1
|
Sharma A, Song R, Sarmey N, Harasimchuk S, Bulacio J, Pucci F, Rammo R, Bingaman W, Serletis D. Validation and Safety Profile of a Novel, Noninvasive Fiducial Attachment for Stereotactic Robotic-Guided Stereoelectroencephalography: A Case Series. Oper Neurosurg (Hagerstown) 2024:01787389-990000000-01137. [PMID: 38651866 DOI: 10.1227/ons.0000000000001148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Accepted: 02/06/2024] [Indexed: 04/25/2024] Open
Abstract
BACKGROUND AND OBJECTIVES We developed, tested, and validated a novel, noninvasive, Leksell G frame-based fiducial attachment, for use in stereotactic registration for stereoelectroencephalography (sEEG). Use of the device increased the number of fixed reference points available for registration, while obviating the need for additional scalp incisions. We report here on our experience and safety profile of using the device. METHODS We collected registration data using the fiducial device across 25 adult and pediatric patients with epilepsy consecutively undergoing robotic-guided sEEG for invasive epilepsy monitoring, treated between May 2022 and July 2023. ROSA One Brain was used for trajectory planning and electrode implantation. Postoperative clinical and radiographic data were computed and quantified, including mean registration error for all patients. Entry point, target point (TP), and angular errors were measured. Descriptive statistics and correlation coefficients for error were calculated. RESULTS Twenty-five patients underwent robotic-guided sEEG implantation (11 patients, bilateral; 10 patients, left unilateral; 4 patients, right). The mean number of electrodes per patient was 18 ± 3. The average mean registration error was 0.77 ± 0.11 mm. All patients were implanted with Ad-Tech depth electrodes. No clinically relevant complications were reported. Analysis of trajectory error was performed on 446 electrodes. The median entry point error was 1.03 mm (IQR 0.69-1.54). The median TP error was 2.26 mm (IQR 1.63-2.93). The mean angular error was 0.03 radians (IQR 0.02-0.05). There was no significant correlation between root mean square error and lead error. Root mean square error did not appreciably change over time, nor were there any significant changes in average angular, entry point, or TP error metrics. CONCLUSION A novel, noninvasive, Leksell G frame-based fiducial attachment was developed, tested, and validated, facilitating O-arm-based stereotactic registration for sEEG. This simple innovation maintained an excellent accuracy and safety profile for sEEG procedures in epilepsy patients, with the added advantages of providing additional reference points for stereotactic registration, without requiring additional scalp incisions.
Collapse
Affiliation(s)
- Akshay Sharma
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Ryan Song
- Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Nehaw Sarmey
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Stephen Harasimchuk
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Juan Bulacio
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Francesco Pucci
- Department of Neurosurgery, University of Illinois, Chicago, Chicago, Illinois, USA
| | - Richard Rammo
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - William Bingaman
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Demitre Serletis
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
2
|
Du C, Wang L, Yan J, Li G, Wu Y, Zhao G, Cui D, Jin W, Yin S. The Association Between Trajectory-Skull Angle and Accuracy of Stereoelectroencephalography Electrode Implantation in Drug-Resistant Epilepsy. World Neurosurg 2024; 184:e408-e416. [PMID: 38309654 DOI: 10.1016/j.wneu.2024.01.139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 01/24/2024] [Indexed: 02/05/2024]
Abstract
OBJECTIVE To analyze the relationship between trajectory-skull angle and stereoelectroencephalography electrode implantation accuracy in drug-resistant epilepsy patients, aiming to guide clinical electrode placement and enhance surgical precision and safety. METHODS We conducted a retrospective analysis of medical records and surgical characteristics of 32 consecutive patients diagnosed with drug-resistant epilepsy, who underwent stereoelectroencephalography procedures at our center from June 2020 to June 2023. To evaluate the accuracy of electrode implantation, we utilized preoperative and postoperative computed tomography scans fused with SinoPlan software-planned trajectories. Entry radial error and target vector error were assessed as measurements of electrode implantation accuracy. RESULTS After adjusting for confounders, we found a significant positive correlation between trajectory-skull angle and entry radial error (β = 0.02, 95% CI: 0.01-0.03, P < 0.001). Likewise, a significant positive correlation existed between trajectory-skull angle and target vector error in all three models (β = 0.03, 95% CI: 0.01-0.04, P < 0.001). Additionally, a U-shaped relationship between trajectory-skull angle and target vector error was identified using smooth curve fitting. This U-shaped pattern persisted in both frame-based and robot-guided stereotactic techniques. According to the two-piecewise linear regression model, the inflection points were 9° in the frame-based group and 16° in the robot-guided group. CONCLUSIONS This study establishes a significant positive linear correlation between trajectory-skull angle and entry radial error, along with a distinctive U-shaped pattern in the relationship between trajectory-skull angle and target vector error. Our findings suggest that trajectory-skull angles of 9° (frame-based) and 16° (robot-guided) may optimize the accuracy of target vector error.
Collapse
Affiliation(s)
- Chuan Du
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China; Department of Neurosurgery, Affiliated Hospital of Chengdu University, Chengdu, China
| | - Le Wang
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China
| | - Jingtao Yan
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Guangfeng Li
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Yuzhang Wu
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Guangrui Zhao
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Deqiu Cui
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China
| | - Weipeng Jin
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China
| | - Shaoya Yin
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China.
| |
Collapse
|
3
|
Skrehot HC, Englot DJ, Haneef Z. Neuro-stimulation in focal epilepsy: A systematic review and meta-analysis. Epilepsy Behav 2023; 142:109182. [PMID: 36972642 DOI: 10.1016/j.yebeh.2023.109182] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 03/10/2023] [Accepted: 03/12/2023] [Indexed: 03/29/2023]
Abstract
OBJECTIVES Different neurostimulation modalities are available to treat drug-resistant focal epilepsy when surgery is not an option including vagus nerve stimulation (VNS), responsive neurostimulation (RNS), and deep brain stimulation (DBS). Head-to-head comparisons of efficacy do not exist between them nor are likely to be available in the future. We performed a meta-analysis on VNS, RNS, and DBS outcomes to compare seizure reduction efficacy for focal epilepsy. METHODS We systematically reviewed the literature for reported seizure outcomes following implantation with VNS, RNS, and DBS in focal-onset seizures and performed a meta-analysis. Prospective or retrospective clinical studies were included. RESULTS Sufficient data were available at years one (n = 642, two (n = 480), and three (n = 385) for comparing the three modalities with each other. Seizure reduction for the devices at years one, two, and three respectively were: RNS: 66.3%, 56.0%, 68.4%; DBS- 58.4%, 57.5%, 63.8%; VNS 32.9%, 44.4%, 53.5%. Seizure reduction at year one was greater for RNS (p < 0.01) and DBS (p < 0.01) compared to VNS. CONCLUSIONS Our findings indicate the seizure reduction efficacy of RNS is similar to DBS, and both had greater seizure reductions compared to VNS in the first-year post-implantation, with the differences diminishing with longer-term follow-up. SIGNIFICANCE The results help guide neuromodulation treatment in eligible patients with drug-resistant focal epilepsy.
Collapse
Affiliation(s)
- Henry C Skrehot
- Department of Neurology, Baylor College of Medicine, Houston, TX 77030, USA
| | - Dario J Englot
- Departments of Neurological Surgery, Neurology, Radiology, Electrical Engineering, and Biomedical Engineering, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Zulfi Haneef
- Department of Neurology, Baylor College of Medicine, Houston, TX 77030, USA; Neurology Care Line, VA Medical Center, Houston, TX 77030, USA.
| |
Collapse
|
4
|
Gadot R, Vanegas Arroyave N, Dang H, Anand A, Najera RA, Taneff LY, Bellows S, Tarakad A, Jankovic J, Horn A, Shofty B, Viswanathan A, Sheth SA. Association of clinical outcomes and connectivity in awake versus asleep deep brain stimulation for Parkinson disease. J Neurosurg 2022; 138:1016-1027. [PMID: 35932263 DOI: 10.3171/2022.6.jns212904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 06/09/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Deep brain stimulation (DBS) for Parkinson disease (PD) is traditionally performed with awake intraoperative testing and/or microelectrode recording. Recently, however, the procedure has been increasingly performed under general anesthesia with image-based verification. The authors sought to compare structural and functional networks engaged by awake and asleep PD-DBS of the subthalamic nucleus (STN) and correlate them with clinical outcomes. METHODS Levodopa equivalent daily dose (LEDD), pre- and postoperative motor scores on the Movement Disorders Society-Unified Parkinson's Disease Rating Scale part III (MDS-UPDRS III), and total electrical energy delivered (TEED) at 6 months were retroactively assessed in patients with PD who received implants of bilateral DBS leads. In subset analysis, implanted electrodes were reconstructed using the Lead-DBS toolbox. Volumes of tissue activated (VTAs) were used as seed points in group volumetric and connectivity analysis. RESULTS The clinical courses of 122 patients (52 asleep, 70 awake) were reviewed. Operating room and procedure times were significantly shorter in asleep cases. LEDD reduction, MDS-UPDRS III score improvement, and TEED at the 6-month follow-up did not differ between groups. In subset analysis (n = 40), proximity of active contact, VTA overlap, and desired network fiber counts with motor STN correlated with lower DBS energy requirement and improved motor scores. Discriminative structural fiber tracts involving supplementary motor area, thalamus, and brainstem were associated with optimal clinical improvement. Areas of highest structural and functional connectivity with VTAs did not significantly differ between the two groups. CONCLUSIONS Compared to awake STN DBS, asleep procedures can achieve similarly optimal targeting-based on clinical outcomes, electrode placement, and connectivity estimates-in more efficient procedures and shorter operating room times.
Collapse
Affiliation(s)
- Ron Gadot
- 1Department of Neurosurgery, Baylor College of Medicine
| | - Nora Vanegas Arroyave
- 2Parkinson's Disease Center and Movement Disorders Clinic, Department of Neurology, Baylor College of Medicine, Houston, Texas; and
| | - Huy Dang
- 1Department of Neurosurgery, Baylor College of Medicine
| | - Adrish Anand
- 1Department of Neurosurgery, Baylor College of Medicine
| | | | - Lisa Yutong Taneff
- 2Parkinson's Disease Center and Movement Disorders Clinic, Department of Neurology, Baylor College of Medicine, Houston, Texas; and
| | - Steven Bellows
- 2Parkinson's Disease Center and Movement Disorders Clinic, Department of Neurology, Baylor College of Medicine, Houston, Texas; and
| | - Arjun Tarakad
- 2Parkinson's Disease Center and Movement Disorders Clinic, Department of Neurology, Baylor College of Medicine, Houston, Texas; and
| | - Joseph Jankovic
- 2Parkinson's Disease Center and Movement Disorders Clinic, Department of Neurology, Baylor College of Medicine, Houston, Texas; and
| | - Andreas Horn
- 3Department of Neurology, Movement Disorder and Neuromodulation Unit, Charité-Universitätsmedizin, Berlin, Germany
| | - Ben Shofty
- 1Department of Neurosurgery, Baylor College of Medicine
| | | | | |
Collapse
|
5
|
Anand A, Gavvala JR, Mathura R, Najera RA, Gadot R, Shofty B, Sheth SA. Elimination of anxiety after laser interstitial thermal ablation of the dominant cingulate gyrus for epilepsy. Surg Neurol Int 2022; 13:178. [PMID: 35509526 PMCID: PMC9062951 DOI: 10.25259/sni_241_2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 03/16/2022] [Indexed: 11/22/2022] Open
Abstract
Background: Anxiety is a common symptom of mental health disorders. Surgical treatment of anxiety-related disorders is limited by our understanding of the neural circuitry responsible for emotional regulation. Limbic regions communicate with other cortical and subcortical regions to generate emotional responses and behaviors toward anxiogenic stimuli. Epilepsy involving corticolimbic regions may disrupt normal neural circuitry and present with mood disorders. Anxiety presenting in patients with mesial temporal lobe epilepsy is common; however, anxiety in patients with cingulate epilepsy is not well described. Neurosurgical cases with rare clinical presentations may provide insight into the basic functionality of the human mind and ultimately lead to improvements in surgical treatments. Case Description: We present the case of a 24-year-old male with a 20-year history of nonlesional and cingulate epilepsy with an aura of anxiety and baseline anxiety. Noninvasive work-up was discordant. Intracranial evaluation using stereoelectroencephalography established the epileptogenic zone in the left anterior and mid-cingulate gyrus. Stimulation of the cingulate reproduced a sense of anxiety typical of the habitual auras. We performed laser interstitial thermal therapy of the left anterior and mid-cingulate gyrus. At 8 months following ablation, the patient reported a substantial reduction in seizure frequency and complete elimination of his baseline anxiety and anxious auras. Conclusion: This case highlights the role of the cingulate cortex (CC) in regulating anxiety. Ablation of the epileptic focus resolved both epilepsy-related anxiety and baseline features.a Future studies assessing the role of the CC in anxiety disorders may enable improvements in surgical treatments for anxiety disorders.
Collapse
Affiliation(s)
- Adrish Anand
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, United States,
| | - Jay R. Gavvala
- Department of Neurology, Baylor College of Medicine, Houston, Texas, United States
| | - Raissa Mathura
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, United States,
| | - Ricardo A. Najera
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, United States,
| | - Ron Gadot
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, United States,
| | - Ben Shofty
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, United States,
| | - Sameer A. Sheth
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, United States,
| |
Collapse
|
6
|
Gadot R, Shofty B, Najera RA, Anand A, Banks G, Khan AB, LoPresti MA, Vanegas Arroyave N, Sheth SA. Case Report: Dual Target Deep Brain Stimulation With Externalized Programming for Post-traumatic Complex Movement Disorder. Front Neurosci 2021; 15:774073. [PMID: 34819837 PMCID: PMC8606815 DOI: 10.3389/fnins.2021.774073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 10/18/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction: Movement disorders can be common, persistent, and debilitating sequelae of severe traumatic brain injury. Post-traumatic movement disorders are usually complex in nature, involving multiple phenomenological manifestations, and can be difficult to control with medical management alone. Deep brain stimulation (DBS) has been used to treat these challenging cases, but distorted brain anatomy secondary to trauma can complicate effective targeting. In such cases, use of diffusion tractography imaging and inpatient testing with externalized DBS leads can be beneficial in optimizing outcomes. Case Description: We present the case of a 42-year-old man with severe, disabling post-traumatic tremor who underwent bilateral, dual target DBS to the globus pallidus internus (GPi) and a combined ventral intermediate nucleus of the thalamus (Vim)/dentato-rubro-thalamic tracts (DRTT) target. DRTT fiber tracts were reconstructed preoperatively to assist in surgical targeting given the patient’s distorted anatomy. Externalization and survey of the four leads extra-operatively with inpatient testing allowed for internalization of the leads that demonstrated benefit. Six months after surgery, the patient’s tremor and dystonic burden had decreased by 67% in the performance sub-score of The Essential Tremor Rating Scale (TETRAS). Conclusion: A patient-tailored approach including target selection guided by individualized anatomy and tractography as well as extra-operative externalized lead interrogation was shown to be effective in optimizing clinical outcome in a patient with refractory post-traumatic tremor.
Collapse
Affiliation(s)
- Ron Gadot
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| | - Ben Shofty
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| | - Ricardo A Najera
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| | - Adrish Anand
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| | - Garrett Banks
- Department of Neurological Surgery, Columbia University Medical Center, New York, NY, United States
| | - Abdul Basit Khan
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| | - Melissa A LoPresti
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| | | | - Sameer A Sheth
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States
| |
Collapse
|
7
|
Guglielmi G, Eschbach KL, Alexander AL. Smaller Knife, Fewer Seizures? Recent Advances in Minimally Invasive Techniques in Pediatric Epilepsy Surgery. Semin Pediatr Neurol 2021; 39:100913. [PMID: 34620456 DOI: 10.1016/j.spen.2021.100913] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/09/2021] [Accepted: 08/11/2021] [Indexed: 02/02/2023]
Abstract
Children with drug-resistant epilepsy are at high risk for developmental delay, increased mortality, psychiatric comorbidities, and requiring assistance with activities of daily living. Despite the advent of new and effective pharmacologic therapies, about one in 5 children will develop drug-resistant epilepsy, and most of these children continue to have seizures despite trials of other medication. Epilepsy surgery is often a safe and effective option which may offer seizure freedom or at least a significant reduction in seizure burden in many children. However, despite published evidence of safety and efficacy, epilepsy surgery remains underutilized in the pediatric population. Patient and family fears about the risks of surgery may contribute to this gap. Less invasive surgical techniques may be more palatable to children with epilepsy and their caregivers. In this review, we present recent advances in minimally invasive techniques for the surgical treatment of epilepsy as well as intriguing possibilities for the future. We describe the indications for, benefits of, and limits to minimally-invasive techniques including Stereo-encephalography, laser interstitial thermal ablation, deep brain stimulation, focused ultrasound, stereo-encephalography-guided radiofrequency ablation, endoscopic disconnections, and responsive neurostimulation.
Collapse
Affiliation(s)
- Gina Guglielmi
- Graduate Medical Education, Neurological Surgery Residency, Carle BroMenn Medical Center, Normal IL; Section of Pediatric Neurology, Children's Hospital Colorado, Aurora CO; Department of Pediatrics, University of Colorado Anschutz School of Medicine, Aurora CO; Division of Pediatric Neurosurgery, Children's Hospital Colorado, Aurora CO; Department of Neurosurgery, University of Colorado Anschutz School of Medicine, Aurora CO
| | - Krista L Eschbach
- Graduate Medical Education, Neurological Surgery Residency, Carle BroMenn Medical Center, Normal IL; Section of Pediatric Neurology, Children's Hospital Colorado, Aurora CO; Department of Pediatrics, University of Colorado Anschutz School of Medicine, Aurora CO; Division of Pediatric Neurosurgery, Children's Hospital Colorado, Aurora CO; Department of Neurosurgery, University of Colorado Anschutz School of Medicine, Aurora CO
| | - Allyson L Alexander
- Graduate Medical Education, Neurological Surgery Residency, Carle BroMenn Medical Center, Normal IL; Section of Pediatric Neurology, Children's Hospital Colorado, Aurora CO; Department of Pediatrics, University of Colorado Anschutz School of Medicine, Aurora CO; Division of Pediatric Neurosurgery, Children's Hospital Colorado, Aurora CO; Department of Neurosurgery, University of Colorado Anschutz School of Medicine, Aurora CO.
| |
Collapse
|