; 8:jfb8030027. [PMID: 28686194 PMCID: PMC5618278 DOI: 10.3390/jfb8030027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2017] [Revised: 07/03/2017] [Accepted: 07/06/2017] [Indexed: 11/16/2022] Open
Abstract
Lingual orthodontics, among both young and adult patients, increased in popularity during last years. The purposes of the present investigation were to evaluate the shear bond strength (SBS) values and Adhesive Remnant Index (ARI) scores of different lingual brackets compared with a vestibular control bracket. One hundred bovine teeth were extracted and embedded in resin blocks. Four different lingual brackets (Idea, Leone; STB, Ormco; TTR, RMO; 2D, Forestadent) and a vestibular control bracket (Victory, 3M) were bonded to the bovine enamel surfaces and subsequently shear tested to failure utilizing a Universal Testing Machine. SBS values were measured. A microscopic evaluation was performed to obtain ARI scores. Statistical analysis was performed at a statistically significant level of p < 0.05 to determine significant differences in SBS values and ARI Scores. No statistically significant variations in SBS were reported among the different groups. Conversely, significant differences were shown in ARI scores among the various groups. Clinical relevance of the present study is that orthodontists can expect similar resistance to debonding forces from lingual appliances as with vestibular brackets.
Collapse
|
6
|
Poggio C, Beltrami R, Colombo M, Chiesa M, Scribante A. Influence of dentin pretreatment on bond strength of universal adhesives. ACTA BIOMATERIALIA ODONTOLOGICA SCANDINAVICA 2017. [PMID: 28642929 PMCID: PMC5463333 DOI: 10.1080/23337931.2017.1305273] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Objective: The purpose of the present study was to compare bond strength of different universal adhesives under three different testing conditions: when no pretreatment was applied, after 37% phosphoric acid etching and after glycine application. Materials and methods: One hundred and fifty bovine permanent mandibular incisors were used as a substitute for human teeth. Five different universal adhesives were tested: Futurabond M+, Scotchbond Universal, Clearfil Universal Bond, G-Premio BOND, Peak Universal Bond. The adhesive systems were applied following each manufacturer's instructions. The teeth were randomly assigned to three different dentin surface pretreatments: no pretreatment agent (control), 37% phosphoric acid etching, glycine pretreatment. The specimens were placed in a universal testing machine in order to measure and compare bond strength values. Results: The Kruskal-Wallis analysis of variance and the Mann-Whitney test were applied to assess significant differences among the groups. Dentin pretreatments provided different bond strength values for the adhesives tested, while similar values were registered in groups without dentin pretreatment. Conclusions: In the present report, dentin surface pretreatment did not provide significant differences in shear bond strength values of almost all groups. Acid pretreatment lowered bond strength values of Futurabond and Peak Universal Adhesives, whereas glycine pretreatment increased bond strength values of G Praemio Bond adhesive system.
Collapse
Affiliation(s)
- Claudio Poggio
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Riccardo Beltrami
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Marco Colombo
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Marco Chiesa
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Andrea Scribante
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| |
Collapse
|
7
|
Effects of enamel sealing on shear bond strength and the adhesive remnant index : Study of three fluoride-releasing adhesives in combination with metal and ceramic brackets. J Orofac Orthop 2016; 78:1-10. [PMID: 27896419 DOI: 10.1007/s00056-016-0065-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Accepted: 06/27/2016] [Indexed: 10/20/2022]
Abstract
OBJECTIVES Selected combinations of materials were used to create tooth-adhesive-bracket complexes to evaluate shear bond strength (SBS) and the adhesive remnant index (ARI) with regard to enamel sealing. METHODS Four adhesive systems also appropriate for use as enamel sealants were combined with four bracket types, resulting in 16 adhesive-bracket combinations, each of which was tested on 15 permanent bovine incisors. Sealant-adhesives included two recently introduced fluoride-releasing systems (Riva bond LC® and go!®), one established primer (Opal® Seal™), and one commonly used adhesive as control (Transbond™ XT). Brackets included two metal (discovery® by Dentaurum and Sprint®) and two ceramic (discovery® pearl and GLAM®) systems. After embedding the bovine teeth, bonding the brackets to their surface, and storing the resultant samples as per DIN 13990-2 with modifications, an SBS test was performed by applying the shear force directly at the bracket base in an incisocervical direction. Then the ARI scores were determined. RESULTS Discovery® + Transbond™ XT yielded the highest (47.2 MPa) and GLAM® + go!® the lowest (17.0 MPa) mean SBS values. Significant differences (p < 0.0001) were found between metal and ceramic brackets of the same manufacturers (Dentaurum and Forestadent). Our ratings of the failure modes upon debonding predominantly yielded ARI 0 or 1. The high SBS values and low ARI scores observed with discovery® + Transbond XT™ were reflected in a high rate of enamel fracture, which occurred on 11 of the 15 tooth specimens in this group. CONCLUSIONS All sealant-bracket combinations were found to yield levels of SBS adequate for clinical application. SBS values and ARI scores varied significantly depending on which sealant-brackets were used.
Collapse
|
8
|
Scribante A, Sfondrini MF, Fraticelli D, Daina P, Tamagnone A, Gandini P. The influence of no-primer adhesives and anchor pylons bracket bases on shear bond strength of orthodontic brackets. BIOMED RESEARCH INTERNATIONAL 2013; 2013:315023. [PMID: 23984339 PMCID: PMC3747346 DOI: 10.1155/2013/315023] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Accepted: 07/09/2013] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The aim of this study was to compare the shear bond strength (SBS) and adhesive remnant index (ARI) scores of no-primer adhesives tested with two different bracket bases. MATERIALS AND METHODS 120 bovine permanent mandibular incisors were divided into 6 groups of 20 specimens. Two brackets (ODP) with different bracket bases (anchor pylons and 80-gauge mesh) were bonded to the teeth using a conventional adhesive (Transbond XT) and two different no-primer adhesive (Ortho Cem; Heliosit) systems. Groups were tested using an instron universal testing machine. SBS values were recorded. ARI scores were measured. SEM microphotographs were taken to evaluate the pattern of bracket bases. Statistical analysis was performed. ANOVA and Tukey tests were carried out for SBS values, whereas a chi-squared test was applied for ARI scores. RESULTS Highest bond strength values were reported with Transbond XT (with both pad designs), Ortho Cem bonded on anchor pylons and Heliosit on 80-gauge mesh. A higher frequency of ARI score of "3" was reported for Transbond XT groups. Other groups showed a higher frequency of ARI score "2" and "1." CONCLUSION Transbond XT showed the highest shear bond strength values with both pad designs.
Collapse
Affiliation(s)
- Andrea Scribante
- Dipartimento di Scienze Clinico Chirurgiche, Diagnostiche e Pediatriche, Unità di Odontoiatria, Reparto di Ortognatodonzia, Università degli Studi di Pavia, Piazzale Golgi, 2-27100 Pavia, Italy.
| | | | | | | | | | | |
Collapse
|
9
|
Sfondrini MF, Fraticelli D, Gandini P, Scribante A. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination. BIOMED RESEARCH INTERNATIONAL 2013; 2013:180137. [PMID: 23762825 PMCID: PMC3671238 DOI: 10.1155/2013/180137] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2013] [Accepted: 04/24/2013] [Indexed: 11/18/2022]
Abstract
PURPOSE The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. MATERIALS AND METHODS 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). RESULTS Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. CONCLUSIONS Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.
Collapse
Affiliation(s)
- Maria Francesca Sfondrini
- Università degli Studi di Pavia, Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, Sezione di Odontoiatria, Reparto di Ortognatodonzia, Piazzale Golgi 2, 27100 Pavia, Italy
| | - Danilo Fraticelli
- Università degli Studi di Pavia, Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, Sezione di Odontoiatria, Reparto di Ortognatodonzia, Piazzale Golgi 2, 27100 Pavia, Italy
| | - Paola Gandini
- Università degli Studi di Pavia, Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, Sezione di Odontoiatria, Reparto di Ortognatodonzia, Piazzale Golgi 2, 27100 Pavia, Italy
| | - Andrea Scribante
- Università degli Studi di Pavia, Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, Sezione di Odontoiatria, Reparto di Ortognatodonzia, Piazzale Golgi 2, 27100 Pavia, Italy
| |
Collapse
|
10
|
Scribante A, Sfondrini MF, Gatti S, Gandini P. Disinclusion of unerupted teeth by mean of self-ligating brackets: effect of blood contamination on shear bond strength. Med Oral Patol Oral Cir Bucal 2013; 18:e162-e167. [PMID: 23229253 PMCID: PMC3548638 DOI: 10.4317/medoral.18246] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2012] [Accepted: 06/07/2012] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES The aim of this study was to assess the effect of blood contamination on the shear bond strength and failure site of three different orthodontic self-ligating brackets. STUDY DESIGN 240 bovine permanent mandibular incisors were randomly divided into 12 groups of 20 specimens each. Orthodontic self-ligating brackets were tested under four different enamel surface conditions: a) dry, b) blood contamination before priming, c) blood contamination after priming, d) blood contamination before and after priming. Brackets were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values), and Chi squared test (ARI Scores). RESULTS Non-contaminated enamel surfaces showed highest bond strengths for all self ligating brackets. Under blood-contamination shear bond strengths lowered for all brackets tested. Groups contaminated before and after primer application showed the lowest shear bond strength. Significant differences in debond locations were found among the groups under the various enamel surface conditions. CONCLUSIONS Blood contamination of enamel during the bonding procedure lowers bond strength values of self ligating brackets, expecially when contamination occur in different times of the bonding procedure.
Collapse
Affiliation(s)
- Andrea Scribante
- Department of Orthodontics and Department of Surgical Sciences (Head: Prof. Paolo Dionigi), University of Pavia, Pavia, Italy.
| | | | | | | |
Collapse
|