1
|
Bitencourt AGV, Thakur SB. Editorial for "Discrimination Between Benign and Malignant Lesions With Restriction Spectrum Imaging MRI in a Breast Cancer Screening Cohort". J Magn Reson Imaging 2024. [PMID: 39295109 DOI: 10.1002/jmri.29600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 06/14/2024] [Indexed: 09/21/2024] Open
Affiliation(s)
- Almir G V Bitencourt
- Imaging Department, A.C.Camargo Cancer Center, São Paulo, Brazil
- Alta Excelência Diagnóstica, DASA, São Paulo, Brazil
| | - Sunitha B Thakur
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
2
|
He L, Qin Y, Hu Q, Liu Z, Zhang Y, Ai T. Quantitative characterization of breast lesions and normal fibroglandular tissue using compartmentalized diffusion-weighted model: comparison of intravoxel incoherent motion and restriction spectrum imaging. Breast Cancer Res 2024; 26:71. [PMID: 38658999 PMCID: PMC11044413 DOI: 10.1186/s13058-024-01828-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 04/15/2024] [Indexed: 04/26/2024] Open
Abstract
BACKGROUND To compare the compartmentalized diffusion-weighted models, intravoxel incoherent motion (IVIM) and restriction spectrum imaging (RSI), in characterizing breast lesions and normal fibroglandular tissue. METHODS This prospective study enrolled 152 patients with 157 histopathologically verified breast lesions (41 benign and 116 malignant). All patients underwent a full-protocol preoperative breast MRI, including a multi-b-value DWI sequence. The diffusion parameters derived from the mono-exponential model (ADC), IVIM model (Dt, Dp, f), and RSI model (C1, C2, C3, C1C2, F1, F2, F3, F1F2) were quantitatively measured and then compared among malignant lesions, benign lesions and normal fibroglandular tissues using Kruskal-Wallis test. The Mann-Whitney U-test was used for the pairwise comparisons. Diagnostic models were built by logistic regression analysis. The ROC analysis was performed using five-fold cross-validation and the mean AUC values were calculated and compared to evaluate the discriminative ability of each parameter or model. RESULTS Almost all quantitative diffusion parameters showed significant differences in distinguishing malignant breast lesions from both benign lesions (other than C2) and normal fibroglandular tissue (all parameters) (all P < 0.0167). In terms of the comparisons of benign lesions and normal fibroglandular tissues, the parameters derived from IVIM (Dp, f) and RSI (C1, C2, C1C2, F1, F2, F3) showed significant differences (all P < 0.005). When using individual parameters, RSI-derived parameters-F1, C1C2, and C2 values yielded the highest AUCs for the comparisons of malignant vs. benign, malignant vs. normal tissue and benign vs. normal tissue (AUCs = 0.871, 0.982, and 0.863, respectively). Furthermore, the combined diagnostic model (IVIM + RSI) exhibited the highest diagnostic efficacy for the pairwise discriminations (AUCs = 0.893, 0.991, and 0.928, respectively). CONCLUSIONS Quantitative parameters derived from the three-compartment RSI model have great promise as imaging indicators for the differential diagnosis of breast lesions compared with the bi-exponential IVIM model. Additionally, the combined model of IVIM and RSI achieves superior diagnostic performance in characterizing breast lesions.
Collapse
Affiliation(s)
- Litong He
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, NO. 1095 Jiefang Avenue, Qiaokou District, Wuhan, 430030, China
| | - Yanjin Qin
- Department of Radiology, The First Affiliated Hospital, Sun Yat-sen University, 58th the Second Zhongshan Road, Guangzhou, 510080, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, NO. 1095 Jiefang Avenue, Qiaokou District, Wuhan, 430030, China
| | - Zhiqiang Liu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, NO. 1095 Jiefang Avenue, Qiaokou District, Wuhan, 430030, China
| | - Yunfei Zhang
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, NO. 1095 Jiefang Avenue, Qiaokou District, Wuhan, 430030, China.
| |
Collapse
|
3
|
Lemainque T. Editorial for "Effect of Phase Encoding Direction on Image Quality in Single-Shot EPI Diffusion-Weighted Imaging of the Breast". J Magn Reson Imaging 2024. [PMID: 38420670 DOI: 10.1002/jmri.29309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 12/06/2023] [Indexed: 03/02/2024] Open
Affiliation(s)
- Teresa Lemainque
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
4
|
Urut DU, Karabulut D, Hereklioglu S, Özdemir G, Cicin BA, Hacıoglu B, Süt N, Tunçbilek N. Diffusion tensor imaging: survival analysis prediction in breast cancer patients. RADIOLOGIE (HEIDELBERG, GERMANY) 2024:10.1007/s00117-023-01254-0. [PMID: 38277036 DOI: 10.1007/s00117-023-01254-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 11/14/2023] [Indexed: 01/27/2024]
Abstract
PURPOSE We aimed to explore the performance of diffusion-tensor imaging (DTI) and apparent diffusion coefficient (ADC) parameters in evaluating disease-free survival (DFS) and overall survival (OS) in patients with invasive breast cancer. MATERIAL AND METHODS A total of 49 women with invasive breast cancer who were diagnosed between 2017 and 2022 were included. All patients underwent breast magnetic resonance imaging (MRI) with DTI and diffusion-weighted imaging (DWI) features, with examiners blinded to the clinical data. Volume anisotropy (VA), fractional anisotropy (FA), and ADC values were measured to assess intratumoral measured heterogeneity. Correlations and differences in diffusion metrics according to OS and DFS status of the cases were analyzed. The discriminative ability of the quantitative findings was assessed by receiver operating characteristic (ROC) curve analyses and validated in the independent cohort. RESULTS We evaluated patients with metastases (n = 13, 36.5%) and those without metastases (n = 36, 73.5%). Differences in the ADC, FA, and VA values were observed. The results of Cox regression survival analysis for all the patients included in the survival analysis revealed that DTI metrics contributed to the prediction of overall survival (OS) in the emerging models (p < 0.05). Both FA and VA were associated with OS (p = 0.037 and p = 0.038, respectively). However, ADC was not associated with OS (p = 0.177) or DFS (p = 0.252). CONCLUSION To the best of our knowledge, this is the first study to assess the prognostic value of DTI-MRI in breast cancer with statistical survival analysis techniques. We believe that DTI measurements can be used as a biomarker for OS analysis in breast cancer given the available data.
Collapse
Affiliation(s)
- Devrim Ulaş Urut
- BHT Clinic İstanbul Tema Hospital Dep of Radiology, Istanbul Aydin University, Atakent mah. 4.cad. no: 36, 34307, Küçükçekmece/İstanbul, Turkey.
- Medical School Deparment of Radiology, Trakya University, Edirne, Turkey.
| | - Derya Karabulut
- Medical School Department of Radiology, Trakya University, Edirne, Turkey
| | - Savaş Hereklioglu
- Department of Radiology, Ataturk Training and Research Hospital, Erzurum, Turkey
| | - Gulşah Özdemir
- Medical School Department of Radiology, Trakya University, Edirne, Turkey
| | - Berkin Anıl Cicin
- Medical School Department of Medical Oncology, Trakya University, Edirne, Turkey
| | - Bekir Hacıoglu
- Medical School Department of Medical Oncology, Trakya University, Edirne, Turkey
| | - Necet Süt
- Medical School Dep of Biostatistics and Medical Informatics, Trakya University, Edirne, Turkey
| | - Nermin Tunçbilek
- Medical School Department of Radiology, Trakya University, Edirne, Turkey
| |
Collapse
|
5
|
Cheung SM, Wu WS, Senn N, Sharma R, McGoldrick T, Gagliardi T, Husain E, Masannat Y, He J. Towards detection of early response in neoadjuvant chemotherapy of breast cancer using Bayesian intravoxel incoherent motion. Front Oncol 2023; 13:1277556. [PMID: 38125950 PMCID: PMC10731248 DOI: 10.3389/fonc.2023.1277556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 11/21/2023] [Indexed: 12/23/2023] Open
Abstract
Introduction The early identification of good responders to neoadjuvant chemotherapy (NACT) holds a significant potential in the optimal treatment of breast cancer. A recent Bayesian approach has been postulated to improve the accuracy of the intravoxel incoherent motion (IVIM) model for clinical translation. This study examined the prediction and early sensitivity of Bayesian IVIM to NACT response. Materials and methods Seventeen female patients with breast cancer were scanned at baseline and 16 patients were scanned after Cycle 1. Tissue diffusion and perfusion from Bayesian IVIM were calculated at baseline with percentage change at Cycle 1 computed with reference to baseline. Cellular proliferative activity marker Ki-67 was obtained semi-quantitatively with percentage change at excision computed with reference to core biopsy. Results The perfusion fraction showed a significant difference (p = 0.042) in percentage change between responder groups at Cycle 1, with a decrease in good responders [-7.98% (-19.47-1.73), n = 7] and an increase in poor responders [10.04% (5.09-28.93), n = 9]. There was a significant correlation between percentage change in perfusion fraction and percentage change in Ki-67 (p = 0.042). Tissue diffusion and pseudodiffusion showed no significant difference in percentage change between groups at Cycle 1, nor was there a significant correlation against percentage change in Ki-67. Perfusion fraction, tissue diffusion, and pseudodiffusion showed no significant difference between groups at baseline, nor was there a significant correlation against Ki-67 from core biopsy. Conclusion The alteration in tumour perfusion fraction from the Bayesian IVIM model, in association with cellular proliferation, showed early sensitivity to good responders in NACT. Clinical trial registration https://clinicaltrials.gov/ct2/show/NCT03501394, identifier NCT03501394.
Collapse
Affiliation(s)
- Sai Man Cheung
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, United Kingdom
| | - Wing-Shan Wu
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, United Kingdom
| | - Nicholas Senn
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, United Kingdom
| | - Ravi Sharma
- Department of Oncology, Aberdeen Royal Infirmary, Aberdeen, United Kingdom
| | - Trevor McGoldrick
- Department of Oncology, Aberdeen Royal Infirmary, Aberdeen, United Kingdom
| | - Tanja Gagliardi
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, United Kingdom
- Department of Radiology, Royal Marsden Hospital, London, United Kingdom
| | - Ehab Husain
- Department of Pathology, Aberdeen Royal Infirmary, Aberdeen, United Kingdom
| | - Yazan Masannat
- Breast Unit, Aberdeen Royal Infirmary, Aberdeen, United Kingdom
| | - Jiabao He
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, United Kingdom
- Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
| |
Collapse
|
6
|
Stabinska J, Wittsack HJ, Lerman LO, Ljimani A, Sigmund EE. Probing Renal Microstructure and Function with Advanced Diffusion MRI: Concepts, Applications, Challenges, and Future Directions. J Magn Reson Imaging 2023:10.1002/jmri.29127. [PMID: 37991093 PMCID: PMC11117411 DOI: 10.1002/jmri.29127] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 11/23/2023] Open
Abstract
Diffusion measurements in the kidney are affected not only by renal microstructure but also by physiological processes (i.e., glomerular filtration, water reabsorption, and urine formation). Because of the superposition of passive tissue diffusion, blood perfusion, and tubular pre-urine flow, the limitations of the monoexponential apparent diffusion coefficient (ADC) model in assessing pathophysiological changes in renal tissue are becoming apparent and motivate the development of more advanced diffusion-weighted imaging (DWI) variants. These approaches take advantage of the fact that the length scale probed in DWI measurements can be adjusted by experimental parameters, including diffusion-weighting, diffusion gradient directions and diffusion time. This forms the basis by which advanced DWI models can be used to capture not only passive diffusion effects, but also microcirculation, compartmentalization, tissue anisotropy. In this review, we provide a comprehensive overview of the recent advancements in the field of renal DWI. Following a short introduction on renal structure and physiology, we present the key methodological approaches for the acquisition and analysis of renal DWI data, including intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI), non-Gaussian diffusion, and hybrid IVIM-DTI. We then briefly summarize the applications of these methods in chronic kidney disease and renal allograft dysfunction. Finally, we discuss the challenges and potential avenues for further development of renal DWI. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Lilach O. Lerman
- Division of Nephrology and Hypertension and Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Eric E. Sigmund
- Bernard and Irene Schwartz Center for Biomedical Imaging Center for Advanced Imaging Innovation and Research (CAI2R), New York University Langone Health, New York City, New York, USA
| |
Collapse
|
7
|
Moran CJ, Middione MJ, Mazzoli V, McKay-Nault JA, Guidon A, Waheed U, Rosen EL, Poplack SP, Rosenberg J, Ennis DB, Hargreaves BA, Daniel BL. Multishot Diffusion-Weighted MRI of the Breasts in the Supine vs. Prone Position. J Magn Reson Imaging 2023; 58:951-962. [PMID: 36583628 PMCID: PMC10310889 DOI: 10.1002/jmri.28582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 12/12/2022] [Accepted: 12/12/2022] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE Prospective. POPULATION Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc = 0.92). DATA CONCLUSION Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL 2. TECHNICAL EFFICACY Stage 1.
Collapse
Affiliation(s)
| | | | - Valentina Mazzoli
- Department of Radiology, Stanford University, Stanford, California, USA
| | | | - Arnaud Guidon
- Global MR Application and Workflow, GE Healthcare, Boston, Massachusetts, USA
| | - Uzma Waheed
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Eric L. Rosen
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Steven P. Poplack
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Jarrett Rosenberg
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Daniel B. Ennis
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Brian A. Hargreaves
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Bruce L. Daniel
- Department of Radiology, Stanford University, Stanford, California, USA
| |
Collapse
|
8
|
Wessling D, Gassenmaier S, Olthof SC, Benkert T, Weiland E, Afat S, Preibsch H. Novel deep-learning-based diffusion weighted imaging sequence in 1.5 T breast MRI. Eur J Radiol 2023; 166:110948. [PMID: 37481831 DOI: 10.1016/j.ejrad.2023.110948] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 06/14/2023] [Accepted: 06/21/2023] [Indexed: 07/25/2023]
Abstract
PURPOSE This study aimed to assess the technical feasibility, the impact on image quality, and the acquisition time (TA) of a new deep-learning-based reconstruction algorithm in diffusion weighted imaging (DWI) of breast magnetic resonance imaging (MRI). METHODS Retrospective analysis of 55 female patients who underwent breast DWI at 1.5 T. Raw data were reconstructed using a deep-learning (DL) reconstruction algorithm on a subset of the acquired averages, therefore a reduction of TA. Clinically used standard DWI sequence (DWIStd) and the DL-reconstructed images (DWIDL) were compared. Two radiologists rated the image quality of b800 and ADC images, using a Likert-scale from 1 to 5 with 5 being considered perfect image quality. Signal intensities were measured by placing a region of interest (ROI) at the same position in both sequences. RESULTS TA was reduced by 40 % in DWIDL, compared to DWIStd, DWIDL improved noise and sharpness while maintaining contrast, the level of artifacts, and diagnostic confidence. There were no differences regarding the signal intensity values of the apparent diffusion coefficient (ADC), (p = 0.955), b50-values (p = 0.070) and b800-values (p = 0.415) comparing standard and DL-imaging. Lesion assessment showed no differences regarding the number of lesions in ADC and DWI (both p = 1.000) and regarding the lesion diameter in DWI (p = 0.961;0.972) and ADC (p = 0.961;0.972). CONCLUSIONS The novel deep-learning-based reconstruction algorithm significantly reduces TA in breast DWI, while improving sharpness, reducing noise, and maintaining a comparable level of image quality, artifacts, contrast, and diagnostic confidence. DWIDL does not influence the quantifiable parameters.
Collapse
Affiliation(s)
- Daniel Wessling
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany; Department of Neuroradiology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany.
| | - Susann-Cathrin Olthof
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany.
| | - Thomas Benkert
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany.
| | - Elisabeth Weiland
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany.
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany.
| | - Heike Preibsch
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany.
| |
Collapse
|
9
|
Malyarenko D, Amouzandeh G, Pickup S, Zhou R, Manning HC, Gammon ST, Shoghi KI, Quirk JD, Sriram R, Larson P, Lewis MT, Pautler RG, Kinahan PE, Muzi M, Chenevert TL. Evaluation of Apparent Diffusion Coefficient Repeatability and Reproducibility for Preclinical MRIs Using Standardized Procedures and a Diffusion-Weighted Imaging Phantom. Tomography 2023; 9:375-386. [PMID: 36828382 PMCID: PMC9964373 DOI: 10.3390/tomography9010030] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/31/2023] [Accepted: 02/02/2023] [Indexed: 02/10/2023] Open
Abstract
Relevant to co-clinical trials, the goal of this work was to assess repeatability, reproducibility, and bias of the apparent diffusion coefficient (ADC) for preclinical MRIs using standardized procedures for comparison to performance of clinical MRIs. A temperature-controlled phantom provided an absolute reference standard to measure spatial uniformity of these performance metrics. Seven institutions participated in the study, wherein diffusion-weighted imaging (DWI) data were acquired over multiple days on 10 preclinical scanners, from 3 vendors, at 6 field strengths. Centralized versus site-based analysis was compared to illustrate incremental variance due to processing workflow. At magnet isocenter, short-term (intra-exam) and long-term (multiday) repeatability were excellent at within-system coefficient of variance, wCV [±CI] = 0.73% [0.54%, 1.12%] and 1.26% [0.94%, 1.89%], respectively. The cross-system reproducibility coefficient, RDC [±CI] = 0.188 [0.129, 0.343] µm2/ms, corresponded to 17% [12%, 31%] relative to the reference standard. Absolute bias at isocenter was low (within 4%) for 8 of 10 systems, whereas two high-bias (>10%) scanners were primary contributors to the relatively high RDC. Significant additional variance (>2%) due to site-specific analysis was observed for 2 of 10 systems. Base-level technical bias, repeatability, reproducibility, and spatial uniformity patterns were consistent with human MRIs (scaled for bore size). Well-calibrated preclinical MRI systems are capable of highly repeatable and reproducible ADC measurements.
Collapse
Affiliation(s)
- Dariya Malyarenko
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
| | - Ghoncheh Amouzandeh
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
- Neuro42, Inc., San Francisco, CA 94105, USA
| | - Stephen Pickup
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Rong Zhou
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Henry Charles Manning
- Department of Cancer Systems Imaging, The University of Texas MDACC, Houston, TX 77030, USA
| | - Seth T. Gammon
- Department of Cancer Systems Imaging, The University of Texas MDACC, Houston, TX 77030, USA
| | - Kooresh I. Shoghi
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
| | - James D. Quirk
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
| | - Renuka Sriram
- UCSF Department of Radiology & Biomedical Imaging, San Francisco, CA 94158, USA
| | - Peder Larson
- UCSF Department of Radiology & Biomedical Imaging, San Francisco, CA 94158, USA
| | | | | | - Paul E. Kinahan
- Department of Radiology, University of Washington, Seattle, WA 98195, USA
| | - Mark Muzi
- Department of Radiology, University of Washington, Seattle, WA 98195, USA
| | | |
Collapse
|