1
|
Kumar P, Hama S, Cheung HYW, Hadjichristodoulou C, Mouchtouri VA, Anagnostopoulos L, Kourentis L, Wang Z, Galea ER, Ewer J, Grandison A, Jia F, Siilin N. Airborne pathogen monitoring and dispersion modelling on passenger ships: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2025; 980:179571. [PMID: 40318375 DOI: 10.1016/j.scitotenv.2025.179571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2025] [Revised: 04/08/2025] [Accepted: 04/28/2025] [Indexed: 05/07/2025]
Abstract
The COVID-19 pandemic demonstrated a profound inability of pre-pandemic passenger ship policies implemented by both ship operators and governmental authorities to detect and address newly emerging diseases. The essentiality of maritime transport puts into focus the risk of approach to address known and new emerging airborne infectious diseases that, due to increasing capacity, are likely to occur on passenger ships. In order to enhance the passenger experience, prepare shipping for pandemics like COVID-19, and improve the resilience and safety of the industry, this review critically synthesises existing literature on (1) monitoring ventilation conditions and aerosol dispersion, linking them to airborne transmission risk using airborne aerosols and ventilation performance as input parameters for computational fluid dynamics (CFD) simulations, and (2) modelling airborne disease transmission risk in controlled passenger ship environments. This review analysed 39 studies on aerosol monitoring, thermal comfort, and infection risk modelling on passenger ships (2000-2023). Additionally, 55 papers on CFD modelling of airborne pathogen dispersion were reviewed: 22 included validation, with most focused on built environments and only four specifically addressing ship environments. Two major challenges relate to the complexity and poorly characterised ventilation boundary conditions on passenger ships, and the other is the lack of suitable validation data. For this reason, ship experimental studies are required for CFD model validation. Only a handful of studies were found that have measured aerosol concentrations on board passenger ships. To the best of our knowledge, there have been no studies conducted on aerosol mass or airborne transmission sampling on board passenger ships or other types of vessels. The results of this review have the potential to create synergistic connections between experimental and modelling studies to inform, characterise and improve the development of numerical models that can accurately estimate infection risk on ships for prevention, mitigation and management of outbreaks.
Collapse
Affiliation(s)
- Prashant Kumar
- Global Centre for Clean Air Research (GCARE), School of Engineering, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom; Institute for Sustainability, University of Surrey, Guildford GU2 7XH, Surrey, United Kingdom.
| | - Sarkawt Hama
- Global Centre for Clean Air Research (GCARE), School of Engineering, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom
| | - Ho Yin Wickson Cheung
- Global Centre for Clean Air Research (GCARE), School of Engineering, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom
| | | | - Varvara A Mouchtouri
- Laboratory of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa 41222, Greece
| | - Lemonia Anagnostopoulos
- Laboratory of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa 41222, Greece
| | - Leonidas Kourentis
- Laboratory of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa 41222, Greece
| | - Zhaozhi Wang
- Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, United Kingdom
| | - Edwin R Galea
- Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, United Kingdom
| | - John Ewer
- Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, United Kingdom
| | - Angus Grandison
- Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, United Kingdom
| | - Fuchen Jia
- Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, United Kingdom
| | - Niko Siilin
- VTT Technical Research Centre of Finland Ltd, 02150 Espoo, Finland; Aalto University, Department of Civil Engineering, 00076 Espoo, Finland
| |
Collapse
|
2
|
Chillón SA, Fernandez-Gamiz U, Zulueta E, Ugarte-Anero A, Blanco JM. Numerical performance of CO 2 accumulation and droplet dispersion from a cough inside a hospital lift under different ventilation strategies. Sci Rep 2024; 14:6843. [PMID: 38514758 PMCID: PMC10957917 DOI: 10.1038/s41598-024-57425-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 03/18/2024] [Indexed: 03/23/2024] Open
Abstract
The impact of mechanical ventilation on airborne diseases is not completely known. The recent pandemic of COVID-19 clearly showed that additional investigations are necessary. The use of computational tools is an advantage that needs to be included in the study of designing safe places. The current study focused on a hospital lift where two subjects were included: a healthy passenger and an infected one. The elevator was modelled with a fan placed on the middle of the ceiling and racks for supplying air at the bottom of the lateral wall. Three ventilation strategies were evaluated: a without ventilation case, an upwards-blowing exhausting fan case and a downwards-blowing fan case. Five seconds after the elevator journey began, the infected person coughed. For the risk assessment, the CO2 concentration, droplet removal performance and dispersion were examined and compared among the three cases. The results revealed some discrepancies in the selection of an optimal ventilation strategy. Depending on the evaluated parameter, downward-ventilation fan or no ventilation strategy could be the most appropriate approach.
Collapse
Affiliation(s)
- Sergio A Chillón
- Energy Engineering Department, School of Engineering of Vitoria-Gasteiz, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain
| | - Unai Fernandez-Gamiz
- Energy Engineering Department, School of Engineering of Vitoria-Gasteiz, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain.
| | - Ekaitz Zulueta
- Automatic and Simulation Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain
| | - Ainara Ugarte-Anero
- Energy Engineering Department, School of Engineering of Vitoria-Gasteiz, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain
| | - Jesus Maria Blanco
- Energy Engineering Department, School of Engineering, University of the Basque Country (UPV/EHU), Plaza Ingeniero Torres Quevedo, Building 1, 48013, Bilbao, Spain
| |
Collapse
|