Panaino CM, Mackay RI, Sotiropoulos M, Kirkby KJ, Taylor MJ. Full 3D position reconstruction of a radioactive source based on a novel hyperbolic geometrical algorithm.
COMPUTER PHYSICS COMMUNICATIONS 2020;
252:107131. [PMID:
32624585 PMCID:
PMC7233137 DOI:
10.1016/j.cpc.2019.107131]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 12/02/2019] [Accepted: 12/16/2019] [Indexed: 06/11/2023]
Abstract
A new method to locate, with millimetre uncertainty, in 3D, a γ -ray source emitting multiple γ -rays in a cascade, employing conventional LaBr3(Ce) scintillation detectors, has been developed. Using 16 detectors in a symmetrical configuration the detector energy and time signals, resulting from the γ -ray interactions, are fed into a new source position reconstruction algorithm. The Monte-Carlo based Geant4 framework has been used to simulate the detector array and a 60Co source located at two positions within the spectrometer central volume. For a source located at (0,0,0) the algorithm reports X, Y, Z values of -0.3 ± 2.5, -0.4 ± 2.4, and -0.6 ± 2.5 mm, respectively. For a source located at (20,20,20) mm, with respect to the array centre, the algorithm reports X, Y, Z values of 20.2 ± 1.0, 20.2 ± 0.9, and 20.1 ± 1.2 mm. The resulting precision of the reconstruction means that this technique could find application in a number of areas including nuclear medicine, national security, radioactive waste assay and proton beam therapy.