1
|
Han T, Duan Q, Yang R, Wang Y, Yin H, Meng F, Liu Y, Qian T. Monitoring the therapeutic efficacy of CA4P in the rabbit VX2 liver tumor using dynamic contrast-enhanced MRI. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY (ANKARA, TURKEY) 2021; 27:587-594. [PMID: 34559047 DOI: 10.5152/dir.2021.20010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE The present work aims to evaluate whether dynamic contrast-enhanced magnetic resonance Imaging (DCE-MRI) can monitor non-invasively the blocking effect on microvessels of the Combretastatin-A4-phosphate (CA4P) and assess the therapeutic efficacy. METHODS Forty rabbits were implanted the VX2 tumors specimens. Two weeks later, serial MRI (T1 weighted image, T2 weighted image and DCE) were performed at 0 h, 4 h, 24 h, 3 d and 7 d after CA4P (10 mg/kg) or saline treatment. The parameters of DCE (Ktrans, Kep, Ve and iAUC60) of enhancement tumor portions were measured. Then all the tumor samples were stained to count microvessel density (MVD). At last, two-way repeated measures ANOVA was used to analyze the difference between and within groups. The correlation between the Ktrans, Kep, Ve, iAUC60 and MVD was analyzed by using the Pearson correlation analysis and Spearman's rank correlation. RESULTS The Ktrans and iAUC60 in the CA4P group were lower than the values of the control group at 4 h after treatment, which have significant differences (D-value: -0.133 min-1, 95%CI: -0.169~-0.097 min-1,F = 59.109, p < 0.001 for Ktrans; D-value: -10.533 mmol/sec, 95%CI: -17.147~-3.919 mmol/sec,F = 11.110, and p = 0.003 for iAUC60). In the CA4P group, the Ktrans and iAUC60 reached the minimum values at 4 h. There were significant differences between 4 h and other different time points of the Ktrans and iAUC60 in the treatment group (all p < 0.01). The parameters Ktrans (r = 0.532, P = 0.016 and r = 0.681, P = 0.001, respectively) and iAUC60 (r = 0.580, P = 0.007 and r = 0.568, P = 0.009, respectively) of 7 days showed correlation with MVD in both groups, while Kep and Ve did not show correlation with MVD (P > 0.05). CONCLUSION The blocking effect of microvessels after CA4P treatment can be evaluated by DCE-MRI, and the parameters of quantitative Ktrans and semi- quantitative iAUC60 can assess the change of the tumor angiogenesis noninvasively.
Collapse
Affiliation(s)
| | - Qingqing Duan
- Department of Radiology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Rong Yang
- Department of Radiology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Yuzhe Wang
- Department of Radiology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Huabin Yin
- Department of Radiology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Fanhua Meng
- Department of Radiology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Yongjuan Liu
- Department of Pathology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Ting Qian
- Department of Radiology, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| |
Collapse
|
2
|
Meng F, Zou B, Yang R, Duan Q, Qian T. The diagnostic efficiency of the perfusion-related parameters in assessing the vascular disrupting agent (CA4P) response in a rabbit VX2 liver tumor model. Acta Radiol 2021; 63:1147-1156. [PMID: 34279135 DOI: 10.1177/02841851211032450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND There are inconsistencies when concomitantly using dynamic contrast enhancement (DCE) and intravoxel incoherent motion (IVIM) to evaluate diagnostic efficiency. PURPOSE To evaluate the diagnostic efficiency of perfusion-related parameters in assessing the effect of Combretastatin-A4-phosphate (CA4P) in a rabbit VX2 liver tumor model using DCE and IVIM. MATERIAL AND METHODS Twenty rabbits implanted with VX2 tumors were included in the study. The perfusion-parameters of DCE (Ktrans and iAUC60) and IVIM (f and D*) were measured at baseline and 4 h after administration of CA4P. Subsequently, the rabbits were euthanized. Pre- and post-treatment perfusion parameters were analyzed using paired t-test. Correlation between the various perfusion parameters and correlation of perfusion parameters with microvascular density (MVD) were assessed using Pearson correlation analysis. The diagnostic efficiency was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS All perfusion parameters (Ktrans, iAUC60, f and D*) showed significant decrease after 4 h of CA4P administration (all P < 0.001). Post-treatment perfusion parameters showed a moderate correlation with MVD (r = 0.663, r = 0.567, r = 0.685, r = 0.618, respectively; all P < 0.05). At baseline and after treatment, Ktrans values and iAUC60 showed correlation with f and D* (all P < 0.05). Concomitant use of perfusion parameters of DCE and IVIM showed the best diagnostic performance, which was slightly greater than that observed with individual application of DCE or IVIM (AUC = 0.915, 0.880, and 0.895, respectively). CONCLUSION Although concomitant application of DCE and IVIM can slightly improve the diagnostic value in assessing the effect of CA4P, the values were relatively small.
Collapse
Affiliation(s)
- Fanhua Meng
- Department of Radiology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, PR China
| | - Biao Zou
- Department of Radiology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, PR China
| | - Rong Yang
- Department of Radiology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, PR China
| | - Qingqing Duan
- Department of Radiology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, PR China
| | - Ting Qian
- Department of Radiology, International Peace Maternity and Child Health Hospital, International Peace Maternity and Child Health Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| |
Collapse
|
3
|
Chemoembolization with Vascular Disrupting Agent CKD-516 Dissolved in Ethiodized Oil in Combination with Doxorubicin: A VX2 Tumor Model Study. J Vasc Interv Radiol 2018; 29:1078-1084. [DOI: 10.1016/j.jvir.2018.03.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Revised: 02/25/2018] [Accepted: 03/16/2018] [Indexed: 12/16/2022] Open
|
4
|
Yan Y, Sun X, Shen B. Contrast agents in dynamic contrast-enhanced magnetic resonance imaging. Oncotarget 2018; 8:43491-43505. [PMID: 28415647 PMCID: PMC5522164 DOI: 10.18632/oncotarget.16482] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2017] [Accepted: 03/15/2017] [Indexed: 12/19/2022] Open
Abstract
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a noninvasive method to assess angiogenesis, which is widely used in clinical applications including diagnosis, monitoring therapy response and prognosis estimation in cancer patients. Contrast agents play a crucial role in DCE-MRI and should be carefully selected in order to improve accuracy in DCE-MRI examination. Over the past decades, there was much progress in the development of optimal contrast agents in DCE-MRI. In this review, we describe the recent research advances in this field and discuss properties of contrast agents, as well as their advantages and disadvantages. Finally, we discuss the research perspectives for improving this promising imaging method.
Collapse
Affiliation(s)
- Yuling Yan
- Molecular Imaging Research Center (MIRC), Harbin Medical University, Harbin, Heilongjiang, China.,TOF-PET/CT/MR Center, The Fourth Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| | - Xilin Sun
- Molecular Imaging Research Center (MIRC), Harbin Medical University, Harbin, Heilongjiang, China.,TOF-PET/CT/MR Center, The Fourth Hospital of Harbin Medical University, Harbin, Heilongjiang, China.,Molecular Imaging Program at Stanford (MIPS), Department of Radiology, Stanford University School of Medicine, Stanford, California, USA
| | - Baozhong Shen
- Molecular Imaging Research Center (MIRC), Harbin Medical University, Harbin, Heilongjiang, China.,TOF-PET/CT/MR Center, The Fourth Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| |
Collapse
|
5
|
Park JE, Han K, Sung YS, Chung MS, Koo HJ, Yoon HM, Choi YJ, Lee SS, Kim KW, Shin Y, An S, Cho HM, Park SH. Selection and Reporting of Statistical Methods to Assess Reliability of a Diagnostic Test: Conformity to Recommended Methods in a Peer-Reviewed Journal. Korean J Radiol 2017; 18:888-897. [PMID: 29089821 PMCID: PMC5639154 DOI: 10.3348/kjr.2017.18.6.888] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Accepted: 07/28/2017] [Indexed: 12/13/2022] Open
Abstract
Objective To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. Materials and Methods Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. Results Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. Conclusion Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary.
Collapse
Affiliation(s)
- Ji Eun Park
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Yu Sub Sung
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Mi Sun Chung
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Korea
| | - Hyun Jung Koo
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Hee Mang Yoon
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Young Jun Choi
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Seung Soo Lee
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Kyung Won Kim
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Youngbin Shin
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Suah An
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| | - Hyo-Min Cho
- Korea Research Institute of Standards and Science, Daejeon 34113, Korea
| | - Seong Ho Park
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| |
Collapse
|
6
|
Zhu J, Zhang F, Zhou J, Li H. Assessment of therapeutic response in Crohn's disease using quantitative dynamic contrast enhanced MRI (DCE-MRI) parameters: A preliminary study. Medicine (Baltimore) 2017; 96:e7759. [PMID: 28796069 PMCID: PMC5556235 DOI: 10.1097/md.0000000000007759] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The aim of the study was to investigate dynamic contrast enhanced MRI (DCE-MRI) as a potential marker to assess the therapeutic responses of fecal microbiota transplantation (FMT) in patients with Crohn's disease (CD) and to determine the parameter or combination of parameters most strongly associated with changes in clinical indicators after treatment.In 22 CD patients, DCE-MRI was performed with a 3.0T scanner. Parameters of DCE-MRI (vascular transfer constant [K] and blood volume [BV]) in the terminal ileum were compared between before and day 90 after FMT treatment. The differences of clinical indicators (C-reactive protein [CRP], Harvey-Bradshaw index [HBI]) and DCE-MRI parameters (K, BV) between pre- and post-treatment was calculated by Student's 2-tailed, paired t-test. The correlations between percent change of clinical indicators (ΔCRP, ΔHBI) with DCE-MRI parameters (ΔK, ΔBV) were analyzed by Pearson's correlation coefficients. A logistic regression model was used to identify the changes of DCE-MRI parameters related to the treatment outcomes. Receiver operating characteristic curves (ROCs) were generated to assess which DCE-MRI parameter showed the best accuracy for evaluation of therapeutic response.After treatment, mean values of clinical indicators decreased significantly (CRP: 62.68 ± 31.86 vs 43.55 ± 29.63 mg/L, P = .008; HBI: 7.18 ± 2.10 vs 5.73 ± 2.33, P = 0.012). Both DCE-MRI parameters showed prominent differences before and after treatment: K (1.86 ± 0.87 vs 1.39 ± 0.83 min, P = .017), BV (61.02 ± 28.49 vs 41.96 ± 22.75 mL/100 g, P = .005). There were significant correlations between ΔCRP or ΔHBI and percent change of CDE-MRI parameters (ΔK to ΔCRP: 0.659; ΔK to ΔHBI: 0.496; ΔBV to ΔCRP: 0.442; ΔBV to ΔHBI: 0.476). Compared to ΔK and ΔBV individually, the combination of both parameters performed best in assessment of therapeutic response with an area under the ROCs (AUC) of 0.948.K and BV parameters derived from DCE-MRI have the potential to assess for therapeutic response after FMT treatment for CD. The combination of K and BV measurements improved the predictive capability compared to the individual parameters.
Collapse
Affiliation(s)
| | - Faming Zhang
- Center of Intestinal Diseases, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | | | | |
Collapse
|