Kaza AK, Mondal A, Piekarski B, Sachse FB, Hitchcock R. Intraoperative localization of cardiac conduction tissue regions using real-time fibre-optic confocal microscopy: first in human trial. Eur J Cardiothorac Surg 2020; 58:261-268. [PMID: 32083653 DOI: 10.1093/ejcts/ezaa040] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 01/11/2020] [Accepted: 01/17/2020] [Indexed: 12/20/2022] Open
Abstract
OBJECTIVES The aim of this study was to evaluate the feasibility and safety of fibre-optic confocal microscopy (FCM) using fluorescein sodium dye for the intraoperative location of conduction tissue regions during paediatric heart surgery. METHODS The pilot study included 6 patients undergoing elective surgery for the closure of isolated secundum atrial septal defect aged 30 days to 21 years. FCM imaging was integrated within the normal intraoperative protocol for atrial septal defect repair. Fluorescein sodium dye was applied on the arrested heart. FCM images were acquired at the atrioventricular node region, sinus node region and right ventricle (RV). Total imaging time was limited to 3 min. Any adverse events related to the study were recorded and analysed. Subjects received standard postoperative care. Trained reviewers (n = 9) classified, de-identified and randomized FCM images (n = 60) recorded from the patients as presenting striated, reticulated or indistinguishable microstructures. The reliability of reviewer agreement was assessed using Fleiss' kappa. RESULTS The FCM imaging instruments were integrated effectively into the cardiac surgery operating room. All adverse events found in the study were deemed expected and not related to FCM imaging. Reticulated myocardial microstructures were found during FCM imaging at atrioventricular node and sinus node regions, while striated microstructures were observed in RV. Reliability of agreement of reviewers classifying the FCM images was high (Fleiss' kappa: 0.822). CONCLUSIONS FCM using fluorescein sodium dye was found to be safe for use during paediatric heart surgery. The study demonstrates the potential for FCM to be effective in identifying conduction tissue regions during congenital heart surgery. CLINICAL TRIAL REGISTRATION NUMBER NCT03189134.
Collapse
Affiliation(s)
- Aditya K Kaza
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Abhijit Mondal
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Breanna Piekarski
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Frank B Sachse
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah, Salt Lake City, UT, USA
| | - Robert Hitchcock
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
2
|
Mondal A, Lackey J, Saeed M, Wu FY, Johnson JK, Huang C, Sachse FB, Hitchcock R, Kaza AK. An Imaging Protocol to Discriminate Specialized Conduction Tissue During Congenital Heart Surgery. Semin Thorac Cardiovasc Surg 2019; 31:537-546. [PMID: 30738149 DOI: 10.1053/j.semtcvs.2019.02.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 02/01/2019] [Indexed: 12/20/2022]
Abstract
We performed preclinical validation of intraoperative fiber-optic confocal microscopy (FCM) and assessed its safety and efficacy in an ovine model of the pediatric heart. Intraoperative imaging was performed using an FCM system (Cellvizio, Mauna Kea Technology, Paris, France) with specialized imaging miniprobe (GastroFlex UHD, Mauna Kea Technologies). Before imaging, we applied an extracellular fluorophore, sodium fluorescein, to fluorescently label extracellular space. We imaged arrested hearts of ovine (1-6 months) under cardiopulmonary bypass. Image sequences (1-10 seconds duration) were acquired from regions of the sinoatrial and atrioventricular node, as well as subepicardial and subendocardial working myocardium from atria and ventricle. The surgical process was evaluated for integration of the imaging protocol during the operative procedure. In addition, fluorescein cardiotoxicity studies (n = 3 animals) were conducted by comparing electrocardiogram (PR and QRS intervals) and ejection fraction at baseline and after topical application of fluorescein at 1:10, 1:100, and 1:1000 dilutions on a beating ovine heart. Our studies suggest that intraoperative FCM can be used to identify regions associated with specialized conducting tissue in ovine hearts in situ. The imaging protocol was integrated with conventional open heart surgical procedures with minimal changes to the operative process. Application of fluorescein in varying concentrations did not affect the normalized PR interval, QRS interval, and ejection fraction. These preclinical validation studies demonstrated both safety and efficacy of the proposed intraoperative imaging approach. The studies constitute an important step toward first-in-human clinical trials.
Collapse
Affiliation(s)
- Abhijit Mondal
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts
| | - John Lackey
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah
| | - Mossab Saeed
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts
| | - Fei-Yi Wu
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Jordan K Johnson
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah; Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah, Salt Lake City, Utah
| | - Chao Huang
- Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah, Salt Lake City, Utah; Comprehensive Arrhythmia and Research Management (CARMA) Center, University of Utah, Salt Lake City, Utah
| | - Frank B Sachse
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah; Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah, Salt Lake City, Utah
| | - Robert Hitchcock
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah
| | - Aditya K Kaza
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts; Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah
| |
Collapse
|
3
|
Sensitivity and Specificity of Cardiac Tissue Discrimination Using Fiber-Optics Confocal Microscopy. PLoS One 2016; 11:e0147667. [PMID: 26808149 PMCID: PMC4725960 DOI: 10.1371/journal.pone.0147667] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Accepted: 01/06/2016] [Indexed: 12/20/2022] Open
Abstract
Disturbances of the cardiac conduction system constitute a major risk after surgical repair of complex cases of congenital heart disease. Intraoperative identification of the conduction system may reduce the incidence of these disturbances. We previously developed an approach to identify cardiac tissue types using fiber-optics confocal microscopy and extracellular fluorophores. Here, we applied this approach to investigate sensitivity and specificity of human and automated classification in discriminating images of atrial working myocardium and specialized tissue of the conduction system. Two-dimensional image sequences from atrial working myocardium and nodal tissue of isolated perfused rodent hearts were acquired using a fiber-optics confocal microscope (Leica FCM1000). We compared two methods for local application of extracellular fluorophores: topical via pipette and with a dye carrier. Eight blinded examiners evaluated 162 randomly selected images of atrial working myocardium (n = 81) and nodal tissue (n = 81). In addition, we evaluated the images using automated classification. Blinded examiners achieved a sensitivity and specificity of 99.2±0.3% and 98.0±0.7%, respectively, with the dye carrier method of dye application. Sensitivity and specificity was similar for dye application via a pipette (99.2±0.3% and 94.0±2.4%, respectively). Sensitivity and specificity for automated methods of tissue discrimination were similarly high. Human and automated classification achieved high sensitivity and specificity in discriminating atrial working myocardium and nodal tissue. We suggest that our findings facilitate clinical translation of fiber-optics confocal microscopy as an intraoperative imaging modality to reduce the incidence of conduction disturbances during surgical correction of congenital heart disease.