1
|
Othman GB, Ynineb AR, Yumuk E, Farbakhsh H, Muresan C, Birs IR, De Raeve A, Copot C, Ionescu CM, Copot D. Artificial Intelligence-Driven Prognosis of Respiratory Mechanics: Forecasting Tissue Hysteresivity Using Long Short-Term Memory and Continuous Sensor Data. SENSORS (BASEL, SWITZERLAND) 2024; 24:5544. [PMID: 39275455 PMCID: PMC11397974 DOI: 10.3390/s24175544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 08/22/2024] [Accepted: 08/24/2024] [Indexed: 09/16/2024]
Abstract
Tissue hysteresivity is an important marker for determining the onset and progression of respiratory diseases, calculated from forced oscillation lung function test data. This study aims to reduce the number and duration of required measurements by combining multivariate data from various sensing devices. We propose using the Forced Oscillation Technique (FOT) lung function test in both a low-frequency prototype and the commercial RESMON device, combined with continuous monitoring from the Equivital (EQV) LifeMonitor and processed by artificial intelligence (AI) algorithms. While AI and deep learning have been employed in various aspects of respiratory system analysis, such as predicting lung tissue displacement and respiratory failure, the prediction or forecasting of tissue hysteresivity remains largely unexplored in the literature. In this work, the Long Short-Term Memory (LSTM) model is used in two ways: (1) to estimate the hysteresivity coefficient η using heart rate (HR) data collected continuously by the EQV sensor, and (2) to forecast η values by first predicting the heart rate from electrocardiogram (ECG) data. Our methodology involves a rigorous two-hour measurement protocol, with synchronized data collection from the EQV, FOT, and RESMON devices. Our results demonstrate that LSTM networks can accurately estimate the tissue hysteresivity parameter η, achieving an R2 of 0.851 and a mean squared error (MSE) of 0.296 for estimation, and forecast η with an R2 of 0.883 and an MSE of 0.528, while significantly reducing the number of required measurements by a factor of three (i.e., from ten to three) for the patient. We conclude that our novel approach minimizes patient effort by reducing the measurement time and the overall ambulatory time and costs while highlighting the potential of artificial intelligence methods in respiratory monitoring.
Collapse
Affiliation(s)
- Ghada Ben Othman
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
| | - Amani R Ynineb
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
| | - Erhan Yumuk
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
- Department of Control and Automation Engineering, Istanbul Technical University, Maslak, Istanbul 34469, Turkey
| | - Hamed Farbakhsh
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
| | - Cristina Muresan
- Department of Automation, Technical University Cluj-Napoca, Memorandumului Street 20, 400114 Cluj, Romania
| | - Isabela Roxana Birs
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
- Department of Automation, Technical University Cluj-Napoca, Memorandumului Street 20, 400114 Cluj, Romania
| | - Alexandra De Raeve
- Fashion, Textiles and Innovation Lab (FTILab+), HOGENT University of Applied Science and Arts, Buchtenstraat 11, 9051 Ghent, Belgium
| | - Cosmin Copot
- Fashion, Textiles and Innovation Lab (FTILab+), HOGENT University of Applied Science and Arts, Buchtenstraat 11, 9051 Ghent, Belgium
| | - Clara M Ionescu
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
- Department of Automation, Technical University Cluj-Napoca, Memorandumului Street 20, 400114 Cluj, Romania
| | - Dana Copot
- Department of Electromechanics, System and Metal Engineering, Ghent University, Tech Lane Science Park 125, 9052 Ghent, Belgium
- Department of Automation, Technical University Cluj-Napoca, Memorandumului Street 20, 400114 Cluj, Romania
| |
Collapse
|
2
|
Gauvrit S, Bossaer J, Lee J, Collins MM. Modeling Human Cardiac Arrhythmias: Insights from Zebrafish. J Cardiovasc Dev Dis 2022; 9:jcdd9010013. [PMID: 35050223 PMCID: PMC8779270 DOI: 10.3390/jcdd9010013] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 12/23/2021] [Accepted: 12/25/2021] [Indexed: 12/13/2022] Open
Abstract
Cardiac arrhythmia, or irregular heart rhythm, is associated with morbidity and mortality and is described as one of the most important future public health challenges. Therefore, developing new models of cardiac arrhythmia is critical for understanding disease mechanisms, determining genetic underpinnings, and developing new therapeutic strategies. In the last few decades, the zebrafish has emerged as an attractive model to reproduce in vivo human cardiac pathologies, including arrhythmias. Here, we highlight the contribution of zebrafish to the field and discuss the available cardiac arrhythmia models. Further, we outline techniques to assess potential heart rhythm defects in larval and adult zebrafish. As genetic tools in zebrafish continue to bloom, this model will be crucial for functional genomics studies and to develop personalized anti-arrhythmic therapies.
Collapse
|