1
|
Ahmad S, Ahmad T. AQI prediction using layer recurrent neural network model: a new approach. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1180. [PMID: 37690033 DOI: 10.1007/s10661-023-11646-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 07/25/2023] [Indexed: 09/12/2023]
Abstract
The air quality index (AQI) prediction is important to evaluate the effects of air pollutants on human health. The airborne pollutants have been a major threat in Delhi both in the past and coming years. The air quality index is a figure, based on the cumulative effect of major air pollutant concentrations, used by Government agencies, for air quality assessment. Thus, the main aim of the present study is to predict the daily AQI one year in advance through three different neural network models (FF-NN, CF-NN and LR-NN) for the year 2020 and compare them. The models were trained using AQI values of previous year (2019). In addition to main air pollutants like PM10/PM2.5, O3, SO2, NOx, CO and NH3, the non-criteria pollutants and meteorological data were also included as input parameter in this study. The model performances were assessed using statistical analysis. The key air pollutants contributing to high level of daily AQI were found to be PM2.5/PM10, CO and NO2. The root mean square error (RMSE) values of 31.86 and 28.03 were obtained for the FF-NN and CF-NN models respectively whereas the LR-NN model has the minimum RMSE value of 26.79. LR-NN algorithm predicted the AQI values very closely to the actual values in almost all the seasons of the year. The LR-NN performance was also found to be the best in post-monsoon season i.e., October and November (maximum R2 = 0.94) with respect to other seasons. The study would aid air pollution control authorities to predict AQI more precisely and adopt suitable pollution control measures. Further research studies are recommended to compare the performance of LR-NN model with statistical, numerical and computational models for accurate air quality assessment.
Collapse
Affiliation(s)
- Shadab Ahmad
- Department of Civil Engineering, Bharat Institute of Engineering and Technology, Hyderabad, Telangana, India
| | - Tarique Ahmad
- Department of Civil Engineering, College of Engineering, Jazan University, Jazan, 45142, Saudi Arabia.
| |
Collapse
|
2
|
Graça D, Reis J, Gama C, Monteiro A, Rodrigues V, Rebelo M, Borrego C, Lopes M, Miranda AI. Sensors Network as an Added Value for the Characterization of Spatial and Temporal Air Quality Patterns at the Urban Scale. SENSORS (BASEL, SWITZERLAND) 2023; 23:1859. [PMID: 36850456 PMCID: PMC9967040 DOI: 10.3390/s23041859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 02/03/2023] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Within the scope of the Aveiro STEAM City project, an air quality monitoring network was installed in the city of Aveiro (Portugal), to evaluate the potential of sensors to characterize spatial and temporal patterns of air quality in the city. The network consists of nine sensors stations with air quality sensors (PM10, PM2.5, NO2, O3 and CO) and two meteorological stations, distributed within selected locations in the city of Aveiro. The analysis of the data was done for a one-year measurement period, from June 2020 to May 2021, using temporal profiles, statistical comparisons with reference stations and Air Quality Indexes (AQI). The analysis of sensors data indicated that air quality variability exists for all pollutants and stations. The majority of the study area is characterized by good air quality, but specific areas-associated with hotspot traffic zones-exhibit medium, poor and bad air quality more frequently. The daily patterns registered are significantly different between the affected and non-affected road traffic sites, mainly for PM and NO2 pollutants. The weekly profile, significative deltas are found between week and weekend: NO2 is reduced on the weekends at traffic sites, but PM10 is higher in specific areas during winter weekends, which is explained by residential combustion sources.
Collapse
|
3
|
Zamora ML, Buehler C, Lei H, Datta A, Xiong F, Gentner DR, Koehler K. Evaluating the Performance of Using Low-Cost Sensors to Calibrate for Cross-Sensitivities in a Multipollutant Network. ACS ES&T ENGINEERING 2022; 2:780-793. [PMID: 35937506 PMCID: PMC9355096 DOI: 10.1021/acsestengg.1c00367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
As part of our low-cost sensor network, we colocated multipollutant monitors containing sensors for particulate matter, carbon monoxide, ozone, nitrogen dioxide, and nitrogen monoxide at a reference field site in Baltimore, MD, for 1 year. The first 6 months were used for training multiple regression models, and the second 6 months were used to evaluate the models. The models produced accurate hourly concentrations for all sensors except ozone, which likely requires nonlinear methods to capture peak summer concentrations. The models for all five pollutants produced high Pearson correlation coefficients (r > 0.85), and the hourly averaged calibrated sensor and reference concentrations from the evaluation period were within 3-12%. Each sensor required a distinct set of predictors to achieve the lowest possible root-mean-square error (RMSE). All five sensors responded to environmental factors, and three sensors exhibited cross-sensitives to another air pollutant. We compared the RMSE from models (NO2, O3, and NO) that used colocated regulatory instruments and colocated sensors as predictors to address the cross-sensitivities to another gas, and the corresponding model RMSEs for the three gas models were all within 0.5 ppb. This indicates that low-cost sensor networks can yield useable data if the monitoring package is designed to comeasure key predictors. This is key for the utilization of low-cost sensors by diverse audiences since this does not require continual access to regulatory grade instruments.
Collapse
Affiliation(s)
- Misti Levy Zamora
- Department of Public Health Sciences UConn School of Medicine, University of Connecticut Health Center, Farmington, Connecticut 06032-1941, United States; Environmental Health and Engineering, Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland 21205-2103, United States; SEARCH (Solutions for Energy, Air, Climate and Health) Center, Yale University, New Haven, Connecticut 06520, United States
| | - Colby Buehler
- SEARCH (Solutions for Energy, Air, Climate and Health) Center, Yale University, New Haven, Connecticut 06520, United States; Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06520, United States
| | - Hao Lei
- Environmental Health and Engineering, Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland 21205-2103, United States
| | - Abhirup Datta
- Department of Biostatistics, Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland 21205-2103, United States
| | - Fulizi Xiong
- SEARCH (Solutions for Energy, Air, Climate and Health) Center, Yale University, New Haven, Connecticut 06520, United States; Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06520, United States
| | - Drew R Gentner
- SEARCH (Solutions for Energy, Air, Climate and Health) Center, Yale University, New Haven, Connecticut 06520, United States; Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06520, United States
| | - Kirsten Koehler
- Environmental Health and Engineering, Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland 21205-2103, United States; SEARCH (Solutions for Energy, Air, Climate and Health) Center, Yale University, New Haven, Connecticut 06520, United States
| |
Collapse
|
4
|
Abstract
Nowadays, observing, recording, and modeling the dynamics of atmospheric pollutants represent actual study areas given the effects of pollution on the population and ecosystems. The existence of aberrant values may influence reports on air quality when they are based on average values over a period. This may also influence the quality of models, which are further used in forecasting. Therefore, correct data collection and analysis is necessary before modeling. This study aimed to detect aberrant values in a nitrogen oxide concentration series recorded in the interval 1 January–8 June 2016 in Timisoara, Romania, and retrieved from the official reports of the National Network for Monitoring the Air Quality, Romania. Four methods were utilized, including the interquartile range (IQR), isolation forest, local outlier factor (LOF) methods, and the generalized extreme studentized deviate (GESD) test. Autoregressive integrated moving average (ARIMA), Generalized Regression Neural Networks (GRNN), and hybrid ARIMA-GRNN models were built for the series before and after the removal of aberrant values. The results show that the first approach provided a good model (from a statistical viewpoint) for the series after the anomalies removal. The best model was obtained by the hybrid ARIMA-GRNN. For example, for the raw NO2 series, the ARIMA model was not statistically validated, whereas, for the series without outliers, the ARIMA(1,1,1) was validated. The GRNN model for the raw series was able to learn the data well: R2 = 76.135%, the correlation between the actual and predicted values (rap) was 0.8778, the mean standard errors (MSE) = 0.177, the mean absolute error MAE = 0.2839, and the mean absolute percentage error MAPE = 9.9786. Still, on the test set, the results were worse: MSE = 1.5101, MAE = 0.8175, rap = 0.4482. For the series without outliers, the model was able to learn the data in the training set better than for the raw series (R2 = 0.996), whereas, on the test set, the results were not very good (R2 = 0.473). The performances of the hybrid ARIMA–GRNN on the initial series were not satisfactory on the test (the pattern of the computed values was almost linear) but were very good on the series without outliers (the correlation between the predicted values on the test set was very close to 1). The same was true for the models built for O3.
Collapse
|
5
|
Embedded Generative Air Pollution Model with Variational Autoencoder and Environmental Factor Effect in Ulaanbaatar City. ATMOSPHERE 2021. [DOI: 10.3390/atmos13010071] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Air pollution is one of the most pressing modern-day issues in cities around the world. However, most cities have adopted air quality measurement devices that only measure the past pollution levels without paying attention to the influencing factors. To obtain preliminary pollution information with regard to environmental factors, we developed a variational autoencoder and feedforward neural network-based embedded generative model to examine the relationship between air quality and the effects of environmental factors. In the model, actual SO2, NO2, PM2.5, PM10, and CO measurements from 2016 to 2020 were used, which were assembled from 15 differently located ground monitoring stations in Ulaanbaatar city. A wide range of weather and fuel measurements were used as the data for the influencing factors, and were collected over the same period as the air pollution data were recorded. The prediction results concerned all measurement stations, and the results were visualized as a spatial–temporal distribution of pollution and the performance of individual stations. A cross-validated R2 was used to estimate the entire pollution distribution through the regions as SO2: 0.81, PM2.5: 0.76, PM10: 0.89, and CO: 0.83. Pearson’s chi-squared tests were used for assessing each measurement station, and the contingency tables represent a high correlation between the actual and model results. The model can be applied to perform specific analysis of the interdependencies between pollution and environmental factors, and the performance of the model improves with long-range data.
Collapse
|
6
|
Hernandez W, Mendez A. Twelve-Year Analysis of NO 2 Concentration Measurements at Belisario Station (Quito, Ecuador) Using Statistical Inference Techniques. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5831. [PMID: 33076389 PMCID: PMC7602597 DOI: 10.3390/s20205831] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 10/10/2020] [Accepted: 10/13/2020] [Indexed: 11/25/2022]
Abstract
In this paper, a robust analysis of nitrogen dioxide (NO2) concentration measurements taken at Belisario station (Quito, Ecuador) was performed. The data used for the analysis constitute a set of measurements taken from 1 January 2008 to 31 December 2019. Furthermore, the analysis was carried out in a robust way, defining variables that represent years, months, days and hours, and classifying these variables based on estimates of the central tendency and dispersion of the data. The estimators used here were classic, nonparametric, based on a bootstrap method, and robust. Additionally, confidence intervals based on these estimators were built, and these intervals were used to categorize the variables under study. The results of this research showed that the NO2 concentration at Belisario station is not harmful to humans. Moreover, it was shown that this concentration tends to be stable across the years, changes slightly during the days of the week, and varies greatly when analyzed by months and hours of the day. Here, the precision provided by both nonparametric and robust statistical methods served to comprehensively proof the aforementioned. Finally, it can be concluded that the city of Quito is progressing on the right path in terms of improving air quality, because it has been shown that there is a decreasing tendency in the NO2 concentration across the years. In addition, according to the Quito Air Quality Index, most of the observations are in either the desirable level or acceptable level of air pollution, and the number of observations that are in the desirable level of air pollution increases across the years.
Collapse
Affiliation(s)
- Wilmar Hernandez
- Facultad de Ingeniería y Ciencias Aplicadas, Universidad de Las Américas, Quito 170125, Ecuador
| | - Alfredo Mendez
- Departamento de Matemática Aplicada a las Tecnologías de la Información y las Comunicaciones, ETS de Ingeniería y Sistemas de Telecomunicación, Universidad Politécnica de Madrid, 28031 Madrid, Spain;
| |
Collapse
|