1
|
Song A, Kim MJ, Yi DJ, Kwon S, Kim DW, Kim S, Bae JH, Park S, Rim YS, Jeong KS, Chung KB. Control of sensitivity in metal oxide electrolyte gated field-effect transistor-based glucose sensor by electronegativity modulation. Sci Rep 2024; 14:27251. [PMID: 39516503 PMCID: PMC11549364 DOI: 10.1038/s41598-024-76885-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Accepted: 10/17/2024] [Indexed: 11/16/2024] Open
Abstract
In this study, the sensitivity of electrolyte-gated field-effect transistor-based glucose sensors using oxide semiconductor materials was controlled via electronegativity modulation. By controlling the enzymatic reaction between glucose and glucose oxidase, which is affected by the surface potential, the sensitivity of the glucose sensor can be effectively adjusted. To evaluate the sensitivity characteristics of the glucose sensor according to electronegativity control, devices were fabricated based on InO through Ga and Zn doping. The results confirmed that the specific sensitivity range could be adjusted by increasing the electronegativity. In addition, density functional theory calculations, confirmed that the attachment energy of the surface-functionalized material and the enzyme binding energy in the surface-functionalized thin film can be modulated depending on the electronegativity difference. The dissociation constant was controlled in both directions by doping with metal cations with larger(Ga, 1.81) or smaller(Zn, 1.65) electronegativities in InO(In, 1.78). We expect that this study will provide a simple method for the gradual and bidirectional control of the glucose sensitivity region.
Collapse
Affiliation(s)
- Aeran Song
- Division of Physics and Semiconductor Science, Dongguk University, Seoul, 100-715, Republic of Korea
| | - Min Jung Kim
- Division of Physics and Semiconductor Science, Dongguk University, Seoul, 100-715, Republic of Korea
| | - Dong-Joon Yi
- Division of Physics and Semiconductor Science, Dongguk University, Seoul, 100-715, Republic of Korea
| | - Soyeong Kwon
- Department of Physics, Ewha Womans University, Seoul, 03760, Republic of Korea
| | - Dong-Wook Kim
- Department of Physics, Ewha Womans University, Seoul, 03760, Republic of Korea
| | - Seunghwan Kim
- Advanced Analysis and Data Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Jee-Hwan Bae
- Advanced Analysis and Data Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Soohyung Park
- Advanced Analysis and Data Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - You Seung Rim
- Department of Intelligent Mechatronics Engineering and Convergence Engineering for Intelligent Drone, Department of Semiconductor Systems Engineering, Sejong University, Seoul, 05006, Republic of Korea.
| | - Kwang-Sik Jeong
- Division of AI Semiconductor, Yonsei University, Wonju, 26493, Republic of Korea.
| | - Kwun-Bum Chung
- Division of Physics and Semiconductor Science, Dongguk University, Seoul, 100-715, Republic of Korea.
| |
Collapse
|
2
|
Wu M, Li L, Yu R, Zhang Z, Zhu B, Lin J, Zhou L, Su B. Tailored diffusion limiting membrane for microneedle glucose sensors with wide linear range. Talanta 2024; 273:125933. [PMID: 38503127 DOI: 10.1016/j.talanta.2024.125933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/20/2024] [Accepted: 03/14/2024] [Indexed: 03/21/2024]
Abstract
Continuous glucose monitoring is very important to daily blood glucose control in diabetic patients, but its accuracy is limited by the narrow linear range of the response of biosensor to the glucose concentration because of the oxygen starvation in tissue and the limited maximum conversion rate of glucose oxidase. In this work, a biocompatible diffusion limiting membrane based on two medical-grade polyurethanes is developed via blending modification to restrict the diffusion flux of glucose to match the oxygen concentration and the maximum conversion rate. The expansiveness of the linear range for the nanomaterials-modified electrode in the glucose biosensor can be achieved through the regulation of two polyurethanes, the solvent, and the thickness of the membrane. In addition, the mass transport of hydrogen peroxide and interfering substances is also limited of the membrane. The in vitro experiments demonstrated that the membrane-modified microneedle biosensor exhibited a rapid response to the concentration variation of glucose, a wide linear range that is sufficient to cover the blood concentration of healthy and diabetic people, the ability to resist the oxygen concentration fluctuation and interfering substances, good reproducibility and long-term stability. The custom wearable electrochemical system, possessing these characteristics, has been proven to accurately monitor the blood concentration in a living rat in real time. This demonstrates a significant potential for application in both daily and clinical blood glucose monitoring.
Collapse
Affiliation(s)
- Minfang Wu
- Department of Chemistry, Zhejiang University, Hangzhou, 310058, China; Internet of Things Research Center Advanced Institute of Information Technology, Peking University, Hangzhou, 310058, China
| | - Liang Li
- Internet of Things Research Center Advanced Institute of Information Technology, Peking University, Hangzhou, 310058, China
| | - Rongying Yu
- Internet of Things Research Center Advanced Institute of Information Technology, Peking University, Hangzhou, 310058, China
| | - Zebo Zhang
- Internet of Things Research Center Advanced Institute of Information Technology, Peking University, Hangzhou, 310058, China
| | - Boyu Zhu
- Department of Chemistry, Zhejiang University, Hangzhou, 310058, China
| | - Junshu Lin
- Internet of Things Research Center Advanced Institute of Information Technology, Peking University, Hangzhou, 310058, China
| | - Lin Zhou
- Department of Chemistry, Zhejiang University, Hangzhou, 310058, China
| | - Bin Su
- Department of Chemistry, Zhejiang University, Hangzhou, 310058, China.
| |
Collapse
|
3
|
Thongkhao P, Numnuam A, Khongkow P, Sangkhathat S, Phairatana T. Disposable Polyaniline/ m-Phenylenediamine-Based Electrochemical Lactate Biosensor for Early Sepsis Diagnosis. Polymers (Basel) 2024; 16:473. [PMID: 38399851 PMCID: PMC10892424 DOI: 10.3390/polym16040473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/26/2024] [Accepted: 02/06/2024] [Indexed: 02/25/2024] Open
Abstract
Lactate serves as a crucial biomarker that indicates sepsis assessment in critically ill patients. A rapid, accurate, and portable analytical device for lactate detection is required. This work developed a stepwise polyurethane-polyaniline-m-phenylenediamine via a layer-by-layer based electrochemical biosensor, using a screen-printed gold electrode for lactate determination in blood samples. The developed lactate biosensor was electrochemically fabricated with layers of m-phenylenediamine, polyaniline, a crosslinking of a small amount of lactate oxidase via glutaraldehyde, and polyurethane as an outer membrane. The lactate determination using amperometry revealed the biosensor's performance with a wide linear range of 0.20-5.0 mmol L-1, a sensitivity of 12.17 ± 0.02 µA·mmol-1·L·cm-2, and a detection limit of 7.9 µmol L-1. The developed biosensor exhibited a fast response time of 5 s, high selectivity, excellent long-term storage stability over 10 weeks, and good reproducibility with 3.74% RSD. Additionally, the determination of lactate in human blood plasma using the developed lactate biosensor was examined. The results were in agreement with the enzymatic colorimetric gold standard method (p > 0.05). Our developed biosensor provides efficiency, reliability, and is a great potential tool for advancing lactate point-of-care testing applications in the early diagnosis of sepsis.
Collapse
Affiliation(s)
- Piromya Thongkhao
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| | - Apon Numnuam
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Songkhla 90110, Thailand
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Songkhla 90110, Thailand
| | - Pasarat Khongkow
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
- Translational Medicine Research Center, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| | - Surasak Sangkhathat
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
- Translational Medicine Research Center, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
- Department of Surgery, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
| | - Tonghathai Phairatana
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| |
Collapse
|
4
|
Sharma A, AlGhamdi WS, Faber H, Lin YH, Liu CH, Hsu EK, Lin WZ, Naphade D, Mandal S, Heeney M, Anthopoulos TD. Non-invasive, ultrasensitive detection of glucose in saliva using metal oxide transistors. Biosens Bioelectron 2023; 237:115448. [PMID: 37348190 DOI: 10.1016/j.bios.2023.115448] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 05/06/2023] [Accepted: 06/02/2023] [Indexed: 06/24/2023]
Abstract
Transistor-based biosensors represent an emerging technology for inexpensive point-of-care testing (POCT) applications. However, the limited sensitivity of the current transistor technologies hinders their practical deployment. In this study, we developed tri-channel In2O3/ZnO heterojunction thin-film transistors (TFTs) featuring the surface-immobilized enzyme glucose oxidase to detect glucose in various biofluids. This unusual channel design facilitates strong coupling between the electrons transported along the buried In2O3/ZnO heterointerface and the electrostatic perturbations caused by the interactions between glucose and surface-immobilized glucose oxidase. The enzyme selectively binds to glucose, causing a change in charge density on the channel surface. By exploring this effect, the solid-state biosensing TFT (BioTFT) can selectively detect glucose in artificial and real saliva over a wide range of concentrations from 500 nM to 20 mM with limits of detection of ∼365 pM (artificial saliva) and ∼416 nM (real saliva) in less than 60 s. The specificity of the sensor towards glucose has been demonstrated against various interfering species in artificial saliva, further highlighting its unique capabilities. Moreover, the BioTFTs exhibited good operating stability upon storage for up to two weeks, with relative standard deviation (RSD) values ranging from 2.36% to 6.39% for 500 nM glucose concentration. Our BioTFTs are easy to manufacture with reliable operation, making them ideal for non-invasive POCT applications.
Collapse
Affiliation(s)
- Abhinav Sharma
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia.
| | - Wejdan S AlGhamdi
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia
| | - Hendrik Faber
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia
| | - Yen-Hung Lin
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Chien-Hao Liu
- Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - En-Kai Hsu
- Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Wei-Zhi Lin
- Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Dipti Naphade
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia
| | - Suman Mandal
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia
| | - Martin Heeney
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia
| | - Thomas D Anthopoulos
- King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal 23955-6900, Saudi Arabia.
| |
Collapse
|
5
|
He T, Wen F, Yang Y, Le X, Liu W, Lee C. Emerging Wearable Chemical Sensors Enabling Advanced Integrated Systems toward Personalized and Preventive Medicine. Anal Chem 2023; 95:490-514. [PMID: 36625107 DOI: 10.1021/acs.analchem.2c04527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Tianyiyi He
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.,Center for Intelligent Sensors and MEMS, National University of Singapore, Block E6 #05-11, 5 Engineering Drive 1, Singapore 117608, Singapore
| | - Feng Wen
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.,Center for Intelligent Sensors and MEMS, National University of Singapore, Block E6 #05-11, 5 Engineering Drive 1, Singapore 117608, Singapore
| | - Yanqin Yang
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.,Center for Intelligent Sensors and MEMS, National University of Singapore, Block E6 #05-11, 5 Engineering Drive 1, Singapore 117608, Singapore
| | - Xianhao Le
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.,Center for Intelligent Sensors and MEMS, National University of Singapore, Block E6 #05-11, 5 Engineering Drive 1, Singapore 117608, Singapore
| | - Weixin Liu
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.,Center for Intelligent Sensors and MEMS, National University of Singapore, Block E6 #05-11, 5 Engineering Drive 1, Singapore 117608, Singapore
| | - Chengkuo Lee
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.,Center for Intelligent Sensors and MEMS, National University of Singapore, Block E6 #05-11, 5 Engineering Drive 1, Singapore 117608, Singapore
| |
Collapse
|